SMSalahaddin Mahmudi-Azer

Salahaddin Mahmudi-Azer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Salahaddin Mahmudi-Azer has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adjunctive hemoperfusion with Resin Hemoadsorption (HA) 330 cartridges improves outcomes in patients sustaining multiple Blunt Trauma: a prospective, quasi-experimental study

    by Roham Borazjani, Salahaddin Mahmudi-Azer, Mohammad Hossein Taghrir, Reza Homaeifar, Gholamreza Dabiri, Shahram Paydar, Hossein Abdolrahimzadeh Fard

    Background: Multi-organ dysfunction syndrome and multi-organ failure are the leading causes of late death in patients sustaining severe blunt trauma. So far, there is no established protocol to mitigate these sequelae. This study assessed the effect of hemoperfusion using resin-hemoadsorption 330 (HA330) cartridges on mortality and complications such as acute respiratory distress syndrome (ARDS) and systemic inflammatory response syndrome (SIRS) among such patients. Methods: This quasi-experimental study recruited patients ≥ 15 years of age with blunt trauma, injury severity score (ISS) ≥ 15, or initial clinical presentation consistent with SIRS. They were divided into two groups: the Control group received only conventional acute care, while the case group received adjunctive hemoperfusion. P-values less than 0.05 were statistically significant. Results: Twenty-five patients were included (Control and Case groups: 13 and 12 patients). The presenting vital signs, demographic and injury-related features (except for thoracic injury severity) were similar (p > 0.05). The Case group experienced significantly more severe thoracic injuries than the Control group (Thoracic AIS, median [IQR]: 3 [2–4] vs. 2 [0–2], p = 0.01). Eleven and twelve patients in the Case group had ARDS and SIRS before the hemoperfusion, respectively, and these complications were decreased considerably after hemoperfusion. Meanwhile, the frequency of ARDS and SIRS did not decrease in the Control group. Hemoperfusion significantly reduced the mortality rate in the Case group compared to the Control group (three vs. nine patients, p = 0.027). Conclusions: Adjunctive Hemoperfusion using an HA330 cartridge decreases morbidity and improves outcomes in patients suffering from severe blunt trauma.


  • Open Access

    Evaluation of Chest CT Scan as a Screening and Diagnostic Tool in Trauma Patients with Coronavirus Disease 2019 (COVID-19): A Cross-Sectional Study

    by Hossein Abdolrahimzadeh Fard, Salahaddin Mahmudi-Azer, Sepideh Sefidbakht, Pooya Iranpour, Shahram Bolandparvaz, Hamid Reza Abbasi, Shahram Paydar, Golnar Sabetian, Mohamad Mahdi Mahmoudi, Masoume Zare, et al.

    Background. The lack of enough medical evidence about COVID-19 regarding optimal prevention, diagnosis, and treatment contributes negatively to the rapid increase in the number of cases globally. A chest computerized tomography (CT) scan has been introduced as the most sensitive diagnostic method. Therefore, this research aimed to examine and evaluate the chest CT scan as a screening measure of COVID-19 in trauma patients. Methods. This cross-sectional study was conducted in Rajaee Hospital in Shiraz from February to May 2020. All patients underwent unenhanced CT with a 16-slice CT scanner. The CT scans were evaluated in a blinded manner, and the main CT scan features were described and classified into four groups according to RSNA recommendation. Subsequently, the first two Radiological Society of North America (RSNA) categories with the highest probability of COVID-19 pneumonia (i.e., typical and indeterminate) were merged into the “positive CT scan group” and those with radiologic features with the least probability of COVID-19 pneumonia into “negative CT scan group.” Results. Chest CT scan had a sensitivity of 68%, specificity of 56%, positive predictive value of 34.8%, negative predictive value of 83.7%, and accuracy of 59.3% in detecting COVID-19 among trauma patients. Moreover, for the diagnosis of COVID-19 by CT scan in asymptomatic individuals, a sensitivity of 100%, specificity of 66.7%, and negative predictive value of 100% were obtained ( value: 0.05). Conclusion. Findings of the study indicated that the CT scan’s sensitivity and specificity is less effective in diagnosing trauma patients with COVID-19 compared with nontraumatic people.


  • Open Access

    Establishment of a novel triage system for SARS-CoV-2 among trauma victims in trauma centers with limited facilities

    by Hossein Abdolrahimzadeh Fard, Roham Borazjani, Golnar Sabetian, Zahra Shayan, Shahram Boland Parvaz, Hamid Reza Abbassi, Shiva Aminnia, Maryam Salimi, Ali Taheri Akerdi, Masome Zare, et al.

    Objectives The triage of trauma patients with potential COVID-19 remains a major challenge given that a significant number of patients may be asymptomatic or pre-symptomatic. This study aimed to compare the specificity and sensitivity of available triage systems for COVID-19 among trauma patients. Furthermore, it aimed to develop a novel triage system for SARS-CoV-2 detection among trauma patients in centers with limited resources. Methods All patients referred to our center from February to May 2020 were enrolled in this prospective study. We evaluated the SARS-CoV-2 triage protocols from the WHO, the Iranian Ministry of Health and Medical Education (MOHME), and the European Centre for Disease Control and Prevention (ECDC) for their effectiveness in finding COVID-19 infected individuals among trauma patients. We then used these data to design a stepwise triage protocol to detect COVID-19 positive patients among trauma patients. Results According to our findings, the WHO protocol showed 100% specificity and 13.3% sensitivity. The MOHME protocol had 99% specificity and 23.3% sensitivity. While the ECDC protocol showed 93.3% sensitivity and 89.5% specificity, it did not prioritize patients based on traumatic injuries and unstable conditions. Our stepwise triage protocol, which prioritizes traumatic injuries, had 93.3% sensitivity and 90.3% specificity. Conclusion Our study shows that the triage protocols from the WHO, MOHME and ECDC are not best equipped to diagnose SARS-CoV-2 infected individuals among trauma patients. In our proposed stepwise triage system, patients are triaged according to their hemodynamic conditions, COVID-19 related clinical states, and COVID-19 related laboratory findings. Our triage model can lead to more accurate and resource-effective management of trauma patients with potential COVID-19 infection. Level of evidence Level Ⅲ.


  • Open Access

    Connexin 43 Expression on Peripheral Blood Eosinophils: Role of Gap Junctions in Transendothelial Migration

    by Harissios Vliagoftis, Cory Ebeling, Ramses Ilarraza, Salahaddin Mahmudi-Azer, Melanie Abel, Darryl Adamko, A. Dean Befus, Redwan Moqbel

    Eosinophils circulate in the blood and are recruited in tissues during allergic inflammation. Gap junctions mediate direct communication between adjacent cells and may represent a new way of communication between immune cells distinct from communication through cytokines and chemokines. We characterized the expression of connexin (Cx)43 by eosinophils isolated from atopic individuals using RT-PCR, Western blotting, and confocal microscopy and studied the biological functions of gap junctions on eosinophils. The formation of functional gap junctions was evaluated measuring dye transfer using flow cytometry. The role of gap junctions on eosinophil transendothelial migration was studied using the inhibitor 18-a-glycyrrhetinic acid. Peripheral blood eosinophils express Cx43 mRNA and protein. Cx43 is localized not only in the cytoplasm but also on the plasma membrane. The membrane impermeable dye BCECF transferred from eosinophils to epithelial or endothelial cells following coculture in a dose and time dependent fashion. The gap junction inhibitors 18-a-glycyrrhetinic acid and octanol did not have a significant effect on dye transfer but reduced dye exit from eosinophils. The gap junction inhibitor 18-a-glycyrrhetinic acid inhibited eosinophil transendothelial migration in a dose dependent manner. Thus, eosinophils from atopic individuals express Cx43 constitutively and Cx43 may play an important role in eosinophil transendothelial migration and function in sites of inflammation.