Nghia-Hieu Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nghia-Hieu Nguyen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Quoc-An Hoang
Ho Chi Minh City University of Technology and Education
7 shared publicationsHiep-Chi Le
Ho Chi Minh City University of Technology
6 shared publications- Bao-Chi Le
Department of Heat & Refrigeration Engineering, Ho Chi Minh City University of Technology, Ho Chi Minh 72506, Vietnam
3 shared publications - Thanh Trung Bui
Industrial University of Ho Chi Minh City
2 shared publications Hiep-Chi LE
1 shared publicationHung-Duong Hoang
Quang Binh University
1 shared publication
Latest Publications
- Open Access
- 12 October 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34 (1) , 28
Model parameter optimization for chiller fault diagnosis using differential evolution and genetic algorithms
To reduce operating costs and prevent equipment damage through early fault detection in chillers, this study proposes an advanced diagnostic strategy integrating the Radial Basis Function (RBF) model with Exponentially Weighted Moving Average (EWMA) residual charts. While RBF models are proficient in handling nonlinear problems, they are often susceptible to overfitting and performance degradation under data disturbances. These limitations are overcome to optimize model parameters by the Differential Evolution (DE) and Genetic Algorithm (GA), achieving not only higher coefficient of determination coefficients (R2) but also low root mean square errors for two common types of nonlinear faults such as Refrigerant Leakage (RF) and Condenser Fouling (CF). Analysis using the ASHRAE RP-1043 dataset shows that the DE-RBF-EWMA model achieves a diagnostic confidence of 98.48% for the LMTDcd parameter and 98.56% for the Epsilon parameter. This strategy effectively identifies RF and CF across four severity levels, providing a robust tool for real-time chiller monitoring. The true alarm rate of the DE-RBF-EWMA model is the best, especially important at high serious level of faults, reaching 94.30% of RF and 74.90% of CF.
- 12 October 2026
- Published by Springer Nature in International Journal of Air-Conditioning and Refrigeration
- Vol. 34 (1) , 28
Open AccessModel parameter optimization for chiller fault diagnosis using differential evolution and genetic algorithms
To reduce operating costs and prevent equipment damage through early fault detection in chillers, this study proposes an advanced diagnostic strategy integrating the Radial Basis Function (RBF) model with Exponentially Weighted Moving Average (EWMA) residual charts. While RBF models are proficient in handling nonlinear problems, they are often susceptible to overfitting and performance degradation under data disturbances. These limitations are overcome to optimize model parameters by the Differential Evolution (DE) and Genetic Algorithm (GA), achieving not only higher coefficient of determination coefficients (R2) but also low root mean square errors for two common types of nonlinear faults such as Refrigerant Leakage (RF) and Condenser Fouling (CF). Analysis using the ASHRAE RP-1043 dataset shows that the DE-RBF-EWMA model achieves a diagnostic confidence of 98.48% for the LMTDcd parameter and 98.56% for the Epsilon parameter. This strategy effectively identifies RF and CF across four severity levels, providing a robust tool for real-time chiller monitoring. The true alarm rate of the DE-RBF-EWMA model is the best, especially important at high serious level of faults, reaching 94.30% of RF and 74.90% of CF.
- Open Access
Design considerations of a new freezer construction in the tubular ice machine by experimental study
- Open Access
- 15 June 2023
- Published by Springer Nature
- p. C1
Correction to: Theoretical and Experimental Study of the Effective Operation Mode of Absorption Refrigeration Chiller for Ice Production
- 15 June 2023
- Published by Springer Nature
- p. C1
Open AccessCorrection to: Theoretical and Experimental Study of the Effective Operation Mode of Absorption Refrigeration Chiller for Ice Production
- Open Access
Technical Analysis of the Large Capacity Grid-Connected Floating Photovoltaic System on the Hydropower Reservoir
Among the energy targets of the Vietnamese government, solar energy is expected to become the main source of renewable energy in the future. Solar energy is moving forward, with Vietnam outstripping Thailand and becoming the country that installed the largest capacity of solar power generation in Southeast Asia, reaching 16,362 MW in new installations in December 2021. In this study, we have experimentally analyzed and designed a capacity of 47.5 MW grid-connected photovoltaic plant mounted on the floatation system at Da Mi hydropower reservoir in Binh Thuan province. This was selected to be utilized as the first effort to develop the first large-capacity floating solar power plant on a hydroelectric reservoir in Vietnam. A detailed examination of the electrical analysis, including DC to DC converters, AC inverters to the transmission network, and PV module connectivity configurations, are in scope. The present research has the potential to make a contribution to the design of the DC electrical part, the AC electrical part, and the layout PV modules—Inverter—Floatation system—Floating bridge of FPV plants which are less described in the former articles. The performance of the plant after the first 2 years of operation has confirmed that it has met the expectations and exceeded the investor’s target, with the power output of the first 2 years being higher than the design by 102.58% to 105.59% and no serious damage has occurred to the equipment from 1 June 2019 to 31 August 2021.
Open AccessTechnical Analysis of the Large Capacity Grid-Connected Floating Photovoltaic System on the Hydropower Reservoir
Among the energy targets of the Vietnamese government, solar energy is expected to become the main source of renewable energy in the future. Solar energy is moving forward, with Vietnam outstripping Thailand and becoming the country that installed the largest capacity of solar power generation in Southeast Asia, reaching 16,362 MW in new installations in December 2021. In this study, we have experimentally analyzed and designed a capacity of 47.5 MW grid-connected photovoltaic plant mounted on the floatation system at Da Mi hydropower reservoir in Binh Thuan province. This was selected to be utilized as the first effort to develop the first large-capacity floating solar power plant on a hydroelectric reservoir in Vietnam. A detailed examination of the electrical analysis, including DC to DC converters, AC inverters to the transmission network, and PV module connectivity configurations, are in scope. The present research has the potential to make a contribution to the design of the DC electrical part, the AC electrical part, and the layout PV modules—Inverter—Floatation system—Floating bridge of FPV plants which are less described in the former articles. The performance of the plant after the first 2 years of operation has confirmed that it has met the expectations and exceeded the investor’s target, with the power output of the first 2 years being higher than the design by 102.58% to 105.59% and no serious damage has occurred to the equipment from 1 June 2019 to 31 August 2021.
- Open Access
- 24 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2948
Benefit Analysis of Grid-Connected Floating Photovoltaic System on the Hydropower Reservoir
In the step-by-step roadmap for limiting and eliminating power sources that use fossil fuel, especially coal-fired power, as well as for setting the Vietnamese government targets for developing renewable energy for replacement, solar farms and rooftop solar power, followed by floating photovoltaic (PV) power, are considered the best candidates for meeting the goals of land space, PV system operation efficiency, and meeting environmental goals. In addition to the rapid development of PV cell technology are the government’s incentives and financial support for PV plants on the water surface area, which is still very large. Floating PV plants will strongly attract investors in the near future. This study could help stakeholders in the market understand the economic–technical aspects from analyzing economic–financial indicators of floating PV plants with a capacity of 47.5 MW connected to the national utility grid 110 kV at Da Mi hydropower reservoir in Binh Thuan province, Vietnam, in May 2019. This is the first floating PV plant on the reservoir in Vietnam, and is the property of a third party.
- 24 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2948
Open AccessBenefit Analysis of Grid-Connected Floating Photovoltaic System on the Hydropower Reservoir
In the step-by-step roadmap for limiting and eliminating power sources that use fossil fuel, especially coal-fired power, as well as for setting the Vietnamese government targets for developing renewable energy for replacement, solar farms and rooftop solar power, followed by floating photovoltaic (PV) power, are considered the best candidates for meeting the goals of land space, PV system operation efficiency, and meeting environmental goals. In addition to the rapid development of PV cell technology are the government’s incentives and financial support for PV plants on the water surface area, which is still very large. Floating PV plants will strongly attract investors in the near future. This study could help stakeholders in the market understand the economic–technical aspects from analyzing economic–financial indicators of floating PV plants with a capacity of 47.5 MW connected to the national utility grid 110 kV at Da Mi hydropower reservoir in Binh Thuan province, Vietnam, in May 2019. This is the first floating PV plant on the reservoir in Vietnam, and is the property of a third party.
- 1 June 2022
- Published by Springer Nature
- p. 1324-1346
Theoretical and Experimental Study of the Effective Operation Mode of Absorption Refrigeration Chiller for Ice Production
- 1 June 2022
- Published by Springer Nature
- p. 1324-1346
Theoretical and Experimental Study of the Effective Operation Mode of Absorption Refrigeration Chiller for Ice Production
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 436-441
Theoretical and Experimental Study of Intermittent Absorption Refrigeration System
In the absorption refrigerations, intermittent absorption refrigeration system is a bright candidate for widespread application because of the simplicity of fabrication, operation, and utilization of large solar power in Vietnam This paper presents the relationship of optimum generation temperature to required cooling and ambient temperature in Vietnam In addition, the concentration of the feed solution in accordance with the evaporation temperature achieved and evaporation requirements are also determined The results were found and evaluated with other similar studies by other authors. In order to reach this target, the simulation related to intermittent absorption refrigeration system were developed. Based on these simulations, the theoretical studies were done for intermittent absorption refrigeration system in order to narrow the working area where the experiments later focused on. The results of this study will be the basis for subsequent application research.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 436-441
Theoretical and Experimental Study of Intermittent Absorption Refrigeration System
In the absorption refrigerations, intermittent absorption refrigeration system is a bright candidate for widespread application because of the simplicity of fabrication, operation, and utilization of large solar power in Vietnam This paper presents the relationship of optimum generation temperature to required cooling and ambient temperature in Vietnam In addition, the concentration of the feed solution in accordance with the evaporation temperature achieved and evaporation requirements are also determined The results were found and evaluated with other similar studies by other authors. In order to reach this target, the simulation related to intermittent absorption refrigeration system were developed. Based on these simulations, the theoretical studies were done for intermittent absorption refrigeration system in order to narrow the working area where the experiments later focused on. The results of this study will be the basis for subsequent application research.
- Open Access
- 25 July 2018
- Published by Science Publishing Group in Mathematics and Computer Science
- Vol. 3 (4) , 93-99
Heat and Mass Transfer of NH 3 -H 2 O Falling-Film Absorption on Horizontal Round Tube Banks
The absorption process has been confirmed as the most important process in absorption refrigeration machines in terms of improving their total efficiency. For this reason, absorber structures in general and heat and mass transfers in absorber in particular have attracted the interest of many researchers in this field. Commonly, the falling film absorber structure is the liquid mixture flows over tubes in a film mode. Mathematical model is developed for the falling film flowing on horizontal round tubes absorber derived from the mathematical model of the test volume element. The two-dimensional numerical simulation is written to solve partial differential equations predicting absorption efficiency. For evaluating the parameters which affect the coupled heat-mass transfer as NH 3 -H 2 O diluted solution flowing over horizontal round tubes absorb NH 3 vapor to become the higher concentration solution. The fields of velocity, temperature, concentration and thickness of the falling film solution varied by the input conditions of diluted solution and cooling water temperature flowing in the tube represented for a test volume element of the tube. The correlations which give the heat transfer coefficient and mass transfer coefficient in the absorption process in range of solution concentration ω = 28% ÷ 31%, solution mass flow rate per unit tube length Γ = 0.001 ÷ 0.015 kgm -1 s -1 , coolant temperature t water = 28°C ÷ 38oC are set as two functions. The accuracy of numerical model and experiments are compared by the inlet, outlet the tube bundle of cooling water temperatures and absorber heat load. The absorber heat load deviation of the computing program Q a_cumpute and experimental result Q a_meas is 4.3%. The absorber heat load deviation of simulation result Q a_sim and experimental result Qa_meas is 12.3%. The overall heat transfer coefficient k used for simulation result of absorber heat load was taken from the relationship of the heat transfer coefficient k = f(C; Г; T) = f(0.308; 0.008; 306.3) = 0.863 kWm -2</sup K -1 ). The results were also evaluated with other similar studies by other authors. Based on these simulations, the theoretical studies were done for absorption refrigeration system in order to narrow the working area where the experiments later focused on. The results of this study will be the basis for subsequent application research of falling film absorbers.
- 25 July 2018
- Published by Science Publishing Group in Mathematics and Computer Science
- Vol. 3 (4) , 93-99
Open AccessHeat and Mass Transfer of NH 3 -H 2 O Falling-Film Absorption on Horizontal Round Tube Banks
The absorption process has been confirmed as the most important process in absorption refrigeration machines in terms of improving their total efficiency. For this reason, absorber structures in general and heat and mass transfers in absorber in particular have attracted the interest of many researchers in this field. Commonly, the falling film absorber structure is the liquid mixture flows over tubes in a film mode. Mathematical model is developed for the falling film flowing on horizontal round tubes absorber derived from the mathematical model of the test volume element. The two-dimensional numerical simulation is written to solve partial differential equations predicting absorption efficiency. For evaluating the parameters which affect the coupled heat-mass transfer as NH 3 -H 2 O diluted solution flowing over horizontal round tubes absorb NH 3 vapor to become the higher concentration solution. The fields of velocity, temperature, concentration and thickness of the falling film solution varied by the input conditions of diluted solution and cooling water temperature flowing in the tube represented for a test volume element of the tube. The correlations which give the heat transfer coefficient and mass transfer coefficient in the absorption process in range of solution concentration ω = 28% ÷ 31%, solution mass flow rate per unit tube length Γ = 0.001 ÷ 0.015 kgm -1 s -1 , coolant temperature t water = 28°C ÷ 38oC are set as two functions. The accuracy of numerical model and experiments are compared by the inlet, outlet the tube bundle of cooling water temperatures and absorber heat load. The absorber heat load deviation of the computing program Q a_cumpute and experimental result Q a_meas is 4.3%. The absorber heat load deviation of simulation result Q a_sim and experimental result Qa_meas is 12.3%. The overall heat transfer coefficient k used for simulation result of absorber heat load was taken from the relationship of the heat transfer coefficient k = f(C; Г; T) = f(0.308; 0.008; 306.3) = 0.863 kWm -2</sup K -1 ). The results were also evaluated with other similar studies by other authors. Based on these simulations, the theoretical studies were done for absorption refrigeration system in order to narrow the working area where the experiments later focused on. The results of this study will be the basis for subsequent application research of falling film absorbers.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 636-641
Evaluation of heat and mass transfer coefficients in horizontal tube falling film NH3-H2O absorber
Absorption phenomenon of NH 3 into NH 3 -H 2 O solution has analysed theoreticcally. The heat transfer coefficient obtained from the coupled heat and mass transfer mathematic model. This heat transfer coefficient is used to calculate the variation of the simulated value of heat load. The practical decrease of wetted ratio analyses were taken into account when the solution flow from the top to the bottom of the parallel tube bundle. The deviation of theoretical heat load and experimental heat load is about 10%. In addition heat transfer coefficient and mass transfer coefficient of the absorption process are agree well with other studies. A correlation which gives the heat transfer coefficient and mass transfer coefficient as funtions of the initial solution concentration, solution mass flow rate per unit tube length, and cooling water temperature are derived to estimate the absorber heat load and mass absorption flow rate of NH 3 vapor into NH 3 -H 2 O solution.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 636-641
Evaluation of heat and mass transfer coefficients in horizontal tube falling film NH3-H2O absorber
Absorption phenomenon of NH 3 into NH 3 -H 2 O solution has analysed theoreticcally. The heat transfer coefficient obtained from the coupled heat and mass transfer mathematic model. This heat transfer coefficient is used to calculate the variation of the simulated value of heat load. The practical decrease of wetted ratio analyses were taken into account when the solution flow from the top to the bottom of the parallel tube bundle. The deviation of theoretical heat load and experimental heat load is about 10%. In addition heat transfer coefficient and mass transfer coefficient of the absorption process are agree well with other studies. A correlation which gives the heat transfer coefficient and mass transfer coefficient as funtions of the initial solution concentration, solution mass flow rate per unit tube length, and cooling water temperature are derived to estimate the absorber heat load and mass absorption flow rate of NH 3 vapor into NH 3 -H 2 O solution.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Studying optimal generator temperature of single effect NH3-H2O absorption refrigeration machine for ice-making
This paper present the coefficient of performance analysis of a NH3-H2O absorption refrigeration machine with the heat supply 3.76kW, cooling the 23% NaCl solution from the ambient temperature 30°C to -18°C. The working machine is controlled according to the different flow rates of the weak solution supplying the absorber. The fluctuation of the cooling capacity according to the NH3 refrigerant throttling to the evaporator which is observed. The absorption refrigeration machine simulation program is established for testing and evaluating the experimental data again to ensure the absorption refrigeration machine working correctly to the initial design. The operating temperature simulations of the machine are compared with other studies, the deviation are from 2 to 7% at the optimal coefficient of performance. Base on this basis, the correlation of optimal generation temperature with condensation, absorption and evaporation temperatures of the machine components are set into an equation presented in this paper.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Studying optimal generator temperature of single effect NH3-H2O absorption refrigeration machine for ice-making
This paper present the coefficient of performance analysis of a NH3-H2O absorption refrigeration machine with the heat supply 3.76kW, cooling the 23% NaCl solution from the ambient temperature 30°C to -18°C. The working machine is controlled according to the different flow rates of the weak solution supplying the absorber. The fluctuation of the cooling capacity according to the NH3 refrigerant throttling to the evaporator which is observed. The absorption refrigeration machine simulation program is established for testing and evaluating the experimental data again to ensure the absorption refrigeration machine working correctly to the initial design. The operating temperature simulations of the machine are compared with other studies, the deviation are from 2 to 7% at the optimal coefficient of performance. Base on this basis, the correlation of optimal generation temperature with condensation, absorption and evaporation temperatures of the machine components are set into an equation presented in this paper.