Yusuke Tokunaga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yusuke Tokunaga has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Nobuyasu Yamaguchi
Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka 565-0871, Japan
2 shared publications Akiko Edagawa
Osaka Institute of Public Health, 1-3-69 Nakamichi, Higashinari, Osaka, 537-0025, Japan
1 shared publicationFumiya Banno
Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamada-oka, Suita, Osaka, 565-0871, Japan
1 shared publicationHotaka Kusabuka
Laboratory of Biotechnology and Therapeutics, Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamadaoka, Suita, Osaka 565-0871, Japan
1 shared publication- Kento Fujiwara
Laboratory of Biotechnology and Therapeutics, Graduate School of Pharmaceutical Sciences, Osaka University, 1-6 Yamadaoka, Suita, Osaka 565-0871, Japan
1 shared publication Mamoru Saito
Osaka Research Institute of Industrial Science and Technology 1‐6‐50, Morinomiya, Joto‐ku Osaka 536‐8553 Japan
1 shared publication
Latest Publications
- 9 July 2021
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 56 (10) , 5402-5408
Microfluidic rapid quantification of Salmonella enterica serovar Typhimurium collected from chicken meat using immunomagnetic separation after formaldehyde treatment
Summary: Foodborne pathogens such as Salmonella enterica serovar Typhimurium, which cause self‐limiting gastroenteritis, are important in food safety and public health. Detection of Salmonella in complex food matrices is required for rapid and effective monitoring of contaminated food products. In this study, we collected Salmonella Typhimurium in chicken using immunomagnetic separation after formaldehyde treatment. Collected Salmonella Typhimurium cells were then quantified microfluidic device or fluorescence microscopy. The recovery ratio obtained with immunomagnetic separation after formaldehyde treatment was 77 (±5)% for the microscope count and 63 (±9)% for the microfluidic count. According to the fluorescence microscope images, the food matrix was effectively removed from the collected cell suspension. The counts of Salmonella Typhimurium cells obtained by the microfluidic device and fluorescence microscope were closely correlated (R2 = 0.993) with a range of 3.3 (±0.5) × 103 to 1.2 (±0.5) × 106 cells g−1. Our method provides quantitative detection of Salmonella Typhimurium within 3–4 h and could be used to efficiently evaluate microbial risk of quality control of foodstuffs and prevention of foodborne disease.
- 9 July 2021
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 56 (10) , 5402-5408
Microfluidic rapid quantification of Salmonella enterica serovar Typhimurium collected from chicken meat using immunomagnetic separation after formaldehyde treatment
Summary: Foodborne pathogens such as Salmonella enterica serovar Typhimurium, which cause self‐limiting gastroenteritis, are important in food safety and public health. Detection of Salmonella in complex food matrices is required for rapid and effective monitoring of contaminated food products. In this study, we collected Salmonella Typhimurium in chicken using immunomagnetic separation after formaldehyde treatment. Collected Salmonella Typhimurium cells were then quantified microfluidic device or fluorescence microscopy. The recovery ratio obtained with immunomagnetic separation after formaldehyde treatment was 77 (±5)% for the microscope count and 63 (±9)% for the microfluidic count. According to the fluorescence microscope images, the food matrix was effectively removed from the collected cell suspension. The counts of Salmonella Typhimurium cells obtained by the microfluidic device and fluorescence microscope were closely correlated (R2 = 0.993) with a range of 3.3 (±0.5) × 103 to 1.2 (±0.5) × 106 cells g−1. Our method provides quantitative detection of Salmonella Typhimurium within 3–4 h and could be used to efficiently evaluate microbial risk of quality control of foodstuffs and prevention of foodborne disease.
- Open Access
- 8 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Rapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
Legionnaires’ disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5–3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
- 8 June 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Open AccessRapid on-site monitoring of Legionella pneumophila in cooling tower water using a portable microfluidic system
Legionnaires’ disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 104 cells/ml, but lower numbers of L. pneumophila cells (101 to 103 cells/ml) could be detected following concentration of 0.5–3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.