LZLingling Zhou

Lingling Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lingling Zhou has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Yongji Zhang

    State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China

    6 shared publications
  • Gui-Bai Li

    Harbin Institute of Technology

    3 shared publications
  • Yongji Zhang

    Tongji Univ, State Key Lab Pollut Control & Resources Reuse, Shanghai 200092, Peoples R China

    3 shared publications
  • Chaoqun Tan

    Key Laboratory of Yangtze River Water Environment, Ministry of Education, Tongji University, Shanghai 200092, PR China

    1 shared publication
  • Doudou Huang

    Key Laboratory of Yangtze River Water Environment, Ministry of Education, Tongji University, Shanghai 200092, China

    1 shared publication
  • He-Xiu Ye

    1 shared publication

Latest Publications

  • Open Access

    Control of Loose Deposits in a Simulated Drinking Water Distribution System Using Ultrafiltration

    by Yongji Zhang, Huimin Hou, Mengyu Qiu, Lingling Zhou

    Loose deposits on water supply pipe walls easily fall off and may affect the safety of the drinking water supply, and the control of them has been a hot research issue in recent years. In this research, we used two simulated pipeline test reactors to systematically study the formation and shedding pattern of loose sediment on the pipeline, analyze its characteristics, and explore the control role of the ultrafiltration process on loose sediment in the water supply pipeline network. The results showed that the loose deposits adhered to the pipe reactor fed by filtered water formed slower than did that fed by unfiltered water, the maximum accumulation of the loose deposits was reduced from 2.17 to 1.46 g/m2. The reactor after ultrafiltration showed a reduction of more than 40% in the concentration of substances other than Ca and Si. Copper and zinc were reduced by more than 80%, while the iron content was reduced by 91.2%. When the shear force of the pipe wall of the water pipeline is less than 0.33 Pa, there are loose deposits formed on the pipe wall; when the shear force of the pipe wall of the water pipeline is greater than 0.94 Pa, it was found that the loose deposits on the pipe wall were shed more completely. Ultrafiltration removes most of the suspended living bacteria, but it is not effective in removing dissolved organic matter from the water, resulting in high peak levels of bacteria on the walls and in the effluent. The maximum bacterial content of the reactor effluent after ultrafiltration was 1.6 × 104 CFU/cm2 after 22 d. It is therefore necessary to consider the use of the ultrafiltration process in conjunction with other processes to achieve the ultimate goal of controlling microbial contamination in the pipeline network.


  • Open Access

    Disinfection Kinetics of Free Chlorine, Monochloramines and Chlorine Dioxide on Ammonia-Oxidizing Bacterium Inactivation in Drinking Water

    by Yongji Zhang, Jie Qiu, Xianfang Xu, Lingling Zhou

    With the widespread use of chloramines disinfection, nitrification has become a problem that cannot be ignored. In order to control nitrification in the drinking water distribution system (DWDS), the inactivation effect of free chlorine, monochloramine and chlorine dioxide on ammonia-oxidizing bacterium (AOB) was studied under different temperature (8 °C, 26 °C and 35 °C) and pH (6.0, 7.0 and 8.7) conditions. The inactivation effect of Nitrosomonas europaea (a kind of AOB) by the three disinfectants increases with increasing temperature. As for the raised pH, the inactivation effect of free chlorine and monochloramine on AOB decreased, while that of chlorine dioxide increased. Last, but certainly not least, the experimental data of the disinfection were calculated to develop the N. europaea inactivation kinetic model, which was based on the first order Chick–Watson equation. The proposed model in this study took the two variables, pH and temperature, into consideration simultaneously, which were used to evaluate the average Ct value (multiplying the concentration of the residual disinfectant by the time of contact with N. europaea) required for different disinfectants when they produced the ideal inactivation effect on N. europaea.


  • Open Access

    Effect and mechanism of reduced membrane bioreactor fouling by powdered activated carbon

    by Yongji Zhang, Xiaotong Wang, Hexiu Ye, Lingling Zhou, Zhiling Zhao

    Powered Activated Carbon – Membrane Bioreactors (PAC-MBRs) have been used with good results for slightly polluted water treatment. Our batch experiments showed that the transmembrane pressure of a PAC-MBR was 25% less than that of a MBR in one period of test, which indicated that PAC did help control the fouling in MBRs. Based on this observation, several mechanisms of membrane fouling of MBRs and PAC-MBRs were investigated to have some insight into how PAC brought a positive impact. The total resistances decreased by 60% and different resistances were redistributed after adding PAC. The dominant one changed from filtration resistance to cake resistance. These smaller cake resistances resulted from the PAC because, showing in the scanning electron microscopy pictures, it made the cake layer looser and rougher than that on a normal membrane. Meanwhile, the analysis of the membrane eluent showed that the addition of PAC changed the microbial species and its metabolites on the membrane and effectively reduced the adsorption of hydrophilic organic molecules on the membrane surface. Additionally, PAC prevented polypeptide compounds from being trapped inside the pores of membranes, so the cake on the PAC-MBR contaminated membrane surface was easier to scrape off. In the test of cleaning methods, alkaline cleaning removed the most organics from contaminated membranes to restore membrane performance.


    • 1 August 2012
      • Vol. 33  (8) , 2680-4

    [Comparison study of enhanced coagulation on humic acid and fulvic acid removal].

    by Ling-Ling Zhou, Yong-Ji Zhang, He-Xiu Ye, Yi-Qing Zhang

    Enhanced coagulation effects of four coagulants, such as aluminium sulfate, ferric chloride, aluminium polychloride and poly-ferric chloride, were examined, with an emphasis on pH, turbidity, Ca+ and relative contents of humic acid and fulvic acid. The result showed that the removal efficiency of four kinds of coagulant for humic acid was higher than that for fulvic acid. Compared with aluminium polychloride and poly-ferric chloride, aluminium sulfate and ferric chloride possessed a better coagulation effect. At the coagulant dosage of 40 mg x L(-1), ferric chloride, aluminium sulfate, poly-ferric chloride and aluminium polychloride removed fulvic acid from 10 mg x L(-1) to 3.22 mg x L(-1), 4.34 mg x L(-1), 5.85 mg x L(-1) and 4.86 mg x L(-1) respectively, while the four coagulants removed humic acid from 10 mg x L(-1) to 1.13 mg x L(-1), 2.13 mg x L(-1), 3.44 mg x L(-1) and 2.50 mg x L(-1) respectively in water. At pH between 5.5 and 6.5, aluminium sullfate and ferric chloride had the best coagulation effect. The coagulant had the lower efficiency with increase of organic carbon in water. Especially, the content ratio of fulvic acid and humic acid was above 0.4, the coagulation effect markedly decreased. Turbidity has a little influence on organic carbon removal rate. With the concentration of Ca2+, the removal efficiency of humic acid and fulvic acid increased.

  • Effect of pipe material and low level disinfectants on biofilm development in a simulated drinking water distribution system

    by Ling-Ling Zhou, Yong-Ji Zhang, Gui-Bai Li

    The efficiency of chlorine and chloramines disinfection on biofilm development in a simulated drinking water distribution system was investigated by using heterotrophic bacterial spread plate technique. The experiments were carried out with four annular reactors (ARs) with stainless steel (SS) or copper (Cu) material slides. The results showed that there were fewer bacteria attached to Cu slides without a disinfectant compared with those attached to SS slides. When the water was disinfected with chloramines, the heterotrophic plate counts (HPCs) on the biofilm attached to the Cu slides were significantly lower (by 3.46 log CFU/cm2) than those attached to the SS slides. Likewise, the biofilm HPC numbers on the Cu slides were slightly lower (by 1.19 log CFU/cm2) than those on the SS slides disinfected with chlorine. In a quasi-steady state, the HPC levels on Cu slides can be reduced to 3.0 log CFU/cm2 with chlorine and to about 0.9 log CFU/cm2 with chloramines. The addition of chloramines resulted in a more efficient reduction of biofilm heterotrophic bacteria than did chlorine. We concluded that the chlorine and chloramines levels usually employed in water distribution system were not sufficient to prevent the growth and development of microbial biofilm. The combination of copper pipe slides and chloramines as the disinfectant was the most efficient combination to bring about diminished bacterial levels.


    • 1 December 2008
      • Vol. 29  (12) , 3372-5

    [Effect of chloramines disinfection for biofilm formation control on copper and stainless steel pipe materials].

    by Ling-Ling Zhou, Yong-Ji Zhang, Xing Li, Gui-Bai Li

    Two rotating annular bioreactors (RABs) with copper and stainless steel pipe materials were adopted in the study, the effects of these two pipe materials and chloramines disinfection on biofilms formation in drinking water distribution system were evaluated. The maximum viable bacterial number in biofilm of copper and stainless steel reached 5.5 x 10(3) CFU/cm2 and 2.5 x 10(5) CFU/cm2 at 18th and 21st day without chloramines, and the viable bacterial number at the apparent steady state was 1.0 x 10(3) CFU/cm2 and 1.3 x 10(5) CFU/cm2 respectively. It was obvious that the biomass on copper materials was lower than that of the stainless steel. The maximum viable bacterial on copper and stainless steel under chloramines was 5.0 x 10(2) CFU/cm2 and 5.0 x 10(4) CFU/cm2, which was one order of magnitude lower than that of without chloramines, and its number was 10 CFU/cm2 and 3.5 x 10(4) CFU/cm2 at the steady state. These results illustrated that chloramines had apparent ability in controlling biomass when the biofilm was on steady states, especially for copper material. There was exponential relationship between biomass in biofilm and residue chloramines, which meant less biomass with more chloramines, synergistic effects were observed between chloramines and copper materials on biomass in biofilms inactivation.

    • 1 May 2008
      • Vol. 29  (5) , 1187-91

    [Characteristic of natural organic matter removal by ferric and aluminium coagulation].

    by Ling-Ling Zhou, Yong-Ji Zhang, Li-Hua Sun, Gui-Bai Li

    Natural organic matter removal efficiency and characteristic by ferric chloride and aluminium sulphate were studied. Results showed that ferric chloride was effective in natural organic matter removal when coagulant dosage was higher than 15 mg/L, while aluminium was effective at lower dosage. The TOC of water was reduced to 4.19 mg/L and 9 mg/L at a dosage of 10 mg/L for aluminium sulphate and ferric chloride respectively, while TOC was reduced to 2.44 mg/L and 1.69 mg/L at the dosage of 20 mg/L. Ferric chloride decreased pH sharply than aluminium sulphate which made hydrolysate more positive and attachable for natural organic matter. UV254 and SUVA results showed that ferric chloride removed more conjugate structure materials and unsaturated band contents than aluminium. Ferric chloride was more effective in reducing lower molecular weight organic matter and hydrophilic substances than aluminium, when the dosage of coagulant was 20 mg/L, the removal efficiency of relative molecular weight below 10 000 was 16.4% and 6.1% respectively, while aluminum was more effective in high molecular weight matter removal than ferric chloride.