Jyh Jian Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jyh Jian Chen has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Chia Ming Shen
Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, Neipu, Taiwan
5 shared publicationsSin Jhih Chen
Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, Pingtung, Taiwan
4 shared publications- Shyang-Chwen Sheu
Department of Food Science, National Pingtung University of Science and Technology, Pingtung, Taiwan
3 shared publications Yu Wei Ko
Department of Biomechatronics Engineering, National Pingtung University of Science and Technology, Pingtung, Taiwan
3 shared publications- Chia-Hsien Hsu
Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes
2 shared publications - Chun Huei Chen
Department of Mechanical Engineering, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan
2 shared publications
Latest Publications
- 29 October 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 721
Portable micro-spectrometric LAMP platform for rapid semi-quantitative pathogen detection in food safety
- 29 October 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 721
Portable micro-spectrometric LAMP platform for rapid semi-quantitative pathogen detection in food safety
- 30 June 2026
- Published by Springer Nature in Biomedical Microdevices
- Vol. 28 (3) , 52
A pump-free gravity-driven microfluidic chip for rapid RPA-LFS-based detection of Magnaporthe oryzae AvrPi9 gene
We present a pump-free, gravity-assisted microfluidic lab-on-a-chip platform for the rapid detection of the rice blast pathogen Magnaporthe oryzae by targeting the AvrPi9 gene. The system integrates precise thermal control, programmable fluidic sequencing, and lateral-flow readout, enabling low-power diagnostics without complex instrumentation. Temperature regulation is achieved using a LinkIt 7697 development board, coupled with a proportional-integral-derivative (PID) controller, to drive a Peltier element. This maintains a stable reaction environment at 39 ± 0.5 °C for recombinase polymerase amplification (RPA). The microfluidic chip (65 mm × 34 mm × 5 mm) is fabricated via laser cutting and hot pressing, with the reaction chamber validated for spatial temperature uniformity through infrared thermal imaging. To enhance operational reliability in field settings, the platform utilizes a manual pin-actuated puncture mechanism to initiate fluidic transport. After a 5-minute isothermal amplification, the physical piercing of a sealing membrane opens strategic air vents, inducing a capillary-driven flow and pressure imbalance that facilitates the pump-free transport of 30 µL of RPA products into the lateral flow strip (LFS). This deterministic mechanical gating replaces complex actuators, ensuring a 100% success rate for vent opening. Visual results appear within 2 min, with a total assay time of approximately 15 min, achieving a detection limit of 10 pg/µL for AvrPi9. The system demonstrates high specificity, with no cross-reactivity to non-target pathogens, including Bipolaris oryzae, Sarocladium oryzae, and Ephelis sp., owing to strategic primer mismatches. This robust, pin-actuated, valve-free system highlights the potential for reliable, low-power, field-deployable nucleic acid diagnostics in point-of-care settings. While this study serves primarily as a hardware engineering proof-of-concept focusing on pump-free fluidic transportation, it establishes a foundational architecture for decentralized molecular diagnostics. Future translational development will focus on integrating raw matrix sample preparation to bypass the current limitation of requiring purified nucleic acid inputs. Graphic abstract
- 30 June 2026
- Published by Springer Nature in Biomedical Microdevices
- Vol. 28 (3) , 52
A pump-free gravity-driven microfluidic chip for rapid RPA-LFS-based detection of Magnaporthe oryzae AvrPi9 gene
We present a pump-free, gravity-assisted microfluidic lab-on-a-chip platform for the rapid detection of the rice blast pathogen Magnaporthe oryzae by targeting the AvrPi9 gene. The system integrates precise thermal control, programmable fluidic sequencing, and lateral-flow readout, enabling low-power diagnostics without complex instrumentation. Temperature regulation is achieved using a LinkIt 7697 development board, coupled with a proportional-integral-derivative (PID) controller, to drive a Peltier element. This maintains a stable reaction environment at 39 ± 0.5 °C for recombinase polymerase amplification (RPA). The microfluidic chip (65 mm × 34 mm × 5 mm) is fabricated via laser cutting and hot pressing, with the reaction chamber validated for spatial temperature uniformity through infrared thermal imaging. To enhance operational reliability in field settings, the platform utilizes a manual pin-actuated puncture mechanism to initiate fluidic transport. After a 5-minute isothermal amplification, the physical piercing of a sealing membrane opens strategic air vents, inducing a capillary-driven flow and pressure imbalance that facilitates the pump-free transport of 30 µL of RPA products into the lateral flow strip (LFS). This deterministic mechanical gating replaces complex actuators, ensuring a 100% success rate for vent opening. Visual results appear within 2 min, with a total assay time of approximately 15 min, achieving a detection limit of 10 pg/µL for AvrPi9. The system demonstrates high specificity, with no cross-reactivity to non-target pathogens, including Bipolaris oryzae, Sarocladium oryzae, and Ephelis sp., owing to strategic primer mismatches. This robust, pin-actuated, valve-free system highlights the potential for reliable, low-power, field-deployable nucleic acid diagnostics in point-of-care settings. While this study serves primarily as a hardware engineering proof-of-concept focusing on pump-free fluidic transportation, it establishes a foundational architecture for decentralized molecular diagnostics. Future translational development will focus on integrating raw matrix sample preparation to bypass the current limitation of requiring purified nucleic acid inputs. Graphic abstract
- 26 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (23)
Low-cost, real-time RPA platform integrating a PMMA microfluidic chip and spectral sensor for rapid on-site authentication of porcine DNA
Accurate species authentication of pork (Sus scrofa domesticus) is essential for food labeling integrity and religious dietary compliance. However, conventional PCR-based methods are hindered by bulky instrumentation and lengthy thermal cycling, limiting their point-of-need applicability. This study describes the development of a compact, low-cost (< 300 USD), real-time isothermal recombinase polymerase amplification (RPA) platform optimized for on-site porcine DNA detection. The device features a novel reaction chamber fabricated from polymethyl methacrylate (PMMA) via a rapid 5-minute milling process. To ensure efficient heat transfer, a high-thermal-conductivity grease (10 W/mK) is utilized at the heating interface, providing superior thermal contact and stability compared to traditional PDMS-based microfluidics. For signal transduction, an integrated AS7262 spectral sensor provides high-sensitivity digital fluorescence monitoring at 500 nm, utilizing a 488 nm ice-blue laser and a 90° orthogonal optical geometry to minimize background scatter. Operating at a constant 37 °C maintained by a PI control algorithm, the system—coupled with a rapid 10-minute thermal extraction protocol for pork meats—achieves a total turnaround time of 30 minutes. The platform demonstrates a limit of detection (LOD) of 1 pg/µL, with a linear correlation (R2 = 0.9014) between the Time-to-Threshold and the log-transformed DNA concentration. The total sample-to-result time for complex processed meat matrices is established at 45-50 minutes due to matrix-induced kinetic delays. Successful validation via gel electrophoresis confirmed a specific 152 bp amplification product. By bridging the gap between sophisticated laboratory analysis and field-based inspection, this integrated platform offers a robust, cost-effective solution for rapid meat speciation and global food supply chain monitoring.
- 26 May 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (23)
Low-cost, real-time RPA platform integrating a PMMA microfluidic chip and spectral sensor for rapid on-site authentication of porcine DNA
Accurate species authentication of pork (Sus scrofa domesticus) is essential for food labeling integrity and religious dietary compliance. However, conventional PCR-based methods are hindered by bulky instrumentation and lengthy thermal cycling, limiting their point-of-need applicability. This study describes the development of a compact, low-cost (< 300 USD), real-time isothermal recombinase polymerase amplification (RPA) platform optimized for on-site porcine DNA detection. The device features a novel reaction chamber fabricated from polymethyl methacrylate (PMMA) via a rapid 5-minute milling process. To ensure efficient heat transfer, a high-thermal-conductivity grease (10 W/mK) is utilized at the heating interface, providing superior thermal contact and stability compared to traditional PDMS-based microfluidics. For signal transduction, an integrated AS7262 spectral sensor provides high-sensitivity digital fluorescence monitoring at 500 nm, utilizing a 488 nm ice-blue laser and a 90° orthogonal optical geometry to minimize background scatter. Operating at a constant 37 °C maintained by a PI control algorithm, the system—coupled with a rapid 10-minute thermal extraction protocol for pork meats—achieves a total turnaround time of 30 minutes. The platform demonstrates a limit of detection (LOD) of 1 pg/µL, with a linear correlation (R2 = 0.9014) between the Time-to-Threshold and the log-transformed DNA concentration. The total sample-to-result time for complex processed meat matrices is established at 45-50 minutes due to matrix-induced kinetic delays. Successful validation via gel electrophoresis confirmed a specific 152 bp amplification product. By bridging the gap between sophisticated laboratory analysis and field-based inspection, this integrated platform offers a robust, cost-effective solution for rapid meat speciation and global food supply chain monitoring.
- 22 April 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 715, 116136
Deep learning-enabled ratiometric signal transduction for portable and intelligent colorimetric LAMP biosensing of Vibrio vulnificus
- 22 April 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 715, 116136
Deep learning-enabled ratiometric signal transduction for portable and intelligent colorimetric LAMP biosensing of Vibrio vulnificus
- 7 March 2026
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (11) , 643
Polymerase Chain Reaction (PCR) Detection of Salmonella spp. and Vibrio cholerae in Refilled Drinking Water in Malang City, Indonesia
- 7 March 2026
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 237 (11) , 643
Polymerase Chain Reaction (PCR) Detection of Salmonella spp. and Vibrio cholerae in Refilled Drinking Water in Malang City, Indonesia
- 10 February 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (9) , 1851-1869
A Wi-Fi-enabled, automated device for pathogen detection via LAMP and paper-based colorimetric assay
A Wi-Fi-enabled automated microfluidic device integrates DNA extraction, wax-triggered LAMP amplification, and paper-based colorimetric detection for rapid, portable identification of Vibrio vulnificus at the point of care.
- 10 February 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (9) , 1851-1869
A Wi-Fi-enabled, automated device for pathogen detection via LAMP and paper-based colorimetric assay
A Wi-Fi-enabled automated microfluidic device integrates DNA extraction, wax-triggered LAMP amplification, and paper-based colorimetric detection for rapid, portable identification of Vibrio vulnificus at the point of care.
- 30 January 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 712, 116064
Development of LMW chitosan-stabilized gold nanoparticle DNA biosensors functionalized with thiolated probe for Vibrio parahaemolyticus detection
- 30 January 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 712, 116064
Development of LMW chitosan-stabilized gold nanoparticle DNA biosensors functionalized with thiolated probe for Vibrio parahaemolyticus detection
- 18 July 2025
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (10) , 2943-2960
WACAN chip: a MEMS-based microfluidic PCR platform with integrated micro-heaters and liquid cold plate for efficient nucleic acid amplification
- 18 July 2025
- Published by Springer Nature in Microsystem Technologies
- Vol. 31 (10) , 2943-2960
WACAN chip: a MEMS-based microfluidic PCR platform with integrated micro-heaters and liquid cold plate for efficient nucleic acid amplification
- 16 January 2025
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 17 (3) , 1-24
A Radiation Heating-Based Oscillatory Polymerase Chain Reaction System for Detecting Donkey-Hide Gelatin
Polymerase chain reaction (PCR) is a biochemical technique for copying DNA by repeatedly changing the temperature of nucleic acid samples. In this study, we aim to create an oscillatory PCR system with a short reaction time, which could have significant practical implications. The device uses an electromechanical module with a servo motor and a homemade heating–cooling system that combines a halogen lamp, a Peltier element, a cooling fin, and a blower fan. We code the motor program to control the reaction chamber moving back and forth in the infrared thermal cycling system. The system uses one infrared lamp for heating and one Peltier element/thermal dissipation fins/blower fan for cooling to shorten the overall reaction time of the thermal process. Results show that using the radiant heating and convection cooling method and a micro-sample of 10 μL to perform a PCR, the total time spent is 35 min, which saves about 1 h compared to commercially available PCR instruments. The proposed PCR approach could specifically detect donkey-hide gelatin (DHG) made from donkey skin, offering a rapid and cost-effective solution. Therefore, our device has the advantages of easy manufacturing, low cost, and rapid temperature ramping rate for PCR.
- 16 January 2025
- Published by ASME International in Journal of Thermal Science and Engineering Applications
- Vol. 17 (3) , 1-24
A Radiation Heating-Based Oscillatory Polymerase Chain Reaction System for Detecting Donkey-Hide Gelatin
Polymerase chain reaction (PCR) is a biochemical technique for copying DNA by repeatedly changing the temperature of nucleic acid samples. In this study, we aim to create an oscillatory PCR system with a short reaction time, which could have significant practical implications. The device uses an electromechanical module with a servo motor and a homemade heating–cooling system that combines a halogen lamp, a Peltier element, a cooling fin, and a blower fan. We code the motor program to control the reaction chamber moving back and forth in the infrared thermal cycling system. The system uses one infrared lamp for heating and one Peltier element/thermal dissipation fins/blower fan for cooling to shorten the overall reaction time of the thermal process. Results show that using the radiant heating and convection cooling method and a micro-sample of 10 μL to perform a PCR, the total time spent is 35 min, which saves about 1 h compared to commercially available PCR instruments. The proposed PCR approach could specifically detect donkey-hide gelatin (DHG) made from donkey skin, offering a rapid and cost-effective solution. Therefore, our device has the advantages of easy manufacturing, low cost, and rapid temperature ramping rate for PCR.
- 11 July 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 694, 115615
Portable loop-mediated isothermal amplification device with spectrometric detection for rapid pathogen identification
- 11 July 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 694, 115615
Portable loop-mediated isothermal amplification device with spectrometric detection for rapid pathogen identification