Luigi Vito Stefanelli has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Guided Zygomatic Implantology for Oral Cancer Rehabilitation: A Case Report

    by Francesco Grecchi, Roberto Giuseppe D’ambrogio, Luigi Vito Stefanelli, Fabrizio Grivetto, Funda Goker, Massimo Del Fabbro, Alberto Schreiber, Cesare Piazza, Stefano Salgarello, Camilla Dosio, et al.

    Oral rehabilitation after maxillary oncological resection is challenging. This case report presents the rehabilitation of a 65-year-old Caucasian male adenoid cystic carcinoma patient using a myo-cutaneous thigh flap, zygomatic implant placement, and an immediate fixed provisional prosthesis made with computer-aided technologies. The patient presented complaints of asymptomatic enlarged swelling of 5-mm on the right hard hemi-palate. There was an oro-antral communication deriving from a previous local excision. Preoperative radiographs showed the involvement of the right maxilla, maxillary sinus, and nose with a suspect involvement of the maxillary division of the trigeminal nerve. Treatment was planned through a fully digital workflow. A partial maxillectomy was performed endoscopically, and maxilla was reconstructed using an anterolateral thigh free flap. Two zygomatic implants were inserted simultaneously. A provisional fix full-arch prosthesis was manufactured preoperatively through a fully digital workflow and was placed in the operating room. Following post-operative radiotherapy, the patient received a final hybrid prosthesis. During the follow-up period of two years, the patient reported good function, aesthetics, and significant enhancement in quality of life. According to the results of this case, the protocol represented can be a promising alternative for oral cancer patients with large defects, and can lead to an improved quality of life.


  • Open Access

    Zygomatic Implant Insertion in MRONJ: A Case Report with a Follow-Up of 3 Years

    by Funda Goker, Emma Grecchi, Massimo Del Fabbro, Salvatore Longoni, Luigi Vito Stefanelli, Francesco Grecchi

    The oral rehabilitation of MRONJ patients represents a challenging situation. Conventional dental implant insertion is not indicated because of the risk of creating a new necrotic area. This case study describes the oral rehabilitation of a 78-year-old female patient, who developed an osteonecrotic lesion in the fourth year of bisphosphonate treatment. The patient underwent a series of surgeries, including resection of the necrotic tissue on the right maxillary region and removal of conventional implants. The patient had a large maxillary defect, and no other treatment modalities such as conventional prosthetic appliances and traditional dental implant insertions were applicable. The patient had a very poor quality of life and as a rehabilitation option, two zygomatic implant insertions were planned and performed as an anchorage for maxillary fixed prosthesis. Radiographic and clinical examination after three years of follow-up indicated that healing was achieved, and healthy tissues formed around zygomatic implants. The patient did not suffer from any additional necrotic tissues or other complications in the oral cavity. According to the results of this case report, zygomatic implantation after resective surgery might be considered as a promising alternative for MRONJ patients with large defects when other treatment alternatives fail or are not applicable.


  • Open Access

    Relevance of the Operator’s Experience in Conditioning the Static Computer-Assisted Implantology: A Comparative In Vitro Study with Three Different Evaluation Methods

    by Gerardo Pellegrino, Giuseppe Lizio, Filippo D’errico, Agnese Ferri, Annalisa Mazzoni, Federico Del Bianco, Luigi Vito Stefanelli, Pietro Felice

    The present study aimed to evaluate the influence of manual expertise on static computer-aided implantology (s-CAI) in terms of accuracy and operative timings. After the cone-beam CT (CBCT) scanning of eleven mandibular models, a full-arch rehabilitation was planned, and two different skilled operators performed s-CAI. The distances between the virtual and actual implant positions were calculated considering the three spatial vectorial axes and the three-dimensional Euclidean value for the entry (E) and apical (A) points, along with the axis orientation differences (Ax). These values emerged from the overlapping of the pre-op CBCT to post-op CBCT data (method 1), from scanning the data from the laboratory scanner (method 2), and from the intra-oral scanner (method 3) and were correlated with the operators’ expertise and operative timings. The mean values for accuracy from the three methods were: E = 0.57 (0.8, 0.45, 0.47) mm, A = 0.6 (0.8, 0.48, 0.49) mm, and Ax 1.04 (1.05,1.03,1.05) ° for the expert operator; and E = 0.8 (0.9, 0.87, 0.77), A = 0.95 (1.02, 0.95, 0.89), and Ax =1.64 (1.78, 1.58, 1.58) for the novice. The mean value of the operative timings was statistically inferior for the expert operator (p < 0.05), with an improved accuracy over time for both operators. A significant difference (p < 0.05) emerged between method 1 and methods 2 and 3 for seven of the nine variables, without differences between the evaluations from the two scanners. The support from digital surgical guides does not eliminate the importance of manual expertise for the reliability and the shortening of the surgical procedure, and it requires a learning pathway over time.


  • Open Access

    A novel guided zygomatic implant surgery system compared to free hand: A human cadaver study on accuracy

    by E. Grecchi, L.V. Stefanelli, F. Grecchi, F. Grivetto, A. Franchina, N. Pranno


  • Open Access

    Artificial Intelligence: A New Diagnostic Software in Dentistry: A Preliminary Performance Diagnostic Study

    by Francesca De Angelis, Nicola Pranno, Alessio Franchina, Stefano Di Carlo, Edoardo Brauner, Agnese Ferri, Gerardo Pellegrino, Emma Grecchi, Funda Goker, Luigi Vito Stefanelli

    Background: Artificial intelligence (AI) has taken hold in public health because more and more people are looking to make a diagnosis using technology that allows them to work faster and more accurately, reducing costs and the number of medical errors. Methods: In the present study, 120 panoramic X-rays (OPGs) were randomly selected from the Department of Oral and Maxillofacial Sciences of Sapienza University of Rome, Italy. The OPGs were acquired and analyzed using Apox, which takes a panoramic X-rayand automatically returns the dental formula, the presence of dental implants, prosthetic crowns, fillings and root remnants. A descriptive analysis was performed presenting the categorical variables as absolute and relative frequencies. Results: In total, the number of true positive (TP) values was 2.195 (19.06%); true negative (TN), 8.908 (77.34%); false positive (FP), 132 (1.15%); and false negative (FN), 283 (2.46%). The overall sensitivity was 0.89, while the overall specificity was 0.98. Conclusions: The present study shows the latest achievements in dentistry, analyzing the application and credibility of a new diagnostic method to improve the work of dentists and the patients’ care.


  • Open Access

    Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy?

    by Luigi Vito Stefanelli, Alessio Franchina, Andrea Pranno, Gerardo Pellegrino, Agnese Ferri, Nicola Pranno, Stefano Di Carlo, Francesca De Angelis

    Objectives: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. Methods: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different tips and two different scan strategies) with the scan dataset made with lab scanning, and the values of the (90°–10°)/2 method were reported. Precision was evaluated by using the same values of trueness coming from the intra-group overlapping (scan dataset made with an IOS overlapped and compared to each other). Moreover, two different software programs of overlapping were used to calculate accuracy values. Results: The mean difference of trueness was 26.61 ± 5.07 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 37.99 ± 4.94 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 51.22 ± 6.57 µm with a new strategy of intraoral scanning and using the old design of the tip. The mean difference of precision was 23.57 ± 5.77 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 38.34 ± 11.39 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 46.93 ± 7.15 µm with a new strategy of intraoral scanning and using the old design of the tip. No difference was found in the trueness and precision data extracted using the two different programs of superimposition Geomagic Control X and Medit Compare. Conclusions: The outcomes of this study showed that the latest version of I-Medit 500 with the use of a new tip seems to be promising in terms of accuracy when a full arch needs to be scanned. Moreover, Medit Compare, which is an application of Medit IOS software, can be used to calculate IOS accuracy.


  • Open Access

    A 4 mm-Long Implant Rehabilitation in the Posterior Maxilla with Dynamic Navigation Technology: A Case Report after a Three-Years Post-Loading Follow-Up

    by Gerardo Pellegrino, Giuseppe Lizio, Fabio Rossi, Lorenzo Tuci, Lorenzo Ferraioli, Luigi Vito Stefanelli, Stefano Di Carlo, Francesca De Angelis

    The use of short (<8 mm long) and ultra-short (<6 mm long) implants allows the prosthetic rehabilitation of the posterior ridges of the jaws avoiding reconstructive procedures. Nevertheless, this approach requires vast experience to ensure the primary stability of the fixture in a correct position. Computer-aided implantology (CAI) achieves better results than the free-hand one in terms of placement accuracy, reducing the surgical risks and the operative timings. Dynamic navigation (DN) allows the surgeon to track the position and movements of the drill in real-time on the CT imaging data set. It is more versatile than the computed static system, enabling the operator to change the guidance coordinates according to the intra-operative feedbacks. A mono-edentulous upper right first molar site was rehabilitated with a four mm-long implant to avoid reconstructive techniques, drastically rejected by the patients. The case was managed within a DN protocol considering the minimal available bone and the prosthetic demands. The phases of this procedure were strictly documented up to a 3-year follow-up. No intra-operative problems occurred, and adequate primary stability of the implant was obtained. The prosthetic loading was carried out within only six weeks without any complications. No variation of the baseline clinical scenario as evidenced clinically and radiographically at the end of follow-up. No similar cases are reported in the literature.


  • Open Access

    Full Zirconia Implant-Born Prosthetic Rehabilitation with CAD/CAM Technology after Accurate Digital Planning. A Case Report

    by Riccardo Scaringi, Michele Nannelli, Alessio Franchina, Giuseppe Lizio, Luigi V. Stefanelli, Michele Pagliarulo, Francesca De Angelis, Gerardo Pellegrino

    CAD/CAM technology can enhance the dentistry application of ceramic materials that meet the more relevant biocompatibility and aesthetics demands. In implant-borne prosthesis rehabilitation, yttria-stabilized zirconia appeared to be a valid alternative to metal-alloys and titanium, with comparable mechanical properties and even better interaction with bone and soft tissues. The improvement of monolithic CAD/CAM manufacturing allows for a reliable, predictable, and rapid workflow that can correspond to a holistic treatment philosophy associated with zirconia fixtures. This reported clinical case highlights the advantages of this approach in resolving particularly functionally and aesthetically complex situations. A 40-year-old patient with permanent canine impaction and the persistence of a deciduous tooth compromised by caries was successfully rehabilitated with the surgical removal of the enclosed tooth, the seating of a mono-phase zirconia implant after the deciduous extraction and its loading with a zirconia single crown, without any clinical or radiographical alteration up to seven years follow-up.


  • Open Access

    A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy

    by Francesco Grecchi, Luigi V. Stefanelli, Fabrizio Grivetto, Emma Grecchi, Rami Siev, Ziv Mazor, Massimo Del Fabbro, Nicola Pranno, Alessio Franchina, Vittorio Di Lucia, et al.

    The aim of this human cadaver study was to assess the accuracy of zygomatic/pterygoid implant placement using custom-made bone-supported laser sintered titanium templates. For this purpose, pre-surgical planning was done on computed tomography scans of each cadaver. Surgical guides were printed using direct metal laser sintering technology. Four zygomatic and two pterygoid implants were inserted in each case using the guided protocol and related tools. Post-operative computed tomography (CT) scans were obtained to evaluate deviations between the planned and inserted implants. Accuracy was measured by overlaying the real position in the post-operative CT on the virtual presurgical placement of the implant in a CT image. Descriptive and bivariate analyses of the data were performed. As a result, a total of 40 zygomatic and 20 pterygoid implants were inserted in 10 cadavers. The mean deviations between the planned and the placed zygomatic and pterygoid implants were respectively (mean ± SD): 1.69° ± 1.12° and 4.15° ± 3.53° for angular deviation. Linear distance deviations: 0.93 mm ± 1.23 mm and 1.35 mm ± 1.45 mm at platform depth, 1.35 mm ± 0.78 mm and 1.81 mm ± 1.47 mm at apical plane, 1.07 mm ± 1.47 mm and 1.22 mm ± 1.44 mm for apical depth. In conclusion, the surgical guide system showed accuracy for all the variables studied and allowed acceptable and accurate implant placement regardless of the case complexity.


  • Open Access

    Digital Approach for the Rehabilitation of the Edentulous Maxilla with Pterygoid and Standard Implants: The Static and Dynamic Computer-Aided Protocols

    by Alessio Franchina, Luigi Vito Stefanelli, Simone Gorini, Simone Fedi, Giuseppe Lizio, Gerardo Pellegrino

    A full-arch rehabilitation of the edentulous upper jaw without grafting procedures exploits the residual alveolar or the basal bone, with the necessity of long implants placed with a particular orientation. The precision in planning and placing the fixtures is fundamental to avoid clinical problems and to allow an acceptable connection with the prosthesis. The computer-aided implantology resulted in more accuracy than the traditional one, with a high standard of correspondence between the virtual project and the real outcome. This paper reports about the two different digital protocols, static and dynamic, as support to implant-borne prosthetic rehabilitation of edentulous maxillae. Two pterygoid and two/four anterior standard implants were seated in both cases by two different operators, without flap raising, and immediately loaded. This approach avoided the posterior cantilever by-passing the maxillary sinus and was adequately planned and realized without any surgical or prosthetic error. The two digital flow-charts were described step by step, underlining each other’s advantages and drawbacks compared to a free-hand approach.