Andrew Phillip Moores
Research Subjects
Andrew Phillip Moores has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- James Grierson
Anderson Moores Veterinary Specialists part of Linnaeus Veterinary, Hursley Winchester Hampshire UK
6 shared publications Martin R. Owen
Dick White Referrals, Newmarket, UK
5 shared publications- Andrea Pratesi
Independent Researcher, 35121 Padova, Italy
4 shared publications Jeremy Onyett
Abington Park Referrals, The Holcot Centre Northampton UK
4 shared publicationsShane Morrison
Christchurch Veterinary Surgery Ipswich UK
4 shared publications- Alison L. Moores
Moores Soft Tissue Winchester UK
3 shared publications
Latest Publications
- Open Access
- 5 September 2022
- Published by Wiley in Veterinary Surgery
- Vol. 52 (2) , 196-208
Outcomes and complications reported from a multiuser canine hip replacement registry over a 10‐year period
Objective: To report outcomes and complications associated with total hip replacements (THR) using a multiuser canine hip registry (CHR) and owner‐administered questionnaire.Study design: Prospective longitudinal clinical study.Animals: Dogs (n = 1852).Methods: Total hip replacement cases submitted to a CHR were reviewed. An online questionnaire including an adapted “Liverpool Osteoarthritis in Dogs” (LOAD) score was e‐mailed to owners. Data were analyzed to determine associations between clinical variables and the agreement by veterinary surgeons and owners for complications.Results: A group of 1329 (72%) dogs had unilateral THRs and another group of 523 (28%) dogs had bilateral THRs, resulting in 2375 THRs. Indications included hip dysplasia and osteoarthritis (n = 2028/2375, 85%). Implants were manufactured by Kyon (n = 1087, 46%), BioMedtrix CFX (n = 514, 22%), BioMedtrix hybrid (n = 264, 11%), BioMedtrix BFX (n = 221, 9%), and Helica (n = 107, 4.5%). Median veterinary surgeon and owner follow up were 1328 and 900 days respectively. Postoperative LOAD scores (21 ± 9) reported by 461 owners improved compared to preoperative scores (11 ± 9) (P < .001). Veterinary surgeons reported complications in 201/2375 (8.5%) THRs and owners in 107/461 (23%) THRs, with moderate agreement (weighted kappa = 0.44). No associations were identified between complications and weight, age, sex, or breed. BioMedtrix BFX and Helica implants were associated with increased complications (P = .031) when used for revisions of femoral head and neck excisions.Conclusion: Excellent outcomes, including improved canine mobility, were reported after THRs. Complications were underreported by veterinary surgeons compared to owners in this first multiuser CHR.Clinical significance: Canine THRs are safe, effective procedures but THR implants should be carefully selected when revising femoral head and neck excisions.
- 5 September 2022
- Published by Wiley in Veterinary Surgery
- Vol. 52 (2) , 196-208
Open AccessOutcomes and complications reported from a multiuser canine hip replacement registry over a 10‐year period
Objective: To report outcomes and complications associated with total hip replacements (THR) using a multiuser canine hip registry (CHR) and owner‐administered questionnaire.Study design: Prospective longitudinal clinical study.Animals: Dogs (n = 1852).Methods: Total hip replacement cases submitted to a CHR were reviewed. An online questionnaire including an adapted “Liverpool Osteoarthritis in Dogs” (LOAD) score was e‐mailed to owners. Data were analyzed to determine associations between clinical variables and the agreement by veterinary surgeons and owners for complications.Results: A group of 1329 (72%) dogs had unilateral THRs and another group of 523 (28%) dogs had bilateral THRs, resulting in 2375 THRs. Indications included hip dysplasia and osteoarthritis (n = 2028/2375, 85%). Implants were manufactured by Kyon (n = 1087, 46%), BioMedtrix CFX (n = 514, 22%), BioMedtrix hybrid (n = 264, 11%), BioMedtrix BFX (n = 221, 9%), and Helica (n = 107, 4.5%). Median veterinary surgeon and owner follow up were 1328 and 900 days respectively. Postoperative LOAD scores (21 ± 9) reported by 461 owners improved compared to preoperative scores (11 ± 9) (P < .001). Veterinary surgeons reported complications in 201/2375 (8.5%) THRs and owners in 107/461 (23%) THRs, with moderate agreement (weighted kappa = 0.44). No associations were identified between complications and weight, age, sex, or breed. BioMedtrix BFX and Helica implants were associated with increased complications (P = .031) when used for revisions of femoral head and neck excisions.Conclusion: Excellent outcomes, including improved canine mobility, were reported after THRs. Complications were underreported by veterinary surgeons compared to owners in this first multiuser CHR.Clinical significance: Canine THRs are safe, effective procedures but THR implants should be carefully selected when revising femoral head and neck excisions.
- 1 June 2022
- Published by Wiley in Veterinary Surgery
- Vol. 51 (5) , 763-771
Long‐term follow up of 44 cats undergoing total hip replacement: Cases from a feline hip registry (2010‐2020)
Objective: To report indications, complications, and long‐term outcomes following feline total hip replacement (THR) using a client‐based clinical metrology questionnaire, the Feline Musculoskeletal Pain Index (FMPI), and owner satisfaction.Study design: Multi‐institutional retrospective cohort study.Animals: Cats (n = 44) that underwent THR (n = 56).Methods: Feline THRs submitted to a registry over a 10‐year period were reviewed. The FMPI and owner satisfaction surveys were used to assess outcome.Results: Forty‐four cats met the inclusion criteria. Median age was 2 years (range: 0.9‐11), and median bodyweight 5 kg (range: 3.3‐7.6). British Shorthair and Domestic Shorthair were the most frequent breeds. Most cats were neutered males (33/44) and slipped capital femoral epiphysis (SCFE) was the most common surgical indication (34/56). All implants were cemented micro and nano hip implants. Overall complications (11/56) included 9 major complications. The median duration of follow up was 752 days (range: 102‐3089). No association was found between clinical variables and complications. The FMPI score improved from 0.111 (range: 0‐1.222) to 2.111 (range: 0.888‐3.666) postoperatively (P < .001). Owner satisfaction was reported as “very good” in 30/33 cases (90.9%).Conclusion: A validated client metrology questionnaire showed clinical improvement in cats following THR. The most common indication for THR in cats was SCFE occurring in young male neutered cats. Complication rates were comparable to previous reports.Clinical significance: Total hip replacement appears to be a successful surgical treatment for feline hip disease with very good owner satisfaction and acceptable complication rates.
- 1 June 2022
- Published by Wiley in Veterinary Surgery
- Vol. 51 (5) , 763-771
Long‐term follow up of 44 cats undergoing total hip replacement: Cases from a feline hip registry (2010‐2020)
Objective: To report indications, complications, and long‐term outcomes following feline total hip replacement (THR) using a client‐based clinical metrology questionnaire, the Feline Musculoskeletal Pain Index (FMPI), and owner satisfaction.Study design: Multi‐institutional retrospective cohort study.Animals: Cats (n = 44) that underwent THR (n = 56).Methods: Feline THRs submitted to a registry over a 10‐year period were reviewed. The FMPI and owner satisfaction surveys were used to assess outcome.Results: Forty‐four cats met the inclusion criteria. Median age was 2 years (range: 0.9‐11), and median bodyweight 5 kg (range: 3.3‐7.6). British Shorthair and Domestic Shorthair were the most frequent breeds. Most cats were neutered males (33/44) and slipped capital femoral epiphysis (SCFE) was the most common surgical indication (34/56). All implants were cemented micro and nano hip implants. Overall complications (11/56) included 9 major complications. The median duration of follow up was 752 days (range: 102‐3089). No association was found between clinical variables and complications. The FMPI score improved from 0.111 (range: 0‐1.222) to 2.111 (range: 0.888‐3.666) postoperatively (P < .001). Owner satisfaction was reported as “very good” in 30/33 cases (90.9%).Conclusion: A validated client metrology questionnaire showed clinical improvement in cats following THR. The most common indication for THR in cats was SCFE occurring in young male neutered cats. Complication rates were comparable to previous reports.Clinical significance: Total hip replacement appears to be a successful surgical treatment for feline hip disease with very good owner satisfaction and acceptable complication rates.
- 5 April 2022
- Published by Wiley in Veterinary Surgery
- Vol. 51 (4) , 600-610
Medial epicondylar fissure fracture as a complication of transcondylar screw placement for the treatment of humeral intracondylar fissure
Objective: To report the incidence of medial epicondylar fissure fracture (MEFF) after medial‐to‐lateral transcondylar screw placement in dogs with humeral intracondylar fissure (HIF) and to identify risk factors for MEFF.Study design: Retrospective study.Sample population: Seventy‐four client‐owned dogs (88 elbows).Methods: Medical records of dogs surgically treated for HIF, and postoperative imaging studies were reviewed for demographics, fracture characteristics, and repair techniques. The width of the transcondylar screw was expressed relative to the height of the condyle. Screw angle and degree of countersinking were recorded. Information from case records and follow‐up radiographs were used to identify complications.Results: Medial epicondylar fissure fracture was identified in 10 elbows (11.4%) following medial‐to‐lateral transcondylar screw placement: 4 cases were detected intraoperatively, 2 on immediate postoperative radiographs, 1 during routine radiographic follow up, and 3 when radiographs were reviewed for this study. A larger relative screw size was found to increase the risk of MEFF (P = .004, OR = 1.5). Fifteen additional complications were identified in 13/80 elbows at a median of 6 weeks postoperatively (range 1–56 weeks). Screw loosening was the most frequent complication (n = 9) and was the only complication in dogs with MEFF (n = 3); MEFF tended to increase the risk of perioperative screw loosening (P = .06).Conclusion: Medial epicondylar fissure fracture occurred in 10/88 elbows treated for HIF and was more common in elbows treated with a larger screw size relative to the height of the condyle.Clinical significance: Placing transcondylar screws with a diameter inferior to 41% of the height of the condyle is recommended to avoid MEFF. Medial epicondylar fissure fracture appears to have a low clinical significance in the perioperative period, although its effect on long‐term outcome remains unknown.
- 5 April 2022
- Published by Wiley in Veterinary Surgery
- Vol. 51 (4) , 600-610
Medial epicondylar fissure fracture as a complication of transcondylar screw placement for the treatment of humeral intracondylar fissure
Objective: To report the incidence of medial epicondylar fissure fracture (MEFF) after medial‐to‐lateral transcondylar screw placement in dogs with humeral intracondylar fissure (HIF) and to identify risk factors for MEFF.Study design: Retrospective study.Sample population: Seventy‐four client‐owned dogs (88 elbows).Methods: Medical records of dogs surgically treated for HIF, and postoperative imaging studies were reviewed for demographics, fracture characteristics, and repair techniques. The width of the transcondylar screw was expressed relative to the height of the condyle. Screw angle and degree of countersinking were recorded. Information from case records and follow‐up radiographs were used to identify complications.Results: Medial epicondylar fissure fracture was identified in 10 elbows (11.4%) following medial‐to‐lateral transcondylar screw placement: 4 cases were detected intraoperatively, 2 on immediate postoperative radiographs, 1 during routine radiographic follow up, and 3 when radiographs were reviewed for this study. A larger relative screw size was found to increase the risk of MEFF (P = .004, OR = 1.5). Fifteen additional complications were identified in 13/80 elbows at a median of 6 weeks postoperatively (range 1–56 weeks). Screw loosening was the most frequent complication (n = 9) and was the only complication in dogs with MEFF (n = 3); MEFF tended to increase the risk of perioperative screw loosening (P = .06).Conclusion: Medial epicondylar fissure fracture occurred in 10/88 elbows treated for HIF and was more common in elbows treated with a larger screw size relative to the height of the condyle.Clinical significance: Placing transcondylar screws with a diameter inferior to 41% of the height of the condyle is recommended to avoid MEFF. Medial epicondylar fissure fracture appears to have a low clinical significance in the perioperative period, although its effect on long‐term outcome remains unknown.
- 15 December 2021
- Published by Wiley in Journal of Small Animal Practice
- Vol. 63 (4) , 305-311
Surgical management of superficial digital flexor tendon luxation in dogs: 48 cases (2005‐2020)
Objectives: To report the outcome, frequency of complications and potential prognostic factors associated with surgical repair of superficial digital flexor tendon (SDFT) luxation in dogs.Materials and Methods: Medical records from 10 referral hospitals were reviewed retrospectively for cases of SDFT luxation in dogs that underwent surgical stabilisation. Signalment, clinical presentation, diagnostic imaging, surgical method, type and length of post‐operative limb immobilisation, nature of and length of exercise restriction, presence of post‐operative complications and outcomes were recorded. Data were summarised descriptively and prognostic risk factors assessed for association with surgical outcome using risk ratios.Results: Forty‐eight cases were included. A successful surgical outcome was recorded in 35 of 48 (73%) cases.Re‐luxation of the SDFT occurred in seven of 48 (15%). Six out of 48 (13%) had a persistent lameness despite a stable non‐luxating SDFT. A high frequency of post‐operative complications occurred (71%), with the majority resolved medically. The risk of surgical failure was 60% higher (risk ratio 1.6, 95% confidence interval 1.1 to 2.4) where absorbable suture material was used compared to non‐absorbable suture material. Surgical failure was more common in cases managed with non‐rigid immobilisation post‐operatively (57% failure) compared to cases managed with rigid immobilisation (19% failure), although this result was not statistically significant. Limb immobilisation of 6 weeks or longer did not significantly affect surgical outcome, compared to shorter periods of exercise restriction or limb immobilisation.Clinical Significance: A good outcome can be expected following surgical stabilisation of SDFT luxation. The use of non‐absorbable suture was associated with a more successful surgical outcome.
- 15 December 2021
- Published by Wiley in Journal of Small Animal Practice
- Vol. 63 (4) , 305-311
Surgical management of superficial digital flexor tendon luxation in dogs: 48 cases (2005‐2020)
Objectives: To report the outcome, frequency of complications and potential prognostic factors associated with surgical repair of superficial digital flexor tendon (SDFT) luxation in dogs.Materials and Methods: Medical records from 10 referral hospitals were reviewed retrospectively for cases of SDFT luxation in dogs that underwent surgical stabilisation. Signalment, clinical presentation, diagnostic imaging, surgical method, type and length of post‐operative limb immobilisation, nature of and length of exercise restriction, presence of post‐operative complications and outcomes were recorded. Data were summarised descriptively and prognostic risk factors assessed for association with surgical outcome using risk ratios.Results: Forty‐eight cases were included. A successful surgical outcome was recorded in 35 of 48 (73%) cases.Re‐luxation of the SDFT occurred in seven of 48 (15%). Six out of 48 (13%) had a persistent lameness despite a stable non‐luxating SDFT. A high frequency of post‐operative complications occurred (71%), with the majority resolved medically. The risk of surgical failure was 60% higher (risk ratio 1.6, 95% confidence interval 1.1 to 2.4) where absorbable suture material was used compared to non‐absorbable suture material. Surgical failure was more common in cases managed with non‐rigid immobilisation post‐operatively (57% failure) compared to cases managed with rigid immobilisation (19% failure), although this result was not statistically significant. Limb immobilisation of 6 weeks or longer did not significantly affect surgical outcome, compared to shorter periods of exercise restriction or limb immobilisation.Clinical Significance: A good outcome can be expected following surgical stabilisation of SDFT luxation. The use of non‐absorbable suture was associated with a more successful surgical outcome.
- 27 September 2021
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 34 (06) , 419-426
Repair of Fractures of the Lateral Aspect of the Humeral Condyle in Skeletally Mature Dogs with Locking and Non-Locking Plates
Objective The aim of this study was to report the functional outcome and complications following transcondylar screw and epicondylar plate fixation of skeletally mature dogs with fractures of the lateral aspect of the humeral condyle using a string of pearls, limited contact dynamic compression plate (LC-DCP) or locking compression plate (LCP). Study Design This study was a retrospective review of clinical records, radiographic images and canine brief pain inventory evaluation with a supplementary non-validated questionnaire. Results Thirty-one fractures in 29 dogs were included. The majority of dogs were Spaniels (23/29). Thirty fractures had evidence of humeral intracondylar fissure. Sixteen fractures had string of pearls, eight LCP and seven LC-DCP. There were two minor complications and three major complications. Perioperative (median: 6 weeks, range: 6–12) outcome was considered fully functional for 24 fractures and acceptable for 6 fractures. One dog had an unacceptable outcome due to the failure of an LCP that healed following revision surgery. Fractures with radiographic follow-up had a persistent visible intracondylar fracture line in 20/26. Twenty-six of twenty-seven owners perceived an excellent outcome (median: 135 weeks, range: 25–246). Conclusion Repair of fractures of the lateral aspect of the humeral condyle with a transcondylar screw and epicondylar plate has a good perioperative, mid- and long-term outcome with 10% major complication rate, despite incomplete or non-union of the intracondylar fracture in 20/26 elbows.
- 27 September 2021
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 34 (06) , 419-426
Repair of Fractures of the Lateral Aspect of the Humeral Condyle in Skeletally Mature Dogs with Locking and Non-Locking Plates
Objective The aim of this study was to report the functional outcome and complications following transcondylar screw and epicondylar plate fixation of skeletally mature dogs with fractures of the lateral aspect of the humeral condyle using a string of pearls, limited contact dynamic compression plate (LC-DCP) or locking compression plate (LCP). Study Design This study was a retrospective review of clinical records, radiographic images and canine brief pain inventory evaluation with a supplementary non-validated questionnaire. Results Thirty-one fractures in 29 dogs were included. The majority of dogs were Spaniels (23/29). Thirty fractures had evidence of humeral intracondylar fissure. Sixteen fractures had string of pearls, eight LCP and seven LC-DCP. There were two minor complications and three major complications. Perioperative (median: 6 weeks, range: 6–12) outcome was considered fully functional for 24 fractures and acceptable for 6 fractures. One dog had an unacceptable outcome due to the failure of an LCP that healed following revision surgery. Fractures with radiographic follow-up had a persistent visible intracondylar fracture line in 20/26. Twenty-six of twenty-seven owners perceived an excellent outcome (median: 135 weeks, range: 25–246). Conclusion Repair of fractures of the lateral aspect of the humeral condyle with a transcondylar screw and epicondylar plate has a good perioperative, mid- and long-term outcome with 10% major complication rate, despite incomplete or non-union of the intracondylar fracture in 20/26 elbows.
- 1 March 2021
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 51 (2) , 421-437
Humeral Intracondylar Fissure in Dogs
- 1 March 2021
- Published by Elsevier in Veterinary Clinics of North America: Small Animal Practice
- Vol. 51 (2) , 421-437
Humeral Intracondylar Fissure in Dogs
- Open Access
- 27 January 2018
- Published by Wiley in Veterinary Record
- Vol. 182 (4) , 108
Complications and outcomes associated with 13 cases of triceps tendon disruption in dogs and cats (2003–2014)
This study reports data from a larger number of cases of triceps tendon disruption. Records from 10 veterinary referral hospitals between 2003 and 2014 were searched for canine and feline cases diagnosed with triceps tendon disruption, based on orthopaedic examination confirmed during surgery. Long‐term follow‐up and owner satisfaction were assessed using a questionnaire. There were 13 cases of triceps tendon disruption diagnosed across seven hospitals (nine dogs, four cats). Trauma, history or presence of a wound, surgery in the region of tendon attachment or corticosteroid treatment preceded triceps tendon disruption. Radiographic signs or histopathology suggestive of a chronic tendinopathy was common. All cases underwent surgical repair involving a tendon suture pattern, 12 of which were secured through bone tunnels. Immobilisation was used in all cases in the form of transarticular external skeletal fixation (TAESF) (8/9 dogs) or spica splint (four cats, two dogs; in one dog a TAESF was applied after complications associated with the spica splint). Complications occurred in 11 cases (17 total complications), frequently associated with the immobilisation method. One case had traumatic tendon rerupture two years following surgery. A wound at presentation was associated with the development of multiple complications. Nine cases had long‐term follow‐up; five achieved normal function, four achieved acceptable function. Despite the complications, overall return to subjective normal or acceptable function, as assessed by the owners, was achieved in the majority of cases.
- 27 January 2018
- Published by Wiley in Veterinary Record
- Vol. 182 (4) , 108
Open AccessComplications and outcomes associated with 13 cases of triceps tendon disruption in dogs and cats (2003–2014)
This study reports data from a larger number of cases of triceps tendon disruption. Records from 10 veterinary referral hospitals between 2003 and 2014 were searched for canine and feline cases diagnosed with triceps tendon disruption, based on orthopaedic examination confirmed during surgery. Long‐term follow‐up and owner satisfaction were assessed using a questionnaire. There were 13 cases of triceps tendon disruption diagnosed across seven hospitals (nine dogs, four cats). Trauma, history or presence of a wound, surgery in the region of tendon attachment or corticosteroid treatment preceded triceps tendon disruption. Radiographic signs or histopathology suggestive of a chronic tendinopathy was common. All cases underwent surgical repair involving a tendon suture pattern, 12 of which were secured through bone tunnels. Immobilisation was used in all cases in the form of transarticular external skeletal fixation (TAESF) (8/9 dogs) or spica splint (four cats, two dogs; in one dog a TAESF was applied after complications associated with the spica splint). Complications occurred in 11 cases (17 total complications), frequently associated with the immobilisation method. One case had traumatic tendon rerupture two years following surgery. A wound at presentation was associated with the development of multiple complications. Nine cases had long‐term follow‐up; five achieved normal function, four achieved acceptable function. Despite the complications, overall return to subjective normal or acceptable function, as assessed by the owners, was achieved in the majority of cases.
- 11 January 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (01) , 044-052
Single Transsacral Screw and Nut Stabilization of Bilateral Sacroiliac Luxation in 20 Cats
Objective This article aims to describe the use of a single transsacral screw and nut in a cohort of cats with bilateral sacroiliac (SI) luxation and document its radiographic and clinical outcome. Methods Medical records and radiographic studies of cats with bilateral SI luxation managed with a transsacral screw and nut stabilization were reviewed. Short-term follow-up included clinical examination and radiographs. Long-term follow-up was via owner questionnaire. Results Twenty consecutive cats with bilateral SI luxation were included. Six cats (35%) had additional musculoskeletal injuries that required stabilization. Luxations were stabilized with a single 2.7 cortical self-tapping transsacral screw and nylon nut (a metallic nut was used in one case). Postoperative radiographs confirmed SI reduction in all cats and a mean pelvic canal width ratio of 1.21 (a ratio of ≥1.1 was considered optimal). All cats available at follow-up examination were able to walk without signs of discomfort. Evaluation of follow-up radiographs showed maintenance of SI reduction and slight reduction of mean pelvic canal width ratio (1.18). Fourteen owner questionnaires were returned (median follow-up time of 40 months): nine cats were deemed to have normal activity and five cats were reported to have slight to mild reduced ability to jump or run. Clinical Significance The use of transsacral screw and nut stabilization of bilateral SI luxation in cats is a successful, repeatable and safe technique.
- 11 January 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (01) , 044-052
Single Transsacral Screw and Nut Stabilization of Bilateral Sacroiliac Luxation in 20 Cats
Objective This article aims to describe the use of a single transsacral screw and nut in a cohort of cats with bilateral sacroiliac (SI) luxation and document its radiographic and clinical outcome. Methods Medical records and radiographic studies of cats with bilateral SI luxation managed with a transsacral screw and nut stabilization were reviewed. Short-term follow-up included clinical examination and radiographs. Long-term follow-up was via owner questionnaire. Results Twenty consecutive cats with bilateral SI luxation were included. Six cats (35%) had additional musculoskeletal injuries that required stabilization. Luxations were stabilized with a single 2.7 cortical self-tapping transsacral screw and nylon nut (a metallic nut was used in one case). Postoperative radiographs confirmed SI reduction in all cats and a mean pelvic canal width ratio of 1.21 (a ratio of ≥1.1 was considered optimal). All cats available at follow-up examination were able to walk without signs of discomfort. Evaluation of follow-up radiographs showed maintenance of SI reduction and slight reduction of mean pelvic canal width ratio (1.18). Fourteen owner questionnaires were returned (median follow-up time of 40 months): nine cats were deemed to have normal activity and five cats were reported to have slight to mild reduced ability to jump or run. Clinical Significance The use of transsacral screw and nut stabilization of bilateral SI luxation in cats is a successful, repeatable and safe technique.
- 1 July 2017
- Published by Wiley in Veterinary Record
- Vol. 181 (1) , 18
Evaluation of variables influencing success and complication rates in canine total hip replacement: results from the British Veterinary Orthopaedic Association Canine Hip Registry (collation of data: 2010–2012)
The objective of this study was to assess the variables associated with complications of total hip replacement (THR) and report owner‐assessed outcomes. Entries into the British Veterinary Orthopaedic Association‐Canine Hip Registry (BVOA‐CHR) between September 2011 and December 2012 were reviewed separately and in conjunction with previous data (January 2010–August 2011). An outcomes assessment questionnaire was used to collect data from owners. Incidences of surgeon‐reported and owner‐reported complications were 8.2 per cent and 4.3 per cent, respectively. THR using the BioMedtrix BFX cup/stem prosthesis had a greater incidence of complications compared with THR using the BioMedtrix CFX cup/stem prosthesis (P=0.002); complications were 4.48 times more likely when using the BioMedtrix BFX cup/stem prosthesis versus the BioMedtrix CFX cup/stem prosthesis. THR using the BioMedtrix BFX cup/stem prosthesis had a higher incidence of complications compared with THR using a hybrid prosthesis (BioMedtrix BFX cup/CFX stem, BioMedtrix CFX cup/BFX stem) (P=0.046); complications were 2.85 times more likely when using the BioMedtrix BFX cup/stem prosthesis versus a hybrid prosthesis. In 95 per cent of cases, owner satisfaction with the outcome of THR was ‘very good’ or ‘good’. Complication rates from the BVOA‐CHR are similar to previous studies. The data suggest that prosthesis type is associated with complication rate, with BioMedtrix BFX (circa 2012) having a high short‐term complication rate.
- 1 July 2017
- Published by Wiley in Veterinary Record
- Vol. 181 (1) , 18
Evaluation of variables influencing success and complication rates in canine total hip replacement: results from the British Veterinary Orthopaedic Association Canine Hip Registry (collation of data: 2010–2012)
The objective of this study was to assess the variables associated with complications of total hip replacement (THR) and report owner‐assessed outcomes. Entries into the British Veterinary Orthopaedic Association‐Canine Hip Registry (BVOA‐CHR) between September 2011 and December 2012 were reviewed separately and in conjunction with previous data (January 2010–August 2011). An outcomes assessment questionnaire was used to collect data from owners. Incidences of surgeon‐reported and owner‐reported complications were 8.2 per cent and 4.3 per cent, respectively. THR using the BioMedtrix BFX cup/stem prosthesis had a greater incidence of complications compared with THR using the BioMedtrix CFX cup/stem prosthesis (P=0.002); complications were 4.48 times more likely when using the BioMedtrix BFX cup/stem prosthesis versus the BioMedtrix CFX cup/stem prosthesis. THR using the BioMedtrix BFX cup/stem prosthesis had a higher incidence of complications compared with THR using a hybrid prosthesis (BioMedtrix BFX cup/CFX stem, BioMedtrix CFX cup/BFX stem) (P=0.046); complications were 2.85 times more likely when using the BioMedtrix BFX cup/stem prosthesis versus a hybrid prosthesis. In 95 per cent of cases, owner satisfaction with the outcome of THR was ‘very good’ or ‘good’. Complication rates from the BVOA‐CHR are similar to previous studies. The data suggest that prosthesis type is associated with complication rate, with BioMedtrix BFX (circa 2012) having a high short‐term complication rate.
- 13 April 2017
- Published by Wiley in Journal of Small Animal Practice
- Vol. 58 (7) , 372-379
Treatment of tibial diaphyseal fractures following plateless tibial tuberosity advancement to manage cranial cruciate disease
- 13 April 2017
- Published by Wiley in Journal of Small Animal Practice
- Vol. 58 (7) , 372-379
Treatment of tibial diaphyseal fractures following plateless tibial tuberosity advancement to manage cranial cruciate disease