Andrea Brambilla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andrea Brambilla has a total of 346 co-authors. Here are the top co-authors by number of shared publications:
- Philippe Bergonzo
Electronic and Electrical Engineering Department, University College London, London WC1E 7JE, UK
29 shared publications D. Tromson
LETI/DEIN/SPE/CEA Saclay
13 shared publicationsF. Foulon
LIST, CEA-Recherche Technologique/DIMRI/SIAR, CEA/Saclay, 91191 Gif-sur-Yvette, France
13 shared publications- Alessandro Lo Giudice
Dipartimento di Fisica, Università degli Studi di Torino, via Pietro Giuria 1, 10125 Torino, Italy
12 shared publications - Mara Bruzzi
Department of Physics and Astronomy, University of Florence, Via G. Sansone 1, 50019 Firenze
12 shared publications F Foulon
LETI (CEA-Technologies Avancées)/DEIN/SPE, CEA/Saclay, 91191 Gif-sur-Yvette Cedex, France
11 shared publications
Latest Publications
- Open Access
- 16 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10357
Dismantling of Printed Circuit Boards Enabling Electronic Components Sorting and Their Subsequent Treatment Open Improved Elemental Sustainability Opportunities
This critical review focuses on advanced recycling strategies to enable or increase recovery of chemical elements present in waste printed circuit boards (WPCBs). Conventional recycling involves manual removal of high value electronic components (ECs), followed by raw crushing of WPCBs, to recover main elements (by weight or value). All other elements remain unrecovered and end up highly diluted in post-processing wastes or ashes. To retrieve these elements, it is necessary to enrich the waste streams, which requires a change of paradigm in WPCB treatment: the disassembly of WPCBs combined with the sorting of ECs. This allows ECs to be separated by composition and to drastically increase chemical element concentration, thus making their recovery economically viable. In this report, we critically review state-of-the-art processes that dismantle and sort ECs, including some unpublished foresight from our laboratory work, which could be implemented in a recycling plant. We then identify research, business opportunities and associated advanced retrieval methods for those elements that can therefore be recovered, such as refractory metals (Ta, Nb, W, Mo), gallium, or lanthanides, or those, such as the platinum group elements, that can be recovered in a more environmentally friendly way than pyrometallurgy. The recovery methods can be directly tuned and adapted to the corresponding stream.
- 16 September 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (18) , 10357
Open AccessDismantling of Printed Circuit Boards Enabling Electronic Components Sorting and Their Subsequent Treatment Open Improved Elemental Sustainability Opportunities
This critical review focuses on advanced recycling strategies to enable or increase recovery of chemical elements present in waste printed circuit boards (WPCBs). Conventional recycling involves manual removal of high value electronic components (ECs), followed by raw crushing of WPCBs, to recover main elements (by weight or value). All other elements remain unrecovered and end up highly diluted in post-processing wastes or ashes. To retrieve these elements, it is necessary to enrich the waste streams, which requires a change of paradigm in WPCB treatment: the disassembly of WPCBs combined with the sorting of ECs. This allows ECs to be separated by composition and to drastically increase chemical element concentration, thus making their recovery economically viable. In this report, we critically review state-of-the-art processes that dismantle and sort ECs, including some unpublished foresight from our laboratory work, which could be implemented in a recycling plant. We then identify research, business opportunities and associated advanced retrieval methods for those elements that can therefore be recovered, such as refractory metals (Ta, Nb, W, Mo), gallium, or lanthanides, or those, such as the platinum group elements, that can be recovered in a more environmentally friendly way than pyrometallurgy. The recovery methods can be directly tuned and adapted to the corresponding stream.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 528-536
An Efficient One-Step Method for Spectral CT Based on an Approximate Linear Model
Spectral computed tomography (spectral CT) is a medical and biomedical imaging technique which uses the spectral information of the attenuated X-ray beam. Energy-resolved photon-counting detector is a promising technique for improved spectral CT imaging and allows to obtain material selective images. Two different kind of approaches can be used to solve the problem of spectral reconstruction consisting of material decomposition and tomographic reconstruction: the “two steps” methods which are most often projection-based methods, and the “one step” methods. While the projection-based methods are interesting for the fast computational time, the one-step methods link directly the material image domain and the multienergy sinograms domain, which is an advantage to introduce spatial prior information in the material image domain. In this work we propose a proximal operator associated to a data fidelity term (based on an empirical linear forward model) for multimaterial decomposition. This proximal operator, which has a closed-form solution, makes it possible to propose fast regularized reconstruction methods for spectral CT, in particular for data of photon-counting detectors with many energy bins. We propose a one-step method based on the alternating direction method of multipliers (ADMM) and this proximal operator. We present promising results on dual material image reconstructions obtained from simulated and experimental data. We show qualitative and quantitative comparisons with two previously published multimaterial decomposition methods.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 528-536
An Efficient One-Step Method for Spectral CT Based on an Approximate Linear Model
Spectral computed tomography (spectral CT) is a medical and biomedical imaging technique which uses the spectral information of the attenuated X-ray beam. Energy-resolved photon-counting detector is a promising technique for improved spectral CT imaging and allows to obtain material selective images. Two different kind of approaches can be used to solve the problem of spectral reconstruction consisting of material decomposition and tomographic reconstruction: the “two steps” methods which are most often projection-based methods, and the “one step” methods. While the projection-based methods are interesting for the fast computational time, the one-step methods link directly the material image domain and the multienergy sinograms domain, which is an advantage to introduce spatial prior information in the material image domain. In this work we propose a proximal operator associated to a data fidelity term (based on an empirical linear forward model) for multimaterial decomposition. This proximal operator, which has a closed-form solution, makes it possible to propose fast regularized reconstruction methods for spectral CT, in particular for data of photon-counting detectors with many energy bins. We propose a one-step method based on the alternating direction method of multipliers (ADMM) and this proximal operator. We present promising results on dual material image reconstructions obtained from simulated and experimental data. We show qualitative and quantitative comparisons with two previously published multimaterial decomposition methods.
- 28 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11072, 64
A fast gradient-based algorithm for image reconstruction in inverse geometry CT architecture with sparse distributed sources
Conventional Cone Beam CT (CBCT) is composed of a single source and a large detector to aquire a full sinogram of the object. Multi-source inverse geometry CT system (IGCT) consists, for its part in using several sources and a small detector to acquire several partial sinograms of the object. For technological, financial and medical reasons the reduction of the number of sources and the reduction of the detector size are interesting but induce to solve an ill-posed and ill-conditionned problem. We propose a regularized iterative algorithm which is able to reconstruct the object volume from partial sinograms acquired with a an optimized multi-source IGCT system : we will demonstrate the performance of the proposed algorithm when we reduce the size of the detector and the number of sources. Realistically simulated CT data is reconstructed with the proposed algorithm and the results are compared to those obtained by filtered backprojection (FBP) and those obtained by a maximum likelihood estimation to show the impact of the regularization.
- 28 May 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11072, 64
A fast gradient-based algorithm for image reconstruction in inverse geometry CT architecture with sparse distributed sources
Conventional Cone Beam CT (CBCT) is composed of a single source and a large detector to aquire a full sinogram of the object. Multi-source inverse geometry CT system (IGCT) consists, for its part in using several sources and a small detector to acquire several partial sinograms of the object. For technological, financial and medical reasons the reduction of the number of sources and the reduction of the detector size are interesting but induce to solve an ill-posed and ill-conditionned problem. We propose a regularized iterative algorithm which is able to reconstruct the object volume from partial sinograms acquired with a an optimized multi-source IGCT system : we will demonstrate the performance of the proposed algorithm when we reduce the size of the detector and the number of sources. Realistically simulated CT data is reconstructed with the proposed algorithm and the results are compared to those obtained by filtered backprojection (FBP) and those obtained by a maximum likelihood estimation to show the impact of the regularization.
- 1 August 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (08) , P08022
An FPGA-based algorithm to correct the instability of high-resolution and high-flux X-ray spectroscopic imaging detectors
The emergence of CdTe Photon Counting Detectors (PCD) with energy discrimination capabilities opens up new perspectives in X-ray imaging. Medical and security applications require very high fluxes and consequently a very fast shaper in order to limit dead time losses due to pile-up. However, if the shaper is faster than the collection of the charges in the semiconductor, there is a loss of charge called ballistic deficit. Moreover, variations of the electrical field profile in the detector over time causes a change in the collection time of the charges. According to this, the response of the detector will be affected by these variations. The instability of the response is visible over time as a channel shift of the spectra, resulting in a false information of the photon energy. The aim of this work is to develop real-time digital algorithms implementable in an FPGA in order to correct these effects and to give a stable response of the detector at very high fluxes. The method has been tested with a 4 × 4 pixels detector (CdTe) of 3 mm thickness and 800 μm pitch which is able to measure transmitted X-ray spectra in the energy range of 20–160 kV on 256 energy bins. The detector is coupled with an innovative custom-designed digital readout electronics able to perform a fast digital signal processing for very high-fluxes measurements. The developed method was initially tested at low count rate with a 57Co and 241Am γ-ray sources. After this first validation, it was tested with an X-ray beam, with a counting rate up to ~2⋅106 c/s. With the characterization and the validation of this innovative algorithm we prove its ability in providing a stable response of the detector over time without losing on the energy resolution (~8% at 122 keV) and on the dead time (~70 ns).
- 1 August 2018
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 13 (08) , P08022
An FPGA-based algorithm to correct the instability of high-resolution and high-flux X-ray spectroscopic imaging detectors
The emergence of CdTe Photon Counting Detectors (PCD) with energy discrimination capabilities opens up new perspectives in X-ray imaging. Medical and security applications require very high fluxes and consequently a very fast shaper in order to limit dead time losses due to pile-up. However, if the shaper is faster than the collection of the charges in the semiconductor, there is a loss of charge called ballistic deficit. Moreover, variations of the electrical field profile in the detector over time causes a change in the collection time of the charges. According to this, the response of the detector will be affected by these variations. The instability of the response is visible over time as a channel shift of the spectra, resulting in a false information of the photon energy. The aim of this work is to develop real-time digital algorithms implementable in an FPGA in order to correct these effects and to give a stable response of the detector at very high fluxes. The method has been tested with a 4 × 4 pixels detector (CdTe) of 3 mm thickness and 800 μm pitch which is able to measure transmitted X-ray spectra in the energy range of 20–160 kV on 256 energy bins. The detector is coupled with an innovative custom-designed digital readout electronics able to perform a fast digital signal processing for very high-fluxes measurements. The developed method was initially tested at low count rate with a 57Co and 241Am γ-ray sources. After this first validation, it was tested with an X-ray beam, with a counting rate up to ~2⋅106 c/s. With the characterization and the validation of this innovative algorithm we prove its ability in providing a stable response of the detector over time without losing on the energy resolution (~8% at 122 keV) and on the dead time (~70 ns).
- 27 November 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (1) , 015008
Breast density and iodine quantification in spectral mammography
Breast density is known for being a parameter used in breast cancer risk models and might be measured during mammography exams. Automated methods based on grayscale values already exist, but they only allow a density estimation over the whole breast. Material decomposition approaches make it possible to define the breast density at each pixel based on a dual energy exposure. Furthermore, the use of contrast enhanced digital mammography exams is increasing and helps physicians to highlight blood vessels with higher permeability that may be related to malignant lesions. Nevertheless, this technique also requires two x-ray exposures. In this paper, we propose to take benefit of energy sensitive x-ray detectors that give access to several energy measurements in a single shot acquisition to both quantify breast density and iodine during a single mammography exam. To this purpose, a spectral mammography acquisition chain has been simulated and different material decomposition methods have been proposed and investigated using a simulated phantom under clinically achievable settings with an average absorbed dose by the mammary gland of 0.93 mGy (mimicking a 45 mm thick breast made of 50% fibroglandular tissue) using a 49 kVp with a tungsten anode, an inherent filtration of 0.8 mmBe and an additional filtration of 1.2 mmAl. Breast density is commonly defined as the ratio between glandular tissue and the sum of adipose and glandular tissues thicknesses. Standard polynomial material decomposition methods have been extended to make them compliant with 3-energy measurements in order to allow a three-material decomposition: adipose and glandular tissues as well as iodine concentration. Those methods allow to estimate iodine concentration with an average accuracy inferior to 0.15 mg ml −1 and breast density with a precision inferior to 8% (root-mean-square errors). Nevertheless, these methods are difficult to extend to more energy channels due to the least-square model inversion. To achieve better results, a maximum log-likelihood approach has been introduced to take into consideration more spectral information while improving accuracy and precision on measurements. Moreover, the use of the proposed method permits to accurately detect the absence of iodine and significantly improves the estimation of breast density compared to polynomial approaches. We also highlighted that there is a strong interest to increase the number of energy thresholds from 3 to 6, a less significant gain is still noticeable with more energy bins.
- 27 November 2017
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (1) , 015008
Breast density and iodine quantification in spectral mammography
Breast density is known for being a parameter used in breast cancer risk models and might be measured during mammography exams. Automated methods based on grayscale values already exist, but they only allow a density estimation over the whole breast. Material decomposition approaches make it possible to define the breast density at each pixel based on a dual energy exposure. Furthermore, the use of contrast enhanced digital mammography exams is increasing and helps physicians to highlight blood vessels with higher permeability that may be related to malignant lesions. Nevertheless, this technique also requires two x-ray exposures. In this paper, we propose to take benefit of energy sensitive x-ray detectors that give access to several energy measurements in a single shot acquisition to both quantify breast density and iodine during a single mammography exam. To this purpose, a spectral mammography acquisition chain has been simulated and different material decomposition methods have been proposed and investigated using a simulated phantom under clinically achievable settings with an average absorbed dose by the mammary gland of 0.93 mGy (mimicking a 45 mm thick breast made of 50% fibroglandular tissue) using a 49 kVp with a tungsten anode, an inherent filtration of 0.8 mmBe and an additional filtration of 1.2 mmAl. Breast density is commonly defined as the ratio between glandular tissue and the sum of adipose and glandular tissues thicknesses. Standard polynomial material decomposition methods have been extended to make them compliant with 3-energy measurements in order to allow a three-material decomposition: adipose and glandular tissues as well as iodine concentration. Those methods allow to estimate iodine concentration with an average accuracy inferior to 0.15 mg ml −1 and breast density with a precision inferior to 8% (root-mean-square errors). Nevertheless, these methods are difficult to extend to more energy channels due to the least-square model inversion. To achieve better results, a maximum log-likelihood approach has been introduced to take into consideration more spectral information while improving accuracy and precision on measurements. Moreover, the use of the proposed method permits to accurately detect the absence of iodine and significantly improves the estimation of breast density compared to polynomial approaches. We also highlighted that there is a strong interest to increase the number of energy thresholds from 3 to 6, a less significant gain is still noticeable with more energy bins.
- 1 September 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (9) , T09008
Characterization of spectrometric photon-counting X-ray detectors at different pitches
There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm2. Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 106 incident photons.s−1.mm−2.
- 1 September 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (9) , T09008
Characterization of spectrometric photon-counting X-ray detectors at different pitches
There is growing interest in energy-sensitive photon-counting detectors based on high flux X-ray imaging. Their potential applications include medical imaging, non-destructive testing and security. Innovative detectors of this type will need to count individual photons and sort them into selected energy bins, at several million counts per second and per mm2. Cd(Zn)Te detector grade materials with a thickness of 1.5 to 3 mm and pitches from 800 μm down to 200 μm were assembled onto interposer boards. These devices were tested using in-house-developed full-digital fast readout electronics. The 16-channel demonstrators, with 256 energy bins, were experimentally characterized by determining spectral resolution, count rate, and charge sharing, which becomes challenging at low pitch. Charge sharing correction was found to efficiently correct X-ray spectra up to 40 × 106 incident photons.s−1.mm−2.
- 1 August 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (08) , P08014
Basis material decomposition method for material discrimination with a new spectrometric X-ray imaging detector
- 1 August 2017
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 12 (08) , P08014
Basis material decomposition method for material discrimination with a new spectrometric X-ray imaging detector
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Bayesian tissue decomposition method for spectral mammography
Breast density evaluation is an active topic in the breast imaging field. This can be accurately measured separating fibroglandular tissue from adipose tissue using material decomposition techniques. In this work, we present a Bayesian approach, based on a Poisson maximum likelihood material decomposition method and that includes an adjustable prior, known from the compressed breast thickness during a screening exam. Since some density variations in biological tissues may appear and the measured compressed thickness is not perfectly known, the proposed method moderates the prior upon the confidence on the thickness value. This work on spectral mammography has been carried out with energy-sensitive photon counting detectors that allow multi-measurements from a single acquisition unlike dual-energy digital mammography. The proposed approach has been benchmarked with a maximum likelihood method through a simulation process that included a detector response function of 60 μm CdTe X-ray detector. Our method has been investigated in severe conditions such as contrast-enhanced mammography. Hence, a 3-material decomposition base has been used, made of PMMA, water (to mimic adipose and fibroglandular tissues) and iodine. A phantom mimicking breast densities ranging from 10% to 100% with an iodine concentration set to 7 mg/mL was used as test case. In our specific conditions (49 kVp tungsten anode, 5 mAs, mean glandular dose = 0.93 mGy, ROI = 1.04 mm 2 ), the Bayesian approach reduced bias and noise on both breast density and iodine concentrations. Finally, the error on iodine concentration was below 0.1 mg/mL and around 5% on breast density, that is 1.8 times lower compared to standard maximum likelihood approach.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Bayesian tissue decomposition method for spectral mammography
Breast density evaluation is an active topic in the breast imaging field. This can be accurately measured separating fibroglandular tissue from adipose tissue using material decomposition techniques. In this work, we present a Bayesian approach, based on a Poisson maximum likelihood material decomposition method and that includes an adjustable prior, known from the compressed breast thickness during a screening exam. Since some density variations in biological tissues may appear and the measured compressed thickness is not perfectly known, the proposed method moderates the prior upon the confidence on the thickness value. This work on spectral mammography has been carried out with energy-sensitive photon counting detectors that allow multi-measurements from a single acquisition unlike dual-energy digital mammography. The proposed approach has been benchmarked with a maximum likelihood method through a simulation process that included a detector response function of 60 μm CdTe X-ray detector. Our method has been investigated in severe conditions such as contrast-enhanced mammography. Hence, a 3-material decomposition base has been used, made of PMMA, water (to mimic adipose and fibroglandular tissues) and iodine. A phantom mimicking breast densities ranging from 10% to 100% with an iodine concentration set to 7 mg/mL was used as test case. In our specific conditions (49 kVp tungsten anode, 5 mAs, mean glandular dose = 0.93 mGy, ROI = 1.04 mm 2 ), the Bayesian approach reduced bias and noise on both breast density and iodine concentrations. Finally, the error on iodine concentration was below 0.1 mg/mL and around 5% on breast density, that is 1.8 times lower compared to standard maximum likelihood approach.
- 1 April 2015
- Published by Elsevier in Computers & Graphics
- Vol. 47, 123-134
Expressive seeding of multiple stream surfaces for interactive flow exploration
- 1 April 2015
- Published by Elsevier in Computers & Graphics
- Vol. 47, 123-134
Expressive seeding of multiple stream surfaces for interactive flow exploration
- 19 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9033, 90333I-90333I-10
Investigation of the polynomial approach for material decomposition in spectral X-ray tomography using an energy-resolved detector
- 19 March 2014
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9033, 90333I-90333I-10
Investigation of the polynomial approach for material decomposition in spectral X-ray tomography using an energy-resolved detector