José Cícero Dinato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
José Cícero Dinato has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Clarice Ferreira Sabino
Faculty of Dentistry, National University of Singapore, Singapore
1 shared publication - Flávio Rosa de Oliveira
Institute of Science and Technology, São Paulo State University (Unesp), São José dos Campos, São Paulo 12220690, Brazil
1 shared publication - João Paulo Mendes Tribst
Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam, and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, North Holland, The Netherlands
1 shared publication - Laís Regiane da Silva-Concílio
Universidade de Taubate
1 shared publication - Marco Antonio Bottino
Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication
Latest Publications
- Open Access
Survival Rate and Deformation of External Hexagon Implants with One-Piece Zirconia Crowns
This study aimed to evaluate the survival rates of several external hexagon implants directly connected to zirconia crowns after thermomechanical fatigue. The deformation of the hexagons and the integrity of zirconia crowns were also evaluated. A monolithic zirconia crown (Y-TZP) and four different external hexagon dental implants (n = 10, N = 40) were mounted together and embedded in polyurethane. The specimens were subjected to thermomechanical cycling for 2.5 × 106 cycles, at 3.0 Hz frequency, at 200 N loading. The interface of the implant/zirconia crown system, zirconia crowns integrity before and after cycling, and the implant hexagon surface were evaluated under stereomicroscopy and SEM. A nanohardness analysis was performed to verify the hardness of zirconia and implants. Statistical analysis was performed using the Kaplan-Meier test, Multi-Sample Survival Tests, Logrank Test, (p = 0.05). The data did not show significant differences in the survival rates of different implant groups. However, some crowns presented fractures (16.67%) and the external hexagon region of the implants presented plastic deformations (100%). During chewing simulation, the interface between titanium implant and zirconia abutment can promote plastic deformation in the metal and surface defects in the ceramic. In addition, the types of interface defects can be affected by the external hexagon design.
Open AccessSurvival Rate and Deformation of External Hexagon Implants with One-Piece Zirconia Crowns
This study aimed to evaluate the survival rates of several external hexagon implants directly connected to zirconia crowns after thermomechanical fatigue. The deformation of the hexagons and the integrity of zirconia crowns were also evaluated. A monolithic zirconia crown (Y-TZP) and four different external hexagon dental implants (n = 10, N = 40) were mounted together and embedded in polyurethane. The specimens were subjected to thermomechanical cycling for 2.5 × 106 cycles, at 3.0 Hz frequency, at 200 N loading. The interface of the implant/zirconia crown system, zirconia crowns integrity before and after cycling, and the implant hexagon surface were evaluated under stereomicroscopy and SEM. A nanohardness analysis was performed to verify the hardness of zirconia and implants. Statistical analysis was performed using the Kaplan-Meier test, Multi-Sample Survival Tests, Logrank Test, (p = 0.05). The data did not show significant differences in the survival rates of different implant groups. However, some crowns presented fractures (16.67%) and the external hexagon region of the implants presented plastic deformations (100%). During chewing simulation, the interface between titanium implant and zirconia abutment can promote plastic deformation in the metal and surface defects in the ceramic. In addition, the types of interface defects can be affected by the external hexagon design.