Juan José González-España
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Juan José González-España has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gerard E. Francisco
Department of Physical Medicine and Rehabilitation, The University of Texas Health Science Center at Houston, Houston, Texas
3 shared publications - Jose Luis Contreras-Vidal
University of Houston
3 shared publications - Lianne Sanchez Rodriguez
Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77004, USA
3 shared publications - Alexander Craik
Electrical Engineering, University of Houston, N308 Engineering Bldg 1, 4726 Calhoun Rd, Houston, Texas, 77204, UNITED STATES
2 shared publications - Ayman Alamir
Noninvasive Brain-Machine Interface Systems Laboratory, NSF Industry—University Cooperative Research Center for Building Reliable Advances and Innovations in Neurotechnology (IUCRC BRAIN) Center, University of Houston, Houston, TX 77004, USA
2 shared publications - David Edquilang
Department of Industrial Design, University of Houston, Houston, TX 77004, USA
2 shared publications
Latest Publications
- Open Access
At-Home Stroke Neurorehabilitation: Early Findings with the NeuroExo BCI System
Background: Democratized access to safe and effective robotic neurorehabilitation for stroke survivors requires innovative, affordable solutions that can be used not only in clinics but also at home. This requires the high usability of the devices involved to minimize costs associated with support from physical therapists or technicians. Methods: This paper describes the early findings of the NeuroExo brain–machine interface (BMI) with an upper-limb robotic exoskeleton for stroke neurorehabilitation. This early feasibility study consisted of a six-week protocol, with an initial training and BMI calibration phase at the clinic followed by 60 sessions of neuromotor therapy at the homes of the participants. Pre- and post-assessments were used to assess users’ compliance and system performance. Results: Participants achieved a compliance rate between and , with an average of , while maintaining adequate signal quality and a positive perceived BMI performance during home usage with an average Likert scale score of four out of five. Moreover, adequate signal quality was maintained for four out of five participants throughout the protocol. These findings provide valuable insights into essential components for comprehensive rehabilitation therapy for stroke survivors. Furthermore, linear mixed-effects statistical models showed a significant reduction in trial duration (p-value < 0.02) and concomitant changes in brain patterns (p-value < 0.02). Conclusions: the analysis of these findings suggests that a low-cost, safe, simple-to-use BMI system for at-home stroke rehabilitation is feasible.Open AccessAt-Home Stroke Neurorehabilitation: Early Findings with the NeuroExo BCI System
Background: Democratized access to safe and effective robotic neurorehabilitation for stroke survivors requires innovative, affordable solutions that can be used not only in clinics but also at home. This requires the high usability of the devices involved to minimize costs associated with support from physical therapists or technicians. Methods: This paper describes the early findings of the NeuroExo brain–machine interface (BMI) with an upper-limb robotic exoskeleton for stroke neurorehabilitation. This early feasibility study consisted of a six-week protocol, with an initial training and BMI calibration phase at the clinic followed by 60 sessions of neuromotor therapy at the homes of the participants. Pre- and post-assessments were used to assess users’ compliance and system performance. Results: Participants achieved a compliance rate between and , with an average of , while maintaining adequate signal quality and a positive perceived BMI performance during home usage with an average Likert scale score of four out of five. Moreover, adequate signal quality was maintained for four out of five participants throughout the protocol. These findings provide valuable insights into essential components for comprehensive rehabilitation therapy for stroke survivors. Furthermore, linear mixed-effects statistical models showed a significant reduction in trial duration (p-value < 0.02) and concomitant changes in brain patterns (p-value < 0.02). Conclusions: the analysis of these findings suggests that a low-cost, safe, simple-to-use BMI system for at-home stroke rehabilitation is feasible. - Open Access
Design and Validation of a Low-Cost Mobile EEG-Based Brain–Computer Interface
Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain–computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user’s hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal–to–noise ratio (SNR) and common–mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device’s use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.
Open AccessDesign and Validation of a Low-Cost Mobile EEG-Based Brain–Computer Interface
Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain–computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user’s hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal–to–noise ratio (SNR) and common–mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device’s use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.
- Open Access
- 15 May 2023
- Published by MDPI AG in Preprints.org
Design and validation of a low-cost mobile EEG-based Brain-Computer Interface
Objective: Design and validate a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90\% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An accelerometer provides monitoring of head movements. The EEG amplifier operates with 24 bits resolution up to 500 Hz sampling frequency, and can communicate with other devices using 802.11 {b/g/n/WiFi}. It has high SNR and CMRR (121 dB and 110 dB, respectively), and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as backend coding language and JS, CSS, HTML as front-end coding languages, and includes training and optimization of Support Vector Machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation provides proof-of-concept validation for device use at both the clinic and at home. Significance: The low-cost, accessibility, usability, interoperability, and programmability of the proposed closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.
- 15 May 2023
- Published by MDPI AG in Preprints.org
Open AccessDesign and validation of a low-cost mobile EEG-based Brain-Computer Interface
Objective: Design and validate a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90\% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An accelerometer provides monitoring of head movements. The EEG amplifier operates with 24 bits resolution up to 500 Hz sampling frequency, and can communicate with other devices using 802.11 {b/g/n/WiFi}. It has high SNR and CMRR (121 dB and 110 dB, respectively), and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as backend coding language and JS, CSS, HTML as front-end coding languages, and includes training and optimization of Support Vector Machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation provides proof-of-concept validation for device use at both the clinic and at home. Significance: The low-cost, accessibility, usability, interoperability, and programmability of the proposed closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21562318,p. 1850-1856
Peniel method for the automation of the ultrasonic monitoring based on the acoustic impedance
The industrial processes continuously require of better technologies which let to improve the effectiveness, efficiency and quality of their actions. One method to achieve this is based on the monitoring of the obtained sample or the industrial process itself. In this article is addressed the monitoring and the inspection of industrial products and processes through ultrasonic systems which analyze the behavior of the acoustic impedance. Some of the more important applications are in sectors such as energy, chemicals, aerospace, automobile, food, construction, among others. Although, the wide potential of this technique has been limited by the computational requirements of the algorithms associated with it, requiring of significant computing systems or devices, which is an obstacle for their implementation in small sensor systems. In this work is illustrated a novel signal processing method called Peniel, which has low computing requirements and has a significant circuital simplicity. This method was successfully implemented in a microcontroller of low computational capabilities.
- 1 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21562318,p. 1850-1856
Peniel method for the automation of the ultrasonic monitoring based on the acoustic impedance
The industrial processes continuously require of better technologies which let to improve the effectiveness, efficiency and quality of their actions. One method to achieve this is based on the monitoring of the obtained sample or the industrial process itself. In this article is addressed the monitoring and the inspection of industrial products and processes through ultrasonic systems which analyze the behavior of the acoustic impedance. Some of the more important applications are in sectors such as energy, chemicals, aerospace, automobile, food, construction, among others. Although, the wide potential of this technique has been limited by the computational requirements of the algorithms associated with it, requiring of significant computing systems or devices, which is an obstacle for their implementation in small sensor systems. In this work is illustrated a novel signal processing method called Peniel, which has low computing requirements and has a significant circuital simplicity. This method was successfully implemented in a microcontroller of low computational capabilities.