SCSean C. Chapman

Sean C. Chapman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sean C. Chapman has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spectroscopic ellipsometry of SU‐8 photoresist from 190 to 1680 nm (0.740–6.50 eV)

    by George H. Major, Sean C. Chapman, Jeffrey T. Chapman, Joshua I. Wheeler, Shiladitya Chatterjee, Cody V. Cushman, Daniel H. Ess, Matthew R. Linford

    SU‐8 is an important, epoxy‐based, negative photoresist that can create high aspect ratio features. Spectroscopic ellipsometry (SE) is a nondestructive analytical technique that can be performed in the open air. In this study, reflection and transmission SE measurement data were combined to model the optical function of SU‐8 photoresist. The data were fit using three different models: (i) a B‐spline model, (ii) a four‐Gaussian oscillator model with an ultraviolet (UV) and an infrared (IR) pole, and (iii) a Cody–Lorentz model with three additional Gaussian oscillators. All three models successfully fit the data, where the B‐spline model showed the lowest mean squared error. In situ SE data were also collected and fitted to follow possible changes in the optical properties of the SU‐8 during its development. Time‐dependent density functional theory (TD‐DFT) modeling of a complete SU‐8 monomer is qualitatively and quantitatively consistent with the measured optical function.


  • Direct Dielectric Barrier Discharge Ionization Promotes Rapid and Simple Lubricant Oil Fingerprinting

    by Tatiana de Oliveira Zuppa Neto, Tahereh Gholian Avval, Pedro Augusto Oliveira Morais, Wade C. Ellis, Sean C. Chapman, Anselmo Elcana de Oliveira, Matthew R. Linford, Paul B. Farnsworth, Nelson Roberto Antoniosi Filho

    Petroleomics, which is the characterization, separation and quantification of the components of petroleum and crude oil, is an emerging area of study. However, the repertoire of analytical methods available to understand commercial automotive lubricant oils (ALOs) is very limited. Ambient mass spectrometry is one of the most sensitive analytical methods for real-time and in situ chemical analysis. With this technique, the chemical fingerprinting of ALOs can be performed quickly and simply using dielectric barrier discharge ionization time-of-flight mass spectrometry (DBDI-TOFMS). The mass spectra of thirty-five samples were obtained without any sample preparation or extraction in positive ion mode, and no carryover was observed. To elucidate the similarities and differences between the ALO samples, the data generated from these spectra were analyzed using four chemometric techniques: principal component analysis (PCA), multivariate curve resolution (MCR), hierarchical cluster analysis (HCA), and Pattern Recognition Entropy (PRE). The ALO samples were readily differentiated according to their American Petroleum Institute (API) classification and base oil types: mineral, semi-synthetic, and synthetic. The development of this new methodology will aid in the semi-quantitative control analysis of ALOs and offers an improved ability to identify the components therein.


  • Clinoptilolite, a type of zeolite, by near ambient pressure-XPS

    by Tahereh G. Avval, Victoria Carver, Sean C. Chapman, Stephan Bahr, Paul Dietrich, Michael Meyer, Andreas Thißen, Matthew R. Linford

    Near ambient pressure-x-ray photoelectron spectroscopy (NAP-XPS) is a less traditional form of XPS that allows samples to be analyzed at relatively high pressures, i.e., at greater than 2500 Pa. With NAP-XPS, XPS can probe moderately volatile liquids, biological samples, porous materials, and/or polymeric materials that outgas significantly. In this paper, we show the NAP-XPS survey; O 1s, Ca 2p, C 1s, K 2p, Al 2s, Al 2p, Si 2p, and Si 2s narrow scans; and the extended valence band spectrum of clinoptilolite, a natural zeolite that would be difficult to analyze by conventional XPS. A small N 1s signal from N2(g) is also observed in the survey spectrum. Signals in the narrow scans are fit to Gaussian–Lorentzian sum and Gaussian–Lorentzian product functions.


  • Informatics analysis of capillary electropherograms of autologously doped and undoped blood

    by Shiladitya Chatterjee, Sean C. Chapman, George H. Major, Denis L. Eggett, Barry M. Lunt, Christopher R. Harrison, Matthew R. Linford

    An ‘Autologous Blood Transfusion’ (ABT) is the reinjection of blood previously taken from an athlete to increase its oxygen transport capabilities. Despite the World Anti-Doping Agency's ban on such practices, ABT abuse continues. Autologous blood doping (ABD) is challenging to detect because of the similarities between an individual's doped and undoped blood. Recently, Harrison et al. reported that high-speed capillary electrophoresis may identify ABD. In their work, first order derivatives of the electropherograms were used to identify doping. However, this method suffered from false negatives due to the subjective nature of the analysis. Here, we provide an informatics analysis of the data from this study, contrasting the results of traditional statistical methods and less traditional mathematical techniques. First, three well-known multivariate statistical tools: cluster analysis, principal component analysis (PCA), and partial least squares (PLS) are applied to develop calibrations and/or group electropherograms of undoped (0%) and doped (5% and 10%) blood samples. (These doping levels were chosen due to the low physiological effect of doping below 5%, with 10% corresponding to the approximate ‘gain’ derived from the transfusion of a single unit of blood into an adult.) Different preprocessing and variable selection methods were considered. Due to variation in the electropherograms and the limited sample size, these methods were inadequate. We next considered four less commonly used mathematical/informatics tools: pattern recognition entropy (PRE), the Euclidean distance between vectors, a peak fitting/integration method, and the second moment (SM). Each of these techniques showed some ability to differentiate between the 0, 5, and 10% doped samples. We then evaluated the prediction capabilities of inverse least squares (ILS) models based on these summary statistics. An ILS calibration based on PRE, the Euclidean distance, and peak fitting/integration proved more successful than the PLS model at predicting levels of blood doping from the corresponding electropherograms; the ILS model distinguished between doped (5% and 10%) and undoped (0%) blood. This methodology may be applicable to other challenging informatics problems like determining risk factors for genetically linked diseases, robust pattern finding in peak-like data such as ChIP-seq, or other genomic sequencing for understanding the 3D genome.


  • Using Cross-Correlation with Pattern Recognition Entropy to Obtain Reduced Total Ion Current Chromatograms from Raw Liquid Chromatography-Mass Spectrometry Data

    by Shiladitya Chatterjee, Sean C. Chapman, Barry M. Lunt, Matthew R. Linford

    Total ion current chromatograms (TICCs) generated by liquid chromatography-mass spectrometry (LC-MS) are prone to noise from chemical and electronic sources. This noise can severely impact the detection of analytes in a mixture. Recently, we introduced a new variable selection tool based on Pattern Recognition Entropy (PRE) that selects good quality (high signal-to-noise ratio) mass chromatograms from an LC-MS dataset and thereby creates a reduced TICC with low noise and a flat background (J. Chrom. A. 2018, 1558, 21-28). PRE, which is based on Shannon's entropy, was shown to be a straightforward and powerful shape recognition tool for this problem. However, while the chromatographic signals in the reduced TICC from PRE were well resolved, some noise remained in the TICC, which suggested that the algorithm had selected some false positives, i.e., poor quality mass chromatograms. In this paper, we report an improved version of the PRE algorithm that utilizes a second variable selection filter based on cross-correlation (CC). As a check on the ability of PRE and CC to select high quality mass chromatograms, every mass chromatogram in our data set (1451 in total) was individually inspected and rated as either high quality (green), intermediate quality (yellow), or poor quality (red). A color-coded plot of the CC value vs. the PRE value for the mass chromatograms was created, which shows that, as expected, the higher quality mass chromatograms are localized in its upper left quadrant, which corresponds to lower PRE values and higher CC values. In our original paper on this topic, we recommended a threshold of 0.5 sigma for PRE, which caused the algorithm to select 151 mass chromatograms out of 1451. Of these, 98 were of high quality, 6 were of intermediate quality, and 47 were of poor quality. Using a second threshold for CC, the algorithm retains all the high and intermediate quality mass chromatograms, while removing all 47 of the poor quality ones. The resulting TICC from the PRE-CC algorithm shows less noise compared to the TICC generated from the PRE approach alone. The PRE-CC algorithm is arguably a faster, simpler and more intuitive approach as compared to the widely used CODA_DW algorithm.