Yalin Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yalin Lu has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Zhang Lin
City University of Hong Kong
7 shared publications - Nan Ma
Department of Civil, Environmental, & Architectural Engineering, Worcester Polytechnic Institute, Worcester, MA, United States
3 shared publications Zhang Lin
3 shared publicationsDun Niu
2 shared publications- Ignacio E. Tapia
Division of Pediatric Pulmonology, University of Miami Miller School of Medicine, Miami, FL
2 shared publications Jian Liu
2 shared publications
Latest Publications
- Open Access
- 25 May 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 147
Housing conditions as drivers of pediatric sleep disparities in U.S. cities
- 25 May 2026
- Published by Elsevier in Sustainable Cities and Society
- Vol. 147
Open AccessHousing conditions as drivers of pediatric sleep disparities in U.S. cities
- Open Access
- 2 May 2026
- Published by Elsevier in Energy and Buildings
- Vol. 363
Energy responsive ventilation control strategies to improve sleep health for wildfire smoke resilience
- 2 May 2026
- Published by Elsevier in Energy and Buildings
- Vol. 363
Open AccessEnergy responsive ventilation control strategies to improve sleep health for wildfire smoke resilience
- Open Access
- 14 January 2025
- Published by Elsevier in Environmental Research
- Vol. 269, 120860
Towards healthy sleep environments: Ambient, indoor, and personal exposure to PM2.5 and its implications in children's sleep health
- 14 January 2025
- Published by Elsevier in Environmental Research
- Vol. 269, 120860
Open AccessTowards healthy sleep environments: Ambient, indoor, and personal exposure to PM2.5 and its implications in children's sleep health
- 11 April 2023
- Published by Elsevier in Building and Environment
- Vol. 236
Impact of different supply modes of stratum ventilation on airflow and contaminant distribution characteristics
- 11 April 2023
- Published by Elsevier in Building and Environment
- Vol. 236
Impact of different supply modes of stratum ventilation on airflow and contaminant distribution characteristics
- 5 September 2022
- Published by Elsevier in Building and Environment
- Vol. 224
Stratified micro-environments using a sidewall air supply: An experimental and simulation study
- 5 September 2022
- Published by Elsevier in Building and Environment
- Vol. 224
Stratified micro-environments using a sidewall air supply: An experimental and simulation study
- 15 July 2022
- Published by Elsevier in Energy and Buildings
- Vol. 271
Stratum-air-distributed radiant-convective room air conditioner for heating
- 15 July 2022
- Published by Elsevier in Energy and Buildings
- Vol. 271
Stratum-air-distributed radiant-convective room air conditioner for heating
- 13 June 2022
- Published by Wiley in Indoor Air
- Vol. 32 (6) , e13061
Zonal model for predicting contaminant distribution in stratum ventilated rooms
Accurate prediction of the non-uniform contaminant distribution under stratum ventilation (SV) is crucial for optimal design for reducing contaminant exposure risks. Compared with experiments and computational fluid dynamics, zonal models are convenient to implement. This study proposes a zonal model for predicting dynamic non-uniform contaminant distribution in the stratum ventilated room. The zoning method is based on the unique airflow pattern under SV, and the room is divided into the jet zone, entrainment zone, and the mixing zone. The interzonal airflow rate is derived from the profile of the supply air jet. The results show that the proposed zonal model can predict the dynamic contaminant distribution in the stratum ventilated room. Compared with the experimental measurement, the predictions show good accuracy with the mean absolute error (MAE) at 0.51-2.36 ppm and root mean squared error (RMSE) at 0.64-2.53 ppm. The error of the proposed zonal model is influenced by the degree of mixing in each subzone. The proposed zonal model shows better accuracy for non-uniform air distribution under stratum ventilation compared with the existing zonal model.
- 13 June 2022
- Published by Wiley in Indoor Air
- Vol. 32 (6) , e13061
Zonal model for predicting contaminant distribution in stratum ventilated rooms
Accurate prediction of the non-uniform contaminant distribution under stratum ventilation (SV) is crucial for optimal design for reducing contaminant exposure risks. Compared with experiments and computational fluid dynamics, zonal models are convenient to implement. This study proposes a zonal model for predicting dynamic non-uniform contaminant distribution in the stratum ventilated room. The zoning method is based on the unique airflow pattern under SV, and the room is divided into the jet zone, entrainment zone, and the mixing zone. The interzonal airflow rate is derived from the profile of the supply air jet. The results show that the proposed zonal model can predict the dynamic contaminant distribution in the stratum ventilated room. Compared with the experimental measurement, the predictions show good accuracy with the mean absolute error (MAE) at 0.51-2.36 ppm and root mean squared error (RMSE) at 0.64-2.53 ppm. The error of the proposed zonal model is influenced by the degree of mixing in each subzone. The proposed zonal model shows better accuracy for non-uniform air distribution under stratum ventilation compared with the existing zonal model.
- 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Coughed droplet dispersion pattern in hospital ward under stratum ventilation
- 1 January 2022
- Published by Elsevier in Building and Environment
- Vol. 208
Coughed droplet dispersion pattern in hospital ward under stratum ventilation