SYSiliang Yang

Siliang Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siliang Yang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysing Daylighting Sufficiency via Thermal Performance-Centred Glazed Fenestration in UK Residential Home-Office Environments

    by Ryan Gagg, Fraser Torpy, Biyanka Ekanayake, Sara Wilkinson, Shen Wei, Deo Prasad, Siliang Yang

    The COVID-19 pandemic has led to a rise in residential office utilisation. As a result, it has become increasingly important to configure workspaces and design dwellings to ensure adequate indoor environmental quality. Currently, UK industry best practice largely focuses on rationalising the window-to-wall ratio (WWR) for dwellings. However, there is an increased regulatory stringency on new build glazing thermal performance, without much regard to achieving adequate daylighting. This paper looks into enhancing daylighting sufficiency within newly constructed UK housing to meet the daylight availability requirements of the British Standard—BS EN 17037:2018+A1:2021—whilst simultaneously ensuring daylighting sufficiency, thermal comfort, and sustainability. A quantitative methodology was adopted using DesignBuilder through a calibrated daylighting simulation in association with thermal modelling for a typical semi-detached house in the UK. The performance of five glazing solutions with varying WWR was assessed against BS EN 17037:2018+A1:2021. The WWR of all glazing types was increased from an initial WWR of 15.26% until daylighting sufficiency was realised. The findings show that the house attained inadequate daylighting with the initial WWR of 15.26%, as 77% of frequently occupied spaces achieved an illuminance of 100 lx for 50% of the daylight hours and 300 lx for 42% of the frequently occupied space for 50% of the daylight hours, which failed to comply with the standard. Thus, a larger WWR of 25% is required for the house to comply with the current daylighting standard with the existing glazing type. However, a change of glazing type would enable compliance at a lower 20% WWR. In this study, a refinement strategy was conceived to review a combination of key parameters for refining the glazing selection. However, it was found that no compliant daylighting refinement strategy could be realised without an increase of 3.66 °C to the peak operative temperature. This paper, however, highlights the significance of fenestration selection beyond thermal performance, demonstrating the importance of other design variables such as daylight transmittance, solar heat gain coefficient, glazing heat losses, and peak operative temperatures.

  • Open Access

    Thermal and Optical Performance of Semi-Transparent BIPV Windows in High-Rise Office Buildings: A Case Study in the UK

    by Joseph Scibetta, Shaohang Shi, Hu Du, Bao-Jie He, Siliang Yang

    Semi-transparent building-integrated photovoltaic (BIPV) windows replace the external building glazing, allowing power to be generated as part of the existing building envelope. Due to the replacing of the BIPV windows, both thermal and optical performance of a building are worth exploring. This paper presents the results of a simulation study investigating the effects of applying BIPV windows to an existing office building within the UK, with a view to assessing the thermal performance, daylighting condition and BIPV electrical production capacity. It was considered on a typical floor of the office building, consisting of an open plan office space, two meeting rooms and a kitchen suite. A baseline scenario without BIPV window was modelled for comparison, giving recommendations to the viability of the BIPV window in terms of the overall performance. Basically, the use of the BIPV window resulted an annual cooling load reduction of 16.3% compared to the baseline. Heating loads were also reduced but only by 1.89%, while lighting energy usage was slightly increased due to a significantly worse performance in daylighting condition in the open plan office when applying the BIPV window. Specifically, daylight factor dropped over 50% in the office area, which, however, was already poor to begin with. The annual electricity generation of the BIPV window was little with only 902 kWh. This study can be a reference for future research on thermal and optical performance of high-rise office buildings using semi-transparent BIPV windows.


  • Open Access

    Energy and Daylighting Performance of Kinetic Building-Integrated Photovoltaics (BIPV) Façade

    by Sujan Dev Sureshkumar Jayakumari, Samarasinghalage Tharushi Imalka, Rebecca Jing Yang, Chengyang Liu, Siliang Yang, Max Marschall, Pablo Sepulveda Corradini, Adolfo Fernandez Benito, Nick Williams

    The deployment of renewable energy in the construction industry has emerged as a crucial topic due to the building sector’s substantial energy consumption and greenhouse gas emissions. Building Integrated Photovoltaics (BIPV) offers a promising solution, replacing conventional building materials with solar energy-generating components. Moreover, retrofitting commercial buildings with BIPV and kinetic façades present an innovative approach to improve energy efficiency and enhance occupant well-being. Adaptive façades, capable of responding to varying climatic conditions, play a pivotal role in reducing energy consumption while ensuring thermal and visual comfort for occupants. By integrating solar generation and shading capabilities, BIPV kinetic façades deliver dual benefits, optimizing energy performance and reducing lifecycle costs, compared to traditional PV systems. Furthermore, effective daylighting strategies not only contribute to energy savings but also positively impact occupant productivity and comfort. Despite predominant research focusing on energy aspects, there is a notable gap in comprehensive assessments that integrate environmental, economic, and daylighting considerations. Therefore, evaluating Australian commercial buildings’ energy and daylighting performance with BIPV kinetic façades provides valuable insights for advancing sustainable building designs and operations in the region. The implementation of kinetic BIPV façades in Melbourne reduced energy consumption by 18% and covered 26% of energy demand, achieving the target daylighting levels.


  • Open Access

    Investigating the Effects of PCM-Integrated Walls on Thermal Performance for UK Residential Buildings of Different Typologies

    by Ryan Hepple, Yusen Zhao, Rebecca Yang, Qian Zhang, Siliang Yang

    Phase change materials (PCMs) can improve the thermal performance of building facades. The integration position of a PCM in the facades is influenced by multiple factors including the material properties of the PCM, building types, and the internal and external conditions of a building. However, this has not been a focus within the UK dwelling stock, where many dwellings are not thermally protected. This paper, therefore, presents a numerical study with the aid of building simulation that comparatively analysed the thermal performance between four typical UK dwelling types (semi-detached house, terraced house, detached house, and apartment) situated in North East England. The PCM was implemented into the external wall of the dwellings with the positions altered to determine the most effective position. It was determined that the PCM positioned internally was the most effective for all the dwelling types. These results demonstrated that the PCM being implemented in the apartment, semi-detached, and terraced houses had only marginal heat loss reductions (by 8%, 14%, and 8%, respectively) in comparison with that of the detached house (by 30%). It was also found that the large external wall area of the detached house acted as significant thermal energy storage, which was capable of offsetting heat transmission and stabilising indoor thermal conditions. In summary, this paper contributes to the matters concerning the effect of PCMs on indoor thermal performance in dwellings of different typologies in the UK.


  • Open Access

    A Case Study of Existing Peer-to-Peer Energy Trading Platforms: Calling for Integrated Platform Features

    by Shan Shan, Siliang Yang, Victor Becerra, Jiamei Deng, Honglei Li

    The emergence of distributed energy has led to a change in the role of the consumer in the traditional sense over the past decade. The proliferation of emerging generators and distributors has created opportunities for a more decentralised and open energy market. In particular, the emergence of peer-to-peer (P2P) energy trading models, challenged by the surge in demand for sustainable energy, has eliminated the need for intermediaries in energy transactions between consumers, producers, and sellers. Due to the great promise of sustainable energy, both in terms of its contribution to the environment and production costs, this paper reviews a number of well-known P2P energy trading platforms to understand what makes P2P energy trading platforms more functional. As a result, areas for consideration were identified and grouped into five themes: (1) set-up, (2) market, (3) information, (4) price, and (5) regulation.


  • Open Access

    The Application of Human-Centric Lighting in Response to Working from Home Post-COVID-19

    by Frank Roberts, Michael White, Saim Memon, Bao-Jie He, Siliang Yang

    COVID-19 has caused a considerable proportion of the public to work from home, either part- or full-time, in unregulated domestic conditions, which have not been designed for commercial activities. This study determined what existing lighting conditions were present in a selection of work-from-home (WFH) environments (Objective One) through quantitative lux level and equivalent melanopic lux (EML) readings by evaluating them against regulatory standards, where further study is required to validate the results with a larger dataset. This study also investigated the social demand for human-centric lighting (HCL) installations within WFH environments (Objective Two) through qualitative questionnaires by considering key parameters: sustainability, practicality, and cost. The results of Objective One showed that compliance with general safety lighting requirements was achieved by 80% of the installations. The mean lux level recorded was 452.4 lux and 0.729 uniformity, which fell below commercial requirements defined for commonly performed WFH activities; 34.3% of recorded EML dropped below the regulatory requirements under daylight conditions. When isolated to artificial lighting, only 7.5% of the required EML was achieved. The results of Objective Two showed that generally participants did not feel that their WFH installations were unsuitably lit, however, 46.2% of participants identified noticeable headaches or eye strain when working from home. A total of 80% of participants highlighted that HCL task lighting would be preferable. It was also found that participants were willing to invest in circadian lighting for health, where 63.2% of them would not accept a reduction in efficiency of over 10% compared to non HCL. Wellbeing was found to be participants’ key preference for their lighting systems, followed by efficiency, home impact, and cost.


  • Open Access

    Assessing heat transfer characteristics of building envelope deployed BIPV and resultant building energy consumption in a tropical climate

    by Hamza Jhumka, Siliang Yang, Christopher Gorse, Sara Wilkinson, Rebecca Yang, Bao-Jie He, Deo Prasad, Francesco Fiorito


  • Open Access

    Optimising Design Parameters of a Building-Integrated Photovoltaic Double-Skin Facade in Different Climate Zones in Australia

    by Siliang Yang, Francesco Fiorito, Alistair Sproul, Deo Prasad

    Energy used in buildings is mainly attributed to provide the desired thermal comfort, which could result in an increase in carbon emission and, in turn, lead to further environmental degradation. A Building-Integrated Photovoltaic Double-Skin Façade (BIPV-DSF) is a promising way to maintain indoor thermal comfort, obtained with low environmental impact and energy consumption. The appropriate design of BIPV-DSFs can maximise indoor thermal comfort and energy efficiency for buildings. This paper presents optimal BIPV-DSF design solutions, which are dedicated to offering comfortable and energy-efficient buildings, through optimisation of the most important design parameters of a BIPV-DSF under three different climate conditions in Australia. The results illustrate how thermal transmittance (U-value) and solar heat gain coefficient (SHGC) of windows of the BIPV-DSF, as the most important design parameters, were optimised for application in the context of different climates, operation modes, and orientations. The paper contributes to the matters concerning the integrated effect of BIPV-DSFs on thermal comfort and energy performance in buildings.