Yu Wang
Research Subjects
Yu Wang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Jinling Yang
West China School of Public Health, Sichuan University, Chengdu 610041, China
4 shared publicationsYongxin Li
West China School of Public Health, Sichuan University, Chengdu 610041, China; Provincial Key Laboratory for Food Safety Monitoring and Risk Assessment of Sichuan, Chengdu 610041, China
4 shared publicationsChengjun Sun
3 shared publicationsJia Ruan
2 shared publicationsJing Zhang
2 shared publicationsQianru Zhou
Chongqing Center for Disease Control and Prevention, Chongqing, China; College of Public Health, Chongqing Medical University, Chongqing, China
2 shared publications
Latest Publications
- 28 April 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1308, 342662
For the occurrence of PPCPs from source to tap: A novel approach modified in terms of sample preservation and SPE cartridge to monitor PPCPs in our water supply
- 28 April 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1308, 342662
For the occurrence of PPCPs from source to tap: A novel approach modified in terms of sample preservation and SPE cartridge to monitor PPCPs in our water supply
- 27 January 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (3) , 219-231
Validation of the Sample Preservation and Analysis of Dimethyl Disulfide and Dimethyl Trisulfide in Tap Water and Source Water
- 27 January 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (3) , 219-231
Validation of the Sample Preservation and Analysis of Dimethyl Disulfide and Dimethyl Trisulfide in Tap Water and Source Water
- 1 March 2017
- Published by Elsevier in Food Control
- Vol. 73, 1134-1143
Gas chromatography-triple quadrupole tandem mass spectrometry for successive single-surface migration study of phthalate esters from polythene film
- 1 March 2017
- Published by Elsevier in Food Control
- Vol. 73, 1134-1143
Gas chromatography-triple quadrupole tandem mass spectrometry for successive single-surface migration study of phthalate esters from polythene film
- 1 April 2016
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 78, 1-16
Microbial volatile organic compounds and their application in microorganism identification in foodstuff
- 1 April 2016
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 78, 1-16
Microbial volatile organic compounds and their application in microorganism identification in foodstuff
- 1 October 2015
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 72, 10-26
Recent advances in analysis of phthalate esters in foods
- 1 October 2015
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 72, 10-26
Recent advances in analysis of phthalate esters in foods
- 23 January 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (7) , 2384-2389
Improved dispersive liquid–liquid microextraction based on the solidification of floating organic droplet method with a binary mixed solvent applied for determination of nicotine and cotinine in urine
A fast, simple and environmentally friendly method to determine nicotine and cotinine in urine has been developed using dispersive liquid–liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) with a binary mixed extractant as the pretreatment method and high performance liquid chromatography with an ultraviolet detector (HPLC-UVD) as the analysis system. The nicotine and cotinine in urine samples were extracted using the binary mixed solvent of undecanol and CHCl3 (v/v = 1 : 1) during the DLLME-SFO procedure. The employment of the mixed solvent had significantly improved the extraction efficiency of cotinine. Several crucial experiment parameters were evaluated, including the type and volume of extract solvent, type of dispersive solvent, pH of the aqueous phase, concentration of sodium chloride in the urine samples and extraction time. Under the optimal conditions, good linearity was observed in the range of 0.01–5.00 μg mL−1 for nicotine and cotinine with correlation coefficients of 0.9993 and 0.9996 respectively, and the method detection limit (MLD) was 0.002 μg mL−1 for both analytes. The proposed method was applied to urine sample analysis and the spiked recoveries of nicotine and cotinine were in the range of 78.0–105.0% and 72.0–86.7% respectively, with the relative standard deviations (RSDs) in the range of 6.02–7.28% and 2.94–8.43% respectively.
- 23 January 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (7) , 2384-2389
Improved dispersive liquid–liquid microextraction based on the solidification of floating organic droplet method with a binary mixed solvent applied for determination of nicotine and cotinine in urine
A fast, simple and environmentally friendly method to determine nicotine and cotinine in urine has been developed using dispersive liquid–liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) with a binary mixed extractant as the pretreatment method and high performance liquid chromatography with an ultraviolet detector (HPLC-UVD) as the analysis system. The nicotine and cotinine in urine samples were extracted using the binary mixed solvent of undecanol and CHCl3 (v/v = 1 : 1) during the DLLME-SFO procedure. The employment of the mixed solvent had significantly improved the extraction efficiency of cotinine. Several crucial experiment parameters were evaluated, including the type and volume of extract solvent, type of dispersive solvent, pH of the aqueous phase, concentration of sodium chloride in the urine samples and extraction time. Under the optimal conditions, good linearity was observed in the range of 0.01–5.00 μg mL−1 for nicotine and cotinine with correlation coefficients of 0.9993 and 0.9996 respectively, and the method detection limit (MLD) was 0.002 μg mL−1 for both analytes. The proposed method was applied to urine sample analysis and the spiked recoveries of nicotine and cotinine were in the range of 78.0–105.0% and 72.0–86.7% respectively, with the relative standard deviations (RSDs) in the range of 6.02–7.28% and 2.94–8.43% respectively.
- 1 January 2013
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 31 (11) , 1076
[Solvent demulsification-dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with gas chromatography-mass spectrometry for simultaneous determination of organochlorine pesticides in aqueous samples].
A novel method for simultaneous determination of eight organochlorine pesticides in solidification of floating organic drop coupled with gas chromatography-mass spectrometry (GC-MS) was established. A mixture of extractant (n-hexadecane) and dispersive agent (acetone) at the ratio of 1/5 (v/v) was injected into aqueous sample to form an emulsion and an extraction process was accomplished. The demulsifier (750 microL acetone) was then injected to break up the emulsion. The two phases were separated quickly without centrifugation. After being solidified in an ice-bath, the upper layer (n-hexadecane) was transferred into an Eppendorf tube and analyzed by GC-MS after melted at room temperature. Factors affecting extraction efficiency such as the type and volume of extractant, dispersive agent and demulsifier, also ionic strength and pH value of extraction system were studied. Under the optimized conditions, the working curve of the proposed method provided a good linearity in the range of 0.025-2.00 microg/L (r = 0.999 5-0.999 9). The detection limits of the organochlorine pesticides calculated by Hubaux-Vos method were 0.012-0.024 microg/L and the relative standard deviations (RSDs) ranged from 3.15% to 4.53%. The enrichment factors (EF) were 96-101. When the method was applied to the determination of farmland water, the average spiked recoveries were 96.77%-102.93% with the relative standard deviations of 2.68%-4.86%. The proposed method is sensitive and fast. It also has the advantage of little organic solvent consumption so that it is friendly to environment and suitable for batch analysis of organochlorine pesticides in aqueous samples. Meanwhile, it provides technical and methodological support for achieving the automation of sample pretreatment.
- 1 January 2013
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 31 (11) , 1076
[Solvent demulsification-dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with gas chromatography-mass spectrometry for simultaneous determination of organochlorine pesticides in aqueous samples].
A novel method for simultaneous determination of eight organochlorine pesticides in solidification of floating organic drop coupled with gas chromatography-mass spectrometry (GC-MS) was established. A mixture of extractant (n-hexadecane) and dispersive agent (acetone) at the ratio of 1/5 (v/v) was injected into aqueous sample to form an emulsion and an extraction process was accomplished. The demulsifier (750 microL acetone) was then injected to break up the emulsion. The two phases were separated quickly without centrifugation. After being solidified in an ice-bath, the upper layer (n-hexadecane) was transferred into an Eppendorf tube and analyzed by GC-MS after melted at room temperature. Factors affecting extraction efficiency such as the type and volume of extractant, dispersive agent and demulsifier, also ionic strength and pH value of extraction system were studied. Under the optimized conditions, the working curve of the proposed method provided a good linearity in the range of 0.025-2.00 microg/L (r = 0.999 5-0.999 9). The detection limits of the organochlorine pesticides calculated by Hubaux-Vos method were 0.012-0.024 microg/L and the relative standard deviations (RSDs) ranged from 3.15% to 4.53%. The enrichment factors (EF) were 96-101. When the method was applied to the determination of farmland water, the average spiked recoveries were 96.77%-102.93% with the relative standard deviations of 2.68%-4.86%. The proposed method is sensitive and fast. It also has the advantage of little organic solvent consumption so that it is friendly to environment and suitable for batch analysis of organochlorine pesticides in aqueous samples. Meanwhile, it provides technical and methodological support for achieving the automation of sample pretreatment.