Selja Vaalto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Selja Vaalto has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Jari Karhu
Satucon Oy
5 shared publications- Petro Julkunen
University of Eastern Finland
5 shared publications - Karita S.-T. Salo
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
4 shared publications Mervi Könönen
Department of Clinical Neurophysiology, Kuopio University hospital, Kuopio, Finland; Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
4 shared publications- Pantelis Lioumis
Aalto University
4 shared publications - Risto Juhani Ilmoniemi
Aalto University
4 shared publications
Latest Publications
- Open Access
Matching Corticospinal and Cortical Excitability along the motor cortex: TMS-EMG-EEG study
There is still no consensus on how to choose intensities for transcranial magnetic stimulation (TMS). The resting motor threshold (RMT)—the intensity needed to evoke muscle contractions in the contralateral limb muscles—is a robust muscle-specific index of corticospinal excitability. RMT from one of the hand muscles is commonly used as a reference for TMS neuromodulation interventions and TMS-electroencephalography (TMS-EEG) studies. However, it only provides an indirect measure of cortical excitability, and even for the primary motor cortex (M1), we do not understand how cortical and corticospinal excitability correspond to each other. Indeed, it remains unclear whether cortical responses to TMS follow similar location-dependent patterns along the M1 as RMTs, and whether subthreshold stimulation can reliably engage cortical circuits relevant to motor output. Combining TMS with electromyography (EMG) and EEG—TMS-EMG-EEG—enables simultaneous assessment of corticospinal and cortical excitability to answer these questions. We investigated how cortical excitability thresholds (CETs, measured with EEG), relate to corticospinal excitability thresholds (RMTs, measured with EMG) at the hand, arm, and leg hotspots along the M1 in 24 healthy subjects. RMTs and CETs were strongly correlated, and both increased from hand to arm to leg. CETs were generally lower than RMTs, indicating that subthreshold stimulation was enough to evoke robust early TMS evoked potentials (TEPs). Within subjects, CETs differed from the corresponding RMTs at all three M1 hotspots, and this difference increased from hand to leg representations. The findings of the present study argue against using a default hand-muscle RMT to set cortical excitability dosage along the M1 and beyond. Online TMS–EEG can enable real-time dosing and could improve stimulation precision, efficiency, and generalizability, but the site-specific variability calls for adaptive control. Dictionary: TMS-EMG-EEG: A multimodal neurophysiological approach, combining EMG and EEG recording during TMS, to assess corticospinal and cortical excitability simultaneously. Corticospinal Excitability: Responsiveness of the corticospinal motor pathway to stimulation, reflecting the combined excitability of cortical and spinal motor circuits. Cortical Excitability: Responsiveness of cortical neuronal circuits to external stimulation, including electrical and magnetic stimulation. EMG-EEG Compound Hotspot: The stimulation site that elicited clear and consistent early TEPs and reliable MEPs for the target muscle. MEP (motor evoked potential): Electrical activity recorded from the peripheral muscle via EMG, in response to TMS stimuli. RMT (resting motor threshold): A measure of corticospinal excitability. TEP (TMS-evoked potential): Electrical potentials recorded from the scalp via EEG, in response to TMS stimuli. CET (cortical excitability threshold): The early peak-to-peak deflection at an electrode near the stimulation site, quantified in real-time.
Open AccessMatching Corticospinal and Cortical Excitability along the motor cortex: TMS-EMG-EEG study
There is still no consensus on how to choose intensities for transcranial magnetic stimulation (TMS). The resting motor threshold (RMT)—the intensity needed to evoke muscle contractions in the contralateral limb muscles—is a robust muscle-specific index of corticospinal excitability. RMT from one of the hand muscles is commonly used as a reference for TMS neuromodulation interventions and TMS-electroencephalography (TMS-EEG) studies. However, it only provides an indirect measure of cortical excitability, and even for the primary motor cortex (M1), we do not understand how cortical and corticospinal excitability correspond to each other. Indeed, it remains unclear whether cortical responses to TMS follow similar location-dependent patterns along the M1 as RMTs, and whether subthreshold stimulation can reliably engage cortical circuits relevant to motor output. Combining TMS with electromyography (EMG) and EEG—TMS-EMG-EEG—enables simultaneous assessment of corticospinal and cortical excitability to answer these questions. We investigated how cortical excitability thresholds (CETs, measured with EEG), relate to corticospinal excitability thresholds (RMTs, measured with EMG) at the hand, arm, and leg hotspots along the M1 in 24 healthy subjects. RMTs and CETs were strongly correlated, and both increased from hand to arm to leg. CETs were generally lower than RMTs, indicating that subthreshold stimulation was enough to evoke robust early TMS evoked potentials (TEPs). Within subjects, CETs differed from the corresponding RMTs at all three M1 hotspots, and this difference increased from hand to leg representations. The findings of the present study argue against using a default hand-muscle RMT to set cortical excitability dosage along the M1 and beyond. Online TMS–EEG can enable real-time dosing and could improve stimulation precision, efficiency, and generalizability, but the site-specific variability calls for adaptive control. Dictionary: TMS-EMG-EEG: A multimodal neurophysiological approach, combining EMG and EEG recording during TMS, to assess corticospinal and cortical excitability simultaneously. Corticospinal Excitability: Responsiveness of the corticospinal motor pathway to stimulation, reflecting the combined excitability of cortical and spinal motor circuits. Cortical Excitability: Responsiveness of cortical neuronal circuits to external stimulation, including electrical and magnetic stimulation. EMG-EEG Compound Hotspot: The stimulation site that elicited clear and consistent early TEPs and reliable MEPs for the target muscle. MEP (motor evoked potential): Electrical activity recorded from the peripheral muscle via EMG, in response to TMS stimuli. RMT (resting motor threshold): A measure of corticospinal excitability. TEP (TMS-evoked potential): Electrical potentials recorded from the scalp via EEG, in response to TMS stimuli. CET (cortical excitability threshold): The early peak-to-peak deflection at an electrode near the stimulation site, quantified in real-time.
- Open Access
MEG-informed navigated TMS for individualized speech cortical mapping
Speech cortical mapping by means of navigated repetitive transcranial magnetic stimulation (SCM nrTMS) provides neurosurgeons with noninvasive prior information about individual’s cortical speech network. Individualized mapping is required, since the exact locations and activation patterns of speech production show high variability between individuals. We hypothesized that magnetoencephalography (MEG) data of an individual’s speech production could guide the SCM TMS process temporally and spatially, leading to higher error rates at MEG-defined locations with TMS pulse timings coinciding with MEG activity. 13 healthy subjects participated in MEG and TMS measurements, where the timing of the TMS pulse (PTI; picture-to-TMS interval) was adjusted based on the individual’s MEG activation in a picture naming task. At the group level, significant correlations were observed between the latency of the peak MEG activation and the PTI that produced the highest speech error rate. The MEG peak preceded the best PTI by 132 ms (R=0.713, p =0.006) across the entire stimulation area in the lateral left hemisphere, and by 103 ms (R=0.673, p =0.012) in the left frontal regions. We found 17 combinations of PTI and stimulation area in which the subject’s speech error rate increased significantly compared to their average error rate. Our findings suggest that optimal PTIs are highly individual, and that individualizing the PTI according to MEG activation provides a straightforward method for accounting individual variability in speech function and may increase the sensitivity and utility of SCM TMS.
Open AccessMEG-informed navigated TMS for individualized speech cortical mapping
Speech cortical mapping by means of navigated repetitive transcranial magnetic stimulation (SCM nrTMS) provides neurosurgeons with noninvasive prior information about individual’s cortical speech network. Individualized mapping is required, since the exact locations and activation patterns of speech production show high variability between individuals. We hypothesized that magnetoencephalography (MEG) data of an individual’s speech production could guide the SCM TMS process temporally and spatially, leading to higher error rates at MEG-defined locations with TMS pulse timings coinciding with MEG activity. 13 healthy subjects participated in MEG and TMS measurements, where the timing of the TMS pulse (PTI; picture-to-TMS interval) was adjusted based on the individual’s MEG activation in a picture naming task. At the group level, significant correlations were observed between the latency of the peak MEG activation and the PTI that produced the highest speech error rate. The MEG peak preceded the best PTI by 132 ms (R=0.713, p =0.006) across the entire stimulation area in the lateral left hemisphere, and by 103 ms (R=0.673, p =0.012) in the left frontal regions. We found 17 combinations of PTI and stimulation area in which the subject’s speech error rate increased significantly compared to their average error rate. Our findings suggest that optimal PTIs are highly individual, and that individualizing the PTI according to MEG activation provides a straightforward method for accounting individual variability in speech function and may increase the sensitivity and utility of SCM TMS.
- Open Access
fMRI analysis parameters affect the concordance with TMS in noninvasive speech mapping
Background: Speech cortical mapping (SCM) conducted with widely available functional MRI (fMRI) can yield divergent results compared to the more commonly used navigated TMS (nTMS). The impact of specific fMRI task paradigms and preprocessing choices on reaching similarity with nTMS has not been explored before. Objective: To test how the fMRI experimental task and spatial smoothing of the data compare with nTMS-based results, to subsequently increase the reliability of object naming fMRI for SCM. Methods: Thirteen healthy, right-handed Finnish speakers underwent an nTMS-based SCM experiment in which the left hemisphere was stimulated while the subjects overtly named common visually presented stimuli. Standard as well as magnetoencephalography-informed picture-to-TMS intervals were applied. The same participants completed fMRI with overt naming, silent naming, and observation tasks on the same stimuli, analyzed with 0-, 3-, and 6-mm spatial smoothing. nTMS-based error and non-error sites were converted to volumetric density maps, and error-specific maps were derived by subtracting non-error from error density. Spatial similarity between binarized fMRI maps and nTMS maps was quantified using Jaccard index. Within-session fMRI reliability was estimated with voxel- and subjectwise concordance correlation coefficients across two separate runs conducted on the same day. Results: Similarity between fMRI and nTMS maps was overall low but depended significantly on data smoothing. Within subjects, mean error-specific Jaccard index was 0.036, with most individuals showing maximal similarity at 6 mm of smoothing. The fMRI task resulting in highest similarity with the nTMS map varied across participants, but at the group level, silent naming with 6-mm smoothing yielded the best correspondence. In general, within-session fMRI reliability increased with greater smoothing. Conclusion: The amount of applied fMRI data smoothing shapes the agreement of fMRI and nTMS maps during SCM. Silent naming fMRI combined with 6-mm data smoothing yielded the highest overlap with nTMS maps, yet the effect of the experimental task was statistically non-significant and the absolute similarity of the maps remained low. These results underline the different views to brain functions provided by direct perturbation of neural functions vs. blood-oxygenation based fMRI, and offer practical guidance when combining fMRI with nTMS in noninvasive speech cortical mapping. Highlights: Correspondence of fMRI and TMS speech cortical mapping results varied across individuals Concordance between the methods was generally low and depended on the fMRI data smoothing Silent naming task in fMRI, combined with 6-mm data smoothing, yielded highest similarity to nTMS Within-session fMRI reliability increased with greater smoothing
Open AccessfMRI analysis parameters affect the concordance with TMS in noninvasive speech mapping
Background: Speech cortical mapping (SCM) conducted with widely available functional MRI (fMRI) can yield divergent results compared to the more commonly used navigated TMS (nTMS). The impact of specific fMRI task paradigms and preprocessing choices on reaching similarity with nTMS has not been explored before. Objective: To test how the fMRI experimental task and spatial smoothing of the data compare with nTMS-based results, to subsequently increase the reliability of object naming fMRI for SCM. Methods: Thirteen healthy, right-handed Finnish speakers underwent an nTMS-based SCM experiment in which the left hemisphere was stimulated while the subjects overtly named common visually presented stimuli. Standard as well as magnetoencephalography-informed picture-to-TMS intervals were applied. The same participants completed fMRI with overt naming, silent naming, and observation tasks on the same stimuli, analyzed with 0-, 3-, and 6-mm spatial smoothing. nTMS-based error and non-error sites were converted to volumetric density maps, and error-specific maps were derived by subtracting non-error from error density. Spatial similarity between binarized fMRI maps and nTMS maps was quantified using Jaccard index. Within-session fMRI reliability was estimated with voxel- and subjectwise concordance correlation coefficients across two separate runs conducted on the same day. Results: Similarity between fMRI and nTMS maps was overall low but depended significantly on data smoothing. Within subjects, mean error-specific Jaccard index was 0.036, with most individuals showing maximal similarity at 6 mm of smoothing. The fMRI task resulting in highest similarity with the nTMS map varied across participants, but at the group level, silent naming with 6-mm smoothing yielded the best correspondence. In general, within-session fMRI reliability increased with greater smoothing. Conclusion: The amount of applied fMRI data smoothing shapes the agreement of fMRI and nTMS maps during SCM. Silent naming fMRI combined with 6-mm data smoothing yielded the highest overlap with nTMS maps, yet the effect of the experimental task was statistically non-significant and the absolute similarity of the maps remained low. These results underline the different views to brain functions provided by direct perturbation of neural functions vs. blood-oxygenation based fMRI, and offer practical guidance when combining fMRI with nTMS in noninvasive speech cortical mapping. Highlights: Correspondence of fMRI and TMS speech cortical mapping results varied across individuals Concordance between the methods was generally low and depended on the fMRI data smoothing Silent naming task in fMRI, combined with 6-mm data smoothing, yielded highest similarity to nTMS Within-session fMRI reliability increased with greater smoothing
- Open Access
Repetition suppression of motor cortex may predict responsiveness to high-frequency rTMS in chronic pain
Background: High-frequency repetitive transcranial magnetic stimulation (rTMS) has been reported to yield promising, albeit variable, outcomes in chronic pain therapy and management. A factor contributing to the treatment success is individual neuroplastic capacity. Neuroplasticity can be assessed in various ways with TMS, e.g. through neural repetition suppression (RS) based on habituation. The present study aimed to evaluate the TMS-induced RS in patients with chronic pain, undergoing conventional rTMS treatment, and observing whether RS is indicative of the experienced analgesic effects. Methods: Twenty-one patients received standard 10-Hz rTMS treatment in five or ten daily sessions. Twenty RS trials, each consisting of four TMS pulses given 1 s apart, were given and assessed for motor evoked potentials (MEPs) before the first rTMS therapy session. For analysis purpose, the RS paradigm was evaluated through two states: 1) “ dynamic ” state (spontaneous excitability), first to second pulse, and 2) “ stable ” state (suppressed excitability), suppressed responses induced by second to fourth pulse. Analgesic effect from rTMS was assessed using Brief Pain Inventory (BPI), and painDETECT screening questionnaire, both conducted before and after the rTMS treatment. Results: Both the dynamic and the stable state RS exhibited good accuracy (0.789 – 0.944) in identifying patients showing analgesic effect in response to rTMS. Also, significantly greater suppression of MEPs ( p <0.05) were observed in the RS between those who benefitted from rTMS and those who did not. Conclusions: These indicative findings provide support for the potential of RS to set a premise for improved individualized neuromodulation treatments.
Open AccessRepetition suppression of motor cortex may predict responsiveness to high-frequency rTMS in chronic pain
Background: High-frequency repetitive transcranial magnetic stimulation (rTMS) has been reported to yield promising, albeit variable, outcomes in chronic pain therapy and management. A factor contributing to the treatment success is individual neuroplastic capacity. Neuroplasticity can be assessed in various ways with TMS, e.g. through neural repetition suppression (RS) based on habituation. The present study aimed to evaluate the TMS-induced RS in patients with chronic pain, undergoing conventional rTMS treatment, and observing whether RS is indicative of the experienced analgesic effects. Methods: Twenty-one patients received standard 10-Hz rTMS treatment in five or ten daily sessions. Twenty RS trials, each consisting of four TMS pulses given 1 s apart, were given and assessed for motor evoked potentials (MEPs) before the first rTMS therapy session. For analysis purpose, the RS paradigm was evaluated through two states: 1) “ dynamic ” state (spontaneous excitability), first to second pulse, and 2) “ stable ” state (suppressed excitability), suppressed responses induced by second to fourth pulse. Analgesic effect from rTMS was assessed using Brief Pain Inventory (BPI), and painDETECT screening questionnaire, both conducted before and after the rTMS treatment. Results: Both the dynamic and the stable state RS exhibited good accuracy (0.789 – 0.944) in identifying patients showing analgesic effect in response to rTMS. Also, significantly greater suppression of MEPs ( p <0.05) were observed in the RS between those who benefitted from rTMS and those who did not. Conclusions: These indicative findings provide support for the potential of RS to set a premise for improved individualized neuromodulation treatments.
- Open Access
- 19 June 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 185, 2110809
Increased motor cortex excitability in chronic complex regional pain syndrome
- 19 June 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 185, 2110809
Open AccessIncreased motor cortex excitability in chronic complex regional pain syndrome
- Open Access
- 1 December 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066037
Accuracy and precision of navigated transcranial magnetic stimulation
Objective. Transcranial magnetic stimulation (TMS) induces an electric field (E-field) in the cortex. To facilitate stimulation targeting, image-guided neuronavigation systems have been introduced. Such systems track the placement of the coil with respect to the head and visualize the estimated cortical stimulation location on an anatomical brain image in real time. The accuracy and precision of the neuronavigation is affected by multiple factors. Our aim was to analyze how different factors in TMS neuronavigation affect the accuracy and precision of the coil–head coregistration and the estimated E-field. Approach. By performing simulations, we estimated navigation errors due to distortions in magnetic resonance images (MRIs), head-to-MRI registration (landmark- and surface-based registrations), localization and movement of the head tracker, and localization of the coil tracker. We analyzed the effect of these errors on coil and head coregistration and on the induced E-field as determined with simplistic and realistic head models. Main results. Average total coregistration accuracies were in the range of 2.2–3.6 mm and 1°; precision values were about half of the accuracy values. The coregistration errors were mainly due to head-to-MRI registration with average accuracies 1.5–1.9 mm/0.2–0.4° and precisions 0.5–0.8 mm/0.1–0.2° better with surface-based registration. The other major source of error was the movement of the head tracker with average accuracy of 1.5 mm and precision of 1.1 mm. When assessed within an E-field method, the average accuracies of the peak E-field location, orientation, and magnitude ranged between 1.5 and 5.0 mm, 0.9 and 4.8°, and 4.4 and 8.5% across the E-field models studied. The largest errors were obtained with the landmark-based registration. When computing another accuracy measure with the most realistic E-field model as a reference, the accuracies tended to improve from about 10 mm/15°/25% to about 2 mm/2°/5% when increasing realism of the E-field model. Significance. The results of this comprehensive analysis help TMS operators to recognize the main sources of error in TMS navigation and that the coregistration errors and their effect in the E-field estimation depend on the methods applied. To ensure reliable TMS navigation, we recommend surface-based head-to-MRI registration and realistic models for E-field computations.
- 1 December 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066037
Open AccessAccuracy and precision of navigated transcranial magnetic stimulation
Objective. Transcranial magnetic stimulation (TMS) induces an electric field (E-field) in the cortex. To facilitate stimulation targeting, image-guided neuronavigation systems have been introduced. Such systems track the placement of the coil with respect to the head and visualize the estimated cortical stimulation location on an anatomical brain image in real time. The accuracy and precision of the neuronavigation is affected by multiple factors. Our aim was to analyze how different factors in TMS neuronavigation affect the accuracy and precision of the coil–head coregistration and the estimated E-field. Approach. By performing simulations, we estimated navigation errors due to distortions in magnetic resonance images (MRIs), head-to-MRI registration (landmark- and surface-based registrations), localization and movement of the head tracker, and localization of the coil tracker. We analyzed the effect of these errors on coil and head coregistration and on the induced E-field as determined with simplistic and realistic head models. Main results. Average total coregistration accuracies were in the range of 2.2–3.6 mm and 1°; precision values were about half of the accuracy values. The coregistration errors were mainly due to head-to-MRI registration with average accuracies 1.5–1.9 mm/0.2–0.4° and precisions 0.5–0.8 mm/0.1–0.2° better with surface-based registration. The other major source of error was the movement of the head tracker with average accuracy of 1.5 mm and precision of 1.1 mm. When assessed within an E-field method, the average accuracies of the peak E-field location, orientation, and magnitude ranged between 1.5 and 5.0 mm, 0.9 and 4.8°, and 4.4 and 8.5% across the E-field models studied. The largest errors were obtained with the landmark-based registration. When computing another accuracy measure with the most realistic E-field model as a reference, the accuracies tended to improve from about 10 mm/15°/25% to about 2 mm/2°/5% when increasing realism of the E-field model. Significance. The results of this comprehensive analysis help TMS operators to recognize the main sources of error in TMS navigation and that the coregistration errors and their effect in the E-field estimation depend on the methods applied. To ensure reliable TMS navigation, we recommend surface-based head-to-MRI registration and realistic models for E-field computations.
- 6 November 2019
- Published by Wolters Kluwer Health in NeuroReport
- Vol. 30 (16) , 1110-1114
Transcranial magnetic stimulation-evoked potentials after the stimulation of the right-hemispheric homologue of Broca’s area
The combination of transcranial magnetic stimulation and electroencephalography can be applied to probe effective connectivity. Neurons are excited by magnetic pulses, which produce transcranial magnetic stimulation-evoked potentials that can be monitored with electroencephalography. Effective connectivity refers to causal connections in the brain; it describes how different brain areas communicate with each other. Broca’s area is crucial for all phases of speech processing and is located in the frontotemporal region of the cortex. Only a few studies have investigated this region using transcranial magnetic stimulation–electroencephalography because of the large cranial muscles that are located over these areas, resulting in large artifacts covering the transcranial magnetic stimulation-evoked potentials. However, it is shown that this obstacle can be overcome with new artifact-removal tools. We used minimum-norm estimation to locate the sources of the neuronal signals in electroencephalography data after stimulating the right-hemispheric homologue of Broca’s area in three right-handed subjects; it was shown that the spreading of brain activity might be different for different individuals and that the brain activity spread fast to the contralateral hemisphere.
- 6 November 2019
- Published by Wolters Kluwer Health in NeuroReport
- Vol. 30 (16) , 1110-1114
Transcranial magnetic stimulation-evoked potentials after the stimulation of the right-hemispheric homologue of Broca’s area
The combination of transcranial magnetic stimulation and electroencephalography can be applied to probe effective connectivity. Neurons are excited by magnetic pulses, which produce transcranial magnetic stimulation-evoked potentials that can be monitored with electroencephalography. Effective connectivity refers to causal connections in the brain; it describes how different brain areas communicate with each other. Broca’s area is crucial for all phases of speech processing and is located in the frontotemporal region of the cortex. Only a few studies have investigated this region using transcranial magnetic stimulation–electroencephalography because of the large cranial muscles that are located over these areas, resulting in large artifacts covering the transcranial magnetic stimulation-evoked potentials. However, it is shown that this obstacle can be overcome with new artifact-removal tools. We used minimum-norm estimation to locate the sources of the neuronal signals in electroencephalography data after stimulating the right-hemispheric homologue of Broca’s area in three right-handed subjects; it was shown that the spreading of brain activity might be different for different individuals and that the brain activity spread fast to the contralateral hemisphere.
- Open Access
- 9 July 2019
- Published by Springer Nature in Brain Topography
- Vol. 33 (1) , 1-9
EEG Artifact Removal in TMS Studies of Cortical Speech Areas
The combination of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) is commonly applied for studying the effective connectivity of neuronal circuits. The stimulation excites neurons, and the resulting TMS-evoked potentials (TEPs) are recorded with EEG. A serious obstacle in this method is the generation of large muscle artifacts from scalp muscles, especially when frontolateral and temporoparietal, such as speech, areas are stimulated. Here, TMS–EEG data were processed with the signal-space projection and source-informed reconstruction (SSP–SIR) artifact-removal methods to suppress these artifacts. SSP–SIR suppressed muscle artifacts according to the difference in frequency contents of neuronal signals and muscle activity. The effectiveness of SSP–SIR in rejecting muscle artifacts and the degree of excessive attenuation of brain EEG signals were investigated by comparing the processed versions of the recorded TMS–EEG data with simulated data. The calculated individual lead-field matrix describing how the brain signals spread on the cortex were used as simulated data. We conclude that SSP–SIR was effective in suppressing artifacts also when frontolateral and temporoparietal cortical sites were stimulated, but it may have suppressed also the brain signals near the stimulation site. Effective connectivity originating from the speech-related areas may be studied even when speech areas are stimulated at least on the contralateral hemisphere where the signals were not suppressed that much.
- 9 July 2019
- Published by Springer Nature in Brain Topography
- Vol. 33 (1) , 1-9
Open AccessEEG Artifact Removal in TMS Studies of Cortical Speech Areas
The combination of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) is commonly applied for studying the effective connectivity of neuronal circuits. The stimulation excites neurons, and the resulting TMS-evoked potentials (TEPs) are recorded with EEG. A serious obstacle in this method is the generation of large muscle artifacts from scalp muscles, especially when frontolateral and temporoparietal, such as speech, areas are stimulated. Here, TMS–EEG data were processed with the signal-space projection and source-informed reconstruction (SSP–SIR) artifact-removal methods to suppress these artifacts. SSP–SIR suppressed muscle artifacts according to the difference in frequency contents of neuronal signals and muscle activity. The effectiveness of SSP–SIR in rejecting muscle artifacts and the degree of excessive attenuation of brain EEG signals were investigated by comparing the processed versions of the recorded TMS–EEG data with simulated data. The calculated individual lead-field matrix describing how the brain signals spread on the cortex were used as simulated data. We conclude that SSP–SIR was effective in suppressing artifacts also when frontolateral and temporoparietal cortical sites were stimulated, but it may have suppressed also the brain signals near the stimulation site. Effective connectivity originating from the speech-related areas may be studied even when speech areas are stimulated at least on the contralateral hemisphere where the signals were not suppressed that much.
- Open Access
- 27 March 2019
- Published by Springer Nature in Experimental Brain Research
- Vol. 237 (6) , 1503-1510
The effect of experimental pain on short-interval intracortical inhibition with multi-locus transcranial magnetic stimulation
Chronic neuropathic pain is known to alter the primary motor cortex (M1) function. Less is known about the normal, physiological effects of experimental neurogenic pain on M1. The objective of this study is to determine how short-interval intracortical inhibition (SICI) is altered in the M1 representation area of a muscle exposed to experimental pain compared to SICI of another muscle not exposed to pain. The cortical representation areas of the right abductor pollicis brevis (APB) and biceps brachii (BB) muscles of 11 subjects were stimulated with a multi-locus transcranial magnetic stimulation device while the resulting motor-evoked potentials (MEPs) were recorded with electromyography. Single- and paired-pulse TMS was administered in seven conditions, including one with the right hand placed in cold water. The stimulation intensity for the conditioning pulses in the paired-pulse examination was 80% of the resting motor threshold (RMT) of the stimulated site and 120% of RMT for both the test and single pulses. The paired-pulse MEP amplitudes were normalized with the mean amplitude of the single-pulse MEPs of the same condition and muscle. SICI was compared between conditions. After the cold pain, the normalized paired-pulse MEP amplitudes decreased in APB, but not in BB, indicating that SICI was potentially increased only in the cortical area of the muscle subjected to pain. These data suggest that SICI is increased in the M1 representation area of a hand muscle shortly after exposure to pain has ended, which implies that short-lasting pain can alter the inhibitory balance in M1.
- 27 March 2019
- Published by Springer Nature in Experimental Brain Research
- Vol. 237 (6) , 1503-1510
Open AccessThe effect of experimental pain on short-interval intracortical inhibition with multi-locus transcranial magnetic stimulation
Chronic neuropathic pain is known to alter the primary motor cortex (M1) function. Less is known about the normal, physiological effects of experimental neurogenic pain on M1. The objective of this study is to determine how short-interval intracortical inhibition (SICI) is altered in the M1 representation area of a muscle exposed to experimental pain compared to SICI of another muscle not exposed to pain. The cortical representation areas of the right abductor pollicis brevis (APB) and biceps brachii (BB) muscles of 11 subjects were stimulated with a multi-locus transcranial magnetic stimulation device while the resulting motor-evoked potentials (MEPs) were recorded with electromyography. Single- and paired-pulse TMS was administered in seven conditions, including one with the right hand placed in cold water. The stimulation intensity for the conditioning pulses in the paired-pulse examination was 80% of the resting motor threshold (RMT) of the stimulated site and 120% of RMT for both the test and single pulses. The paired-pulse MEP amplitudes were normalized with the mean amplitude of the single-pulse MEPs of the same condition and muscle. SICI was compared between conditions. After the cold pain, the normalized paired-pulse MEP amplitudes decreased in APB, but not in BB, indicating that SICI was potentially increased only in the cortical area of the muscle subjected to pain. These data suggest that SICI is increased in the M1 representation area of a hand muscle shortly after exposure to pain has ended, which implies that short-lasting pain can alter the inhibitory balance in M1.
- 17 September 2018
- Published by SAGE Publications in Brain Connectivity
- Vol. 8 (7) , 420-428
Individual Activation Patterns After the Stimulation of Different Motor Areas: A Transcranial Magnetic Stimulation–Electroencephalography Study
The combination of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) enables one to study effective connectivity and activation order in neuronal networks. To characterize effective connectivity originating from the primary motor cortex (M1), dorsal premotor area (PMd), and supplementary motor area (SMA). Three right-handed volunteers (two men, aged 25–30 years) participated in a navigated TMS–EEG experiment. M1, PMd, and SMA over the nondominant hemisphere were stimulated with 150 TMS pulses. Minimum-norm estimates were derived from the EEG data to estimate the spatial spreading of TMS-elicited neuronal activation on an individual level. The activation order of the cortical areas varied depending on the stimulated area. There were similarities and differences in the spatial distribution of the TMS-evoked potentials between subjects. Similarities in cortical activation patterns were seen at short poststimulus latencies and the differences at long latencies. This pilot study suggests that cortical activation patterns and the activation order of motor areas differ interindividually and depend on the stimulated motor area. It further indicates that TMS-activated effective connections or underlying structural connections vary between subjects. The spatial patterns of TMS-evoked potentials differ between subjects especially at long latencies, when probably more complex neuronal networks are active.
- 17 September 2018
- Published by SAGE Publications in Brain Connectivity
- Vol. 8 (7) , 420-428
Individual Activation Patterns After the Stimulation of Different Motor Areas: A Transcranial Magnetic Stimulation–Electroencephalography Study
The combination of transcranial magnetic stimulation (TMS) and electroencephalography (EEG) enables one to study effective connectivity and activation order in neuronal networks. To characterize effective connectivity originating from the primary motor cortex (M1), dorsal premotor area (PMd), and supplementary motor area (SMA). Three right-handed volunteers (two men, aged 25–30 years) participated in a navigated TMS–EEG experiment. M1, PMd, and SMA over the nondominant hemisphere were stimulated with 150 TMS pulses. Minimum-norm estimates were derived from the EEG data to estimate the spatial spreading of TMS-elicited neuronal activation on an individual level. The activation order of the cortical areas varied depending on the stimulated area. There were similarities and differences in the spatial distribution of the TMS-evoked potentials between subjects. Similarities in cortical activation patterns were seen at short poststimulus latencies and the differences at long latencies. This pilot study suggests that cortical activation patterns and the activation order of motor areas differ interindividually and depend on the stimulated motor area. It further indicates that TMS-activated effective connections or underlying structural connections vary between subjects. The spatial patterns of TMS-evoked potentials differ between subjects especially at long latencies, when probably more complex neuronal networks are active.