Gavin J. Macpherson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gavin J. Macpherson has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- Nicholas David Clement
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
13 shared publications - Chloe E. H. Scott
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
5 shared publications - David F. Hamilton
Research Centre for Health, Glasgow Caledonian University, Glasgow, UK
5 shared publications - Deborah J. MacDonald
Department of Orthopaedics, University of Edinburgh, Edinburgh, UK
5 shared publications - James T. Patton
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK
5 shared publications - Paul Gaston
Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK
4 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8268
Mapping Analysis to Predict the Associated EQ-5D-3L Utility Values from the Oxford Hip Score
Purpose: The aim was to assess mapping models to predict the EQ-5D-3L utility from the Oxford hip score (OHS) and validate these before and after total hip arthroplasty (THA). Methods: Separate retrospective cohorts of patients who had undergone THA in different centres were used to create (n = 3981) and validate (n = 7168) the prediction models. Patient demographics, body mass index (BMI), OHS and EQ-5D were collected preoperatively and one year postoperatively. Predictive models were formulated using generalised linear regression. Results: In the modelling cohort, mean OHS improved from 20.8 preoperatively to 39.6 postoperatively; the mean EQ-5D improved from 0.391 preoperatively to 0.788 postoperatively. Significant (p < 0.001) correlations were observed between OHS and EQ-5D preoperatively (r = 0.690) and postoperatively (r = 0.777) and for change (r = 0.611) and combined scores (r = 0.812). Four models predicting EQ-5D from OHS explained 38.5% to 65.9% of the variance. Age and BMI did not improve model fit. Predicted mean EQ-5D utilities differed statistically from observed values for most models, but all differences were below the minimal clinical important difference (MCID). Including individual OHS items marginally improved performance (<2%). External validation showed good agreement at the cohort level but lower accuracy for individual-level prediction (27.7% for change to 65.0% for postoperative scores to be within the MCID). Conclusions: The EQ-5D-3L utility index, on a cohort level, may be reliably estimated from the OHS. Predicted individual patient utility error beyond the MCID varied from one-third to more than two-thirds depending on the data assessed and so should not be employed for this purpose on a patient level.
- 23 October 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (21) , 8268
Open AccessMapping Analysis to Predict the Associated EQ-5D-3L Utility Values from the Oxford Hip Score
Purpose: The aim was to assess mapping models to predict the EQ-5D-3L utility from the Oxford hip score (OHS) and validate these before and after total hip arthroplasty (THA). Methods: Separate retrospective cohorts of patients who had undergone THA in different centres were used to create (n = 3981) and validate (n = 7168) the prediction models. Patient demographics, body mass index (BMI), OHS and EQ-5D were collected preoperatively and one year postoperatively. Predictive models were formulated using generalised linear regression. Results: In the modelling cohort, mean OHS improved from 20.8 preoperatively to 39.6 postoperatively; the mean EQ-5D improved from 0.391 preoperatively to 0.788 postoperatively. Significant (p < 0.001) correlations were observed between OHS and EQ-5D preoperatively (r = 0.690) and postoperatively (r = 0.777) and for change (r = 0.611) and combined scores (r = 0.812). Four models predicting EQ-5D from OHS explained 38.5% to 65.9% of the variance. Age and BMI did not improve model fit. Predicted mean EQ-5D utilities differed statistically from observed values for most models, but all differences were below the minimal clinical important difference (MCID). Including individual OHS items marginally improved performance (<2%). External validation showed good agreement at the cohort level but lower accuracy for individual-level prediction (27.7% for change to 65.0% for postoperative scores to be within the MCID). Conclusions: The EQ-5D-3L utility index, on a cohort level, may be reliably estimated from the OHS. Predicted individual patient utility error beyond the MCID varied from one-third to more than two-thirds depending on the data assessed and so should not be employed for this purpose on a patient level.
- Open Access
- 10 February 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (2) , 164-177
Total versus robotic-assisted unicompartmental knee replacement (TRAKER) for medial compartment osteorthritis: a randomized controlled trial
Aims: Unicompartmental knee arthroplasty (UKA) is associated with an accelerated recovery, improved functional outcomes, and retention of anatomical knee kinematics when compared to manual total knee arthroplasty (mTKA). UKA is not universally employed by all surgeons as there is a higher revision risk when compared to mTKA. Robotic arm-assisted (ra) UKA enables the surgeon to position the prosthesis more accurately when compared to manual UKA, and is associated with improved functional outcomes and a lower early revision risk. Non-randomized data suggests that, when compared to mTKA, raUKA has a clinically meaningful greater functional benefit. This protocol describes a randomized controlled trial that aims to evaluate the clinical and cost-effectiveness of raUKA compared to mTKA for individuals with isolated medial compartment osteoarthritis (OA).Methods: The total versus robotic-assisted unicompartmental knee arthroplasty (TRAKER) trial is a patient- and assessor-blinded, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary knee arthroplasty for primary medial compartment OA at a single NHS hospital (ClinicalTrials.gov NCT05290818). Participants will be randomly allocated on a 1:2 basis to either raUKA or mTKA, respectively. The primary analysis will compare the Oxford Knee Score (OKS) six months after surgery. Secondary outcomes measured at three, six, and 12 months include the OKS, Forgotten Joint Score, patient expectations, EuroQol five-dimension questionnaire (EQ-5D), and EQ-visual analogue scale (EQ-VAS), patient satisfaction, range of motion, postoperative complications, need for further surgery, resource use, and financial costs. Cost-effectiveness will be measured over a ten-year time span. A total of 159 patients will be randomized (n = 53 raUKA vs n = 106 mTKA) to obtain 80% power to detect a five-point difference in OKS between the groups six months after surgery.Conclusion: The trial findings will provide evidence about the clinical and cost-effectiveness of raUKA compared to mTKA in patients with isolated medial compartment OA. This will inform future National Institute for Health and Care Excellence guidelines on primary knee arthroplasty in the UK.Cite this article: Bone Jt Open 2025;6(2):164–177.
- 10 February 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 6 (2) , 164-177
Open AccessTotal versus robotic-assisted unicompartmental knee replacement (TRAKER) for medial compartment osteorthritis: a randomized controlled trial
Aims: Unicompartmental knee arthroplasty (UKA) is associated with an accelerated recovery, improved functional outcomes, and retention of anatomical knee kinematics when compared to manual total knee arthroplasty (mTKA). UKA is not universally employed by all surgeons as there is a higher revision risk when compared to mTKA. Robotic arm-assisted (ra) UKA enables the surgeon to position the prosthesis more accurately when compared to manual UKA, and is associated with improved functional outcomes and a lower early revision risk. Non-randomized data suggests that, when compared to mTKA, raUKA has a clinically meaningful greater functional benefit. This protocol describes a randomized controlled trial that aims to evaluate the clinical and cost-effectiveness of raUKA compared to mTKA for individuals with isolated medial compartment osteoarthritis (OA).Methods: The total versus robotic-assisted unicompartmental knee arthroplasty (TRAKER) trial is a patient- and assessor-blinded, pragmatic parallel two-arm randomized superiority trial of adults undergoing elective primary knee arthroplasty for primary medial compartment OA at a single NHS hospital (ClinicalTrials.gov NCT05290818). Participants will be randomly allocated on a 1:2 basis to either raUKA or mTKA, respectively. The primary analysis will compare the Oxford Knee Score (OKS) six months after surgery. Secondary outcomes measured at three, six, and 12 months include the OKS, Forgotten Joint Score, patient expectations, EuroQol five-dimension questionnaire (EQ-5D), and EQ-visual analogue scale (EQ-VAS), patient satisfaction, range of motion, postoperative complications, need for further surgery, resource use, and financial costs. Cost-effectiveness will be measured over a ten-year time span. A total of 159 patients will be randomized (n = 53 raUKA vs n = 106 mTKA) to obtain 80% power to detect a five-point difference in OKS between the groups six months after surgery.Conclusion: The trial findings will provide evidence about the clinical and cost-effectiveness of raUKA compared to mTKA in patients with isolated medial compartment OA. This will inform future National Institute for Health and Care Excellence guidelines on primary knee arthroplasty in the UK.Cite this article: Bone Jt Open 2025;6(2):164–177.
- Open Access
- 31 January 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (3) , 938
The Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis
Background/Objectives: As the rate of revision total hip arthroplasty (THA) has risen, there has been a drive to improve the technology in the manufacturing of the implants used. One recent advance has been 3-D printing of trabecular titanium implants to improve implant stability and osteointegration. The aim of this study was to review the clinical and radiological outcomes of these acetabular implants in revision THA. Methods: A manual search of the databases of the US National Library of medicine (PubMed/MEDLINE), Embase, and the Cochrane library was performed. The following keywords of “revision total hip arthroplasty” AND “acetabulum” AND “titanium” AND “porous” were utilised. Results: In total, 106 abstracts were identified during manual search of databases. In total, 11 studies reporting 4 different implants, with a total of 597 operated joints in 585 patients were included in this review. There were 349 (59.7%) female patients, and the mean age per study ranged from 56.0 to 78.4 years. The all-cause survival rate was 95.52% (95% CI: 92.37–97.96) at a mean follow up of 3.8 years (95% CI: 2.6–5.1). The 40 cases that required re-operation included 17 (2.8%) for infection, 14 (2.3%) instability, 2 (0.3%) for shell migration and 5 (0.8%) for aseptic loosening. The most commonly used patient reported outcome measure was the Harris Hip Score with the mean post-operative score of 86.7 (95% CI: 84.3–89.1). Conclusions: Trabecular titanium acetabular implants, when used in revision THA, resulted in excellent short- to mid-term outcomes with improved hip specific outcomes and a survivorship of 95.52% over the reported follow-up period. Future prospective studies evaluating long term outcomes are needed to make comparisons between more established solutions used in revision THA.
- 31 January 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (3) , 938
Open AccessThe Use of Highly Porous 3-D-Printed Titanium Acetabular Cups in Revision Total Hip Arthroplasty: A Systematic Review and Meta-Analysis
Background/Objectives: As the rate of revision total hip arthroplasty (THA) has risen, there has been a drive to improve the technology in the manufacturing of the implants used. One recent advance has been 3-D printing of trabecular titanium implants to improve implant stability and osteointegration. The aim of this study was to review the clinical and radiological outcomes of these acetabular implants in revision THA. Methods: A manual search of the databases of the US National Library of medicine (PubMed/MEDLINE), Embase, and the Cochrane library was performed. The following keywords of “revision total hip arthroplasty” AND “acetabulum” AND “titanium” AND “porous” were utilised. Results: In total, 106 abstracts were identified during manual search of databases. In total, 11 studies reporting 4 different implants, with a total of 597 operated joints in 585 patients were included in this review. There were 349 (59.7%) female patients, and the mean age per study ranged from 56.0 to 78.4 years. The all-cause survival rate was 95.52% (95% CI: 92.37–97.96) at a mean follow up of 3.8 years (95% CI: 2.6–5.1). The 40 cases that required re-operation included 17 (2.8%) for infection, 14 (2.3%) instability, 2 (0.3%) for shell migration and 5 (0.8%) for aseptic loosening. The most commonly used patient reported outcome measure was the Harris Hip Score with the mean post-operative score of 86.7 (95% CI: 84.3–89.1). Conclusions: Trabecular titanium acetabular implants, when used in revision THA, resulted in excellent short- to mid-term outcomes with improved hip specific outcomes and a survivorship of 95.52% over the reported follow-up period. Future prospective studies evaluating long term outcomes are needed to make comparisons between more established solutions used in revision THA.
- Open Access
- 28 May 2024
- Published by Bioscientifica in Journal of Endocrinology
- Vol. 262 (2)
Deletion of Hsd11b1 suppresses caloric restriction-induced bone marrow adiposity in male but not female mice
Bone marrow adipose tissue (BMAT) comprises >10% of total adipose mass in healthy humans. It increases in diverse conditions, including ageing, obesity, osteoporosis, glucocorticoid therapy, and notably, during caloric restriction (CR). BMAT potentially influences skeletal, metabolic, and immune functions, but the mechanisms of BMAT expansion remain poorly understood. Our hypothesis is that, during CR, excessive glucocorticoid activity drives BMAT expansion. The enzyme 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) amplifies glucocorticoid activity by catalysing intracellular regeneration of active glucocorticoids from inert 11-keto forms. Mice lacking 11β-HSD1 resist metabolic dysregulation and bone loss during exogenous glucocorticoid excess; thus, we hypothesised that 11β-HSD1 knockout mice would also resist excessive glucocorticoid action during CR, thereby restrining BMAT expansion and bone loss. To test this, we first confirmed that 11β-HSD1 is expressed in mouse and human bone marrow. We then investigated the effects of CR in male and female control and 11β-HSD1 knockout mice from 9 to 15 weeks of age. CR increased Hsd11b1 mRNA in adipose tissue and bone marrow. Deletion of Hsd11b1 did not alter bone or BMAT characteristics in mice fed a control diet and had little effect on tibial bone microarchitecture during CR. Notably, Hsd11b1 deletion attenuated the CR-induced increases in BMAT and prevented increases in bone marrow corticosterone in males but not females. This was not associated with suppression of glucocorticoid target genes in bone marrow. Instead, knockout males had increased progesterone in plasma and bone marrow. Together, our findings show that knockout of 11β-HSD1 prevents CR-induced BMAT expansion in a sex-specific manner and highlights progesterone as a potential new regulator of bone marrow adiposity.
- 28 May 2024
- Published by Bioscientifica in Journal of Endocrinology
- Vol. 262 (2)
Open AccessDeletion of Hsd11b1 suppresses caloric restriction-induced bone marrow adiposity in male but not female mice
Bone marrow adipose tissue (BMAT) comprises >10% of total adipose mass in healthy humans. It increases in diverse conditions, including ageing, obesity, osteoporosis, glucocorticoid therapy, and notably, during caloric restriction (CR). BMAT potentially influences skeletal, metabolic, and immune functions, but the mechanisms of BMAT expansion remain poorly understood. Our hypothesis is that, during CR, excessive glucocorticoid activity drives BMAT expansion. The enzyme 11β-hydroxysteroid dehydrogenase type 1 (11β-HSD1) amplifies glucocorticoid activity by catalysing intracellular regeneration of active glucocorticoids from inert 11-keto forms. Mice lacking 11β-HSD1 resist metabolic dysregulation and bone loss during exogenous glucocorticoid excess; thus, we hypothesised that 11β-HSD1 knockout mice would also resist excessive glucocorticoid action during CR, thereby restrining BMAT expansion and bone loss. To test this, we first confirmed that 11β-HSD1 is expressed in mouse and human bone marrow. We then investigated the effects of CR in male and female control and 11β-HSD1 knockout mice from 9 to 15 weeks of age. CR increased Hsd11b1 mRNA in adipose tissue and bone marrow. Deletion of Hsd11b1 did not alter bone or BMAT characteristics in mice fed a control diet and had little effect on tibial bone microarchitecture during CR. Notably, Hsd11b1 deletion attenuated the CR-induced increases in BMAT and prevented increases in bone marrow corticosterone in males but not females. This was not associated with suppression of glucocorticoid target genes in bone marrow. Instead, knockout males had increased progesterone in plasma and bone marrow. Together, our findings show that knockout of 11β-HSD1 prevents CR-induced BMAT expansion in a sex-specific manner and highlights progesterone as a potential new regulator of bone marrow adiposity.
- Open Access
- 24 October 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (10) , 808-816
Fifteen-year prospective longitudinal cohort study of outcomes following single radius total knee arthroplasty
Aims: This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up.Methods: From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed.Results: At 15 years, 28 patients were lost to follow-up (6.1%) and 221 patients (51.9%) had died, with the mean age of the remaining cohort reducing by four years. PROMs response rates among surviving patients were: one-year 63%; five-year 72%; ten-year 94%; and 15-year 59%. OKS and SF-12 scores changed significantly over 15 years (p < 0.001). The mean improvement in OKS was 18.8 (95% confidence (CI) 16.7 to 19.0) at one year. OKS peaked at five years (median 43 years) declining thereafter (p < 0.001), though at 15 years it remained 17.5 better than preoperatively. Age and sex did not alter this trajectory. A quarter of patients experienced a clinically significant decline (≥ 7) in OKS from five to ten years and from ten to 15 years. The SF-12 physical component score displayed a similar trajectory, peaking at one year (p < 0.001). Patient satisfaction was 88% at one, five, and ten years, and 94% at 15 years. In all, 15-year Kaplan-Meier survival was 97.6% (95% CI 96.0% to 99.2%) for any revision, and 98.9% (95% CI 97.9% to 99.9%) for aseptic revision.Conclusion: Improvements in PROMs were significant and maintained following single radius TKA, with OKS peaking at five years, and generic physical health peaking at one year. Patient satisfaction remained high at 15 years, at which point 2.4% had been revised.Cite this article: Bone Jt Open 2023;4(10):808–816.
- 24 October 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (10) , 808-816
Open AccessFifteen-year prospective longitudinal cohort study of outcomes following single radius total knee arthroplasty
Aims: This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up.Methods: From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed.Results: At 15 years, 28 patients were lost to follow-up (6.1%) and 221 patients (51.9%) had died, with the mean age of the remaining cohort reducing by four years. PROMs response rates among surviving patients were: one-year 63%; five-year 72%; ten-year 94%; and 15-year 59%. OKS and SF-12 scores changed significantly over 15 years (p < 0.001). The mean improvement in OKS was 18.8 (95% confidence (CI) 16.7 to 19.0) at one year. OKS peaked at five years (median 43 years) declining thereafter (p < 0.001), though at 15 years it remained 17.5 better than preoperatively. Age and sex did not alter this trajectory. A quarter of patients experienced a clinically significant decline (≥ 7) in OKS from five to ten years and from ten to 15 years. The SF-12 physical component score displayed a similar trajectory, peaking at one year (p < 0.001). Patient satisfaction was 88% at one, five, and ten years, and 94% at 15 years. In all, 15-year Kaplan-Meier survival was 97.6% (95% CI 96.0% to 99.2%) for any revision, and 98.9% (95% CI 97.9% to 99.9%) for aseptic revision.Conclusion: Improvements in PROMs were significant and maintained following single radius TKA, with OKS peaking at five years, and generic physical health peaking at one year. Patient satisfaction remained high at 15 years, at which point 2.4% had been revised.Cite this article: Bone Jt Open 2023;4(10):808–816.
- Open Access
- 18 October 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (10) , 782-790
Nexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE)
Nexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE)
- 18 October 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (10) , 782-790
Open AccessNexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE)
Nexus Evaluation Primary Trident II UNcemented shEll (NEPTUNE)
- Open Access
- 1 July 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (7) , 573-581
Mapping analysis to predict the associated EuroQol five-dimension three-level utility values from the Oxford Knee Score
Aims: The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA). Methods: A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models. Results: There were significant correlations between the OKS and EQ-5D-3L preoperatively ( r = 0.68; p < 0.001) and postoperatively ( r = 0.77; p < 0.001) and for the change in the scores ( r = 0.61; p < 0.001). Three different models (preoperative, postoperative, and change) were created. There were no significant differences between the actual and predicted mean EQ-5D-3L utilities at any timepoint or for change in the scores (p > 0.090) in the validation cohort. There was a significant correlation between the actual and predicted EQ-5D-3L utilities preoperatively ( r = 0.63; p < 0.001) and postoperatively ( r = 0.77; p < 0.001) and for the change in the scores ( r = 0.56; p < 0.001). Bland-Altman plots demonstrated that a lower utility was overestimated, and higher utility was underestimated. The individual predicted EQ-5D-3L that was within ± 0.05 and ± 0.010 (minimal clinically important difference (MCID)) of the actual EQ-5D-3L varied between 13% to 35% and 26% to 64%, respectively, according to timepoint assessed and change in the scores, but was not significantly different between the modelling and validation cohorts (p ≥ 0.148). Conclusion: The OKS can be used to estimate EQ-5D-3L. Predicted individual patient utility error beyond the MCID varied from one-third to two-thirds depending on timepoint assessed, but the mean for a cohort did not differ and could be employed for this purpose. Cite this article: Bone Jt Open 2022;3(7):573–581.
- 1 July 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (7) , 573-581
Open AccessMapping analysis to predict the associated EuroQol five-dimension three-level utility values from the Oxford Knee Score
Aims: The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA). Methods: A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models. Results: There were significant correlations between the OKS and EQ-5D-3L preoperatively ( r = 0.68; p < 0.001) and postoperatively ( r = 0.77; p < 0.001) and for the change in the scores ( r = 0.61; p < 0.001). Three different models (preoperative, postoperative, and change) were created. There were no significant differences between the actual and predicted mean EQ-5D-3L utilities at any timepoint or for change in the scores (p > 0.090) in the validation cohort. There was a significant correlation between the actual and predicted EQ-5D-3L utilities preoperatively ( r = 0.63; p < 0.001) and postoperatively ( r = 0.77; p < 0.001) and for the change in the scores ( r = 0.56; p < 0.001). Bland-Altman plots demonstrated that a lower utility was overestimated, and higher utility was underestimated. The individual predicted EQ-5D-3L that was within ± 0.05 and ± 0.010 (minimal clinically important difference (MCID)) of the actual EQ-5D-3L varied between 13% to 35% and 26% to 64%, respectively, according to timepoint assessed and change in the scores, but was not significantly different between the modelling and validation cohorts (p ≥ 0.148). Conclusion: The OKS can be used to estimate EQ-5D-3L. Predicted individual patient utility error beyond the MCID varied from one-third to two-thirds depending on timepoint assessed, but the mean for a cohort did not differ and could be employed for this purpose. Cite this article: Bone Jt Open 2022;3(7):573–581.
- Top Cited PapersOpen Access
- 1 May 2022
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 104-B (5) , 541-548
Robotic arm-assisted versus manual unicompartmental knee arthroplasty
Aims: This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). Methods: Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. Results: A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. Conclusion: MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541–548.
- 1 May 2022
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 104-B (5) , 541-548
Top Cited PapersOpen AccessRobotic arm-assisted versus manual unicompartmental knee arthroplasty
Aims: This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). Methods: Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. Results: A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. Conclusion: MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541–548.
- Open Access
- 27 February 2022
- Published by Wiley in Advances in Orthopedics
- Vol. 2022, 1-8
A Cost-Utility Analysis of Robotic Arm-Assisted Total Hip Arthroplasty: Using Robotic Data from the Private Sector and Manual Data from the National Health Service
Purpose. The aim was to assess the cost-effectiveness of robotic arm-assisted total hip arthroplasty (rTHA) compared with manual total hip arthroplasty (mTHA) and to assess the influence of annual volume on the relative cost-effectiveness of rTHA. Methods. A database of both rTHA (n = 48 performed in a private centre) and mTHA (n = 512 performed in the National Health Service) was used. Patient demographics, preoperative Oxford hip score, forgotten joint score, EuroQol 5-dimensional 3-level (EQ-5D), and postoperative EQ-5D were recorded. Two models for incremental cost-effectiveness ratios using cost per quality-adjusted life year (QALY) for rTHA were calculated based on a unit performing 100 rTHAs per year: 10-year follow-up and a lifetime time horizon (remaining life expectancy of a 69-year-old patient). Results. When adjusting for confounding factors, rTHA was independently associated with a 0.091 ( ) greater improvement in the EQ-5D compared to mTHA. This resulted in a 10-year time horizon cost per QALY for rTHA of £1,910 relative to mTHA, which increased to £2,349 per QALY when discounted (5%/year). When using the 10-year time horizon cost per QALY was approximately £3,000 for a centre undertaking 50 rTHAs per year and decreased to £1,000 for centre undertaking 200 rTHAs per year. Using a lifetime horizon, the incremental unadjusted cost per QALY gained was £980 and £1432 when discounted (5%/year) for rTHA compared with mTHA. Conclusions. Despite the increased cost associated with rTHA, it was a cost-effective intervention relative to mTHA due to the associated greater health-related quality of health gain, according to the EQ-5D outcome measure.
- 27 February 2022
- Published by Wiley in Advances in Orthopedics
- Vol. 2022, 1-8
Open AccessA Cost-Utility Analysis of Robotic Arm-Assisted Total Hip Arthroplasty: Using Robotic Data from the Private Sector and Manual Data from the National Health Service
Purpose. The aim was to assess the cost-effectiveness of robotic arm-assisted total hip arthroplasty (rTHA) compared with manual total hip arthroplasty (mTHA) and to assess the influence of annual volume on the relative cost-effectiveness of rTHA. Methods. A database of both rTHA (n = 48 performed in a private centre) and mTHA (n = 512 performed in the National Health Service) was used. Patient demographics, preoperative Oxford hip score, forgotten joint score, EuroQol 5-dimensional 3-level (EQ-5D), and postoperative EQ-5D were recorded. Two models for incremental cost-effectiveness ratios using cost per quality-adjusted life year (QALY) for rTHA were calculated based on a unit performing 100 rTHAs per year: 10-year follow-up and a lifetime time horizon (remaining life expectancy of a 69-year-old patient). Results. When adjusting for confounding factors, rTHA was independently associated with a 0.091 ( ) greater improvement in the EQ-5D compared to mTHA. This resulted in a 10-year time horizon cost per QALY for rTHA of £1,910 relative to mTHA, which increased to £2,349 per QALY when discounted (5%/year). When using the 10-year time horizon cost per QALY was approximately £3,000 for a centre undertaking 50 rTHAs per year and decreased to £1,000 for centre undertaking 200 rTHAs per year. Using a lifetime horizon, the incremental unadjusted cost per QALY gained was £980 and £1432 when discounted (5%/year) for rTHA compared with mTHA. Conclusions. Despite the increased cost associated with rTHA, it was a cost-effective intervention relative to mTHA due to the associated greater health-related quality of health gain, according to the EQ-5D outcome measure.
- Open Access
- 1 February 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (2) , 152-154
Infographic: Total hip arthroplasty in golfers
The British Editorial Society of Bone & Joint Surgery
- 1 February 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (2) , 152-154
Open AccessInfographic: Total hip arthroplasty in golfers
The British Editorial Society of Bone & Joint Surgery