RPRyszard Pogłód

Ryszard Pogłód

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryszard Pogłód has a total of 285 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Blood transfusion service in Poland in 2018

    by Aleksandra Rosiek, Anna Tomaszewska, Elżbieta Lachert, Jolanta Antoniewicz-Papis, Jolanta Kubis, Ryszard Pogłód, Magdalena Łętowska

    Background: Assessment of the basic aspects of the activity of the Polish Regional Blood Transfusion Centers (hereinafter referred to as Centers) in 2018. Materials and methods: Retrospective analysis of the 2018-data supplied by the Centers. Results: In 2018, blood and blood components were collected in 21 Centers and 132 local collection sites as well as during 13 189 mobile collections. The overall number of blood donors was estimated at 590 470; the majority were non-remunerated donors (589 897 — including 37 824 responders to donation appeals), 73 remunerated donors and 500 autologous donors. Most frequent were whole blood collections (1 184 311), least frequent — granulocyte concentrate collections (116) and red blood cell (RBC) collection by apheresis (31 donations). Whole blood was collected mostly in local collection sites (44.85%), less frequently in Centers (28.47%) and at mobile collection sites (26.67%). Most frequently prepared blood components were RBC — 1 161 600 units) and fresh frozen plasma (FFP — 1 298 216 units; 20.93% dedicated for clinical use). Platelet concentrates (PCs) collected by apheresis amounted to 50 255 units and 83 598 were whole blood-derived. Additional processing methods such as leukocyte depletion and irradiation were more frequently applied to PCs (32.56% leukocyte depleted, 1.37% irradiated, 58.07% both leukocyte depleted and irradiated) than to RBCs (17.29% leukocyte depleted, 0.31% irradiated, 8.94% both leukocyte depleted and irradiated). Pathogen reduction technologies were applied to 11.74% of PCs and 10.23% units of FFP issued for transfusion. In 2018 — for various reasons — 14 067 units of whole blood, 30 521 units of RBC, 49 979 units of FFP, 1376 units of cryoprecipitate, 5186 units of pooled PCs and 1625 of apheresis PCs were wasted. Conclusions: The study data may contribute to evaluation of the tendencies observed in Centers and may serve practical-benchmarking which in turn may prove beneficial to the transfusion community as a whole. Background: Assessment of the basic aspects of the activity of the Polish Regional Blood Transfusion Centers (hereinafter referred to as Centers) in 2018. Materials and methods: Retrospective analysis of the 2018-data supplied by the Centers. Results: In 2018, blood and blood components were collected in 21 Centers and 132 local collection sites as well as during 13 189 mobile collections. The overall number of blood donors was estimated at 590 470; the majority were non-remunerated donors (589 897 — including 37 824 responders to donation appeals), 73 remunerated donors and 500 autologous donors. Most frequent were whole blood collections (1 184 311), least frequent — granulocyte concentrate collections (116) and red blood cell (RBC) collection by apheresis (31 donations). Whole blood was collected mostly in local collection sites (44.85%), less frequently in Centers (28.47%) and at mobile collection sites (26.67%). Most frequently prepared blood components were RBC — 1 161 600 units) and fresh frozen plasma (FFP — 1 298 216 units; 20.93% dedicated for clinical use). Platelet concentrates (PCs) collected by apheresis amounted to 50 255 units and 83 598 were whole blood-derived. Additional processing methods such as leukocyte depletion and irradiation were more frequently applied to PCs (32.56% leukocyte depleted, 1.37% irradiated, 58.07% both leukocyte depleted and irradiated) than to RBCs (17.29% leukocyte depleted, 0.31% irradiated, 8.94% both leukocyte depleted and irradiated). Pathogen reduction technologies were applied to 11.74% of PCs and 10.23% units of FFP issued for transfusion. In 2018 — for various reasons — 14 067 units of whole blood, 30 521 units of RBC, 49 979 units of FFP, 1376 units of cryoprecipitate, 5186 units of pooled PCs and 1625 of apheresis PCs were wasted. Conclusions: The study data may contribute to evaluation of the tendencies observed in Centers and may serve practical-benchmarking which in turn may prove beneficial to the transfusion community as a whole.


  • An international investigation into AB plasma administration in hospitals: how many AB plasma units were infused? The HABSWIN study

    by Michelle P. Zeller, Rebecca Barty, Nancy M. Dunbar, Allahna Elahie, Peter Flanagan, Henk Garritsen, José Mauro Kutner, Monica B. Pagano, Ryszard Pogłód, Thomas S. Rogers, et al.

    BACKGROUND: Typical practice is to transfuse group‐specific plasma units; however, there are situations where group AB plasma (universal donor) is issued to group A, B, or O recipients. If demand for group AB plasma exceeds collections, there is potential for shortage. This project explored the patterns of group AB plasma utilization at hospitals around the world.STUDY DESIGN AND METHODS: The study had two phases: a survey that inquired about hospital group AB plasma inventory, policies, and transfusion practices and a retrospective review of 2014 calendar year data where participants submitted information on plasma disposition including ABO group of unit and recipient, transfusion location, and select indications. Recruitment occurred through snowball sampling. Descriptive analyses were performed.RESULTS: Survey data were received from 25 centers across 10 countries; of those, 15 participants contributed to the data collection component. These 15 centers transfused a total of 43,369 AB plasma units during the study period. Only 1496 of 5541 (27%) group AB plasma units were transfused to group AB recipients. Transfusion policies, practices, and patterns were variable across sites.CONCLUSION: Group AB plasma units are frequently transfused to non‐AB recipients. Whether transfusing 73% of group AB plasma units to non‐AB recipients is the ideal inventory management strategy remains to be determined.


  • Vox Sanguinis International Forum on platelet cryopreservation

    by C.S. Cohn, L.J. Dumont, M. Lozano, D.C. Marks, L. Johnson, S. Ismay, N. Bondar, F. T'SAs, A.P.H. Yokoyama, J.M. Kutner, et al.


  • Vox Sanguinis International Forum on platelet cryopreservation: Summary

    by C.S. Cohn, L.J. Dumont, M. Lozano, D.C. Marks, L. Johnson, S. Ismay, N. Bondar, F. T'SAs, A.P.H. Yokoyama, J.M. Kutner, et al.


  • Open Access

    An international investigation into O red blood cell unit administration in hospitals: the GRoup O Utilization Patterns (GROUP) study

    by Michelle P. Zeller, Rebecca Barty, Astrid Aandahl, Torunn O. Apelseth, Jeannie Callum, Nancy M. Dunbar, Allahna Elahie, Henk Garritsen, Helen Hancock, José Mauro Kutner, et al.

    BACKGROUND: Transfusion of group O blood to non‐O recipients, or transfusion of D– blood to D+ recipients, can result in shortages of group O or D– blood, respectively. This study investigated RBC utilization patterns at hospitals around the world and explored the context and policies that guide ABO blood group and D type selection practices.STUDY DESIGN AND METHODS: This was a retrospective study on transfusion data from the 2013 calendar year. This study included a survey component that asked about hospital RBC selection and transfusion practices and a data collection component where participants submitted information on RBC unit disposition including blood group and D type of unit and recipient. Units administered to recipients of unknown ABO or D group were excluded.RESULTS: Thirty‐eight hospitals in 11 countries responded to the survey, 30 of which provided specific RBC unit disposition data. Overall, 11.1% (21,235/191,397) of group O units were transfused to non‐O recipients; 22.6% (8777/38,911) of group O D– RBC units were transfused to O D+ recipients, and 43.2% (16,800/38,911) of group O D– RBC units were transfused to recipients that were not group O D–. Disposition of units and hospital transfusion policy varied within and across hospitals of different sizes, with transfusion of group O D– units to non‐group O D– patients ranging from 0% to 33%.CONCLUSION: A significant proportion of group O and D– RBC units were transfused to compatible, nonidentical recipients, although the frequency of this practice varied across sites.


  • Development of RBC transfusion indications and the collection of patient‐specific pre‐transfusion information: summary

    by M. H. Yazer, L. van de Watering, M. Lozano, S. Sirdesai, K. Rushford, E. M. Wood, A. P. Yokoyama, J. M. Kutner, Y. Lin, J. Callum, et al.


  • Development of RBC transfusion indications and the collection of patient-specific pre-transfusion information

    by M. H. Yazer, L. van de Watering, M. Lozano, S. Sirdesai, K. Rushford, E. M. Wood, A. P. Yokoyama, J. M. Kutner, Y. Lin, J. Callum, et al.

  • An international survey on the role of the hospital transfusion committee

    by Mark H. Yazer, Miguel Lozano, Mark Fung, Jose Kutner, Michael F. Murphy, Torunn Oveland Apelseth, Ryszard Pogłód, Kathleen Selleng, Alan Tinmouth, Silvano Wendel, et al.

    BACKGROUND: Hospital transfusion committees (HTCs) can oversee all aspects of transfusion practice at a hospital. This survey sought to identify which quality variables were being reported at HTCs around the world.STUDY DESIGN AND METHODS: A working party composed of members of the Biomedical Excellence for Safer Transfusion (BEST) collaborative developed a survey of quality variables that could be potentially presented at HTC meetings. The survey was electronically sent to all BEST members who were encouraged to complete it if they were active on an HTC and to send it to other colleagues with similar experience. An expert panel was convened to determine which quality variables are the most important for review at HTC meetings.RESULTS: There were 121 respondents; the majority were from Europe (52%), Asia (19%), or North America (19%). Most respondents (68%) were at university hospitals. Of the 117 (97%) respondents with an HTC, the committee most often met quarterly (42%) and reviewed transfusion reactions (79%) and risk management–reported events (52%). The HTCs most commonly included transfusion medicine physicians, anesthesiologists, and other physicians who regularly transfuse blood products. Some of the most commonly reported quality variables included number of blood products transfused, wasted, and expired and the number of improperly labeled specimens. The expert panel analysis revealed that some variables that were deemed important were not being frequently reported at HTCs.CONCLUSION: There is variability in the variables being reported at HTCs around the world with some important variables not frequently reported.


  • Nietypowa lokalizacja złogów amyloidu w szpiczaku plazmocytowym

    by Jacek Szymańczyk, Ryszard Pogłód, Maria Kraj, Agnieszka Michalska, Monika Prochorec-Sobieszek, Janusz Szymańczyk

  • Open Access

    The Crossmatch/Issue Ratio

    by Mark H. Yazer, Ramir Alcantara, Pouneh Beizai, Nicole L. Draper, Sarah K. Harm, Jose M. Kutner, David Lin, Ryszard Poglod, Thomas S. Rogers, Claess H. Sørensen, et al.

    Objectives: To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio. Methods: An electronic survey was disseminated to hospital transfusion services collecting details about RBC crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio. Results: Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents, and the mean ± SD was 1.30 ± 0.34. There was no difference in C/I ratios between services that use the electronic or serologic crossmatch techniques ( P = .49). The ratio was the same at the four sites that crossmatch RBCs at the time of issue compared with the time of order receipt (mean ± SD, 1.11 ± 0.09 vs. 1.35 ± 0.36, respectively; P = .19). Conclusions: Electronic crossmatching is common, and the C/I ratio can be an indicator of efficiency.