Emir Özçalışkan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emir Özçalışkan has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Sinan Akgöl
Ege University
6 shared publications Adil Denizli
E Department of Chemistry , Hacettepe University Faculty of Science , Ankara , Turkey
4 shared publications- Deniz Aktaş Uygun
Aydın Adnan Menderes University, Faculty of Science, Department of Chemistry, Aydın, Türkiye
4 shared publications - Murat Uygun
Adnan Menderes University
3 shared publications - Ceren Türkcan
BEYKENT ÜNİVERSİTES
2 shared publications Hasan Demiroğlu
Department of Chemistry, Faculty of Arts and Science, Celal Bayar University, Manisa, Turkey
2 shared publications
Latest Publications
- 5 November 2018
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 29 (18) , 2218-2236
Synthesis and characterization of albumin imprinted polymeric hydrogel membranes for proteomic studies
In this presented study, a novel molecularly imprinted polymeric hydrogel membranes (PHMs) were developed to use for the albumin depletion studies. For this, albumin imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-(L)-phenylalanine methyl ester) polymeric hydrogel membranes [p(HEMA-MAP) PHMs] were synthesized by the photopolymerization technique, and then characterized by SEM, EDX, FT-IR and swelling studies. Synthesized PHMs had spherical structure and the MAP monomer incorporation onto the PHMs was determined by EDX analysis by using nitrogen stoichiometry. Also, the swelling ratio of the albumin imprinted p(HEMA-MAP) PHMs was determined as 215%. The optimum albumin adsorption condition (adsorption capacity, medium pH, adsorption rate, temperature, ionic strength) were studied and the maximum albumin adsorption capacity was found to be as 34.28 mg/g PHMs. Selectivity experiments were also carried out with the presence of the competitive proteins such as lysozyme and amylase, and the results demonstrated that the albumin imprinted p(HEMA-MAP) PHMs showed high affinity towards the BSA molecules than the competitive proteins of lysozyme and amylase. Adsorbed albumin was desorbed from the PHMs by 1.0 M of NaCl, and the reusability of the imprinted PHMs was also demonstrated for five successive adsorption-desorption cycles without any significant loss in the albumin adsorption capacity. As an application, sodium-dodecyl sulfate polyacrylamide gel electrophoresis was used to indicate the albumin depletion efficiency of albumin imprinted p(HEMA-MAP) PHMs. This presented study showed that, these imprinted membranes are promising for proteomic studies and applications, and can be used for the investigations for human diagnostics.
- 5 November 2018
- Published by Taylor & Francis in Journal of Biomaterials Science, Polymer Edition
- Vol. 29 (18) , 2218-2236
Synthesis and characterization of albumin imprinted polymeric hydrogel membranes for proteomic studies
In this presented study, a novel molecularly imprinted polymeric hydrogel membranes (PHMs) were developed to use for the albumin depletion studies. For this, albumin imprinted poly(2-hydroxyethyl methacrylate-N-methacryloyl-(L)-phenylalanine methyl ester) polymeric hydrogel membranes [p(HEMA-MAP) PHMs] were synthesized by the photopolymerization technique, and then characterized by SEM, EDX, FT-IR and swelling studies. Synthesized PHMs had spherical structure and the MAP monomer incorporation onto the PHMs was determined by EDX analysis by using nitrogen stoichiometry. Also, the swelling ratio of the albumin imprinted p(HEMA-MAP) PHMs was determined as 215%. The optimum albumin adsorption condition (adsorption capacity, medium pH, adsorption rate, temperature, ionic strength) were studied and the maximum albumin adsorption capacity was found to be as 34.28 mg/g PHMs. Selectivity experiments were also carried out with the presence of the competitive proteins such as lysozyme and amylase, and the results demonstrated that the albumin imprinted p(HEMA-MAP) PHMs showed high affinity towards the BSA molecules than the competitive proteins of lysozyme and amylase. Adsorbed albumin was desorbed from the PHMs by 1.0 M of NaCl, and the reusability of the imprinted PHMs was also demonstrated for five successive adsorption-desorption cycles without any significant loss in the albumin adsorption capacity. As an application, sodium-dodecyl sulfate polyacrylamide gel electrophoresis was used to indicate the albumin depletion efficiency of albumin imprinted p(HEMA-MAP) PHMs. This presented study showed that, these imprinted membranes are promising for proteomic studies and applications, and can be used for the investigations for human diagnostics.
- 1 September 2017
- Published by European Respiratory Society (ERS)
- Vol. 50 (suppl 61) , PA1215
Late Breaking Abstract - Implementation of universal valid methodology in the diagnosis of occupational asthma(Ege University Translational Pulmonology Research Group [EgeTPAG])
Widespread belief from developing countries is the implementation of Specific Inhalation Challenge Tests (SICTs)are not quite feasible and can be risky in lower healthcare facilities. The work of setting up a SICTs-Lab started with scientific support of EgeTPAG-Advisory Board Members from FIOH in 2014.A multidisciplinary structure was constituted by Pulmonary/Allergy-immunology/PublicHealth/ Chemisty/Biology to implement of methodology. With Turkey’s first Occupational Fellowship Program, SICTs were officially started in spring 2016. Now, in spring 2017 we are presenting our first year’s very recent data. Among 41 patients who were referred to us, five patients (%12.19) diagnosed as OA with support of SICTs. Two painters, two bakers, one carpenter had work-related dyspnea and history of wheezing during worktimes and common shared features of them were having inconsistent asthma findings. Following negative placebo challenge tests, patients were exposed to their culprit agent in a specifically manufactured challenge cabin in Izmir, as faithful the original one in Helsinki. Ambient levels of particulate matter concentrations in the cabin were continuously monitored and kept under permitted exposure limits.FEV1&PEF monitoring kept continue for 8-hours after SICT and the data recorded to OASYS computer program. In the first year of their establishment SICTs have been very helpful either exclude or confirmation of diagnosis of OA. Unlike the common belief of those who hesitate to apply them, they were very safe and economically reasonable. The implementation to a developing country was not easy, but possible with right team and scientific support.
- 1 September 2017
- Published by European Respiratory Society (ERS)
- Vol. 50 (suppl 61) , PA1215
Late Breaking Abstract - Implementation of universal valid methodology in the diagnosis of occupational asthma(Ege University Translational Pulmonology Research Group [EgeTPAG])
Widespread belief from developing countries is the implementation of Specific Inhalation Challenge Tests (SICTs)are not quite feasible and can be risky in lower healthcare facilities. The work of setting up a SICTs-Lab started with scientific support of EgeTPAG-Advisory Board Members from FIOH in 2014.A multidisciplinary structure was constituted by Pulmonary/Allergy-immunology/PublicHealth/ Chemisty/Biology to implement of methodology. With Turkey’s first Occupational Fellowship Program, SICTs were officially started in spring 2016. Now, in spring 2017 we are presenting our first year’s very recent data. Among 41 patients who were referred to us, five patients (%12.19) diagnosed as OA with support of SICTs. Two painters, two bakers, one carpenter had work-related dyspnea and history of wheezing during worktimes and common shared features of them were having inconsistent asthma findings. Following negative placebo challenge tests, patients were exposed to their culprit agent in a specifically manufactured challenge cabin in Izmir, as faithful the original one in Helsinki. Ambient levels of particulate matter concentrations in the cabin were continuously monitored and kept under permitted exposure limits.FEV1&PEF monitoring kept continue for 8-hours after SICT and the data recorded to OASYS computer program. In the first year of their establishment SICTs have been very helpful either exclude or confirmation of diagnosis of OA. Unlike the common belief of those who hesitate to apply them, they were very safe and economically reasonable. The implementation to a developing country was not easy, but possible with right team and scientific support.
- 27 September 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (10) , 1-24
Synthesis and biodistribution of novel magnetic-poly(HEMA–APH) nanopolymer radiolabeled with iodine-131 and investigation its fate in vivo for cancer therapy
- 27 September 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (10) , 1-24
Synthesis and biodistribution of novel magnetic-poly(HEMA–APH) nanopolymer radiolabeled with iodine-131 and investigation its fate in vivo for cancer therapy
- 19 August 2013
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 56 (14) , 708-716
Radiolabeling of new generation magnetic poly(HEMA–MAPA) nanoparticles with 131I and preliminary investigation of its radiopharmaceutical potential using albino Wistar rats
In this study, N‐methacryloyl‐l‐phenylalanine (MAPA) containing poly(2‐hydroxyethylmethacrylate) (HEMA)‐based magnetic poly(HEMA–MAPA) nanobeads [mag‐poly(HEMA–MAPA)] were radiolabeled with 131I [131I‐mag‐poly(HEMA–MAPA)], and the radiopharmaceutical potential of 131I‐mag‐poly(HEMA–MAPA) was investigated. Quality control studies were carried out by radiochromatographic method to be sure that 131I binded to mag‐poly(HEMA–MAPA) efficiently. In this sense, binding yield of 131I‐mag‐poly(HEMA–MAPA) was found to be about 95–100%. In addition to this, optimum radiodination conditions for 131I‐mag‐poly(HEMA–MAPA) were determined by thin‐layer radiochromatography studies. In addition to thin‐layer radiochromatography studies, lipophilicity (partition coefficient) and stability studies for 131I‐mag‐poly(HEMA–MAPA) were realized. It was determined that lipophilicities of mag‐poly(HEMA–MAPA) and 131I‐mag‐poly(HEMA–MAPA) were 0.12 ± 0.01 and 1.79 ± 0.76 according to ACD/logP algorithm program, respectively. Stability of the radiolabeled compound was investigated in time intervals given as 0, 30, 60, 180, and 1440 min. It was found that 131I‐mag‐poly(HEMA–MAPA) existed as a stable complex in rat serum within 60 min. After that, biodistribution and scintigraphy studies were carried out by using albino Wistar rats. It was determined that the most important 131I activity uptake was observed in the breast, the ovary, and the pancreas. Scintigraphy studies well supported biodistribution results. Copyright © 2013 John Wiley & Sons, Ltd.
- 19 August 2013
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 56 (14) , 708-716
Radiolabeling of new generation magnetic poly(HEMA–MAPA) nanoparticles with 131I and preliminary investigation of its radiopharmaceutical potential using albino Wistar rats
In this study, N‐methacryloyl‐l‐phenylalanine (MAPA) containing poly(2‐hydroxyethylmethacrylate) (HEMA)‐based magnetic poly(HEMA–MAPA) nanobeads [mag‐poly(HEMA–MAPA)] were radiolabeled with 131I [131I‐mag‐poly(HEMA–MAPA)], and the radiopharmaceutical potential of 131I‐mag‐poly(HEMA–MAPA) was investigated. Quality control studies were carried out by radiochromatographic method to be sure that 131I binded to mag‐poly(HEMA–MAPA) efficiently. In this sense, binding yield of 131I‐mag‐poly(HEMA–MAPA) was found to be about 95–100%. In addition to this, optimum radiodination conditions for 131I‐mag‐poly(HEMA–MAPA) were determined by thin‐layer radiochromatography studies. In addition to thin‐layer radiochromatography studies, lipophilicity (partition coefficient) and stability studies for 131I‐mag‐poly(HEMA–MAPA) were realized. It was determined that lipophilicities of mag‐poly(HEMA–MAPA) and 131I‐mag‐poly(HEMA–MAPA) were 0.12 ± 0.01 and 1.79 ± 0.76 according to ACD/logP algorithm program, respectively. Stability of the radiolabeled compound was investigated in time intervals given as 0, 30, 60, 180, and 1440 min. It was found that 131I‐mag‐poly(HEMA–MAPA) existed as a stable complex in rat serum within 60 min. After that, biodistribution and scintigraphy studies were carried out by using albino Wistar rats. It was determined that the most important 131I activity uptake was observed in the breast, the ovary, and the pancreas. Scintigraphy studies well supported biodistribution results. Copyright © 2013 John Wiley & Sons, Ltd.
- 10 July 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (8) , 1-11
New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater
- 10 July 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (8) , 1-11
New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 532-536
Synthesis and characterization of amino acid containing Cu(II) chelated nanoparticles for lysozyme adsorption
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 532-536
Synthesis and characterization of amino acid containing Cu(II) chelated nanoparticles for lysozyme adsorption
- 1 March 2012
- Published by Elsevier in Journal of Chromatography B
- Vol. 887-888, 73-78
Concanavalin A immobilized poly(ethylene glycol dimethacrylate) based affinity cryogel matrix and usability of invertase immobilization
- 1 March 2012
- Published by Elsevier in Journal of Chromatography B
- Vol. 887-888, 73-78
Concanavalin A immobilized poly(ethylene glycol dimethacrylate) based affinity cryogel matrix and usability of invertase immobilization