Tat'Jana Klimova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tat'Jana Klimova has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
D.M. Dubinin
National Research, System Operator (SO), Moscow, Russia
2 shared publications- O. O. Nikolaeva
National Research University, Moscow Power Engineering Institute, Moscow, Russia
2 shared publications S.V. Pletnev
National Research, University «MPEI», Moscow, Russia
2 shared publicationsV.A. Revyakin
National Research, University «MPEI», Moscow, Russia
2 shared publicationsA. D. Krasnoslov
Relay Control and Automation of Electrical Power Systems, National Research University «MPEI», Moscow, Russia
1 shared publicationA. I. Kovalenko
Dept. of relay protection and automation of electrical power systems, Moscow Power Engineering University, Moscow, Russian Federation
1 shared publication
Latest Publications
- 1 January 2023
- Published by Nizhny Novgorod State Technical University n.a. R.E. Alekseev in Интеллектуальная электротехника
- No. 1,p. 102-117
ESTIMATION OF PARAMETERS OF TWO-WINDING TRANSFORMER EQUIVALENT CIRCUIT BASED ON PMU
- 1 January 2023
- Published by Nizhny Novgorod State Technical University n.a. R.E. Alekseev in Интеллектуальная электротехника
- No. 1,p. 102-117
ESTIMATION OF PARAMETERS OF TWO-WINDING TRANSFORMER EQUIVALENT CIRCUIT BASED ON PMU
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-19
Monitoring Of Harmonic And Subharmonic Vibrations During The Operation Of The Wind Farm
To date, the use of synchronized vector measurement devices (PMU) makes it possible to implement distributed monitoring systems that differ from classical SCADA measurements (Supervisory Control And Data Acquisition). Since the technology of synchronized vector measurements allows obtaining high-precision estimates of all parameters of sinusoidal oscillations of industrial frequency, including information about the phase angle, with maximum speed and time synchronization with an accuracy of 1 microsecond compared to SCADA systems, these measurements can be used in the analysis of various dynamic processes and for their monitoring in real time. Such processes in the network are power fluctuations, low-frequency fluctuations, complex disturbances, cascade shutdowns and many other emergency situations that can affect the stability of the power system.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-19
Monitoring Of Harmonic And Subharmonic Vibrations During The Operation Of The Wind Farm
To date, the use of synchronized vector measurement devices (PMU) makes it possible to implement distributed monitoring systems that differ from classical SCADA measurements (Supervisory Control And Data Acquisition). Since the technology of synchronized vector measurements allows obtaining high-precision estimates of all parameters of sinusoidal oscillations of industrial frequency, including information about the phase angle, with maximum speed and time synchronization with an accuracy of 1 microsecond compared to SCADA systems, these measurements can be used in the analysis of various dynamic processes and for their monitoring in real time. Such processes in the network are power fluctuations, low-frequency fluctuations, complex disturbances, cascade shutdowns and many other emergency situations that can affect the stability of the power system.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-20
Investigation Of Switching And Emergency Modes Of Operation Of A 500 KV CSR To Study The Behavior Of Relay Protection
Shunt reactors controlled by magnetization (hereinafter - CSR) are designed to regulate reactive power and voltage. They can be connected to substation buses or to high voltage overhead or cable lines. At the same time, their relay protection has a number of features due to the principle of operation of CSR, however, it is performed using serial or specialized microprocessor terminals used to organize relay protection of transformer-type equipment.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-20
Investigation Of Switching And Emergency Modes Of Operation Of A 500 KV CSR To Study The Behavior Of Relay Protection
Shunt reactors controlled by magnetization (hereinafter - CSR) are designed to regulate reactive power and voltage. They can be connected to substation buses or to high voltage overhead or cable lines. At the same time, their relay protection has a number of features due to the principle of operation of CSR, however, it is performed using serial or specialized microprocessor terminals used to organize relay protection of transformer-type equipment.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-20
Analysis Of Phasor Measurment Units Operation Under Various Grid Conditions
At the present, phasor measurement units (PMU) are widely used in systems for monitoring and analyzing the state of electrical grid. Phasor technologies allow you to solve a number of problems related to the accuracy of perception and processing of information, bandwidth, performance, etc. PMU can significantly reduce the network congestion, when transmitting the most complete information in automated control systems. However, any measuring device has measurement errors that negatively affect the quality of the information received. Measurement errors often cause inaccuracies or latency in the transmission of information to other devices. Therefore, it is necessary to analyze the distribution of the PMU measurement error. As shown in [1], the main sources of PMU error are signal sensors and an algorithms for obtaining estimates of current and voltage vectors. Voltage and current transformers (VT and CT) used to feed raw data to the PMU usually have problem concerning saturation of steel core, the maximum amplitude error of measurement class transformers is 1%, protection class transformers are 10%, and the maximum phase error is 6 mrad (9 mrad for CT). VT and CT are the main source of errors for PMU [1]. In this paper, the analysis of the functioning of the PMU in case of connecting the PMU to various CT and VT is carried out. Operation errors are compared with signals from measuring CT and CT for PACS‘s purposes and more accurate sensors. The accuracy of the operation is evaluated with connecting to optical CT (TV). The greatest interest is caused by the influence of the magnetic saturation of the measuring CT on the estimation of the PMU error. PMUs operate in a network where various disturbances, including short circuits, are possible. At the same time, the short-circuit current significantly exceeds the current range at which the specified and certified accuracy of the PMU is realized. In addition, measuring current transformers have residual magnetization, which also leads to an increase the PMU errors. The paper considers the dependence of the accuracy of the PMU readings on various factors, such as the parameters of the network mode, the level of the short-circuit current, its nature (taking into account the aperiodic component), the accuracy class of the CT (VT), the location of the PMU in the secondary circuit at the power facility, various perturbations that cause a change in the state of the magnetic system of measuring CT.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-20
Analysis Of Phasor Measurment Units Operation Under Various Grid Conditions
At the present, phasor measurement units (PMU) are widely used in systems for monitoring and analyzing the state of electrical grid. Phasor technologies allow you to solve a number of problems related to the accuracy of perception and processing of information, bandwidth, performance, etc. PMU can significantly reduce the network congestion, when transmitting the most complete information in automated control systems. However, any measuring device has measurement errors that negatively affect the quality of the information received. Measurement errors often cause inaccuracies or latency in the transmission of information to other devices. Therefore, it is necessary to analyze the distribution of the PMU measurement error. As shown in [1], the main sources of PMU error are signal sensors and an algorithms for obtaining estimates of current and voltage vectors. Voltage and current transformers (VT and CT) used to feed raw data to the PMU usually have problem concerning saturation of steel core, the maximum amplitude error of measurement class transformers is 1%, protection class transformers are 10%, and the maximum phase error is 6 mrad (9 mrad for CT). VT and CT are the main source of errors for PMU [1]. In this paper, the analysis of the functioning of the PMU in case of connecting the PMU to various CT and VT is carried out. Operation errors are compared with signals from measuring CT and CT for PACS‘s purposes and more accurate sensors. The accuracy of the operation is evaluated with connecting to optical CT (TV). The greatest interest is caused by the influence of the magnetic saturation of the measuring CT on the estimation of the PMU error. PMUs operate in a network where various disturbances, including short circuits, are possible. At the same time, the short-circuit current significantly exceeds the current range at which the specified and certified accuracy of the PMU is realized. In addition, measuring current transformers have residual magnetization, which also leads to an increase the PMU errors. The paper considers the dependence of the accuracy of the PMU readings on various factors, such as the parameters of the network mode, the level of the short-circuit current, its nature (taking into account the aperiodic component), the accuracy class of the CT (VT), the location of the PMU in the secondary circuit at the power facility, various perturbations that cause a change in the state of the magnetic system of measuring CT.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-14
Using the Fourier Transform of the Half-Cycle to Enhance the Application of the PMU
Historically, power distribution systems did not require elaborate monitoring schemes. With radial topology and one-way power flow, it was only necessary to evaluate the envelope of design conditions (i.e., peak loads or fault currents), rather than continually observe the operating state. But the growth of distributed energy resources, such as renewable generation, electric vehicles, and demand response programs, introduces more short-term and unpredicted fluctuations and disturbances [1] . This suggests a need for more refined measurement, given both the challenge of managing increased variability and uncertainty and the presence of a higher level of narrowband and broadband interference and measurement noise.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-14
Using the Fourier Transform of the Half-Cycle to Enhance the Application of the PMU
Historically, power distribution systems did not require elaborate monitoring schemes. With radial topology and one-way power flow, it was only necessary to evaluate the envelope of design conditions (i.e., peak loads or fault currents), rather than continually observe the operating state. But the growth of distributed energy resources, such as renewable generation, electric vehicles, and demand response programs, introduces more short-term and unpredicted fluctuations and disturbances [1] . This suggests a need for more refined measurement, given both the challenge of managing increased variability and uncertainty and the presence of a higher level of narrowband and broadband interference and measurement noise.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Laam Complex Realization Issues with Using of PMU's Data
There are some areas in electrical power system (EPS) which have asynchronous mode (AM) appearance probability. AM is determined as one of the hardest and the most dangerous emergency modes in EPS. This is connected with disturbance of generator and electrical station parallel work stability [1] . It leads to primary damage of electrical equipment because of the huge current in generator stator winding. Therefore, the disturbance of the generator and electrical station parallel work stability is the reason for decrease in auxiliary mechanism productivity at electrical stations. These effects cause customer electrical supply disturbance and are connected with critical economic losses [2] . Therefore, it is vital to determine AM selectively in appropriate time and to recover normal work mode of EPS.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-9
Laam Complex Realization Issues with Using of PMU's Data
There are some areas in electrical power system (EPS) which have asynchronous mode (AM) appearance probability. AM is determined as one of the hardest and the most dangerous emergency modes in EPS. This is connected with disturbance of generator and electrical station parallel work stability [1] . It leads to primary damage of electrical equipment because of the huge current in generator stator winding. Therefore, the disturbance of the generator and electrical station parallel work stability is the reason for decrease in auxiliary mechanism productivity at electrical stations. These effects cause customer electrical supply disturbance and are connected with critical economic losses [2] . Therefore, it is vital to determine AM selectively in appropriate time and to recover normal work mode of EPS.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-26
The Possiblity of Using Phasor Measurement Units for the Distance Determination to the Disturbance Point
One of the issues of current importance is using phasor measurements unit (PMU) for the Wide Area Monitoring, Protection and Control System (WAMPAC). However, there is no clear understanding of the possibility of implementing relay protection functions based on these devices when filtering electrical quantities signals. Since the technology of synchronized vector measurements is relatively young in the electric power industry, various studies are currently being carried out on the applicability of the PMU functions in relay protection. Moreover, new calculation algorithms implemented in these devices are proposed. There is an ever-increasing introduction of PMU at electric power facilities as part of the WAMS complex for collecting and analyzing information both online and for subsequent analysis in order to monitor network parameters and equipment. The problems of determining the type of disturbance from the measurements obtained by PMU installed at various points of the power grid are considered worldwide. It is advisable to consider the possibility of estimating the distance to the point of application of the disturbance.
- 22 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-26
The Possiblity of Using Phasor Measurement Units for the Distance Determination to the Disturbance Point
One of the issues of current importance is using phasor measurements unit (PMU) for the Wide Area Monitoring, Protection and Control System (WAMPAC). However, there is no clear understanding of the possibility of implementing relay protection functions based on these devices when filtering electrical quantities signals. Since the technology of synchronized vector measurements is relatively young in the electric power industry, various studies are currently being carried out on the applicability of the PMU functions in relay protection. Moreover, new calculation algorithms implemented in these devices are proposed. There is an ever-increasing introduction of PMU at electric power facilities as part of the WAMS complex for collecting and analyzing information both online and for subsequent analysis in order to monitor network parameters and equipment. The problems of determining the type of disturbance from the measurements obtained by PMU installed at various points of the power grid are considered worldwide. It is advisable to consider the possibility of estimating the distance to the point of application of the disturbance.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-22
Determination of types of disturbances and asymmetries in the electric network using PMU measurements
The identification of disturbances and asymmetries that occur in the network for a number of different reasons are important parts of operational-dispatching management. Accurate and timely characterization of disturbances occurring in the power system will improve the quality of power system management. In turn, early detection of abnormal operating conditions is necessary to maintain normal operation of the intact part of the power system, since the conditions in question lead to a voltage, current and frequency deviation, which may cause a loss of stability of the power system and damages of equipment and lines. In this paper, data from phasor measurement units (PMU) obtained in real time are used for solving the considered problem. This allows accelerating the detection of abnormal operating conditions and disturbance analysis by determining the type of disturbance / type of fault and showing the obtained results.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-22
Determination of types of disturbances and asymmetries in the electric network using PMU measurements
The identification of disturbances and asymmetries that occur in the network for a number of different reasons are important parts of operational-dispatching management. Accurate and timely characterization of disturbances occurring in the power system will improve the quality of power system management. In turn, early detection of abnormal operating conditions is necessary to maintain normal operation of the intact part of the power system, since the conditions in question lead to a voltage, current and frequency deviation, which may cause a loss of stability of the power system and damages of equipment and lines. In this paper, data from phasor measurement units (PMU) obtained in real time are used for solving the considered problem. This allows accelerating the detection of abnormal operating conditions and disturbance analysis by determining the type of disturbance / type of fault and showing the obtained results.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-18
Application of Neural Network to Determine Parameters of the AEC of Synchronous Generator using Phasor Measurement Units
Nowadays, there is a large number of phasor measurement units (PMU) installed in the power systems, which together form Wide Area Measurement System (WAMS). With a high accuracy, PMU measure complex current and voltage values in the installation sites. Previously [1, 2] the possibility of using PMU measurements for determining automatic excitation controller (AEC) parameters of synchronous generator using optimization algorithms was shown. However, the searching for the best optimization method for this issue has not still finished. That is why it would be reasonable to research the capability of neural networks application. At present, we can see a great interest in artificial neural networks. They are implemented in many fields of human life.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-18
Application of Neural Network to Determine Parameters of the AEC of Synchronous Generator using Phasor Measurement Units
Nowadays, there is a large number of phasor measurement units (PMU) installed in the power systems, which together form Wide Area Measurement System (WAMS). With a high accuracy, PMU measure complex current and voltage values in the installation sites. Previously [1, 2] the possibility of using PMU measurements for determining automatic excitation controller (AEC) parameters of synchronous generator using optimization algorithms was shown. However, the searching for the best optimization method for this issue has not still finished. That is why it would be reasonable to research the capability of neural networks application. At present, we can see a great interest in artificial neural networks. They are implemented in many fields of human life.