Ana Ruiz-Delgado
Research Subjects
Ana Ruiz-Delgado has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Antonia Garrido Frenich
Research Group “Analytical Chemistry of Contaminants”, Department of Chemistry and Physics, Research Centre for Mediterranean Intensive Agrosystems and Agri-Food Biotechnology (CIAIMBITAL), University of Almeria, Agrifood Campus of International Excellence, ceiA3, E-04120 Almeria, Spain
2 shared publications - Roberto Romero-González
Research Group “Analytical Chemistry of Contaminants”, Department of Chemistry and Physics, Research Centre for Mediterranean Intensive Agrosystems and Agri-Food Biotechnology (CIAIMBITAL), University of Almeria, Agrifood Campus of International Excellence, ceiA3, E-04120 Almeria, Spain
2 shared publications - Rosalía López-Ruiz
Department of Chemistry-Physics, Analytical Chemistry of Contaminants, University of Almería, 04120 Almeria, Spain
2 shared publications S. Malato
Plataforma Solar de Almería-CIEMAT, Ctra Senés km 4.5, 04200 Tabernas (Almería), Spain; CIESOL, Joint Research Centre of the University of Almería-CIEMAT, 04120 Almería, Spain
2 shared publications- Sara Miralles-Cuevas
Laboratory for Environmental Research in Arid Zones, LIMZA, School of Mechanical Engineering, University of Tarapaca, Arica, Chile
2 shared publications A. Agüera
1 shared publication
Latest Publications
- 1 June 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 372, 129-136
EDDS as complexing agent for enhancing solar advanced oxidation processes in natural water: Effect of iron species and different oxidants
- 1 June 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 372, 129-136
EDDS as complexing agent for enhancing solar advanced oxidation processes in natural water: Effect of iron species and different oxidants
- 1 May 2019
- Published by Elsevier in Catalysis Today
- Vol. 328, 281-285
Natural chelating agents from olive mill wastewater to enable photo-Fenton-like reactions at natural pH
- 1 May 2019
- Published by Elsevier in Catalysis Today
- Vol. 328, 281-285
Natural chelating agents from olive mill wastewater to enable photo-Fenton-like reactions at natural pH
- 16 September 2016
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 33 (10) , 1535-1544
Headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry for the determination of haloanisoles in sparkling (cava and cider) and non-sparkling (wine) alcoholic beverages
A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R2 > 0.98) within the tested range (1–50 ng l−1). Recoveries were evaluated at three different levels (1, 5 and 50 ng l−1) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l−1, which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l−1.
- 16 September 2016
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 33 (10) , 1535-1544
Headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry for the determination of haloanisoles in sparkling (cava and cider) and non-sparkling (wine) alcoholic beverages
A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R2 > 0.98) within the tested range (1–50 ng l−1). Recoveries were evaluated at three different levels (1, 5 and 50 ng l−1) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l−1, which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l−1.
- 25 November 2015
- Published by Wiley in Journal of Separation Science
- Vol. 39 (3) , 528-536
Determination of polycyclic aromatic hydrocarbons in soy isoflavone nutraceutical products by gas chromatography coupled to triple quadrupole tandem mass spectrometry
Thirteen polycyclic aromatic hydrocarbons have been determined in soy‐based nutraceutical products. First, an optimization of extraction procedure was performed, and a solid–liquid extraction assisted by sonication and a dilute and shoot procedure were compared, selecting the dilute and shoot approach for the extraction of target compounds, utilizing a mixture of acetone/n‐hexane (1:1 v/v) as extractant solvent. After this, a clean‐up step was needed bearing in mind the complexity of these matrices. Dispersive solid‐phase extraction, using a mixture of C18 and Zr‐Sep+ (25 mg/mL each) was used. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. For quantification purposes, matrix‐matched calibration was used. The validation was applied at three concentration levels (20, 100 and 250 μg/kg), obtaining recoveries between 70 and 120% and precision values equal to or lower than 23%. Limits of detection and quantification were below 8 and 20 μg/kg, respectively. The method was applied in 11 samples, detecting five polycyclic aromatic hydrocarbons at concentrations ranging from 4.1 to 18.5 μg/kg.
- 25 November 2015
- Published by Wiley in Journal of Separation Science
- Vol. 39 (3) , 528-536
Determination of polycyclic aromatic hydrocarbons in soy isoflavone nutraceutical products by gas chromatography coupled to triple quadrupole tandem mass spectrometry
Thirteen polycyclic aromatic hydrocarbons have been determined in soy‐based nutraceutical products. First, an optimization of extraction procedure was performed, and a solid–liquid extraction assisted by sonication and a dilute and shoot procedure were compared, selecting the dilute and shoot approach for the extraction of target compounds, utilizing a mixture of acetone/n‐hexane (1:1 v/v) as extractant solvent. After this, a clean‐up step was needed bearing in mind the complexity of these matrices. Dispersive solid‐phase extraction, using a mixture of C18 and Zr‐Sep+ (25 mg/mL each) was used. The separation was achieved by gas chromatography and detection with triple quadrupole tandem mass spectrometry. For quantification purposes, matrix‐matched calibration was used. The validation was applied at three concentration levels (20, 100 and 250 μg/kg), obtaining recoveries between 70 and 120% and precision values equal to or lower than 23%. Limits of detection and quantification were below 8 and 20 μg/kg, respectively. The method was applied in 11 samples, detecting five polycyclic aromatic hydrocarbons at concentrations ranging from 4.1 to 18.5 μg/kg.