Chikako Cheong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chikako Cheong has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Tsutomu Miura
National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
8 shared publications Akiharu Hioki
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
3 shared publicationsToshihiro Suzuki
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
2 shared publicationsTsutomu Miura
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
2 shared publicationsYoshiyasu Yamauchi
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
2 shared publications- Akiharu Hioki
National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)
1 shared publication
Latest Publications
- 15 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (1) , 199-205
Study of the long-term stability conditions of cyanide ion standard solutions
Cyanide ions (CN − ) are highly toxic and pose significant environmental and health risks.
- 15 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (1) , 199-205
Study of the long-term stability conditions of cyanide ion standard solutions
Cyanide ions (CN − ) are highly toxic and pose significant environmental and health risks.
- Open Access
- 23 March 2025
- Published by Springer Nature
- p. 63-90
Certification of Reference Materials of Nutrients in Seawater, NMIJ CRM 7601-a, 7602-a, and 7603-a
The National Metrology Institute of Japan (NMIJ) has developed three levels of certified reference materials (CRMs) (NMIJ CRM 7601-a, 7602-a, and 7603-a) for nutrient analysis to provide SI traceability of analysis values of nutrients (nitrate, nitrite, phosphate, and dissolved silica) in oceanographic observations and to enable the comparison of these values across time and space. These property values were determined using the analytical results of multiple analytical methods and standard solutions of inorganic ions and elements as the SI traceability source. Depending on their characteristics, each property value was finally distinguished as a certified value, indicative value, or information. The homogeneity and long-term stability of the CRMs were evaluated on the basis of the International Organization for Standardization (ISO) Guide 35 using the results of continuous flow analysis. The certified values of nitrate and dissolved silica in 7603-a, from the deep Pacific Ocean, could be certified with uncertainties as low as approximately 1%, which is required for the observations. The values for nitrite and phosphate, as well as for relatively low nutrient concentrations, met the minimum requirements for the oceanographic observations, although the uncertainties were slightly higher. In terms of direct distribution from the National Research Institute of Metrology, these CRMs are the first CRMs in the world that can cover a wide nutrient concentration range from that of surface water to that of the deep Pacific Ocean. This development is expected to make the metrological accuracy of nutrient analyses in the observations more robust.
- 23 March 2025
- Published by Springer Nature
- p. 63-90
Open AccessCertification of Reference Materials of Nutrients in Seawater, NMIJ CRM 7601-a, 7602-a, and 7603-a
The National Metrology Institute of Japan (NMIJ) has developed three levels of certified reference materials (CRMs) (NMIJ CRM 7601-a, 7602-a, and 7603-a) for nutrient analysis to provide SI traceability of analysis values of nutrients (nitrate, nitrite, phosphate, and dissolved silica) in oceanographic observations and to enable the comparison of these values across time and space. These property values were determined using the analytical results of multiple analytical methods and standard solutions of inorganic ions and elements as the SI traceability source. Depending on their characteristics, each property value was finally distinguished as a certified value, indicative value, or information. The homogeneity and long-term stability of the CRMs were evaluated on the basis of the International Organization for Standardization (ISO) Guide 35 using the results of continuous flow analysis. The certified values of nitrate and dissolved silica in 7603-a, from the deep Pacific Ocean, could be certified with uncertainties as low as approximately 1%, which is required for the observations. The values for nitrite and phosphate, as well as for relatively low nutrient concentrations, met the minimum requirements for the oceanographic observations, although the uncertainties were slightly higher. In terms of direct distribution from the National Research Institute of Metrology, these CRMs are the first CRMs in the world that can cover a wide nutrient concentration range from that of surface water to that of the deep Pacific Ocean. This development is expected to make the metrological accuracy of nutrient analyses in the observations more robust.
- Open Access
- 23 March 2025
- Published by Springer Nature
- p. 91-106
Development of Primary Inorganic Standard Solution of Si, NMIJ CRM 3645-a
The need to develop Si standard solutions as national standards has been expanded, since the importance of Si measurement for evaluating industrial material and environmental analysis is increasing. For developing a Si standard solution, the purity assignment method for high-purity SiO2 using the gravimetric analysis and gravimetric preparation method for Si standard solution was established. Finally, an NMIJ CRM 3645-a Si standard solution was developed. Thirty-three elements in the high-purity SiO2 were measured for impurity evaluation. As a result, the amounts of impurities in SiO2 were low enough not to affect the analytical value obtained by the gravimetric analysis. The purity value of SiO2 was 99.648%. The relative standard deviation (RSD) of the mean value (RSD/√n) was considered the standard uncertainty in the gravimetric analysis, so the final purity value was 99.648% ± 0.074% (k = 2). The stability and homogeneity of the prepared Si standard solution were evaluated by inductively coupled plasma optical emission spectrometry and a continuous flow analyzer. Based on the variability and homogeneity, the standard uncertainties were 0.13% and 0.017%, respectively. Finally, the expanded uncertainty of NMIJ CRM 3645-a Si standard solution was 0.28%.
- 23 March 2025
- Published by Springer Nature
- p. 91-106
Open AccessDevelopment of Primary Inorganic Standard Solution of Si, NMIJ CRM 3645-a
The need to develop Si standard solutions as national standards has been expanded, since the importance of Si measurement for evaluating industrial material and environmental analysis is increasing. For developing a Si standard solution, the purity assignment method for high-purity SiO2 using the gravimetric analysis and gravimetric preparation method for Si standard solution was established. Finally, an NMIJ CRM 3645-a Si standard solution was developed. Thirty-three elements in the high-purity SiO2 were measured for impurity evaluation. As a result, the amounts of impurities in SiO2 were low enough not to affect the analytical value obtained by the gravimetric analysis. The purity value of SiO2 was 99.648%. The relative standard deviation (RSD) of the mean value (RSD/√n) was considered the standard uncertainty in the gravimetric analysis, so the final purity value was 99.648% ± 0.074% (k = 2). The stability and homogeneity of the prepared Si standard solution were evaluated by inductively coupled plasma optical emission spectrometry and a continuous flow analyzer. Based on the variability and homogeneity, the standard uncertainties were 0.13% and 0.017%, respectively. Finally, the expanded uncertainty of NMIJ CRM 3645-a Si standard solution was 0.28%.
- Open Access
- 23 March 2025
- Published by Springer Nature
- p. 107-115
Development of SI Traceable Si Standard Solution for Nutrient Analysis in Seawater
A certified reference material of SI-traceable silicon standard solution (KANSO-Si standard solution) was developed that can be supplied in large quantities to improve the measurement comparability of nutrient analysis in seawater. The high-purity SiO2 was selected as the starting material of the KANSO-Si. The high-purity SiO2 was fused by Na2CO3 in an electric furnace, followed by dissolution in pure water. The established procedure could be expanded to the production scale of 100 mL × 1000 bottles per lot at 1000 mg Si kg−1 mass fraction of Si. The value assignment of mass fraction of Si in manufactured KANSO-Si was performed by continuous flow analysis calibrated by NMIJ CRM 3645-a Si standard solution. The relative value of expanded uncertainty of the certified value of mass fraction of Si in the KANSO-Si standard solution was 0.4% (k = 2) including the standard uncertainties related to the homogeneity, long-term stability, and value assignment of mass fraction of Si.
- 23 March 2025
- Published by Springer Nature
- p. 107-115
Open AccessDevelopment of SI Traceable Si Standard Solution for Nutrient Analysis in Seawater
A certified reference material of SI-traceable silicon standard solution (KANSO-Si standard solution) was developed that can be supplied in large quantities to improve the measurement comparability of nutrient analysis in seawater. The high-purity SiO2 was selected as the starting material of the KANSO-Si. The high-purity SiO2 was fused by Na2CO3 in an electric furnace, followed by dissolution in pure water. The established procedure could be expanded to the production scale of 100 mL × 1000 bottles per lot at 1000 mg Si kg−1 mass fraction of Si. The value assignment of mass fraction of Si in manufactured KANSO-Si was performed by continuous flow analysis calibrated by NMIJ CRM 3645-a Si standard solution. The relative value of expanded uncertainty of the certified value of mass fraction of Si in the KANSO-Si standard solution was 0.4% (k = 2) including the standard uncertainties related to the homogeneity, long-term stability, and value assignment of mass fraction of Si.
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
CCQM-K161 "Anions in Seawater"
Main text: Anions or nutrients in seawater are very important targets for oceanographic research and environmental monitoring of contaminations. Quantification of minor and trace anions in seawater has always been a challenge for the extremely high salinity, disparate levels of analyte and matrix ions, and even need to be measured at levels close to the detection limits of the method performance. Evidence of successful participation in formal, relevant international comparisons is needed to support calibration and measurement capability claims (CMCs) made by the national metrology institutes (NMIs) and designated institutes (DIs). The CCQM-K161 Anions in Seawater was organized by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) to assess the abilities of the NMIs and DIs for the accurate determination of minor and trace anions in seawater. The measurands covered chloride (16 mg/g-25 mg/g), sulfate (1 mg/g-4 mg/g), bromide (30 mg/kg-100 mg/kg), nitrate (1 mg/kg-5 mg/kg) and phosphate (60 µg/kg-300 µg/kg). Twelve national metrology institutes and designated institutes participated in this key comparison. Participants were requested to evaluate the mass fractions, expressed in mg/g for chloride and sulfate, mg/kg for bromide and nitrate, and µg/kg for phosphate (as phosphorus) in a mixed natural seawater that was spiked with the phosphate. A variety of techniques including isotope dilution inductively coupled plasma mass spectrometry (IDMS), isotope dilution gas chromatography-mass spectrometry (ID-GC-MS), ion chromatography (IC), UV visible spectrophotometry (UV-Vis), flow injection analysis (FIA) was used by the participants for the determination. The NIST Decision Tree was used to assign the KCRV estimate and to calculate the degrees of equivalence of each participants following the IAWG Guidance on Using NIST Decision Tree for Comparison Reporting from 30 June 2023. Successful participation in CCQM-K161 demonstrates measurement capabilities for determination of anions in seawater. Considering the IAWG Core Capability Matrix, this material falls into the matrix challenge called 'High salts content', which corresponds to the CCQM amount-of-substance category sea water, and so will support CMCs for the anions in a mass fraction range from 60 µg/kg to 25 mg/g. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
CCQM-K161 "Anions in Seawater"
Main text: Anions or nutrients in seawater are very important targets for oceanographic research and environmental monitoring of contaminations. Quantification of minor and trace anions in seawater has always been a challenge for the extremely high salinity, disparate levels of analyte and matrix ions, and even need to be measured at levels close to the detection limits of the method performance. Evidence of successful participation in formal, relevant international comparisons is needed to support calibration and measurement capability claims (CMCs) made by the national metrology institutes (NMIs) and designated institutes (DIs). The CCQM-K161 Anions in Seawater was organized by the Inorganic Analysis Working Group (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) to assess the abilities of the NMIs and DIs for the accurate determination of minor and trace anions in seawater. The measurands covered chloride (16 mg/g-25 mg/g), sulfate (1 mg/g-4 mg/g), bromide (30 mg/kg-100 mg/kg), nitrate (1 mg/kg-5 mg/kg) and phosphate (60 µg/kg-300 µg/kg). Twelve national metrology institutes and designated institutes participated in this key comparison. Participants were requested to evaluate the mass fractions, expressed in mg/g for chloride and sulfate, mg/kg for bromide and nitrate, and µg/kg for phosphate (as phosphorus) in a mixed natural seawater that was spiked with the phosphate. A variety of techniques including isotope dilution inductively coupled plasma mass spectrometry (IDMS), isotope dilution gas chromatography-mass spectrometry (ID-GC-MS), ion chromatography (IC), UV visible spectrophotometry (UV-Vis), flow injection analysis (FIA) was used by the participants for the determination. The NIST Decision Tree was used to assign the KCRV estimate and to calculate the degrees of equivalence of each participants following the IAWG Guidance on Using NIST Decision Tree for Comparison Reporting from 30 June 2023. Successful participation in CCQM-K161 demonstrates measurement capabilities for determination of anions in seawater. Considering the IAWG Core Capability Matrix, this material falls into the matrix challenge called 'High salts content', which corresponds to the CCQM amount-of-substance category sea water, and so will support CMCs for the anions in a mass fraction range from 60 µg/kg to 25 mg/g. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Open Access
- 15 February 2023
- Published by Springer Nature in Research Square
Comparison of continuous flow analysis and ion chromatography for determinations of nitrate, nitrite and phosphate ions in seawater and development of related seawater certified reference materials
Determinations of three nutrients (nitrate, nitrite and phosphate ions) in seawater were investigated by continuous flow analysis (CFA) based on colorimetry and ion chromatography (IC). The accuracies of those methods were examined by discussing their uncertainties. While CFA is popular in this field, its comparison with IC was reported for the first time and contributed to an increase in the reliability of the analytical results. Finally, the investigation led to the development of three kinds of seawater certified reference materials (CRMs) of the National Metrology Institute of Japan (NMIJ) (NMIJ CRM 7601-a, 7602-a and 7603-a) for which the property values of nutrients including dissolved silica were given. The details of the development are described in the present paper.
- 15 February 2023
- Published by Springer Nature in Research Square
Open AccessComparison of continuous flow analysis and ion chromatography for determinations of nitrate, nitrite and phosphate ions in seawater and development of related seawater certified reference materials
Determinations of three nutrients (nitrate, nitrite and phosphate ions) in seawater were investigated by continuous flow analysis (CFA) based on colorimetry and ion chromatography (IC). The accuracies of those methods were examined by discussing their uncertainties. While CFA is popular in this field, its comparison with IC was reported for the first time and contributed to an increase in the reliability of the analytical results. Finally, the investigation led to the development of three kinds of seawater certified reference materials (CRMs) of the National Metrology Institute of Japan (NMIJ) (NMIJ CRM 7601-a, 7602-a and 7603-a) for which the property values of nutrients including dissolved silica were given. The details of the development are described in the present paper.
- Open Access
- 9 August 2021
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 19 (10) , 682-691
Determination of phosphate in seawater by ion chromatography inductively coupled plasma sector field mass spectrometry
Phosphate in three seawater certified reference materials developed in previous work (NMIJ CRM 7601‐a, 7602‐a, and 7603‐a) was not certified because it was only determined by continuous flow analysis (CFA). To obtain certified values for phosphate, we developed a novel method for the analysis of phosphate in seawater via inductively coupled plasma sector field mass spectrometry (ICP‐SFMS) combined with anion exchange ion chromatography (IC). With use of a Jet‐sampler cone and an X‐skimmer cone on the ICP‐SFMS instrument, the 31P sensitivity derived from phosphate was enhanced by a factor of 18 compared to that of standard cones. To reduce the severe saline‐generated matrix effect, an IC with a switching‐valve system that separates phosphate from saline was employed. By adding an internal standard element (As) to the seawater samples, time‐dependent fluctuation of the 31P sensitivity was corrected and a better calibration curve was obtained. The developed method was applied to the analysis of three types of seawater. Although NMIJ CRM 7601‐a could not be determined because its concentration after dilution for the IC separation is lower than the detection limit (0.005 μmol kg−1), the analytical results for NMIJ CRM 7602‐a and 7603‐a are in good agreement with the values obtained via CFA, considering their expanded uncertainties with the coverage factor of 2. The developed method was validated by analyzing an existing certified reference material (MOOS‐3). This method enabled the measurement of sub‐μmol kg−1 levels of phosphate with high accuracy and sensitivity.
- 9 August 2021
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 19 (10) , 682-691
Open AccessDetermination of phosphate in seawater by ion chromatography inductively coupled plasma sector field mass spectrometry
Phosphate in three seawater certified reference materials developed in previous work (NMIJ CRM 7601‐a, 7602‐a, and 7603‐a) was not certified because it was only determined by continuous flow analysis (CFA). To obtain certified values for phosphate, we developed a novel method for the analysis of phosphate in seawater via inductively coupled plasma sector field mass spectrometry (ICP‐SFMS) combined with anion exchange ion chromatography (IC). With use of a Jet‐sampler cone and an X‐skimmer cone on the ICP‐SFMS instrument, the 31P sensitivity derived from phosphate was enhanced by a factor of 18 compared to that of standard cones. To reduce the severe saline‐generated matrix effect, an IC with a switching‐valve system that separates phosphate from saline was employed. By adding an internal standard element (As) to the seawater samples, time‐dependent fluctuation of the 31P sensitivity was corrected and a better calibration curve was obtained. The developed method was applied to the analysis of three types of seawater. Although NMIJ CRM 7601‐a could not be determined because its concentration after dilution for the IC separation is lower than the detection limit (0.005 μmol kg−1), the analytical results for NMIJ CRM 7602‐a and 7603‐a are in good agreement with the values obtained via CFA, considering their expanded uncertainties with the coverage factor of 2. The developed method was validated by analyzing an existing certified reference material (MOOS‐3). This method enabled the measurement of sub‐μmol kg−1 levels of phosphate with high accuracy and sensitivity.
- Open Access
- 5 October 2020
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 69 (10.11) , 567-575
Stability of Metal and Non-metal Ion Standard Solutions
The stability of long-term storage was evaluated for 37 metal standard solutions and 12 non-metal ion standard solutions. A resin bottle or a glass bottle was used, depending on the kind of the standard solution. In addition, a case where the resin bottle was sealed in an aluminum-laminated plastic bag was also examined. The storage conditions were room-temperature storage and refrigerated storage. In the stability test, the solution mass in the bottle and the mass fraction of the target element or ions in the solution were monitored. Since the solution mass showed a decreasing tendency due to a evaporation of the solvent, the influence of the evaporation on the mass fraction of the target element or ions was evaluated based on the decrease rate of the solution mass. In addition, the stability of the target element or ions was evaluated by calculating the mass of the target element or ions in the standard solution as the product of the solution mass and the mass fraction of the target element or ions, and by estimating the dependence of the mass on the storage period. In consideration of these two evaluation results, the uncertainty of the long-term stability of the standard solution was evaluated.
- 5 October 2020
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 69 (10.11) , 567-575
Open AccessStability of Metal and Non-metal Ion Standard Solutions
The stability of long-term storage was evaluated for 37 metal standard solutions and 12 non-metal ion standard solutions. A resin bottle or a glass bottle was used, depending on the kind of the standard solution. In addition, a case where the resin bottle was sealed in an aluminum-laminated plastic bag was also examined. The storage conditions were room-temperature storage and refrigerated storage. In the stability test, the solution mass in the bottle and the mass fraction of the target element or ions in the solution were monitored. Since the solution mass showed a decreasing tendency due to a evaporation of the solvent, the influence of the evaporation on the mass fraction of the target element or ions was evaluated based on the decrease rate of the solution mass. In addition, the stability of the target element or ions was evaluated by calculating the mass of the target element or ions in the standard solution as the product of the solution mass and the mass fraction of the target element or ions, and by estimating the dependence of the mass on the storage period. In consideration of these two evaluation results, the uncertainty of the long-term stability of the standard solution was evaluated.
- Open Access
- 27 September 2019
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (2) , 247-251
Evaluation of the Calibration Method for Accurate Analysis of Dissolved Silica by Continuous Flow Analysis
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 27 September 2019
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (2) , 247-251
Open AccessEvaluation of the Calibration Method for Accurate Analysis of Dissolved Silica by Continuous Flow Analysis
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies