Agus Ulinuha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Agus Ulinuha has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Syed Islam
Federation University
8 shared publications M.A.S. Masoum
Department of Electrical and Computer Engineering, Curtin University of Technology, Perth, WA 6000, Australia
6 shared publicationsMohammad A. S. Masoum
Dept. of Electrical and Computer Engineering, Curtin University of Technology, Perth, W. A., Australia
2 shared publications- Abdul Rahman
Universitas Muhammadiyah Surakarta
1 shared publication - Aditya Saputra
University of Muhammadiyah Surakarta
1 shared publication - Agus Dwi Anggono
Mechanical Engineering Department, Universitas Muhammadiyah Surakarta (UMS), Jl. Ahmad Yani No. 157 Pabelan, Kartasura, Sukoharjo 57169, Jawa Tengah, Indonesia
1 shared publication
Latest Publications
- Open Access
- 22 March 2026
- Published by Cahaya Ilmu Cendekia in Integrated Science Education Journal
- Vol. 7 (2) , 360-369
Comparative Analysis of Sensor Reading Accuracy Between Arduino and ESP32 Microcontrollers for TDS Sensor Measurements
Purpose of the study: This study aims to compare the performance of Arduino UNO and ESP32 microcontrollers in TDS sensor measurements, evaluating reading accuracy, response speed, and reading stability to recommend the most suitable microcontroller platform for water quality monitoring applications. Methodology: Tools & Hardware: TDS sensor, Arduino UNO (ATmega328P, 10-bit ADC), ESP32 NodeMCU (12-bit ADC), TDS meter (reference instrument). Methods: Waterfall methodology, literature review, direct observation, potentiometer testing, and voltage measurement. Water samples tested at 101, 201, 300, 406, and 515 PPM concentrations, each with three repetitions at room temperature (~20–21°C). Main Findings: Arduino UNO achieved average voltage errors of 0.21%–2.12% across all TDS concentrations, compared to ESP32's 13.1%–54.32%. ESP32 misread 101 PPM as 48 PPM (54.32% error). Arduino UNO's standard deviation was 0.064 ADC versus ESP32's 2.019 ADC 31.5 times more variable confirming Arduino UNO's superior accuracy and stability for TDS sensor measurements. Novelty/Originality of this study: This Arduino UNO achieved average voltage errors of 0.21%–2.12% across all TDS concentrations, compared to ESP32's 13.1%–54.32%. ESP32 misread 101 PPM as 48 PPM (54.32% error). Arduino UNO's standard deviation was 0.064 ADC versus ESP32's 2.019 ADC — 31.5 times more variable confirming Arduino UNO's superior accuracy and stability for TDS sensor measurements.
- 22 March 2026
- Published by Cahaya Ilmu Cendekia in Integrated Science Education Journal
- Vol. 7 (2) , 360-369
Open AccessComparative Analysis of Sensor Reading Accuracy Between Arduino and ESP32 Microcontrollers for TDS Sensor Measurements
Purpose of the study: This study aims to compare the performance of Arduino UNO and ESP32 microcontrollers in TDS sensor measurements, evaluating reading accuracy, response speed, and reading stability to recommend the most suitable microcontroller platform for water quality monitoring applications. Methodology: Tools & Hardware: TDS sensor, Arduino UNO (ATmega328P, 10-bit ADC), ESP32 NodeMCU (12-bit ADC), TDS meter (reference instrument). Methods: Waterfall methodology, literature review, direct observation, potentiometer testing, and voltage measurement. Water samples tested at 101, 201, 300, 406, and 515 PPM concentrations, each with three repetitions at room temperature (~20–21°C). Main Findings: Arduino UNO achieved average voltage errors of 0.21%–2.12% across all TDS concentrations, compared to ESP32's 13.1%–54.32%. ESP32 misread 101 PPM as 48 PPM (54.32% error). Arduino UNO's standard deviation was 0.064 ADC versus ESP32's 2.019 ADC 31.5 times more variable confirming Arduino UNO's superior accuracy and stability for TDS sensor measurements. Novelty/Originality of this study: This Arduino UNO achieved average voltage errors of 0.21%–2.12% across all TDS concentrations, compared to ESP32's 13.1%–54.32%. ESP32 misread 101 PPM as 48 PPM (54.32% error). Arduino UNO's standard deviation was 0.064 ADC versus ESP32's 2.019 ADC — 31.5 times more variable confirming Arduino UNO's superior accuracy and stability for TDS sensor measurements.
- 25 September 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modeling, Simulation, and Scientific Computing
- Vol. 16 (05)
Torque combiner and rigid shaft simulation using Simscape
Torque combiners play a pivotal role in mechanical systems where multiple torque sources act in concert to drive a common load, such as in hybrid vehicles and multi-motor industrial equipment. This study proposes a simulation framework using Simscape, incorporating a distributed rotational mass-spring-damper shaft model that permits real-time inclusion of variable torque sources, inertial loads, and disturbances. Validation scenarios demonstrate the model’s ability to accurately handle system identification, proportional-integral (PI) control, and dynamic load sharing. Key results show that torque is effectively distributed across multiple motors, with steady-state torque loads of 45 [ ] divided equally among one, two, and three motors — each drawing 9.2, 4.7, and 3.2 A, respectively — leading to improved rebalancing times and peak efficiency of 90.9% in the two-motor scenario. The model maintains performance under fault conditions and dynamically engages spare actuators in adaptive actuation scenarios. These features affirm the framework’s robustness and its potential utility in the design and analysis of fault-tolerant, multi-source torque systems in mechanical engineering.
- 25 September 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modeling, Simulation, and Scientific Computing
- Vol. 16 (05)
Torque combiner and rigid shaft simulation using Simscape
Torque combiners play a pivotal role in mechanical systems where multiple torque sources act in concert to drive a common load, such as in hybrid vehicles and multi-motor industrial equipment. This study proposes a simulation framework using Simscape, incorporating a distributed rotational mass-spring-damper shaft model that permits real-time inclusion of variable torque sources, inertial loads, and disturbances. Validation scenarios demonstrate the model’s ability to accurately handle system identification, proportional-integral (PI) control, and dynamic load sharing. Key results show that torque is effectively distributed across multiple motors, with steady-state torque loads of 45 [ ] divided equally among one, two, and three motors — each drawing 9.2, 4.7, and 3.2 A, respectively — leading to improved rebalancing times and peak efficiency of 90.9% in the two-motor scenario. The model maintains performance under fault conditions and dynamically engages spare actuators in adaptive actuation scenarios. These features affirm the framework’s robustness and its potential utility in the design and analysis of fault-tolerant, multi-source torque systems in mechanical engineering.
- Open Access
- 30 May 2025
- Published by Cahaya Ilmu Cendekia in Integrated Science Education Journal
- Vol. 6 (2) , 85-96
Techno-economic Analysis of Investment and Operation of Photovoltaic Panels under a Load Sharing Scheme
Purpose of the study: This study aims to evaluate the techno-economic feasibility of the operational period of a 40 kWp on-grid Photovoltaic Panel with a load sharing scheme at Ella Skincare, focusing on technical analysis, investment and operational costs, and the potential for electricity cost savings. Methodology: This study used a quantitative method by analyzing energy consumption data and electricity bills over 6 months before and 6 months after installing the Photovoltaic Panel. The system used 60 Vertex TSM-DE21 panels and a Solis S5-GC50K inverter. The data were processed to calculate the Net Present Value (NPV), Return on Investment (ROI), Levelized Cost of Electricity (LCOE), and Payback Period (PP). Main Findings: The research results showed a 33.9% reduction in PLN electricity power consumption and more than 30% savings in electricity costs each month after the installation of the Photovoltaic Panel. Although the NPV had not yet exceeded the initial investment, the ROI reached 13.64% in the first year, indicating significant financial potential in the long term. Novelty/Originality of this Research: This study provides empirical evidence on the effectiveness of the load sharing scheme in improving efficiency and reducing operational electricity costs in the commercial sector. This study offers new insights into the investment feasibility of Photovoltaic Panels in Indonesia, particularly in the context of utilizing renewable energy to reduce dependence on conventional energy sources.
- 30 May 2025
- Published by Cahaya Ilmu Cendekia in Integrated Science Education Journal
- Vol. 6 (2) , 85-96
Open AccessTechno-economic Analysis of Investment and Operation of Photovoltaic Panels under a Load Sharing Scheme
Purpose of the study: This study aims to evaluate the techno-economic feasibility of the operational period of a 40 kWp on-grid Photovoltaic Panel with a load sharing scheme at Ella Skincare, focusing on technical analysis, investment and operational costs, and the potential for electricity cost savings. Methodology: This study used a quantitative method by analyzing energy consumption data and electricity bills over 6 months before and 6 months after installing the Photovoltaic Panel. The system used 60 Vertex TSM-DE21 panels and a Solis S5-GC50K inverter. The data were processed to calculate the Net Present Value (NPV), Return on Investment (ROI), Levelized Cost of Electricity (LCOE), and Payback Period (PP). Main Findings: The research results showed a 33.9% reduction in PLN electricity power consumption and more than 30% savings in electricity costs each month after the installation of the Photovoltaic Panel. Although the NPV had not yet exceeded the initial investment, the ROI reached 13.64% in the first year, indicating significant financial potential in the long term. Novelty/Originality of this Research: This study provides empirical evidence on the effectiveness of the load sharing scheme in improving efficiency and reducing operational electricity costs in the commercial sector. This study offers new insights into the investment feasibility of Photovoltaic Panels in Indonesia, particularly in the context of utilizing renewable energy to reduce dependence on conventional energy sources.
- Open Access
- 21 April 2025
- Published by Tanjungpura University in ELKHA
- Vol. 17 (1) , 77-83
Harmonic Distortion Analysis Of On-grid Photovoltaic Panel Integration In Load Sharing Scheme
Harmonic analysis is crucial to maintain the system power quality, especially in photovoltaic panels with load sharing scheme. Previous studies have discussed the impact of harmonic distortion on electric power systems in general, but there is still limited discussion on on-grid photovoltaic panel systems without the load-sharing scheme. Harmonic is a distortion phenomenon of current and voltage that is higher than fundamental frequency. The consumption of nonlinear loads contributes to the rising of harmonic distortion that has a bad impact on the system's power quality. This study aims to analyze and compare the levels of harmonic distortion on on-grid photovoltaic panels with a load-sharing scheme and evaluate the suitability with the IEEE 519-2014 standard. The result of this study shows that the Total Harmonic Distortion (THD) on the current (THDi) in PLN’s load and network exceeds the limit that is stipulated in IEEE 519-2014. THD current in PLN’s loads and network is higher than the output current from the on-grid inverter because of the consumption of the nonlinear load. Meanwhile, Total Harmonic Distortion (THD) on the voltage (THDv) in the on-grid inverter, electric network, and load tends to be lower and still within the safe limit. This study is expected to support the implementation of an effective preventive strategy to reduce harmonic distortion on the performance of on-grid photovoltaic panels that will be optimum in the load-sharing scheme.
- 21 April 2025
- Published by Tanjungpura University in ELKHA
- Vol. 17 (1) , 77-83
Open AccessHarmonic Distortion Analysis Of On-grid Photovoltaic Panel Integration In Load Sharing Scheme
Harmonic analysis is crucial to maintain the system power quality, especially in photovoltaic panels with load sharing scheme. Previous studies have discussed the impact of harmonic distortion on electric power systems in general, but there is still limited discussion on on-grid photovoltaic panel systems without the load-sharing scheme. Harmonic is a distortion phenomenon of current and voltage that is higher than fundamental frequency. The consumption of nonlinear loads contributes to the rising of harmonic distortion that has a bad impact on the system's power quality. This study aims to analyze and compare the levels of harmonic distortion on on-grid photovoltaic panels with a load-sharing scheme and evaluate the suitability with the IEEE 519-2014 standard. The result of this study shows that the Total Harmonic Distortion (THD) on the current (THDi) in PLN’s load and network exceeds the limit that is stipulated in IEEE 519-2014. THD current in PLN’s loads and network is higher than the output current from the on-grid inverter because of the consumption of the nonlinear load. Meanwhile, Total Harmonic Distortion (THD) on the voltage (THDv) in the on-grid inverter, electric network, and load tends to be lower and still within the safe limit. This study is expected to support the implementation of an effective preventive strategy to reduce harmonic distortion on the performance of on-grid photovoltaic panels that will be optimum in the load-sharing scheme.
- Open Access
- 1 March 2022
- Published by Adam Mickiewicz University Poznan in Quaestiones Geographicae
- Vol. 41 (1) , 147-169
Non-Medical risk assessment of COVID-19 in parts of Central and East Java, Indonesia
The impact of the Coronavirus disease 2019 (COVID-19) pandemic varies as each country has a different capacity to stop the virus transmission and apply social distancing. A densely populated country, such as Indonesia, tends to face challenges in implementing social distancing due to population characteristics. The Indonesian government focuses on the medical aspect as this virus is new and has been deadly with a high transmission rate. Meanwhile, the non-medical risk during the pandemic is still unclear. The main objective of this study is to assess the non-medical risk at the village level in two agglomeration cities of Central Java: Greater Surakarta and Surabaya. The methodologies use a risk index, derived from the risk reduction concept. The hazard refers to the death toll, while the vulnerability relates to parameters such as disaster, social and public facilities, health facilities, economics and demography. Further, the parameters were weighted based on expert judgement derived using analytical hierarchy process (AHP). The study found that the disaster aspect had the highest weight (0.38), followed by health facilities (0.31), economics (0.17), social-public facilities (0.11) and demography (0.04). The standard deviations of those parameters were relatively low, between 0.12 and 0.25. A low vulnerability index (0.05–0.36) was observed to be dominant in both study areas. There are 11 villages in Greater Surakarta and 30 villages in Greater Surabaya with high vulnerability index. Disaster-prone areas, low economic growth, lack of health facilities and aged demographic structure significantly added to this vulnerability. Further, a high-risk index (0.67–1.00) is observed in three villages in Greater Surabaya and one village in Greater Surakarta. These villages are relatively close to the city centre and have good accessibility. Furthermore, these four villages experienced the severest impact of the pandemic because the furniture and tourism sectors were their primary industries.
- 1 March 2022
- Published by Adam Mickiewicz University Poznan in Quaestiones Geographicae
- Vol. 41 (1) , 147-169
Open AccessNon-Medical risk assessment of COVID-19 in parts of Central and East Java, Indonesia
The impact of the Coronavirus disease 2019 (COVID-19) pandemic varies as each country has a different capacity to stop the virus transmission and apply social distancing. A densely populated country, such as Indonesia, tends to face challenges in implementing social distancing due to population characteristics. The Indonesian government focuses on the medical aspect as this virus is new and has been deadly with a high transmission rate. Meanwhile, the non-medical risk during the pandemic is still unclear. The main objective of this study is to assess the non-medical risk at the village level in two agglomeration cities of Central Java: Greater Surakarta and Surabaya. The methodologies use a risk index, derived from the risk reduction concept. The hazard refers to the death toll, while the vulnerability relates to parameters such as disaster, social and public facilities, health facilities, economics and demography. Further, the parameters were weighted based on expert judgement derived using analytical hierarchy process (AHP). The study found that the disaster aspect had the highest weight (0.38), followed by health facilities (0.31), economics (0.17), social-public facilities (0.11) and demography (0.04). The standard deviations of those parameters were relatively low, between 0.12 and 0.25. A low vulnerability index (0.05–0.36) was observed to be dominant in both study areas. There are 11 villages in Greater Surakarta and 30 villages in Greater Surabaya with high vulnerability index. Disaster-prone areas, low economic growth, lack of health facilities and aged demographic structure significantly added to this vulnerability. Further, a high-risk index (0.67–1.00) is observed in three villages in Greater Surabaya and one village in Greater Surakarta. These villages are relatively close to the city centre and have good accessibility. Furthermore, these four villages experienced the severest impact of the pandemic because the furniture and tourism sectors were their primary industries.
- Open Access
- 1 April 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1858 (1) , 012055
Solar Photovoltaic Application for Contributing Power Supply of Community Clean Water Provider
The need of clean water for human daily life is about crucial. Due to the inadequate capability of government water supply company, it is becoming common for a community to establish their own water supply system. This includes a deep well, high water reservoir, and submersible pump. The pump is normally supplied with power from electricity grid. The extensive availability of sunlight may be used to generate electric power using Solar Photovoltaic (PV) panels for supplying power for the pump. This paper presents the application of Solar PV panels to generate power that contributes power for the pump at the system of clean water provider. A 1000-WP solar panels system is employed to generate the voltage and a 60-A MPPT is used to regulate the voltage for supplying 2 x 150-Ah Li-ion battery. A 3000-W inverter is used to provide AC power for 3-hp 220-V pump. Considering the capacity of Solar PV panels and the continued availability of sunlight, the hybrid supply for the pump is established. This integrates the supply from solar PV and utility grid controlled with Automatic Transfer Switch (ATS). This determines the power supply for the pump either from Solar PV or electricity grid. This system is implemented in the community water supply at Sidomulyo, Krikilan, Sragen. The hybrid strategy enables solar PV to contribute supplying power for the pump and reduce the need of power from utility.
- 1 April 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1858 (1) , 012055
Open AccessSolar Photovoltaic Application for Contributing Power Supply of Community Clean Water Provider
The need of clean water for human daily life is about crucial. Due to the inadequate capability of government water supply company, it is becoming common for a community to establish their own water supply system. This includes a deep well, high water reservoir, and submersible pump. The pump is normally supplied with power from electricity grid. The extensive availability of sunlight may be used to generate electric power using Solar Photovoltaic (PV) panels for supplying power for the pump. This paper presents the application of Solar PV panels to generate power that contributes power for the pump at the system of clean water provider. A 1000-WP solar panels system is employed to generate the voltage and a 60-A MPPT is used to regulate the voltage for supplying 2 x 150-Ah Li-ion battery. A 3000-W inverter is used to provide AC power for 3-hp 220-V pump. Considering the capacity of Solar PV panels and the continued availability of sunlight, the hybrid supply for the pump is established. This integrates the supply from solar PV and utility grid controlled with Automatic Transfer Switch (ATS). This determines the power supply for the pump either from Solar PV or electricity grid. This system is implemented in the community water supply at Sidomulyo, Krikilan, Sragen. The hybrid strategy enables solar PV to contribute supplying power for the pump and reduce the need of power from utility.
- Open Access
- 25 May 2020
- Published by The World Academy of Research in Science and Engineering in International Journal of Emerging Trends in Engineering Research
- Vol. 8 (5) , 1886-1891
A Hybrid Photovoltaic-Wind Electricity Generation for Street Lighting
- 25 May 2020
- Published by The World Academy of Research in Science and Engineering in International Journal of Emerging Trends in Engineering Research
- Vol. 8 (5) , 1886-1891
Open AccessA Hybrid Photovoltaic-Wind Electricity Generation for Street Lighting
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 503-508
The impact of harmonic filter locations on distortion suppression
The extensive and ever increasing application of nonlinear loads has introduced a distortion in power system voltage. The nonlinear v-i relation of the devices leads to the existence of higher frequency components of voltage/current causing system voltage no longer sinusoidal. The higher frequency components of current may be blocked using proper harmonic filters. However the location of filters should be carefully decided. Since the distorted currents may inject and flow over the system the assessment of filter locations is necessary to find the best locations. The impact of filter locations on harmonic suppression is evaluated using harmonic flow analysis. For this purposes, a Decoupled Harmonic Power Flow (DHPF) is developed and used in this study. The proposed scheme is implemented on a 30-bus distribution system to investigate the relation between filter locations and distortion mitigation.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 503-508
The impact of harmonic filter locations on distortion suppression
The extensive and ever increasing application of nonlinear loads has introduced a distortion in power system voltage. The nonlinear v-i relation of the devices leads to the existence of higher frequency components of voltage/current causing system voltage no longer sinusoidal. The higher frequency components of current may be blocked using proper harmonic filters. However the location of filters should be carefully decided. Since the distorted currents may inject and flow over the system the assessment of filter locations is necessary to find the best locations. The impact of filter locations on harmonic suppression is evaluated using harmonic flow analysis. For this purposes, a Decoupled Harmonic Power Flow (DHPF) is developed and used in this study. The proposed scheme is implemented on a 30-bus distribution system to investigate the relation between filter locations and distortion mitigation.
- 31 October 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 660, 846-850
Enhancement of Electrical Distribution System Operation Using Intelligent Optimization Techniques Considering Unbalanced Condition
The enhancement of distribution system operation is proposed in this paper by optimally controlling the installed switchable devices. The objective of the control is to simultaneously minimize system losses and improve system voltage profile. This objective may be achieved by optimally dispatching the controllable components (shunt capacitor and Load Tap Changer/LTC) taking into account system unbalanced. A Genetic Algorithm (GA) is developed to determine the load curve partition useful for effective LTC scheduling and switching constraint satisfaction. GA is also assigned to determine the hourly status of shunt capacitor switching and LTC tap position. For power flow analyses under unbalanced conditions, Forward/Backward Propagation Algorithm is developed and employed. The strategy is implemented on the IEEE 34-bus unbalanced distribution system and the resulted improvement is analyzed. The main contribution is inclusion of unbalanced system conditions into optimization problem.
- 31 October 2014
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 660, 846-850
Enhancement of Electrical Distribution System Operation Using Intelligent Optimization Techniques Considering Unbalanced Condition
The enhancement of distribution system operation is proposed in this paper by optimally controlling the installed switchable devices. The objective of the control is to simultaneously minimize system losses and improve system voltage profile. This objective may be achieved by optimally dispatching the controllable components (shunt capacitor and Load Tap Changer/LTC) taking into account system unbalanced. A Genetic Algorithm (GA) is developed to determine the load curve partition useful for effective LTC scheduling and switching constraint satisfaction. GA is also assigned to determine the hourly status of shunt capacitor switching and LTC tap position. For power flow analyses under unbalanced conditions, Forward/Backward Propagation Algorithm is developed and employed. The strategy is implemented on the IEEE 34-bus unbalanced distribution system and the resulted improvement is analyzed. The main contribution is inclusion of unbalanced system conditions into optimization problem.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Reactive Power/Voltage control for unbalanced distribution system using genetic algorithms
The unbalanced conditions are taken into account in the Reactive Power/Voltage control of distribution system. The aim of the control is to simultaneously minimize energy loss and improve voltage profile. The control is carried out by optimal dispatch of load tap changers (LTC) and shunt capacitors considering unbalanced conditions. A genetic algorithm (GA) is developed to determine the load curve partition for effective LTC scheduling and switching constraint satisfaction. GA is also appointed to determine the optimal dispatch schedule of the devices and to check the fulfillment of switching constraints prior to performing calculations. For power flow analyses under unbalanced conditions, a forward/backward propagation algorithm is developed. The optimization is implemented on the IEEE 34-bus unbalanced distribution system, and the presented system improvements are highlighted. The main contribution is inclusion of unbalanced system conditions into the optimal dispatch problem considering different daily load curves for the three phases of distribution system.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Reactive Power/Voltage control for unbalanced distribution system using genetic algorithms
The unbalanced conditions are taken into account in the Reactive Power/Voltage control of distribution system. The aim of the control is to simultaneously minimize energy loss and improve voltage profile. The control is carried out by optimal dispatch of load tap changers (LTC) and shunt capacitors considering unbalanced conditions. A genetic algorithm (GA) is developed to determine the load curve partition for effective LTC scheduling and switching constraint satisfaction. GA is also appointed to determine the optimal dispatch schedule of the devices and to check the fulfillment of switching constraints prior to performing calculations. For power flow analyses under unbalanced conditions, a forward/backward propagation algorithm is developed. The optimization is implemented on the IEEE 34-bus unbalanced distribution system, and the presented system improvements are highlighted. The main contribution is inclusion of unbalanced system conditions into the optimal dispatch problem considering different daily load curves for the three phases of distribution system.