IPIben Bach Pedersen

Iben Bach Pedersen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iben Bach Pedersen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Corneal decompensation after PreserFlo Microshunt surgery

    by Iben Bach Damgaard, Anders Ivarsen, Jesper Hjortdal, Daniella Bach‐Holm, Niklas Telinius


  • Intrastromal Lenticule Rotation for Treatment of Astigmatism Up to 10.00 Diopters Ex Vivo in Human Corneas

    by Iben Bach Damgaard, Anders Ivarsen, Jesper Hjortdal

    PURPOSE: To evaluate the feasibility of intrastromal lenticule rotation (ISLR) as a novel technique for management of astigmatism up to 10.00 diopters (D). METHODS: Eighteen human donor corneas were mounted on an artificial anterior chamber. After laser application and dissection, the lenticule was rotated 90° in the intrastromal pocket. Scheimpflug tomography (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) was acquired preoperatively and following ISLR. The attempted astigmatic correction was twice the cylindrical magnitude of the lenticule referenced to the corneal plane: 4.80 D (5.00 D group, n = 9) and 9.32 D (10.00 D group, n = 9), respectively. The change in keratometric astigmatism was evaluated by vector analysis. RESULTS: In the 5.00 D group, ISLR caused a mean absolute surgical induced astigmatism (SIA) of 5.30 ± 1.14 D with a correction index (CI) of 1.14 ± 0.25 and an angle of error (AoE) of −0.80° ± 4.61°. In the 10.00 D group, the SIA averaged 9.57 ± 1.10 D with a CI of 1.03 ± 0.12 and an AoE of 2.75° ± 3.60°. The average total corneal refractive power (TCRP) increased 1.36 ± 0.67 and 1.95 ± 1.57 D in the 5.00 D and 10.00 D groups, respectively. Postoperative optical coherence tomography revealed stromal redistribution in the periphery of the optical zone with tissue addition in the preoperative steep meridian and tissue reduction in the preoperative flat meridian. CONCLUSIONS: ISLR seemed feasible and precise for management of regular astigmatism up to 10.00 D ex vivo in human donor corneas. A myopic shift was observed in TCRP. The in vivo corneal remodeling after ISLR warrants investigation. [ J Refract Surg. 2019;35(7):451–458.]


  • Open Access

    Review of Corneal Biomechanical Properties Following LASIK and SMILE for Myopia and Myopic Astigmatism

    by Iben Bach Damgaard, Mohamed Reffat, Jesper Hjortdal

    Worldwide, femtosecond Laser AssistedIn-situKeratomileusis (LASIK) is a well known and commonly used refractive technique, although Small Incision Lenticule Extraction (SMILE) has become increasingly popular since it was introduced in 2011. In LASIK, a corneal flap is cut with a microkeratome or femtosecond laser, followed by thinning of the stromal bed with excimer laser ablation. In SMILE, a minor intrastromal lenticule is cut with a femtosecond laser and subsequently removed through a small incision, leaving the anterior and strongest part of the cornea almost intact. Both LASIK and SMILE require cutting of corneal lamellae that may reduce the biomechanical stability of the cornea, with the potential risk of corneal iatrogenic ectasia as a severe complication. However, SMILE preserves the anterior corneal integrity and may, in theory, better preserve the corneal biomechanical strength than LASIK after surgery.A review aimed to examine the current literature that describes and compares the corneal biomechanical properties after Laser AssistedIn-situKeratomileusis (LASIK) and Small Incision Lenticule Extraction (SMILE). A comprehensive search was performed in Pubmed.gov using the following search queries: Corneal biomechanical properties, corneal biomechanics, ocular response analyser, ocular response analyzer, ORA,ex vivo, in vitro, Corvis, Corvis ST, LASIK, and SMILE.


  • Biological Lenticule Implantation for Correction of Hyperopia: An Ex Vivo Study in Human Corneas

    by Iben Bach Damgaard, Anders Ivarsen, Jesper Hjortdal

    PURPOSE: To evaluate changes in corneal tomography after stromal lenticule implantation ex vivo, with respect to the dependency of the lenticule thickness and implantation depth on the corneal curvature and the postoperative biomechanical strength at increased chamber pressure.METHODS: Twenty-eight human donor corneas underwent pocket implantation of refractive stromal lenticules. Four groups were created by the combination of two implantation depths (110 and 160µm) and two lenticule thicknesses (95µm = 4.00 diopters [D], 150µm = 8.00 D). Sagittal keratometry and total corneal refractive power (TCRP4mm,apex,zone) were obtained for the front and back curvature with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) at chamber pressures of 15 and 40 mm Hg.RESULTS: The anterior curvature steepening was comparable between the 4.00 D and 8.00 D groups (P> .141), but more pronounced with 110µm implantation depth (P< .038). The posterior curvature flattened significantly more after implantation of 8.00 D than 4.00 D lenticules (P< .002), but was similar at 110 and 160µm implantation depths (P> .071). Average ΔTCRP for the 4.00 D and 8.00 D groups was 3.10 ± 0.60 and 5.30 ± 1.66 diopters (D) at 110-µm depth, respectively (P= .003), but 1.99 ± 0.79 and 3.36 ± 1.45 D at 160-µm depth, respectively (P= .066). The relative correction achieved was 66% to 78% at 110-µm depth and 42% to 50% at 160-µm depth, but similar when using 4.00 D and 8.00 D lenticules. Increased chamber pressure caused significant anterior and posterior curvature steepening after implantation in all four groups (P< .001), but not before implantation (P> .632).CONCLUSIONS: The power of the implanted lenticule must be higher than the intended correction, and customized to the chosen implantation depth. Biomechanical strength seems to decrease after lenticule implantation.[J Refract Surg.2018;34(4):245–252.]


  • Open Access

    Refractive Correction and Biomechanical Strength Following SMILE With a 110- or 160-μm Cap Thickness, Evaluated Ex Vivo by Inflation Test

    by Iben Bach Damgaard, Anders Ivarsen, Jesper Hjortdal

    Purpose: To examine the refractive correction and corneal biomechanical strength after small incision lenticule extraction (SMILE) by using a 110- or 160-μm cap thickness. Methods: Thirty-two human donor corneas were allocated into 4 groups, combining one of two cap thicknesses (110 and 160 μm) with one of two spherical corrections (−4 D and −8 D). Each cornea was mounted on an artificial anterior chamber. The chamber pressure was adjusted by an attached 8% dextran media column. The anterior and posterior sagittal 3-mm-diameter curvature (rsag3mm) and the total corneal refractive power (TCRP4mm,apex,zone) were obtained before and after SMILE at a chamber pressure of 15 or 40 mm Hg. The average changes after surgery (Δ = postoperative − preoperative) and at increased chamber pressure (δ = 40 mm Hg − 15 mm Hg) were compared. Results: A 110-μm cap thickness caused more anterior flattening (Δr15,−8D, 1.02 ± 0.08 mm versus 0.60 ± 0.17 mm), less posterior steepening (Δr15,−8D, −0.19 ± 0.11 mm versus −0.45 ± 0.20 mm), and more myopic correction (ΔTCRP15,−8D, −6.30 ± 0.96 D versus −4.55 ± 1.66 D) than a 160-μm cap thickness for −8 D SMILE (P < 0.034), but not for −4 D SMILE (ΔTCRP15,−4D,110μm, −3.86 ± 1.31 D versus ΔTCRP15,−4D,160μm, −3.57 ± 1.27 D, P = 0.718). After SMILE, increased chamber pressure caused anterior steepening (P < 0.014), which was similar at cap thicknesses of 110 and 160 μm (δr−4D, −0.13 ± 0.14 mm versus −0.09 ± 0.05mm, P = 0.431). Conclusions: For high myopic corrections, a 160-μm cap caused less anterior curvature flattening and more posterior steepening than a 110-μm cap, and consequently less myopic correction. The inflation test revealed a reduction in the biomechanical strength after SMILE; this was similar when using a 110- or 160-μm cap thickness.


  • Contralateral Eye Comparison of SMILE and Flap-Based Corneal Refractive Surgery: Computational Analysis of Biomechanical Impact

    by Ibrahim Seven, Ali Vahdati, Iben Bach Pedersen, Anders Vestergaard, Jesper Hjortdal, Cynthia J. Roberts, William J. Dupps

    PURPOSE: Computational analyses were performed to quantify and directly compare the biomechanical impact of flapless and flap-based procedures in a series of patients undergoing small incision lenticule extraction (SMILE) in one eye and flap-based femtosecond lenticule extraction in the other.METHODS: Tomographic data from 10 eyes of 5 patients undergoing femtosecond laser refractive lenticule extraction for myopic astigmatism with or without a stromal flap (femtosecond lenticule extraction in one eye, SMILE in the contralateral eye) were used to generate computational models. Inverse finite element analyses were performed at physiologic intraocular pressure followed by forward analyses at elevated intraocular pressure to assess corneal displacement and stress under differential loading. Case-specific treatment settings were incorporated. Preoperative material constants were obtained through inverse finite element analyses, and the surgically induced change in fiber stiffness within each flap was determined by minimization of the error between the simulated and actual 6-month topographic outcomes.RESULTS: Flap-based procedures produced a 49% (range: 2% to 87%) greater mean reduction in effective stromal collagen fiber stiffness within the flap region than contralateral SMILE cases. Lower stresses and deformations were observed within the residual stromal bed in SMILE cases than in flap-based cases. Stromal bed displacements and stresses were more affected by a loading increase in flap-based eyes than flapless eyes.CONCLUSIONS: Intrastromal flapless procedures had less impact on anterior stromal collagen mechanics and resulted in lower stromal bed displacements and stresses than flap-based procedures in contralateral eyes. However, biomechanical impact varied widely between individuals and this reinforces the need for individualized assessment of ectasia risk.[J Refract Surg.2017;33(7):444–453].


  • Changes in Astigmatism, Densitometry, and Aberrations After SMILE for Low to High Myopic Astigmatism: A 12-Month Prospective Study

    by Iben Bach Pedersen, Anders Ivarsen, Jesper Hjortdal

    PURPOSE: To evaluate 12-month changes in refraction, visual outcome, corneal densitometry, and postoperative aberrations after small incision lenticule extraction (SMILE) for myopic astigmatism. METHODS: This 12-month prospective clinical trial comprised 101 eyes (101 patients) treated with SMILE for myopic astigmatism with cylinder of 0.75 to 4.00 diopters (D). The preoperative, 1-week, and 1-, 3-, 6-, 9-, and 12-month examinations included measurement of manifest refraction, uncorrected distance visual acuity (UDVA), and corrected (CDVA) distance visual acuity. Astigmatic error vector analysis was performed using Al-pin's method. Densitometry and aberrations were evaluated with Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany). RESULTS: Preoperative spherical equivalent averaged −6.78 ± 1.90 D with 1.81 ± 1.00 D in cylinder correction. After 12 months, 74% and 93% of the eyes were within ±0.50 and ±1.00 D of the attempted refraction, respectively. The logMAR UDVA and CDVA averaged 0.03 ± 0.16 and −0.08 ± 0.09, respectively. Vector analysis showed a with-the-rule undercorrection at 12 months with a mean difference vector of 0.31 D @ 91°. There was a minor counterclockwise rotation of the axis, with an arithmetic angle of error of 0.34° ± 14°. An undercorrection of approximately 11% per diopter of attempted correction was seen at 12 months. Spherical aberrations, coma, and higher order aberrations remained stable during the postoperative period ( P < .09). After 12 months, no increase in densitometry could be identified. CONCLUSIONS: Treatment of astigmatism with SMILE seems to be predictable and effective, but with an astigmatic undercorrection of approximately 11% and a small counterclockwise rotation of the axis. [ J Refract Surg. 2017;33(1):11–17.]


  • Three-Year Results of Small Incision Lenticule Extraction for High Myopia: Refractive Outcomes and Aberrations

    by Iben Bach Pedersen, Anders Ivarsen, Jesper Hjortdal

    PURPOSE: To assess the 3-year refractive and visual outcomes after small incision lenticule extraction (SMILE) in patients with high myopia and to evaluate the optical changes from 3 months to 3 years after surgery. METHODS: A total of 87 eyes (87 patients) undergoing SMILE for high myopia were included. Preoperative and 3-month and 3-year postoperative follow-up examinations included manifest refraction and uncorrected and corrected distance visual acuities. Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) was used to evaluate the total corneal refractive power and the root mean square of spherical aberration, coma, and total higher-order aberrations. The paired t test and Wilcoxon signed rank test were used. RESULTS: The preoperative spherical equivalent averaged −7.30 ± 1.40 diopters (D); no significant changes occurred between 3 months and 3 years after surgery (−0.30 ± 0.50 vs −0.40 ± 0.60 D, P = .071). Uncorrected distance visual acuity was stable from 3 months to 3 years after SMILE (0.04 ± 0.17 vs 0.03 ± 0.19 logMAR; P = .28), whereas corrected distance visual acuity improved from −0.05 ± 0.15 to −0.08 ± 0.11 logMAR ( P < .001). At 3 months, 82% and 93% of eyes were within ±0.50 and ±1.00 D, respectively. At 3 years, 78% and 90% were within ±1.00 D of the attempted refraction, respectively. Spherical and higher-order aberrations significantly decreased from 3 months to 3 years, whereas coma remained stable. A significant regression of 0.36 ± 0.29 D was seen in total corneal refractive power ( P < .001). CONCLUSIONS: The refractive and visual outcomes seemed stable years after SMILE. A minor myopic regression was observed in total corneal refractive power but not in subjective refraction. There seems to be a significant long-term improvement in higher-order aberrations after surgery. [ J Refract Surg. 2015;31(11):719–724.]


  • Repeatability, Reproducibility, and Age Dependency of Dynamic Scheimpflug-Based Pneumotonometer and Its Correlation With a Dynamic Bidirectional Pneumotonometry Device

    by Sashia Bak-Nielsen, Iben Bach Pedersen, Anders Ivarsen, Jesper Hjortdal

    To assess the repeatability, reproducibility, and age dependency of dynamic Scheimpflug-based pneumotonometry (Corvis)-generated parameters and their correlation with dynamic bidirectional pneumotonometry device [Ocular Response Analyzer (ORA)] measurements [corneal hysteresis (CH) and corneal resistance factor (CRF)]. Eyes of 29 healthy participants between 20 and 30 years old were measured using Corvis and ORA. Measurements were performed twice in a row and repeated after 1 week. Repeatability and reproducibility were examined by calculating intraday and interday coefficients of variation (CVs). Corvis measurements were compared with measurements from 19 participants older than 65 years. The most repeatable and reproducible Corvis-generated parameters, with intraday and interday CVs < 10% were as follows: intraocular pressure (IOP), pachymetry, time to first and second applanation (A1 time, A2 time), radius and amplitude at highest concavity (HC radius and HC deformation amplitude, respectively), time to highest concavity (HC time), deflection length and amplitude at highest concavity [HC deflection length and HC deflection amplitude (millimeter), respectively], and time to highest deflection amplitude [HC deflection amplitude (millisecond)]. However, 7 of 19 analyzed parameters showed CVs > 10%. HC-related parameters showed significant age dependency. The correlation between Corvis and ORA was weak (A2 time and CH, r = 0.36, A1 time and CRF, r = 0.41). Corvis-derived IOP was on average 2.2 ± 2.3 mm Hg higher than cornea-compensated IOP, with large differences in patients with high-average IOP. The considerable variation in repeatability and reproducibility should be taken into account when using the Corvis. Corvis parameters showed poor correlation with CH and CRF obtained by ORA measurements.


  • Open Access

    Graft rejection and failure following endothelial keratoplasty (DSAEK) and penetrating keratoplasty for secondary endothelial failure

    by Iben B. Pedersen, Anders Ivarsen, Jesper Hjortdal

    Purpose: To compare the frequency of rejection and graft failure after Descemet's stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) for secondary endothelial failure.Methods: Seventy‐eight eyes undergoing DSAEK from 2006 to 2013 and 80 eyes undergoing PK from 1998 to 2013 were included. Indications were endothelial failure due to pseudophakic bullous keratopathy (82%), previous eye trauma (8%), uveitis (4%) or other causes (6%). Rejection episodes and graft failure were recorded, together with preoperative risk factors (glaucoma, neovascularization and active inflammation). Kaplan–Meier survival curves with up to 4 years follow‐up were used to compare DSAEK with PK, as well as low‐risk with high‐risk eyes.Results: During follow‐up, 15% of the PK‐treated eyes and 4% of the DSAEK‐treated eyes experienced rejection. Graft failure occurred in 8% of the PK‐treated eyes and in 7% of the DSAEK‐treated eyes. No significant differences were found in the rate of rejection (p = 0.11), graft failure (p = 0.29) or rejection‐related graft failure (p = 0.30) between DSAEK and PK in low‐risk eyes. In DSAEK, high‐risk eyes (mainly with glaucoma) experienced significantly more rejection episodes (p = 0.01), graft failures (p = 0.04) and rejection‐related graft failures (p = 0.04) compared with low‐risk eyes. No differences were seen between high‐risk and low‐risk PK‐treated eyes (p > 0.40).Conclusion: In the present, relatively small study, no differences in rejection rate or graft failure were found between DSAEK and PK in low‐risk eyes. However, glaucoma seems to increase the risk of graft complications after DSAEK for secondary endothelial failure. Long‐term studies of larger samples sizes are needed to confirm this.