SPSeung‐Hyun Park

Seung‐Hyun Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seung‐Hyun Park has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of Flap Management and Membrane Fixation on Augmented Ridge Dimensions in Guided Bone Regeneration: A Preclinical In Vivo Study

    by Jung‐Yoon Kim, Seung Ha Yoo, Betül Hwang, Seung‐Hyun Park, Jin‐Young Park, Jung‐Seok Lee

    Objectives: To investigate the main effects of flap management and membrane fixation and their interaction on augmented ridge dimensions 12 weeks after guided bone regeneration (GBR) in chronic noncontained defects. Materials and Methods: Implants were placed into chronic noncontained defects in six male dogs using a split‐mouth 2 × 2 factorial design ( n = 6 sites per condition). Buccal defects were augmented with particulate bone substitute and resorbable collagen membranes and assigned to four groups based on the stabilization strategy: retentive flap (limited periosteal release) with or without membrane fixation (Ret‐F, Ret‐UF) and extensive flap release with or without membrane fixation (Ex‐F, Ex‐UF). Augmented ridge dimensions and tissue composition were assessed using micro‐computed tomography and histomorphometric analyses at 12 weeks. Results: Flap × fixation interactions were identified for micro‐CT augmented ridge area ( p = 0.015) and volume ( p = 0.005) and for several histomorphometric outcomes. A flap main effect occurred only at 5‐mm augmented tissue width ( p = 0.033). Micro‐CT volume was greater for Ret‐UF than for Ex‐UF (difference, 106.70 mm 3 ; p = 0.029) and for Ex‐F than for Ex‐UF (114.65 mm 3 ; p = 0.021). Micro‐CT area was greater for Ex‐F than for Ex‐UF (8.072 mm 2 ; p = 0.042), and tissue width at 5 mm was greater for Ret‐UF than for Ex‐UF (2.442 mm; p = 0.015). Conclusion: In this exploratory study, flap management and membrane fixation had context‐dependent associations with augmented dimensions. Limited release without fixation and extensive release with fixation showed greater dimensions than extensive release without fixation in selected comparisons.

  • Microbial Network Signatures Associated With Outcomes of Peri‐Implantitis Therapy

    by Seung‐Hyun Park, Da‐Mi Kim, Seulbin Im, Eduardo H. de Souza Oliveira, Ignacio Sanz‐Martin, Ignacio Sanz‐Sanchez, Jan Derks, Magda Feres, Jae‐Kook Cha

    Aim: To investigate the microbial network signatures associated with outcomes following surgical therapy of peri‐implantitis. Materials and Methods: Microbiological data from a 1‐year randomised controlled trial of 28 patients (28 implants) were analysed. Based on a composite outcome (probing depth ≤ 5 mm, minimal bleeding on probing and no further marginal bone loss) at 1 year, implant sites were categorised into a successful ( n = 10) or a non‐successful group ( n = 18). Peri‐implant crevicular fluid was collected at baseline and at 3, 6 and 12 months and analysed using 16S rRNA gene sequencing. Results: A significant compositional shift from baseline to 1 year was observed in the successful group ( p = 0.001), with a significant increase in Rothia aeria ( p = 0.048), Haemophilus parainfluenzae ( p = 0.033) and Neisseria oralis ( p = 0.025) over time. Network analysis revealed that the successful group exhibited a Porphyromonas gingivalis ‐associated module enriched with high‐centrality commensals at baseline, and significantly greater network edge density ( p = 0.005) and connectivity ( p = 0.018) at 1 year. Spearman correlation analyses at 1 year identified significant negative correlations between P. gingivalis and commensals including H. parainfluenzae , Streptococcus species and Veillonella undefined ( p < 0.05). Conclusion: In this exploratory secondary analysis of a small cohort, favourable outcomes of peri‐implantitis therapy were associated with increased microbial network connectivity and commensal centrality. Trial Registration: Korean Clinical Research Information Service number KCT0007900

  • Efficacy of Local Application of a Combined Metronidazole and Minocycline Ointment in the Non‐Surgical Treatment of Peri‐Implantitis: A Preclinical In Vivo Study

    by Jin‐Young Park, Seung‐Hyun Park, Chang‐Sung Kim

    Aim: To evaluate the adjunctive effect of locally delivered metronidazole–minocycline (Met/Mc) versus minocycline (Mc) ointment and mechanical debridement alone in non‐surgical treatment of peri‐implantitis. Materials and Methods: Peri‐implantitis was induced through ligature in a canine model. Implants were allocated to mechanical debridement (control), Mc or Met/Mc. Probing depth (PD), bleeding on probing (BOP), marginal bone levels (MBLs) and immunohistochemical parameters (CD3, CD20, IgG) were assessed over 12 weeks. Results: Both Met/Mc and Mc showed significantly greater PD reductions than control (Δ −5.33 ± 1.35 mm and −3.67 ± 1.89 mm vs. −0.04 ± 1.80 mm; p < 0.0001 and p = 0.0004). BOP and MBL reductions were significantly greater in Met/Mc than Mc and control (BOP: Δ −5.67 ± 0.71 vs. −3.22 ± 2.54 vs. −0.78 ± 1.99, p = 0.020; MBL: Δ −2.41 ± 1.21 vs. −0.80 ± 0.21 vs. +0.64 ± 0.93 mm, p = 0.0035). Met/Mc showed significantly lower CD3, CD20 and IgG than the control and lower CD20 and IgG than Mc (all p < 0.05). Conclusion: In this preclinical model, adjunctive Met/Mc ointment yielded greater clinical and radiographic improvements than both comparators, accompanied by reduced B‐cell and plasma‐cell infiltration. These findings provide preclinical proof of concept, however, warranting clinical confirmation.

  • Open Access

    Dimensional Changes of the Peri‐Implant Mucosa Applying a Suture‐Free Wound Closure Using a Healing Abutment Attachment: A Randomised Controlled Clinical Trial

    by Seulbin Im, Young Woo Song, Seung‐Hyun Park, Jin‐Young Park, Daniel S. Thoma, Ronald E. Jung, Jae‐Kook Cha, Ui‐Won Jung

    Aim: To compare peri‐implant soft‐tissue dimensional changes following wound closure using a suture‐free healing abutment attachment (HAA) compared to conventional suturing during implant surgery. Materials and Methods: Thirty patients who were randomly allocated to the HAA group (15 patients, 20 implants) or the suture group (15 patients, 15 implants) were analysed. Clinical parameters including keratinised tissue width (KTW), buccal supracrestal tissue height (STH) and surgery time (seconds) were recorded at posterior maxillary and mandibular implant sites during surgery and over a 6‐month follow‐up period. Results: The HAA group demonstrated significantly less decrease in KTW compared to the suture group (−0.46 ± 0.71 mm vs. −1.23 ± 0.95 mm at implant level, p < 0.05). The extent of STH increase over 6 months was numerically higher in the HAA group than in the suture group (0.95 ± 0.47 vs. 0.59 ± 0.67 mm), and the difference was statistically significant ( p < 0.05). The time required for flap stabilisation was significantly shorter in the HAA group (43.73 s vs. 198.27 s, p < 0.001). Conclusion: Applying the suture‐free HAA was more time‐efficient and could reduce buccal keratinised tissue shrinkage compared to the traditional wound closure by suturing.

  • Open Access

    Clinical Efficacy of Narrow‐Diameter Tissue‐Level Implants for Molar Replacement: A 1‐Year Randomised Controlled Trial

    by Hyun‐Woo Park, Seung Ha Yoo, Seung‐Hyun Park, Jae‐Kook Cha, Ui‐Won Jung, Mariano Sanz

    Aim: To compare 1‐year clinical and radiographic outcomes of narrow‐ versus wide‐diameter tissue‐level implants for single molar replacement. Materials and Methods: This two‐arm randomised controlled trial enrolled 20 patients (23 implants) in one sextant. Participants received either 3.5‐mm narrow‐diameter implants (NDI, n = 12) or 5.0‐mm wide‐diameter implants (WDI, n = 11) using a tissue‐level design with computer‐guided surgery. The primary outcome was marginal bone loss (MBL) at 1 year assessed by periapical radiographs. Secondary outcomes included operation time, pre‐allocation analysis of augmentation requirement, clinical peri‐implant parameters, hard‐ and soft‐tissue dimensions, mucosal recession and buccal soft‐tissue contour and implant stability. Non‐inferiority margin for MBL was 0.5 mm. Results: All 23 implants achieved 100% survival. Mean MBL was 0.39 ± 0.29 mm for NDI and 0.48 ± 0.31 mm for WDI (upper 95% confidence interval [CI]: 0.176 mm), confirming non‐inferiority of NDI. Operation time was shorter in this cohort for NDI (20.3 ± 9.3 min) than WDI (28.8 ± 15.3 min; one‐sided p = 0.049). Peri‐implant clinical parameters were comparable. Conclusions: NDI showed non‐inferiority to WDI in MBL at 1 year while reducing operative time, supporting NDIs as a viable and efficacious alternative for anatomically restricted posterior sites. Trial Registration: Korean ClinicalResearch Information Service Number: KCT00094155

  • Open Access

    Horizontal Ridge Augmentation Using an rhBMP ‐2 Loaded Volume‐Stable Collagen Matrix Compared to Guided Bone Regeneration: A Preclinical In Vivo Study

    by Jin‐Young Park, Gi‐Seo Song, Seung‐Hyun Park, Lorenzo Tavelli, David T. Wu, Daniel S. Thoma, Ronald E. Jung, Ui‐Won Jung, Jae‐Kook Cha

    Aim: To investigate whether incorporation of recombinant human bone morphogenetic protein‐2 (rhBMP‐2) into a volume‐stable collagen matrix (VCMX) enhances horizontal ridge augmentation compared with VCMX alone or guided bone regeneration (GBR). Methods: Chronic horizontal ridge defects were created in five canines. Sites randomly received: (1) control, (2) VCMX, (3) VCMX with rhBMP‐2 or (4) GBR (deproteinised bovine bone mineral with a collagen membrane). After 8 weeks, outcomes were assessed by profilometry, micro‐computed tomography and histomorphometry. Results: VCMX/rhBMP‐2 showed significantly greater new bone volume (181.50 ± 142.32 mm 3 ) than GBR (36.06 ± 25.86), VCMX (8.40 ± 6.15) and control (7.32 ± 4.03 mm 3 ) (all p < 0.05). Histometric new bone thickness was greater in VCMX/rhBMP‐2 than GBR at all levels (crestal: 2.31 ± 1.93 vs. 1.09 ± 0.41 mm; p = 0.038). Coronal contour gain was higher in VCMX/rhBMP‐2 than VCMX ( p = 0.007), with no difference versus GBR ( p = 0.654). At middle and apical levels, all augmentation groups exceeded control ( p ≤ 0.011). Conclusions: RhBMP‐2 delivered via VCMX enhanced horizontal bone regeneration with augmented dimensions comparable to GBR.

  • Open Access

    Resorption Pattern and Bone Regeneration Using a Synthetic Bone Substitute Block With or Without rhBMP ‐2 and Bisphosphonates: An in Vivo Experiment

    by Seung Ha Yoo, Young Woo Song, Seung‐Hyun Park, Jae‐Hong Lim, Ronald Jung, Daniel Thoma, Ui‐Won Jung

    This study aimed to investigate whether recombinant human bone morphogenetic protein‐2 (rhBMP‐2) or bisphosphonate added to synthetic block bone substitute influences new bone formation and grafting material degradation patterns. In a rabbit calvarial model, four critical‐size bone defects were created and treated with a saline‐soaked synthetic bone block (SBB group), bisphosphonate‐soaked synthetic bone block (BPS group), rhBMP‐2‐soaked synthetic bone block (BMP group), or left untreated as control (control group). At 8 weeks, synchrotron‐based micro‐computed tomography (micro‐CT) and histological analyses were performed. All outcomes were evaluated separately in intrabony areas, embedded within the native bone, and extrabony areas, extending beyond the bone surface. Synchrotron‐based micro‐CT analysis revealed limited resorption of the synthetic bone block across all groups, as the mean percentages of synthetic bone block resorption of the SBB group, BPS group, and BMP group were 8.56%, 11.13%, and 9.11%, respectively, with no significant differences. The cylindric morphology of the grafts was preserved even in the exophytic extrabony portion. Histological evaluation showed that BMP significantly enhanced new bone formation, particularly in the intrabony area (2.65 mm 2 for SBB group, 1.37 mm 2 for BPS group, and 4.41 mm 2 for BMP group in mean). Despite these differences in osteogenic activity, neither bisphosphonate nor rhBMP‐2 markedly increased graft resorption, as residual bone graft material was well preserved. Synthetic bone blocks could provide volume stability in both intrabony and extrabony regions, regardless of the addition of bioactive mediators. RhBMP‐2 enhanced bone regeneration, though.

  • Open Access

    Immediate Loading on Tapered Versus Straight Multiple Implants: A 3‐Year Follow‐Up of a Randomized Clinical Trial

    by Young Woo Song, Seung‐Hyun Park, Franz J. Strauss, Sung Jin Yoo, Jin‐Young Park, Jae‐Kook Cha, Ui‐Won Jung

    Objective: To evaluate the clinical and radiographic outcomes at 3 years following immediate loading of tapered implants (TI) versus straight implants (SI) from a randomized controlled trial (RCT). Materials and Methods: Of the 41 patients who received 93 implants in the original RCT (TI group: 23 patients, 50 implants; SI group: 18 patients, 43 implants), those who completed 3‐year follow‐up were included in this analysis. Implant survival and success rates, as well as changes in marginal bone loss (MBL), were assessed and compared using Kaplan–Meier curves, Cox proportional hazards models, and linear mixed‐effects models. Results: A total of 28 patients with 61 implants were evaluated (TI group: 15 patients, 32 implants; SI group: 13 patients, 29 implants). At 3 years post‐immediate loading, cumulative survival rates at the patient level were 95.8% for the TI group and 78.3% for the SI group (intergroup p = 0.109). At the implant level, survival rates were 96.2% for TI and 90.0% for SI (intergroup p = 0.351). All implant failures occurred within the first year (1 implant in TI; 5 implants in SI), and no further losses were recorded thereafter. However, two TI implants in a single patient exhibited progressive peri‐implantitis during follow‐up. Mean MBL values were 0.61 ± 1.70 mm for the TI group and 0.53 ± 0.53 mm for the SI group, with no statistically significant differences between groups (intergroup p = 0.428). Conclusion: It could be cautiously concluded that the TI rather than the SI might be a more predictable option in terms of achieving an optimized initial stability for immediate loading in the posterior region. Once osseointegration was successfully achieved, however, the macro‐design of the implant might not have an influence on the clinical and radiographic outcomes including the osseointegrated state during the 3 years of observational period. Trail Registration: KCT0002489; https://cris.nih.go.kr/cris/search/detailSearch.do?search_lang=E&focus=reset_12&search_page=L&pageSize=10&page=undefined&seq=19032&status=5&seq_group=8332


  • Open Access

    Thread Depth Effects on Stability and Positional Accuracy in Guided Immediate Implants: A Randomized Controlled Trial

    by Na‐Yoon Kwon, Ji‐Young Jung, Kyung‐A Ko, Seung‐Hyun Park, Franz Josef Strauss, Jung‐Seok Lee

    Objectives: To evaluate the influence of implant thread depth on implant stability and positional accuracy in fully guided immediate implant placement. Materials and Methods: Fifty‐four patients received a reference tapered (BLT), a standard‐thread (MST), or a deep‐thread implant (MDT). Fifty‐four implants were placed using fully guided surgery and evaluated over 1‐year follow‐up. Primary outcomes were implant stability (insertion torque, ISQ, ISV). Secondary outcomes included positional accuracy and marginal bone level (MBL) at 12 months. Results: Primary and longitudinal stability were comparable across groups. Insertion torque was highest for MDT implants, followed by MST and BLT implants (BLT: 35.28 ± 11.18; MST: 40.00 ± 11.88; MDT: 43.89 ± 10.92 Ncm; p = 0.062). A higher proportion of MDT implants achieved insertion torque ≥ 40 Ncm (MDT: 14/18; MST: 12/18; BLT: 8/18). Angular deviation differed among implant groups (MDT: 5.57° ± 3.71°; BLT: 4.73° ± 2.46°; MST: 3.58° ± 1.81°; p = 0.062). In subgroup analysis comparing implants differing only in thread depth (MST vs. MDT), angular deviation was significantly greater for MDT ( p = 0.029), particularly in molar sites. At 12 months, MBL did not differ significantly among groups. Conclusions: In fully guided immediate implant placement, deeper‐thread implants showed higher insertion torque values but were associated with greater angular deviation, while longitudinal stability and marginal bone levels remained comparable. Deeper‐thread designs may be beneficial when enhanced primary stability is required, provided careful angulation control is ensured. Trial Registration: cris.nih.go.kr Identifier: KCT0009402; This clinical trial was not registered prior to participant recruitment and randomization


  • Top Cited Papers
    Open Access

    Patient‐ and Clinician‐Reported Outcomes and Outcome Measures for Edentulous Maxilla Rehabilitated With Implant‐Assisted Overdentures: A Systematic Review

    by Jin‐Young Park, Seung‐Hyun Park, Sofya Sadilina, Ronald E. Jung, Daniel S. Thoma, Franz J. Strauss, Ui‐Won Jung

    Aim: To identify patient‐ and clinician‐reported outcomes (PROs and ClinROs) and methods of assessment in clinical trials involving short and/or standard‐length and/or zygomatic implants supporting maxillary implant overdentures (IODs). Materials and Methods: A systematic search was conducted in PubMed, EMBASE, Scopus, Web of Science CENTRAL, and National clinical trial register for articles published between January 1, 2014, and March 23, 2024. Studies that included PROs and ClinROs for implant therapy in patients with edentulous maxillae were eligible, and study quality was appraised using the Cochrane Risk of Bias 2 tool, Newcastle‐Ottawa Scale, or Joanna Briggs Institute Critical tool. Results: A total of 2331 articles were screened, resulting in 21 studies representing 14 patient cohorts with 462 participants and 2140 implants. Two studies used short implants (6 mm) with standard‐length implants, while the remaining 19 studies focused exclusively on standard‐length implants (7–14 mm); none included zygomatic implants. Patient‐reported outcome measures (PROMs) varied widely: Oral Health Impact Profile questionnaires and visual analogue scales were each used in eight studies, and eleven studies relied on unstandardized questionnaires. Implant survival rate was the most frequently used ClinRO, included in all but one study. Subjective ClinROs based on clinician perception were absent in all studies. Conclusions: Although PROMs were frequently employed in clinical trials, the lack of standardization hinders meaningful comparisons across studies. While objective ClinROs were commonly reported, subjective ClinROs reflecting clinicians' perceptions were notably absent.