SPSatish Patel

Satish Patel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Satish Patel has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Dharmendrasinh A. Baria

    A. R. College of Pharmacy and G. H. Patel Institute of Pharmacy

    2 shared publications
  • Natubhai J Patel

    Shree S.K. Patel College of Pharmaceutical Education and Research, Department of Pharmaceutical Chemistry, Ganpat Vidyanagar, Kherva, Mehsana-382711, Gujarat, India

    2 shared publications
  • Paresh U Patel

    Shree S.K. Patel College of Pharmaceutical Education and Research, Department of Pharmaceutical Chemistry, Ganpat Vidyanagar, Kherva, Mehsana-382711, Gujarat, India

    2 shared publications
  • Arun M Prajapati

    Shree S.K. Patel College of Pharmaceutical Education and Research, Department of Pharmaceutical Chemistry, Ganpat Vidyanagar, Kherva, Mehsana-382711, Gujarat, India

    1 shared publication
  • Arun Prajapati

    1 shared publication
  • Bhoomi Patel

    Shree S. K. Patel College of Pharmaceutical Education and Research Ganpat University Mehsana India

    1 shared publication

Latest Publications

  • Chromatographic separation to determine doxycycline monohydrate and ornidazole

    by Bhoomi Patel, Satish Patel

    High‐performance thin‐layer chromatography offers a variety of benefits that may assist you to save time and money, notably the capacity to run multiple samples at once and its reduced solvent usage. In alignment with the needs of molecular chemistry, it was also employed to modify and derivatize the stationary phase. Using a precise, accurate, as well as affordable high‐performance thin‐layer chromatography approach, the simultaneous measurement method for Doxycycline monohydrate and Ornidazole in the formulation has been developed and validated. Methanol: Iso‐propyl alcohol: Triethylamine (8:1.5:0.5, v/v/v) was used as the mobile phase during the separation, which took place on a stationary phase of pre‐treated derivatized silica gel aluminum plate 60 F 254 . At 285 nm, separated components were densitometrically measured. The method was validated for Linearity and range, precision, reproducibility, accuracy, the limit of detection, the limit of quantification, and robustness as per the International Council for Harmonization Q 2 (R 1 ) guideline. Doxycycline monohydrate and Ornidazole regression coefficients (R2) were found to be 0.9967 and 0.9964, accordingly. Doxycycline monohydrate and Ornidazole percentage recoveries were measured to be 99.74 ± 0.65 and 100.8 ± 1.17, respectively. The analytical findings demonstrate that the proposed approach could be used to quantify Doxycycline monohydrate and Ornidazole simultaneously in pharmaceutical formulation.


  • SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF PHENYLEPHRINE HYDROCHLORIDE AND NAPHAZOLINE HYDROCHLORIDE IN EYE DROPS BY CHEMOMETRIC TECHNIQUES AND ARTIFICIAL NEURAL NETWORK

    by Satish A. Patel, Dharmendrasinh A. Baria

    Three multivariate calibration-prediction techniques, partial least squares (PLS), principal component regression (PCR) and artifi cial neural networks (ANN), have been applied without separation in the spectrophotometric multi-component analysis of phenylephrine hydrochloride and naphazoline hydrochloride. A set of 25 synthetic mixtures of phenylephrine hydrochloride and naphazoline hydrochloride has been evaluated to determine the predictability of PLS, PCR and ANN. The absorbance data matrix was obtained by measuring zero-order absorbances between 230-300 nm at intervals of 3 nm. The suitability of the models was determined on the basis of root mean square error (RMSE), root mean squared cross validation error (RMSECV) and root mean squared prediction error (RMSEP) values of calibration and validation data. The results showed a very good correlation between true values and the predicted concentration values. Therefore, the methods developed can be used for routine drug analysis without chemical pre-treatment.


  • DEVELOPMENT AND VALIDATION OF UV SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS ESTIMATION OF NAPHAZOLINE HCL AND PHENYLEPHRINE HCL IN EYE DROPS

    by Satish A Patel, Dharmendrasinh A Baria

    A first order derivative UV-spectrophotometric method was developed to quantify naphazoline hydrochloride and phenylephrine hydrochloride in eye drops. Naphazoline hydrochloride and phenylephrine hydrochloride were estimated at 275.6nm (zero crossover point of phenylephrine hydrochloride) and 289.4nm (zero crossover point of naphazoline hydrochloride), respectively. The method was found to be linear in the concentration range of 10 - 25 µg/ml for naphazoline hydrochloride and 20 - 60 µg/ml for phenylephrine hydrochloride. The developed method was subjected to validation in accordance with ICH guidelines Q2(R1) for different validation parameters. The analytical method developed was found to be accurate and cost - effective and can be used for routine analysis of naphazoline hydrochloride and phenylephrine hydrochloride in eye drops.


  • Open Access

    Development and Validation of Column High-Performance Liquid Chromatographic and Derivative Spectrophotometric Methods for Determination of Levofloxacin and Ornidazole in Combined Dosage Forms

    by Satish A Patel, Arun M Prajapati, Paresh U Patel, Natubhai J Patel, Jayesh B Vaghmasi

    The manuscript describes validated reversed-phase column high-performance liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of levofloxacin (LFX) and ornidazole (ORNI) in combined dosage forms. The RP-HPLC separation was achieved on a Phenomenex C18 column (250 mm 4.6 mm id, 5 m) using KH2PO4 buffer (pH 6.8)methanolacetonitrile (70 + 15 + 15, v/v/v) mobile phase at a flow rate of 1.5 mL/min and ambient temperature (25 2C). Quantification was achieved with photodiode array detection at 295 nm over the concentration range of 110 g/mL for both LFX and ORNI, with mean recovery of 101.7 0.23 and 99.23 1.57, respectively, by the RP-HPLC method. The derivative spectrophotometric method was based on the determination of both the drugs at their respective zero crossing point (ZCP). The first-order derivative spectra were obtained at N =1 (scaling factor), = 2.0 nm (wavelength interval), and the determinations were made at 310 nm (ZCP of ORNI) for LFX and 295 nm (ZCP of LFX) for ORNI over the concentration range of 240 g/mL for both LFX and ORNI. Mean recovery was 99.46 0.96 and 100.9 0.72, respectively, by the first-derivative UV spectrophotometric method. Standard and sample solutions were prepared with methanol as the solvent in both of the methods. These methods were found to be simple, accurate, precise, and sensitive and were applicable for the simultaneous determination of LFX and ORNI in combined dosage forms.


    • 25 October 2007
      • Vol. 90  (5) , 1272-7

    Determination of linezolid in pharmaceutical dosage forms by liquid chromatography and ultraviolet spectroscopy.

    by Satish Patel, Paresh U Patel, Natubhai J Patel, Madhabhai M Patel, Urvisha V Bangoriya

    A liquid chromatographic (LC) method and a UV spectrophotometric method were developed and validated for quantitative determination of linezolid in tablets and injection. The isocratic LC analyses were performed on an RP18 column using a mobile phase composed of methanol-water-acetonitrile (40 + 40 + 20, v/v/v) at a flow rate of 1.0 mL/min. The UV spectrophotometric method was performed at 251 nm. The analytical methods were validated according to International Conference on Harmonization guidelines. The calibration graphs were linear (correlation coefficient > 0.999) in the studied concentration ranges of 0.1 to 10 microg/mL for LC and 2 to 16 microg/mL for UV spectrophotometry. The relative standard deviation values for intraday and interday precision studies were 98% for both methods. The specificity of the LC method was proved using forced degradation. Statistical analysis showed no significant difference between the results obtained by the 2 methods. The proposed methods are precise and accurate and can be applied directly to the oral and parenteral pharmaceutical preparations of linezolid.