AHAriel J. Hannum

Ariel J. Hannum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ariel J. Hannum has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stim‐ CODE : PNS and CNS Constraint Optimized Diffusion‐Encoding for Neuroimaging on 200 mT /m Whole‐Body Gradients

    by Ariel J. Hannum, Michael Loecher, Qingping Chen, Eric Arbes, Kawin Setsompop, Maxim Zaitsev, Daniel B. Ennis

    Purpose: Ultra‐high‐performance whole‐body MRI gradients ( 200mT/m, 200 T/m/s) can reduce echo times (TE) in diffusion‐weighted imaging (DWI), improving SNR. However, full hardware utilization is limited by cardiac (CNS) and peripheral (PNS) nerve stimulation thresholds. This work demonstrates Stimulation Constraint Optimized diffusion‐encoding (Stim‐CODE) for neuro diffusion. Methods: Stim‐CODE uses the gradient optimization (GrOpt) toolbox to optimally design diffusion‐encoding gradient waveforms subject to a CNS or PNS “constraint envelope” based on other gradient events in the sequence. Stim‐CODE was evaluated in simulations and in vivo protocols with in‐plane resolutions of 1.5 1.5 mm and 1.0 1.0 mm across G = [45, 80, 200] mT/m and T/m/s. Healthy volunteers ( N = 10) underwent neuro DWI at b = 1000 s/mm with Monopolar, Stim‐CODE‐, Bipolar, and Stim‐CODE‐ encoding. SNR, apparent diffusion coefficient (ADC) maps, and ADC uncertainty were quantified. One volunteer underwent DTI with the same encoding schemes acquired at = [1000, 3000]s/mm. Results: Stim‐CODE reduced TEs across all ‐values, with larger gains for higher resolutions, greater G, and ‐nulled waveforms. Phantom and in vivo experiments confirmed equivalent diffusion‐weighting with TE savings and SNR improvements. Stim‐CODE‐ had significant SNR gains over Bipolar scans, but some differences in global ADC were observed. DTI metrics were similar across scans, with Stim‐CODE showing lower uncertainty. Conclusion: Stim‐CODE maximizes hardware capabilities to achieve time‐optimized diffusion‐encoding while respecting CNS and PNS, enabling similar diffusion‐weighting as conventional approaches with reduced TE and higher SNR.

  • Open Access

    Comparative Performance Analysis of an Open Source Motion‐Compensated Cardiac Diffusion Sequence Across Different MRI Systems and Gradient Strengths—A Pilot Study

    by Eric Arbes, Ariel Hannum, Johannes Fischer, Qingping Chen, Sebastian Littin, Alexander Maier, Michael Bock, Simon Reiss

    Purpose: To validate the performance of an open‐source cardiac diffusion sequence framework and to investigate hardware‐based performance differences. Methods: Three second order motion compensated sequence files were compiled using Pulseq and applied across different MRI systems to image five volunteers. DTI and SNR analysis was performed to investigate protocol efficacy. Results: The sequences performed well at the task of imaging short axis views of the myocardium and producing data suitable for diffusion tensor imaging analysis. Significant differences in sequence performance across different systems and within the same system were revealed. Relative SNR utilizing the strongest available gradient system yielded up to 80% more SNR than the weakest tested system. Relative SNR obtained from the same sequence at different scanners differed by up to 42%, suggesting hardware impacts that warrant further investigation. Conclusion: The presented sequence framework allows for an easy starting point into cardiac diffusion tensor imaging and opens the door to further analysis of hardware impacts on performance.

  • Open Access

    The Effect of Voxel Volume and Voxel Shape on Cardiac Diffusion Tensor Imaging Metrics

    by Ariel J. Hannum, Tyler E. Cork, Kawin Setsompop, Daniel B. Ennis

    Purpose: Cardiac diffusion tensor imaging (cDTI) is signal‐to‐noise ratio (SNR)‐limited due to diffusion signal attenuation, long echo times from gradient moment nulling, and moderate myocardial T. Increasing voxel volume improves SNR but reduces spatial sensitivity and introduces physiological bias . This work aimed to identify the voxel configuration (volume and shape) yielding the most precise cDTI metrics. Methods: Spin‐echo cDTI protocols spanning nine voxel volumes were evaluated in healthy subjects (N = 11) at 3T. A gel phantom was scanned to compare SNR in a non‐physiologic environment. Temporal SNR and regression fits were computed. Mean diffusivity (MD), fractional anisotropy (FA), bootstrapped uncertainties (, ), Helix angle pitch (HAP), and the primary eigenvector's uncertainty () were then calculated, and significant () differences were assessed. Technique for order preference by similarity to ideal solution (TOPSIS) ranked configurations by uncertainties. Results: Phantom SNR trends corresponded to theory, with consistent SNR increases. In vivo SNR increases differed between in‐plane resolutions, in which mm in‐plane resolutions had the steepest slope. Higher in‐plane resolutions ( mm) yielded lower MD than lower resolutions ( mm). Higher in‐plane resolutions with thicker slices produced higher FA ( mm). HAP was steepest at moderate voxel sizes ( mm). All uncertainties decreased with 8 mm slices. TOPSIS ranked mm highest (0.91), then (0.83). Conclusion: In vivo differences in SNR slopes suggest a physiological bias‐dominated environment. The mm voxel configuration had the lowest uncertainties (highest TOPSIS score), followed by mm. This work provides a framework for evaluating the best cDTI voxel configuration.


  • Automated Global and Regional Segmentation of Cardiac Diffusion Tensor Images

    by Sascha W. Stocker, Ariel J. Hannum, Tyler E. Cork, Daniel B. Ennis

  • Characterizing Global and Regional Cardiac Diffusion Tensor Imaging Metrics in Healthy Subjects

    by Ariel J. Hannum, Tyler E. Cork, Luigi E. Perotti, Daniel B. Ennis

  • Evaluating Cardiac Strains from One and Two Short-Axis Slice Models Based on DENSE and Cine MRI

    by Augusto Delavald Marques, Mohammad Naqizadeh Jahromi, Luigi Wellner, Ariel J. Hannum, Zhan-Qiu Liu, Dazhong Wu, Daniel B. Ennis, Luigi E. Perotti


  • Evaluating the Effect of Post-processing Steps When Analyzing Cardiac Diffusion Tensor Data

    by Tyler E. Cork, Ariel J. Hannum, Michael Loecher, Luigi E. Perotti, Daniel B. Ennis


  • Phase stabilization with motion compensated diffusion weighted imaging

    by Ariel J. Hannum, Tyler E. Cork, Kawin Setsompop, Daniel B. Ennis

    Purpose: Diffusion encoding gradient waveforms can impart intra‐voxel and inter‐voxel dephasing owing to bulk motion, limiting achievable signal‐to‐noise and complicating multishot acquisitions. In this study, we characterize improvements in phase consistency via gradient moment nulling of diffusion encoding waveforms.Methods: Healthy volunteers received neuro () and cardiac () MRI. Three gradient moment nulling levels were evaluated: compensation for position (), position + velocity (), and position + velocity + acceleration (). Three experiments were completed: (Exp‐1) Fixed Trigger Delay Neuro DWI; (Exp‐2) Mixed Trigger Delay Neuro DWI; and (Exp‐3) Fixed Trigger Delay Cardiac DWI. Significant differences () of the temporal phase SD between repeated acquisitions and the spatial phase gradient across a given image were assessed.Results: moment nulling was a reference for all measures. In Exp‐1, temporal phase SD for diffusion encoding was significantly reduced with (35% of t‐tests) and (68% of t‐tests). The spatial phase gradient was reduced in 23% of t‐tests for and 2% of cases for . In Exp‐2, temporal phase SD significantly decreased with gradient moment nulling only for (83% of t‐tests), but spatial phase gradient significantly decreased with only (50% of t‐tests). In Exp‐3, gradient moment nulling significantly reduced temporal phase SD and spatial phase gradients (100% of t‐tests), resulting in less signal attenuation and more accurate ADCs.Conclusion: We characterized gradient moment nulling phase consistency for DWI. Using M1 for neuroimaging and M1 + M2 for cardiac imaging minimized temporal phase SDs and spatial phase gradients.


  • DTI‐MR fingerprinting for rapid high‐resolution whole‐brain T1, T2, proton density, ADC, and fractional anisotropy mapping

    by Xiaozhi Cao, Congyu Liao, Zihan Zhou, Zheng Zhong, Zhitao Li, Erpeng Dai, Siddharth Srinivasan Iyer, Ariel J. Hannum, Mahmut Yurt, Sophie Schauman, et al.

    Purpose: This study aims to develop a high‐efficiency and high‐resolution 3D imaging approach for simultaneous mapping of multiple key tissue parameters for routine brain imaging, including T1, T2, proton density (PD), ADC, and fractional anisotropy (FA). The proposed method is intended for pushing routine clinical brain imaging from weighted imaging to quantitative imaging and can also be particularly useful for diffusion‐relaxometry studies, which typically suffer from lengthy acquisition time.Methods: To address challenges associated with diffusion weighting, such as shot‐to‐shot phase variation and low SNR, we integrated several innovative data acquisition and reconstruction techniques. Specifically, we used M1‐compensated diffusion gradients, cardiac gating, and navigators to mitigate phase variations caused by cardiac motion. We also introduced a data‐driven pre‐pulse gradient to cancel out eddy currents induced by diffusion gradients. Additionally, to enhance image quality within a limited acquisition time, we proposed a data‐sharing joint reconstruction approach coupled with a corresponding sequence design.Results: The phantom and in vivo studies indicated that the T1 and T2 values measured by the proposed method are consistent with a conventional MR fingerprinting sequence and the diffusion results (including diffusivity, ADC, and FA) are consistent with the spin‐echo EPI DWI sequence.Conclusion: The proposed method can achieve whole‐brain T1, T2, diffusivity, ADC, and FA maps at 1‐mm isotropic resolution within 10 min, providing a powerful tool for investigating the microstructural properties of brain tissue, with potential applications in clinical and research settings.


  • Open Access

    Arbitrary Point Tracking with Machine Learning to Measure Cardiac Strains in Tagged MRI

    by Michael Loecher, Ariel J. Hannum, Luigi E. Perotti, Daniel B. Ennis

    Cardiac tagged MR images allow for deformation fields to be measured in the heart by tracking the motion of tag lines throughout the cardiac cycle. Machine learning (ML) algorithms enable accurate and robust tracking of tag lines. Herein, the use of a massive synthetic physics-driven training dataset with known ground truth was used to train an ML network to enable tracking any number of points at arbitrary positions rather than anchored to the tag lines themselves. The tag tracking and strain calculation methods were investigated in a computational deforming cardiac phantom with known (ground truth) strain values. This enabled both tag tracking and strain accuracy to be characterized for a range of image acquisition and tag tracking parameters. The methods were also tested on in vivo volunteer data. Median tracking error was< 0.26 mm in the computational phantom, and strain measurements were improved in vivo when using the arbitrary point tracking for a standard clinical protocol. Keywords Cardiac strains Machine learning MRI Tagging