Vicente Ferrer-López
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vicente Ferrer-López has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Fernando Santonja-Medina
Faculty of Medicine, University of Murcia, 30100 Murcia, Spain
2 shared publications - Fernando Santonja-Renedo
Primary Health Service Area IX, 30720 Murcia, Spain
2 shared publications - Francisco Javier Sánchez-Martínez
Medicine Faculty, University of Murcia, 30100 Murcia, Spain
2 shared publications - José Hurtado-Avilés
Sports & Musculoskeletal System Research Group (RAQUIS) Faculty of Medicine (University of Murcia) Murcia Spain
2 shared publications - Alejandro J. Castillo-Botero
Complejo Hospitalario Universitario de Cartagena
1 shared publication - Ana B. Ponce-Garrido
Department of Rehabilitation Sciences and Physiotherapy, General Hospital, Almansa, 02640 Albacete, Spain
1 shared publication
Latest Publications
- Open Access
- 9 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 565
The Validity and Absolute Reliability of Lower Extremity Angle Values on Full-Leg Standing Radiographs Using the TraumaMeter Software
To establish classifications and to obtain pre- and post-operative information on patient-specific alignments, it is necessary to measure different angular values accurately and precisely, mainly on weight-bearing, full-length anteroposterior X-rays of the lower limbs (LLRs). This study evaluated angular measurements’ validity and absolute reliability on LLRs with a self-developed, computer-aided measurement system (TraumaMeter v.873). Eight independent observers measured the preoperative mechanical hip-knee-ankle (mHKA) angle of 52 lower extremities (26 cases) in a blinded fashion on three occasions separated by two weeks. We obtained an intra-observer mean bias error (MBE) of 0.40°, a standard deviation (SD) of 0.11°, and a 95% confidence interval (CI) of 0.37°–0.43°. We also obtained an inter-observer MBE of 0.49°, an SD of 0.15°, and a 95% C of 0.45°–0.53°. The intra-observer MBE for the measurement pair between the second and the first measurement round (T2T1) was 0.43°, the SD was 0.13°, and the 95% CI was 0.39°–0.47°; the MBE between the third and the second round (T3T2) was 0.37°, with an SD of 0.10° and a 95% CI of 0.34°–0.40°; and the MBE between the third and the first round (T3T1) was 0.40°, with an SD of 0.10° and a 95% CI of 0.37°–0.43°. The interobserver MBE for the first round of measurements was 0.52°, with an SD of 0.16° and a 95% CI of 0.48°–0.56°; the MBE for the second round was 0.50°, with an SD of 0.15° and a 95% CI of 0.46°–0.54°; and the MBE for the third round was 0.46°, with an SD of 0.14° and a 95% CI of 0.42°–0.50°. There were no statistically significant differences in the inter-observer errors for the three tests. In the case of the intra-observer analysis, there were differences between T2T1 and between T3T2, but these differences were minimal, with no overlaps in the lower or upper values, respectively, of the confidence intervals. These results led us to conclude that the TraumaMeter v.873 software extension for measuring lower-limb angles in LLRs is an accurate tool with low intra- and inter-observer variability.
- 9 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 565
Open AccessThe Validity and Absolute Reliability of Lower Extremity Angle Values on Full-Leg Standing Radiographs Using the TraumaMeter Software
To establish classifications and to obtain pre- and post-operative information on patient-specific alignments, it is necessary to measure different angular values accurately and precisely, mainly on weight-bearing, full-length anteroposterior X-rays of the lower limbs (LLRs). This study evaluated angular measurements’ validity and absolute reliability on LLRs with a self-developed, computer-aided measurement system (TraumaMeter v.873). Eight independent observers measured the preoperative mechanical hip-knee-ankle (mHKA) angle of 52 lower extremities (26 cases) in a blinded fashion on three occasions separated by two weeks. We obtained an intra-observer mean bias error (MBE) of 0.40°, a standard deviation (SD) of 0.11°, and a 95% confidence interval (CI) of 0.37°–0.43°. We also obtained an inter-observer MBE of 0.49°, an SD of 0.15°, and a 95% C of 0.45°–0.53°. The intra-observer MBE for the measurement pair between the second and the first measurement round (T2T1) was 0.43°, the SD was 0.13°, and the 95% CI was 0.39°–0.47°; the MBE between the third and the second round (T3T2) was 0.37°, with an SD of 0.10° and a 95% CI of 0.34°–0.40°; and the MBE between the third and the first round (T3T1) was 0.40°, with an SD of 0.10° and a 95% CI of 0.37°–0.43°. The interobserver MBE for the first round of measurements was 0.52°, with an SD of 0.16° and a 95% CI of 0.48°–0.56°; the MBE for the second round was 0.50°, with an SD of 0.15° and a 95% CI of 0.46°–0.54°; and the MBE for the third round was 0.46°, with an SD of 0.14° and a 95% CI of 0.42°–0.50°. There were no statistically significant differences in the inter-observer errors for the three tests. In the case of the intra-observer analysis, there were differences between T2T1 and between T3T2, but these differences were minimal, with no overlaps in the lower or upper values, respectively, of the confidence intervals. These results led us to conclude that the TraumaMeter v.873 software extension for measuring lower-limb angles in LLRs is an accurate tool with low intra- and inter-observer variability.
- Open Access
- 12 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4655
Validity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software
The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software’s validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.
- 12 April 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (8) , 4655
Open AccessValidity and Absolute Reliability of the Cobb Angle in Idiopathic Scoliosis with TraumaMeter Software
The Cobb angle value is a critical parameter for evaluating adolescent idiopathic scoliosis (AIS) patients. This study aimed to evaluate a software’s validity and absolute reliability to determine the Cobb angle in AIS digital X-rays, with two different degrees of experienced observers. Four experts and four novice evaluators measured 35 scoliotic curves with the software on three separate occasions, one month apart. The observers re-measured the same radiographic studies on three separate occasions three months later but on conventional X-ray films. The differences between the mean bias errors (MBE) within the experience groups were statistically significant between the experts (software) and novices (manual) (p < 0.001) and between the novices (software) and novices (manual) (p = 0.005). When measured with the software, the intra-group error in the expert group was MBE = 1.71 ± 0.61° and the intraclass correlation coefficient (ICC (2,1)) = 0.986, and in the novice group, MBE = 1.9 ± 0.67° and ICC (2,1) = 0.97. There was almost a perfect concordance among the two measurement methods, ICC (2,1) = 0.998 and minimum detectable change (MCD95) < 0.4°. Control of the intrinsic error sources enabled obtaining inter- and intra-observer MDC95 < 0.5° in the two experience groups and with the two measurement methods. The computer-aided software TraumaMeter increases the validity and reliability of Cobb angle measurements concerning manual measurement.
- Open Access
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (2) , 212-217
MUSCLE OXYGENATION OF THE QUADRICEPS AND GASTROCNEMIUS DURING MAXIMAL AEROBIC EFFORT
Introduction: Near infrared spectroscopy (NIRS) is a non-invasive technique that is used in the assessment of tissue oxygenation and the monitoring of physical activity. Objective: To determine the influence of sexual, anthropometric and ergospirometric factors on muscle oxygenation of the quadriceps and gastrocnemius, obtained by NIRS during a stress test. Methods: Twenty healthy subjects participated in this study (10 women). Two Humon Hex® devices were placed on the dominant side of the quadriceps and gastrocnemius muscles to measure muscle oxygen saturation (SmO2). The stress test was performed on a treadmill with electrocardiographic control and measurement of oxygen consumption. SmO2 was obtained at rest and after maximum effort during the stress test. In addition, the height, weight, skinfold and waist contour were measured. Bioimpedance was used to obtain the percentages of fat mass and muscle mass, which were used to calculate the relative fat mass (RFM). Results: The SmO2 of both muscles at rest is higher in males than in females. At maximum effort, the SmO2 of the quadriceps is similar in both groups. The SmO2 of both muscles is positively related to height, body mass, percentage of mass muscle and waist contour, and negatively with percentage of mass fat, RFM and skinfold thickness. The negative correlation between fat percentage and oxygen saturation is more evident in females. It was observed that the variables that quantify maximum effort are not related to the SmO2 values, except for the correlation between HR max and SmO2 of the gastrocnemius muscle in males. Conclusion: The SmO2 of recreational athletes is influenced by the location of the device and the fat mass of the subjects. The biggest differences between the sexes are in the gastrocnemius muscle. Level of Evidence II; Diagnostic Studies - Investigating a Diagnostic Test .
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Revista Brasileira de Medicina do Esporte
- Vol. 27 (2) , 212-217
Open AccessMUSCLE OXYGENATION OF THE QUADRICEPS AND GASTROCNEMIUS DURING MAXIMAL AEROBIC EFFORT
Introduction: Near infrared spectroscopy (NIRS) is a non-invasive technique that is used in the assessment of tissue oxygenation and the monitoring of physical activity. Objective: To determine the influence of sexual, anthropometric and ergospirometric factors on muscle oxygenation of the quadriceps and gastrocnemius, obtained by NIRS during a stress test. Methods: Twenty healthy subjects participated in this study (10 women). Two Humon Hex® devices were placed on the dominant side of the quadriceps and gastrocnemius muscles to measure muscle oxygen saturation (SmO2). The stress test was performed on a treadmill with electrocardiographic control and measurement of oxygen consumption. SmO2 was obtained at rest and after maximum effort during the stress test. In addition, the height, weight, skinfold and waist contour were measured. Bioimpedance was used to obtain the percentages of fat mass and muscle mass, which were used to calculate the relative fat mass (RFM). Results: The SmO2 of both muscles at rest is higher in males than in females. At maximum effort, the SmO2 of the quadriceps is similar in both groups. The SmO2 of both muscles is positively related to height, body mass, percentage of mass muscle and waist contour, and negatively with percentage of mass fat, RFM and skinfold thickness. The negative correlation between fat percentage and oxygen saturation is more evident in females. It was observed that the variables that quantify maximum effort are not related to the SmO2 values, except for the correlation between HR max and SmO2 of the gastrocnemius muscle in males. Conclusion: The SmO2 of recreational athletes is influenced by the location of the device and the fat mass of the subjects. The biggest differences between the sexes are in the gastrocnemius muscle. Level of Evidence II; Diagnostic Studies - Investigating a Diagnostic Test .