PSPer Söderberg

Per Söderberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Per Söderberg has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic segmentation of the waist of the nerve fiber layer at the ONH with AI

    by Konstancija Kisonaite, Faisal Raeme, Zhaohua Yu, Camilla Sandberg Melin, Irene Brusini, Simone Bendazzoli, Chunliang Wang, Per Söderberg

    Purpose: To evaluate a machine learning AI‐tool for automatic segmentation of the waist of the nerve fiber layer at the optic nerve head (ONH).Methods: OCT‐volumes of the ONH were captured from eyes with early to manifest glaucoma (OCT‐2000) and eyes without glaucoma (OCT‐Triton). The angularly resolved segmentation consisted of first detecting the inner limit of the retina in the OCT volume with AI‐model I. Subsequently, the OCT volume was resampled into 500 radial images distributed at equidistant angles in the frontal plane. In each radial image, the Optic nerve head Pigment epithelium Central Limit (OPCL) was identified manually with a specially developed tool and automatically with AI‐model II. Model II was trained for OPCL location on a training set of radial images. Ground truth was provided as manual annotations. Finally, the Pigment‐epithelium‐Inner‐limit of the retina‐Minimal Distance (PIMD) was estimated at each angle as the shortest distance between OPCL and the closest point on the inner limit of the retina. PIMD estimated both automatically and based on manual annotation of OPCL were compared in a test data set. All radial images in the test data set were manually annotated by three different annotators.Results: For both groups of eyes examined, the automatic and manual estimates of the angular distribution of PIMD overlapped. The eyes without glaucoma expressed the expected peak thickness of the waist of the nerve fiber layer inferiorly and superiorly, while the glaucomatous eyes lost most of this angular dependence. A 95% confidence interval for the mean difference of automatically estimated PIMD between eyes without glaucoma and glaucomatous eyes was 220 ± 85 μm. An analysis of interobserver variability in PIMD‐estimates demonstrated minor differences.Conclusions: AI‐based estimation of the waist of the nerve fiber layer at the ONH angularly resolved is reliable and precise enough to detect a difference between early to manifest glaucoma and non‐glaucoma.

  • Open Access

    Evaluation of a new digital visual acuity chart for best‐corrected visual acuity estimation

    by Zhaohua Yu, Per Söderberg

    Purpose: To compare estimated best‐corrected visual acuity (BCVA) between the digital chart named AxAnIvIs and the ETDRS chart at different level of acuity, and to determine if there is difference of the test time between the two systems.Methods: Patients at the eye clinic of Uppsala university hospital that met the inclusion criteria (age >55 years, BCVA [1.0; −0.1] and no ocular disease strongly considered to cause visual acuity change within one month) were asked to participate this study. The AxAnIvIs system uses a custom made algorithm for optotypes visualisation where optotypes decrease in size horizontally in one line. Altogether 16 subjects (8 male, 8 female) were included and distributed equally to four visual acuity classes ([1.0 0.8], [0.7 0.5], [0.4 0.2], [0.1 −0.1] logMAR). Each subject’s BCVA was measured and the test time was recorded with the two systems on two separate occasions.Results: The mean BCVA difference between the AxAnIvIs system and the ETDRS chart at visual acuity class of [1.0 0.8], [0.7 0.5], [0.4 0.2], [0.1 −0.1] logMAR was estimated as a CI(95%), 0.02 ± 0.04, 0.02 ± 0.08, ‐0.01 ± 0.05, 0.03 ± 0.07 logMAR, respectively. ANOVA shows that there is no significant difference between the two systems and no significant difference between the two systems at the different visual acuity classes. The mean test time between the AxAnIvIs system and the ETDRS chart was estimated as a CI(95%), −37 ± 15 s.Conclusions: The AxAnIvIs system can be used as a replacement of the ETDRS chart for general examination. The test time with the AxAnIvIs system is half minute shorter than that with the ETDRS chart.

  • Open Access

    Variance components for PIMD‐2π estimation of the optic nerve head and consequences in clinical measurements of glaucoma

    by Camilla Sandberg Melin, Zhaohua Yu, Per G. Söderberg

    Purpose To estimate the sources of variation for Pigment epithelium central limit-Inner limit of the retina Minimal Distance averaged over 2π (PIMD-2π), and further to analyse their consequences for clinical measurements of glaucoma. Methods Forty subjects with early to moderate stage glaucoma were included. Three SD-OCT volumes of the optic nerve head (ONH) were captured at two occasions. Each volume was segmented three times for PIMD-2π. The magnitude of the sources of variation for PIMD-2π measurements was estimated with an analysis of variance. Results A 95% confidence interval for mean PIMD-2π was estimated to 215 ± 12 μm (df = 38). The estimated variance for subjects was 1280 μm2. The within-subject estimated variance for occasions, volumes and segmentations was 10 μm2, 30 μm2 and 40 μm2, respectively. The within-subject variances were used to model follow-up of PIMD-2π over time. A linear loss rate of 0.05 of baseline PIMD-2π/year was assumed. A significant PIMD-2π change could be detected in approximately 16–18 months with evenly spaced visits every 4 or 6 months. Conclusions Due to the small within-subject estimated variances, a clinically undesirable PIMD-2π change from baseline can be detected in approximately 18 months. Detection of significant PIMD-2π loss in a subject requires knowledge of normal age loss and measurement variability.


  • Development of an algorithm for corneal reshaping with a scanning laser beam

    by Fabrice Manns, Jin-Hui Shen, Per Söderberg, Takaaki Matsui, Jean-Marie Parel

    Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.