IOIbrahim Ozdur

Ibrahim Ozdur

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ibrahim Ozdur has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature- and Pressure-Dependent Calibration Transfer Bias of WMS, FWMS, and DAS Methane Retrievals near 1654 nm

    by Murat Guder, Ibrahim T. Ozdur

    Temperature and pressure changes can introduce substantial bias when a tunable diode laser absorption spectroscopy calibration is used away from its reference condition. Here, scanned wavelength modulation spectroscopy (WMS), fixed-wavelength MS (FWMS), and integrated area direct absorption spectroscopy (DAS) are compared for the CH4 R(3) manifold near 1654 nm. To isolate the behavior of the retrieval methods, all three simulations use the same HITRAN2020 line-by-line model, optical depth, laser model, target geometry, and calibration state. The analysis covers temperature variation at constant pressure, pressure variation at constant temperature, and coupled temperature–pressure variation in a closed volume. With temperature held constant, the FWMS bias varies from −5.2% to −0.8% over 0.7–1.1 atm. At constant pressure, it changes from +23.4% to −9.8% between −20 and +40 °C. DAS gives the smallest endpoint bias in the closed-volume case, ranging from +19.1% to −8.0%. Across all 35 operating points, the RMSE is 10.5% for FWMS, 13.4% for WMS, and 14.9% for DAS. The pooled ranking is unchanged for modulation indices between 1.6 and 3.0 and for DAS integration windows between ±10 and ±100 GHz.

  • Open Access

    Photonic-assisted multi-band RF channelization and digitization for 5G frequency bands

    by Abdulkadir Yentur, Mehmet Ziya Keskin, Ibrahim Ozdur

    In this study, we introduce a photonic-assisted RF channelization method capable of simultaneously down-converting and digitizing multiple RF bands through photonic down-conversion and photonic analog-to-digital conversion (ADC). The method is demonstrated across the three frequency ranges used in 5G signals, with center frequencies at 700 MHz, 3700 MHz, and 27000 MHz. Each RF band is optically sampled and photonic down-converted to the 0–2 GHz range without any frequency band overlap using a custom mode-locked laser running at 4.05 GHz optical pulse repetition frequency, 1.6 ps pulse width and 11.4 fs integrated timing jitter (100 Hz – 10 MHz). The sampled signal is then digitized using photonic ADC technique. The resulting effective number of bits (ENOB) values for the 700 MHz, 3700 MHz, and 27000 MHz bands are 9.8, 9.2, and 5.8 bits, respectively.

  • A Compliant Mandrel-Based Fiber-Optic Hydrophone for Underwater Acoustic Sensing

    by Faruk Uyar, A. Safa Aldemir, Tolga Kartaloğlu, Ekmel Özbay, Ibrahim Özdür

    This article presents the design, numerical modeling, and experimental validation of a mandrel-based fiber-optic hydrophone (FOH) tailored for underwater acoustic sensing. The hydrophone leverages a compliant mandrel structure to transduce radial pressure-induced strain into axial strain along an optical fiber wound around the mandrel, with acoustic signals retrieved via interferometric techniques. A comprehensive 3-D finite element model is developed to evaluate the mechanical response and sensitivity characteristics of the hydrophone. Experimental validation is conducted in a water tank using a calibrated piezoelectric transducer, confirming the simulated predictions. The designed FOH exhibits a mean acoustic pressure sensitivity of -135.28 dB re rad/ $\mu $ Pa over the frequency range of 250 Hz–8 kHz, which is competitive with state-of-the-art FOH designs reported in recent literature. The pressure noise floor characterization yielded a value of 43.28 dB re rad2/Hz at 1 kHz, demonstrating the hydrophone’s capability to detect weak acoustic signals below deep-sea state 0 (DSS0) up to frequencies above 1 kHz. The results suggest that this mandrel-based FOH design offers a robust, scalable, and cost-effective solution for large-scale underwater acoustic monitoring systems, with strong potential for integration into fiber-optic sensor arrays used in oceanographic, industrial, and defense applications.


  • Open Access

    Dual Interferometric Interrogation for DFB Laser-Based Acoustic Sensing

    by Mehmet Ziya Keskin, Abdulkadir Yentur, Ibrahim Ozdur

    Acoustic sensing has many applications in engineering, one of which is fiber-optic hydrophones (FOHs). Conventional piezoelectric hydrophones face limitations related to size, electromagnetic interference, corrosion, and narrow operating bandwidth. Fiber-optic hydrophones, particularly those employing distributed feedback (DFB) lasers, offer a compelling alternative due to their mechanical flexibility, resistance to harsh conditions, and broad detection range. DFB lasers are highly sensitive to external perturbations such as temperature and strain, enabling the precise detection of underwater acoustic signals by monitoring the resultant shifts in lasing wavelength. This paper presents an enhanced interrogation mechanism that leverages Mach–Zehnder interferometers to translate wavelength shifts into measurable phase deviations, thereby providing cost-effective and high-resolution phase-based measurements. A dual interferometric setup is integrated with a standard demodulation algorithm to extend the dynamic range of these sensing systems. The experimental results demonstrate a substantial improvement in performance, with the dynamic range increasing from 125 dB to 139 dB at 1 kHz without degrading the noise floor. This enhancement significantly expands the utility of FOH-based systems in underwater environments, supporting applications such as underwater surveillance, submarine communication, and marine ecosystem monitoring.


  • Open Access

    Design and Empirical Validation of a Low-Cost Outdoor mmWave Altimetry Test Bench for UAS

    by Mohammad Derawi, Maaz Ali Awan, Adem Sahin, Yaser Dalveren, Ibrahim Ozdur, Ali Kara

    The increasing adoption of unmanned aerial systems (UAS) in diverse urban applications necessitates reliable and precise altimetry solutions for situational awareness and landing safety. Despite significant advancements in the realm of waveform design and signal processing, empirical validation of millimeter wave (mmWave) Frequency Modulated Continuous Wave (FMCW) waveforms for altimetry use case remains a critical gap in literature. This study argues the necessity of empirical validation of candidate FMCW waveforms by proposing an inexpensive and practical outdoor test bench. The multipath propagation model for the said test bench is presented along with a simplified testing methodology suitable for implementation on contemporary mmWave automotive radars. The specifics of the test bench are deliberated where a flat concrete wall with a sufficiently large surface area is employed as a static target. The underpinnings established by this body of work shall serve dynamic testing on a drone platform against various terrain types in the next phase of research. The experimental results demonstrate the potential of practical use of mmWave altimetry on UAS in urban deployment.

  • A Dispersion Managed Phase Only Modulation 18 GHz Optoelectronic Oscillator

    by Ibrahim T. Ozdur, Sarper Ozharar

    In this manuscript, we propose and experimentally demonstrate a dispersion controlled optoelectronic oscillator with phase only modulator at 18 GHz. The generated microwave signal has a phase noise of -108 dBc/Hz at 10 kHz offset frequency and the integrated timing jitter is calculated to be 16.2 fs (1 kHz to 100 MHz) and 20 fs (1kHz to Nyquist).

  • Open Access

    A Direct Detection Fiber Optic Distributed Acoustic Sensor With a Mean SNR of 7.3 dB at 102.7 km

    by Faruk Uyar, Talha Onat, Canberk Unal, Tolga Kartaloglu, Ekmel Ozbay, Ibrahim Ozdur

    In this work, we present the experimental results of a direct detection ${\varphi}$ -OTDR based distributed acoustic sensor system. The system uses two cascaded acousto-optic modulators in order to generate optical pulses with very high extinction ratio and dual photodetector scheme for high dynamic range. The proposed schemes are investigated in detail and their performance enhancement is experimentally verified. Four piezoelectric based fiber stretchers are placed on a ~104 km single-mode test fiber at the distances of 1 km, 10 km, 87 km and 102.7 km and used for perturbation tests. The stretchers generated vibration signals which are analyzed to quantify the system performance. The signal-to-noise ratio (SNR) of vibration signals at the monitored distances is measured over the 12-hour recorded data within 34-second time windows considering the multi-point random interference of scattered light and fading phenomena. Using the 12-hour data, SNR histograms at four different locations are generated and mean SNR values are obtained. The signals received from 102.7 km has a maximum SNR of 24.7 dB and a mean SNR of 7.3 dB with a spatial resolution of 15 m. To the best of our knowledge, this is the highest-range reported direct detection ${\varphi}$ -OTDR based distributed acoustic sensor system.


  • 94.8 Km-Range Direct Detection Fiber Optic Distributed Acoustic Sensor

    by Faruk Uyar, Talha Onat, Canberk Unal, Tolga Kartaloglu, Ibrahim Ozdur, Ekmel Ozbay

    This work demonstrates an ultra-long range direct detection fiber optic distributed acoustic sensor which can detect vibrations at a distance of 94.8 km with 10 m resolution along the sensing fiber.


  • Use of laser-induced bubbles in intraocular pressure measurement: a preliminary study

    by Fatih Altindis, Ibrahim T Ozdur, Sait N Mutlu, Bulent Yilmaz

    This work investigates the feasibility of a novel approach for measuring intraocular pressure (IOP) by analyzing micron-level laser-induced bubble characteristics in the intraocular fluid. We believe that this concept may be used as a non-invasive alternative for measuring a patient’s IOP by analyzing the laser-induced bubble volume in the intraocular fluid in the anterior chamber of the eye. The behavior of laser-induced bubbles was examined under differing fluid pressure levels and at differing laser pulse energy levels. An intraocular medium-like environment was imitated and an imaging system was designed in order to capture laser-induced bubbles with their movements. The video recordings of the bubbles were processed using custom software, and the volume of the bubbles was estimated using three different approaches. The bubble volumes were estimated more accurately by using the rising velocity of the bubble rather than its direct radii appearances on the images. An inversely proportional relationship was observed between the laser-induced bubble volume and the fluid pressure. IOP can be measured with a non-invasive technique using laser-induced bubble volume. Deeper and detailed studies, including clinical studies, may lead to the use of lasers for measuring IOP.