GCGuillaume Cathelain

Guillaume Cathelain

*This is an algorithmically generated author record based on publicly available information.

Guillaume Cathelain has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Ballistocardiography and applications

    by Guillaume Cathelain

    Ballistocardiographie et applications: À l’échelle mondiale, les systèmes de santé ont des coûts croissants et le nombre d’hospitalisations augmente. La télémédecine permet de ramener l’hôpital à la maison et offre aux structures de santé de nouvelles possibilités d’améliorer le parcours de soins des patients. La surveillance physiologique est une condition préalable à l’efficacité des systèmes de télémédecine et est assurée par des dispositifs médicaux connectés qui ne sont pas entièrement automatisés. Les patients doivent les utiliser activement au quotidien : ces inconvénients entraînent soit un désengagement du patient, soit du personnel soignant supplémentaire. Les moniteurs passifs et sans contact des signes vitaux, tels que les ballistocardiographes qui mesurent les activités motrices, respiratoires et cardiaques, peuvent résoudre l’inefficacité de la télémédecine. En outre, ils sont plus confortables et plus sûrs pour les patients que les moniteurs traditionnels, ce qui est crucial pour le développement neurologique néonatal ou dans les cas de dégénérescence mentale, bien qu’ils soient actuellement moins précis. Comment améliorer la précision de la surveillance physiologique en ballistocardiographie pour accroître l’efficacité de la télémédecine ? Dans cette thèse, le matériel est fourni par une instrumentation propriétaire basée sur un accéléromètre, un logiciel dédié, un simulateur de battements cardiaques, et des campagnes de mesure pour les bases de données de ballistocardiogrammes bruts. De nouvelles méthodes d’amplification analogique et de filtrage numérique sont étudiées pour améliorer la précision de la ballistocardiographie. La force ballistocardiographique, provenant de la déformation de la crosse aortique lors de la systole ventriculaire et mesurée sur le côté du lit, est en effet modulée par les activités respiratoires et motrices, et est polluée par les artefacts mécaniques de l’environnement. En outre, la ballistocardiographie n’est pas normalisée et les ballistocardiogrammes présentent des variabilités inter et intra-individuelles élevées, en fonction de la literie, de la position au lit, de la morphologie et de la physiologie du patient. L’amplification analogique est étudiée d’un point de vue mécanique et électronique. Premièrement, en ce qui concerne l’amplification mécanique, un nouveau guide d’ondes, prenant la forme d’un ruban de coton qui encercle le matelas, a été inventé pour concentrer l’énergie de la force ballistocardiographique dans une direction, du thorax jusqu’au capteur. Deuxièmement, en ce qui concerne l’amplification électronique, un circuit de conditionnement hybride a été conçu pour optimiser le compromis entre le gain de l’amplificateur électronique et la durée de saturation après un mouvement. Les méthodes de filtrage numérique visent à séparer les sources de signaux, à éliminer les artefacts puis à détecter les signes vitaux. Trois algorithmes originaux ont été conçus pour reconnaître efficacement les battements de cœur dans les ballistocardiogrammes. Le premier algorithme est la comparaison par déformation temporelle dynamique, où un modèle battement cardiaque est utilisé pour reconnaître les battements cardiaques en utilisant une distance non-linéaire. Le second algorithme modélise les ballistocardiogrammes avec des modèles de Markov cachés périodiques. Le troisième algorithme, le réseau neuronal U-Net, est supervisé et segmente les battements cardiaques en ballistocardiogrammes. Finalement, les ballistocardiogrammes sont amplifiés mécaniquement et électroniquement de 12 dB et 21 dB respectivement, sans saturation après mouvement ; et les algorithmes de filtrage numérique atteignent une précision de 97 % et une sensibilité de 96 % pour la détection des battements cardiaques. Prochainement, le ballistocardiographe conçu sera évalué cliniquement dans une unité de soins intensifs pédiatriques et en télémédecine par rapport à d’autres ballistocardiographes et aux méthodes de référence.

  • Open Access

    Evaluation of the Clinical Performance of a Chest-Worn Smartphone-based Medical Device for Sleep Apnea-Hypopnea Syndrome Diagnosis: The EASY Study

    by Justine Frija, Thi Ngoc Bich Diep, Maria Trinidad Díaz-Cambriles, Wojciech Trzepizur, A. Abad Fernández, Ala Covali, Jean-Arthur Micoulaud-Franchi, Anja Seiger, Simon Gaudier, Claire Launois, et al.

    Background: Systems that record sounds and inertial signals from a smartphone placed on the thorax have the potential to increase access to sleep-apnoea diagnosis, but evaluations against polysomnography (PSG) are lacking. The EASY study evaluated the diagnostic performance of Apneal®, a smartphone Software as a Medical Device, to estimate the apnea–hypopnea index (AHI) and detect clinically relevant AHI thresholds compared with PSG.Methods: Prospective, multicentre clinical study in nine European sleep centres. Adults referred for diagnostic overnight PSG had in-lab PSG (central scoring) and simultaneous Apneal® v1.0.0 with Apneal® AI v1.3.1 recording with a consumer smartphone secured to the chest using an adhesive band. The primary objective was diagnostic performance at AHI thresholds (≥5, ≥15, ≥30 events/hour) versus PSG ; secondary objectives included continuous AHI agreement, comparison to polygraphy and nocturnal oximetry. The statistical analysis plan was prespecified; main diagnostic metrics reported are sensitivity, specificity, positive and negative predictive values (PPV, NPV), and area under the ROC curve (AUC) with 95% CIs.Findings: 491 participants were enrolled, and 432 analyzed. Apneal® severity classification versus adjudicated PSG had a quadratic-weighted κ = 0.88 (95% CI 0.83–0.92). At prespecified binary thresholds: for AHI ≥5 sensitivity 97% (95% CI 95–98), specificity 78% (61–89), PPV 98% (96–99), NPV 70% (54–83); for AHI ≥15 sensitivity 91% (87–94), specificity 91% (85–94), PPV 93% (89–96), NPV 88% (82–92); for AHI ≥30 sensitivity 84% (77–90), specificity 95% (92–97), PPV 88% (81–93), NPV 94% (90–96).Interpretation: Apneal® — a smartphone placed on the thorax and processed by a locked AI pipeline — provided accurate AHI estimates and high discrimination for clinically relevant thresholds compared with adjudicated PSG in a large, multicentre, real-world population. Performance was robust across the spectrum of severity.

  • Open Access

    Proposition of a new, minimally-invasive, software smartphone device to predict sleep apnea and its severity

    by Justine Frija, Juliette Millet, Emilie Béquignon, Ala Covali, Guillaume Cathelain, Josselin Houenou, Hélène Benzaquen, Pierre A. Geoffroy, Emmanuel Bacry, Mathieu Grajoszex, et al.

    Purpose obstructive sleep apnea is underdiagnosed due to limited access to polysomnography (PSG). We aimed to assess the performances of Apneal®, an application recording sound and movements thanks to a smartphone’s microphone, accelerometer and gyroscope, to estimate patients’ apnea-hypopnea index (AHI). Methods monocentric proof-of-concept study with a first manual scoring step, then automatic detection of respiratory events from recorded signals using a sequential deep-learning model (version 0.1 of Apneal® automatic scoring of respiratory events, end 2022), in adult patients. Results 46 patients (women 34%, BMI 28.7 kg/m²) were included. Sensitivity of manual scoring was 0.91 (95% CI [0.8-1]) for IAH > 15 and 0.85 [0.67-1] for AHI > 30, and positive predictive values (PPV) 0.89 [0.76–0.97] and 0.94 [0.8-1]. We obtained an AUC-ROC of 0.85 (95% CI [0.69–0.96]) and AUC-PR of 0.94 (95% CI [0.84–0.99]) for the identification of AHI > 15, and AUC-ROC of 0.95 [0.860.99] and AUC-PR of 0.93 [0.81–0.99] for AHI > 30. The ICC between the AHI estimated manually, and from the PSG is 0.89 (p = 6.7 × 10− 17), Pearson correlation 0.90 (p = 1.25 × 10− 17). Automatic scoring found sensitivity of 1 [0.95-1], PPV of 0.9 [0.8–0.9] for AHI > 15, and sensitivity 0.95 [0.84-1], PPV 0.69 [0.52–0.85] for AHI > 30. The ICC between the estimated AHI, and PSG scorings is 0.84 (p = 5.4 × 10− 11) and Pearson correlation is 0.87 (p = 1.7 × 10− 12). Conclusion Manual scoring of smartphone-based signals is possible and accurate compared to PSG-based scorings. Automatic scoring method based on a deep learning model provides promising results. Trial registration NCT03803098.


  • Bench testing of tracheostomy tube-related insults using an instrumented manikin

    by Guillaume Cathelain, Antoine Perrier, Ludivine Folliot, Cyrielle Le Gloanec, Mohamed Rarrbo, François Jouen, Etienne Saudeau, Guillaume Costa, Robert Carlier, Jean Bergounioux

    Purpose Choosing the right tracheal tube for the right patient is a daily preoccupation for intensivists and emergency physicians. Tracheal tubes can generate severe complications, which are chiefly due to the pressures applied by the tube to the trachea. We designed a bench study to assess the frequency of pressure levels likely to cause tracheal injury. Methods We tested the pressure applied on the trachea by 17 tube models of a given size range. To this end, we added a pressure sensor to the posterior tracheal wall of a standardized manikin. Results Only 2 of the 17 tubes generated pressures under the threshold likely to induce tracheal injury (30 mmHg/3.99 kPa). The force exerted on the posterior wall of the trachea varied widely across tube models. Conclusion Most models of tracheal tubes resulted in forces applied to the trachea that are usually considered capable of causing tracheal tissue injury. Level of evidence Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence: How common is the problem?: step 1; Is this diagnostic or monitoring test accurate? (Diagnosis) step 5; What will happen if we do not add a therapy? (Prognosis) n/a; Does this intervention help? (Treatment Benefits) step 5; What are the COMMON harms?(Treatment Harms) step 5; What are the RARE harms? (Treatment Harms) step 5; Is this (early detection) test worthwhile? (Screening) step 5.


  • Smart ballistocardiography front-end

    by Guillaume Cathelain, Bertrand Rivet, Sophie Achard, Jean Bergounioux, Francois Jouen

    Ballistocardiography (BCG), a contactless heart rate monitoring method, has the potential to measure vital signs and reduce neonates’ monitoring pain and discomfort. It uses an accelerometer on the mattress side. As the signal amplitude is very low, the front-end circuit needs a high amplifier gain and thus is very sensitive to baseline wander and noise. However, the usual analogue baseline wander filters are slow to settle, and the individual plus the bed are a damping system which generates noise at its resonance frequency. Consequently, the BCG signal is likely to saturate for several seconds every time the individual moves. This paper introduces a novel smart BCG front-end which identifies the system resonance frequency, filters the baseline wander and the damping noise, and highly amplifies the BCG signal without saturation after patient movement. It has been successfully tested on an experimental model and opens possibilities for medical, real-time and low-cost applications.


  • Dynamic Time Warping for Heartbeat Detection in Ballistocardiography

    by Guillaume Cathelain, Bertrand Rivet, Sophie Achard, Jean Bergounioux, François Jouen