Carlos A. Rios Perez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Carlos A. Rios Perez has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Carlos H. Hidrovo
Multiscale Thermal Fluids Laboratory, Mechanical and Industrial Engineering Department, Northeastern University, Boston, USA
7 shared publications Onur N. Demirer
3 shared publicationsRebecca L. Clifton
3 shared publications- Mark R. Deinert
The Colorado School of Mines
2 shared publications Rachel M. Naylor
2 shared publicationsRachel Naylor
2 shared publications
Latest Publications
- 1 March 2017
- Published by Elsevier in Applied Energy
- Vol. 189, 31-43
A thermophysical battery for storage-based climate control
- 1 March 2017
- Published by Elsevier in Applied Energy
- Vol. 189, 31-43
A thermophysical battery for storage-based climate control
- 10 November 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 139 (3) , 032003
Performance Improvement of Capacitive Deionization for Water Desalination Using a Multistep Buffered Approach
Due to the increasing demand for clean and potable water stemming from population growth and exacerbated by the scarcity of fresh water resources, more attention has been drawn to innovative methods for water desalination. Capacitive deionization (CDI) is a low maintenance and energy efficient technique for desalinating brackish water, which employs an electrical field to adsorb ions into a high-porous media. After the saturation of the porous electrodes, their adsorption capacity can be restored through a regeneration process. Herein, based on a physical model previously developed, we conjecture that for a given amount of time and volume of water, multiple desalination cycles in a high flow rate regime will outperform desalinating in a single cycle at a low flow rate. Moreover, splitting a CDI unit into two subunits, with the same total length, will lead to higher desalination. Based on these premises, we introduce a new approach aimed at enhancing the overall performance of CDI. An array of CDI cells are sequentially connected to each other with intermediate solutions placed in between them. Desalination tests were conducted to compare the performance of the proposed system, consisting of two CDI units and one intermediate solution buffer, with a two-cascaded-CDI unit system with no intermediate solution. Experimental data demonstrated the improved performance of the buffered system over the nonbuffered system, in terms of desalination percentage and energy consumption. The new proposed method can lead to lower amount of energy consumed per unit volume of the desalinated water.
- 10 November 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 139 (3) , 032003
Performance Improvement of Capacitive Deionization for Water Desalination Using a Multistep Buffered Approach
Due to the increasing demand for clean and potable water stemming from population growth and exacerbated by the scarcity of fresh water resources, more attention has been drawn to innovative methods for water desalination. Capacitive deionization (CDI) is a low maintenance and energy efficient technique for desalinating brackish water, which employs an electrical field to adsorb ions into a high-porous media. After the saturation of the porous electrodes, their adsorption capacity can be restored through a regeneration process. Herein, based on a physical model previously developed, we conjecture that for a given amount of time and volume of water, multiple desalination cycles in a high flow rate regime will outperform desalinating in a single cycle at a low flow rate. Moreover, splitting a CDI unit into two subunits, with the same total length, will lead to higher desalination. Based on these premises, we introduce a new approach aimed at enhancing the overall performance of CDI. An array of CDI cells are sequentially connected to each other with intermediate solutions placed in between them. Desalination tests were conducted to compare the performance of the proposed system, consisting of two CDI units and one intermediate solution buffer, with a two-cascaded-CDI unit system with no intermediate solution. Experimental data demonstrated the improved performance of the buffered system over the nonbuffered system, in terms of desalination percentage and energy consumption. The new proposed method can lead to lower amount of energy consumed per unit volume of the desalinated water.
- 18 January 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (3) , 032003
Performance Characterization of a Capacitive Deionization Water Desalination System With an Intermediate Solution and Low Salinity Water
In recent years, more efforts have been made to improve new and more efficient nonmembrane-based methods for water desalination. Capacitive deionization (CDI), a novel technique for water desalination using an electric field to adsorb ions from a solution to a high-porous media, has the capability to recover a fraction of the energy consumed for the desalination during the regeneration process, which happens to be its most prominent characteristic among other desalination methods. This paper introduces a new desalination method that aims at improving the performance of traditional CDI systems. The proposed process consists of an array of CDI cells connected in series with buffer containers in between them. Each buffer serves two purposes: (1) averaging the outlet solution from the preceding cell and (2) securing a continuous water supply to the following cell. Initial evaluation of the proposed CDI system architecture was made by comparing a two-cell-one-buffer assembly with a two cascaded cells array. Concentration of the intermediate solution buffer was the minimum averaged concentration attained at the outlet of the first CDI cell, under a steady-state condition. The obtained results show that the proposed CDI system with intermediate solution had better performance in terms of desalination percentage. This publication opens new opportunities to improve the performance of CDI systems and implement this technology on industrial applications.
- 18 January 2016
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 138 (3) , 032003
Performance Characterization of a Capacitive Deionization Water Desalination System With an Intermediate Solution and Low Salinity Water
In recent years, more efforts have been made to improve new and more efficient nonmembrane-based methods for water desalination. Capacitive deionization (CDI), a novel technique for water desalination using an electric field to adsorb ions from a solution to a high-porous media, has the capability to recover a fraction of the energy consumed for the desalination during the regeneration process, which happens to be its most prominent characteristic among other desalination methods. This paper introduces a new desalination method that aims at improving the performance of traditional CDI systems. The proposed process consists of an array of CDI cells connected in series with buffer containers in between them. Each buffer serves two purposes: (1) averaging the outlet solution from the preceding cell and (2) securing a continuous water supply to the following cell. Initial evaluation of the proposed CDI system architecture was made by comparing a two-cell-one-buffer assembly with a two cascaded cells array. Concentration of the intermediate solution buffer was the minimum averaged concentration attained at the outlet of the first CDI cell, under a steady-state condition. The obtained results show that the proposed CDI system with intermediate solution had better performance in terms of desalination percentage. This publication opens new opportunities to improve the performance of CDI systems and implement this technology on industrial applications.
- 1 April 2013
- Published by Elsevier in Desalination
- Vol. 314, 130-138
Energetic performance optimization of a capacitive deionization system operating with transient cycles and brackish water
- 1 April 2013
- Published by Elsevier in Desalination
- Vol. 314, 130-138
Energetic performance optimization of a capacitive deionization system operating with transient cycles and brackish water
- 22 February 2013
- Published by ASME International in Journal of Fluids Engineering
- Vol. 135 (4) , 041201
Characterization of Ion Transport and -Sorption in a Carbon Based Porous Electrode for Desalination Purposes
New and more efficient water desalination technologies have been a topic of incipient research over the past few decades. Although the focus has been placed on the improvement of membrane-based desalination methods such as reverse osmosis, the development of new high surface area carbon-based-electrode materials have brought substantial interest towards capacitive deionization (CDI), a novel technique that uses an electric field to separate the ionic species from the water. Part of the new interest on CDI is its ability to store and return a fraction of the energy used in the desalination process. This characteristic is not common to other electric-field-based desalination methods such as electro-deionization and electrodialysis reversal where none of the input energy is recoverable. This paper presents work conducted to analyze the energy recovery, thermodynamic efficiency, and ionic adsorption/desorption rates in a CDI cell using different salt concentration solutions and various flow rates. Voltage and electrical current measurements are conducted during the desalination and electrode regeneration processes and used to evaluate the energy recovery ratio. Salinity measurements of the inflow and outflow stream concentrations using conductivity probes, alongside the current measurements, are used to calculate ion adsorption efficiency. Two analytical species transport models are developed to estimate the net ionic adsorption rates in a steady-state and nonsaturated porous electrode scenario. Finally, the convective and electrokinetic transport times are compared and their effect on desalination performance is presented. Steady test results for outlet to inlet concentration ratio show a strong dependence on flow rate and concentration independence for dilute solutions. In addition, transient test results indicate that the net electrical energy requirement is dependent on the number of carbon electrode regeneration cycles, which is thought to be due to imperfect regeneration. The energy requirements and adsorption/desorption rate analyses conducted for this water-desalination process could be extended to other ion-adsorption applications such as the reprocessing of lubricants or spent nuclear fuels in a near future.
- 22 February 2013
- Published by ASME International in Journal of Fluids Engineering
- Vol. 135 (4) , 041201
Characterization of Ion Transport and -Sorption in a Carbon Based Porous Electrode for Desalination Purposes
New and more efficient water desalination technologies have been a topic of incipient research over the past few decades. Although the focus has been placed on the improvement of membrane-based desalination methods such as reverse osmosis, the development of new high surface area carbon-based-electrode materials have brought substantial interest towards capacitive deionization (CDI), a novel technique that uses an electric field to separate the ionic species from the water. Part of the new interest on CDI is its ability to store and return a fraction of the energy used in the desalination process. This characteristic is not common to other electric-field-based desalination methods such as electro-deionization and electrodialysis reversal where none of the input energy is recoverable. This paper presents work conducted to analyze the energy recovery, thermodynamic efficiency, and ionic adsorption/desorption rates in a CDI cell using different salt concentration solutions and various flow rates. Voltage and electrical current measurements are conducted during the desalination and electrode regeneration processes and used to evaluate the energy recovery ratio. Salinity measurements of the inflow and outflow stream concentrations using conductivity probes, alongside the current measurements, are used to calculate ion adsorption efficiency. Two analytical species transport models are developed to estimate the net ionic adsorption rates in a steady-state and nonsaturated porous electrode scenario. Finally, the convective and electrokinetic transport times are compared and their effect on desalination performance is presented. Steady test results for outlet to inlet concentration ratio show a strong dependence on flow rate and concentration independence for dilute solutions. In addition, transient test results indicate that the net electrical energy requirement is dependent on the number of carbon electrode regeneration cycles, which is thought to be due to imperfect regeneration. The energy requirements and adsorption/desorption rate analyses conducted for this water-desalination process could be extended to other ion-adsorption applications such as the reprocessing of lubricants or spent nuclear fuels in a near future.
- 4 January 2013
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (3) , E13-E21
Macro Analysis of the Electro-Adsorption Process in Low Concentration NaCl Solutions for Water Desalination Applications
Capacitive deionization (CDI) has become a very attractive desalination technology due to its capability of returning a fraction of the input energy during the regeneration of its adsorbent electrodes. As in any separation technique, analysis of the mass transfer phenomena occurring in this water treatment method is vital to evaluate and extend the performance of a desalination system. This publication proposes a novel method to estimate the net electro-adsorption rate of a CDI cell from a series of low concentration desalination experiments coupled with a one-dimensional electro-adsorption model. In the proposed methodology, a one-dimensional model is presented and two regimes are identified based on the presence or absence of a convection-diffusion layer within the bulk solution, as dictated by the electro-diffusion based Peclet number. For each of these regimes, the net adsorption flux is calculated based on the velocity at which ions are transported toward the electrodes. The proposed model is then solved, first under the assumption of an infinite electrode adsorption capacitance before relaxing this condition, and correlated against the experimental data to assess the global electro-adsorption rate. The analysis in this paper also provides unique physical insight into the macro-scale mass transfer processes that control desalination in CDI. © 2013 The Electrochemical Society. [DOI: 10.1149/2.025303jes] All rights reserved. Manuscript submitted August 20, 2012; revised manuscript received November 5, 2012. Published January 4, 2013. The extraction of dissolved charged particles from relatively low concentration solutions by electro-adsorption methods has gained in
- 4 January 2013
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (3) , E13-E21
Macro Analysis of the Electro-Adsorption Process in Low Concentration NaCl Solutions for Water Desalination Applications
Capacitive deionization (CDI) has become a very attractive desalination technology due to its capability of returning a fraction of the input energy during the regeneration of its adsorbent electrodes. As in any separation technique, analysis of the mass transfer phenomena occurring in this water treatment method is vital to evaluate and extend the performance of a desalination system. This publication proposes a novel method to estimate the net electro-adsorption rate of a CDI cell from a series of low concentration desalination experiments coupled with a one-dimensional electro-adsorption model. In the proposed methodology, a one-dimensional model is presented and two regimes are identified based on the presence or absence of a convection-diffusion layer within the bulk solution, as dictated by the electro-diffusion based Peclet number. For each of these regimes, the net adsorption flux is calculated based on the velocity at which ions are transported toward the electrodes. The proposed model is then solved, first under the assumption of an infinite electrode adsorption capacitance before relaxing this condition, and correlated against the experimental data to assess the global electro-adsorption rate. The analysis in this paper also provides unique physical insight into the macro-scale mass transfer processes that control desalination in CDI. © 2013 The Electrochemical Society. [DOI: 10.1149/2.025303jes] All rights reserved. Manuscript submitted August 20, 2012; revised manuscript received November 5, 2012. Published January 4, 2013. The extraction of dissolved charged particles from relatively low concentration solutions by electro-adsorption methods has gained in
- 17 August 2012
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 296 (2) , 951-956
Measuring the diffusion of noble gases through a porous medium using prompt gamma activation analysis
- 17 August 2012
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 296 (2) , 951-956
Measuring the diffusion of noble gases through a porous medium using prompt gamma activation analysis
- 8 July 2012
- Published by ASME International
- p. 579-587
Characterization of Ion Transport and -Sorption in a Carbon Based Porous Electrode for Desalination Purposes
New and more efficient water desalination technologies have been a topic of incipient research over the past few decades. Although much of the attention and efforts have focused on the improvement of membrane-based desalination methods such as reverse osmosis, the development of new high-surface area carbon-based-electrode materials have brought substantial interest towards capacitive deionization (CDI), a novel technique that uses electric fields to separate the ionic species from the water. Part of the new interest on CDI is its ability to store and return a fraction of the energy used in the desalination process. This characteristic is not common to other electric-field-based desalination methods such as electro-deionization (EDI) and electro-dialysis reversal (EDR) where none of the input energy is recoverable. This paper presents work conducted to analyze the energy recovery, thermodynamic efficiency, and ionic adsorption/desorption rates in a CDI cell using different salt concentration solutions and various flow-rates. Voltage and electrical current measurements are conducted during the desalination and porous electrode regeneration processes and used to evaluate the percentage of energy recovery.. Salinity measurements of the inflow and outflow stream concentrations using conductivity probes, alongside the current measurements, are used to calculate ion adsorption/desorption efficiencies. Correlation of these measurements with an analytical species transport model provides information about the net ionic adsorption/desorption rates in non-saturated-carbon-electrode scenarios. The results show a strong dependence of the net electrical energy requirements with the number of carbon electrodes regeneration cycles. Finally, a non-dimensional number that compares the convective and electro-kinetic transport times is presented. The energy requirements and adsorption/desorption rates analyses conducted for this water-desalination process could be extended to other ion-adsorption applications such as the re-process of spent nuclear fuels in a near future.
- 8 July 2012
- Published by ASME International
- p. 579-587
Characterization of Ion Transport and -Sorption in a Carbon Based Porous Electrode for Desalination Purposes
New and more efficient water desalination technologies have been a topic of incipient research over the past few decades. Although much of the attention and efforts have focused on the improvement of membrane-based desalination methods such as reverse osmosis, the development of new high-surface area carbon-based-electrode materials have brought substantial interest towards capacitive deionization (CDI), a novel technique that uses electric fields to separate the ionic species from the water. Part of the new interest on CDI is its ability to store and return a fraction of the energy used in the desalination process. This characteristic is not common to other electric-field-based desalination methods such as electro-deionization (EDI) and electro-dialysis reversal (EDR) where none of the input energy is recoverable. This paper presents work conducted to analyze the energy recovery, thermodynamic efficiency, and ionic adsorption/desorption rates in a CDI cell using different salt concentration solutions and various flow-rates. Voltage and electrical current measurements are conducted during the desalination and porous electrode regeneration processes and used to evaluate the percentage of energy recovery.. Salinity measurements of the inflow and outflow stream concentrations using conductivity probes, alongside the current measurements, are used to calculate ion adsorption/desorption efficiencies. Correlation of these measurements with an analytical species transport model provides information about the net ionic adsorption/desorption rates in non-saturated-carbon-electrode scenarios. The results show a strong dependence of the net electrical energy requirements with the number of carbon electrodes regeneration cycles. Finally, a non-dimensional number that compares the convective and electro-kinetic transport times is presented. The energy requirements and adsorption/desorption rates analyses conducted for this water-desalination process could be extended to other ion-adsorption applications such as the re-process of spent nuclear fuels in a near future.
- 10 July 2011
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 291 (1) , 261-265
Xenon diffusion studies with prompt gamma activation analysis
- 10 July 2011
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 291 (1) , 261-265
Xenon diffusion studies with prompt gamma activation analysis