Anh Quang Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anh Quang Tran has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Offenhäusser
Forschungszentrum Jülich
3 shared publications - Dirk Mayer
Institute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428, Jülich, Germany
3 shared publications - Duc-Tan Tran
Faculty of Electrical and Electronic Engineering, Phenikaa School of Engineering, Phenikaa University, Hanoi, Vietnam
3 shared publications - Alexey Yakushenko
Institute of Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, 52425 Jülich, Germany
1 shared publication Ali Serpengüzel
Microphotonics Research Laboratory, Department of Physics, Koç University, Rumelifeneri Yolu, Sarıyer, Istanbul 34450, Turkey
1 shared publication- Bernhard Wolfrum
Technical University of Munich
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (6) , 4471-4481
Evaluating random–Nyquist sampling ratios in combined compressed sensing magnetic resonance imaging
Compressed sensing (CS) has been widely applied in magnetic resonance imaging (MRI) to accelerate the image acquisition without significantly reducing its image quality. In Cartesian MRI, acquisition time can be reduced by skipping phase-encoding steps for faster data acquisition. However, the balance between random under-sampling and Nyquist sampling at the k-space center strongly determines image quality. In this study, we systematically evaluate the impact of different random-to-Nyquist sampling ratios for both single-coil (CS-MRI) and multi-coil (CS-pMRI) reconstructions. Simulation results reveal that dense Nyquist sampling around the k-space center is essential for maintaining image fidelity, whereas reconstruction quality deteriorates sharply when random sampling exceeds approximately 60% of the total under-sampled data. Moreover, CS-pMRI consistently outperforms CS-MRI under equivalent under-sampling factors, benefiting from additional coil sensitivity information that improves resilience against aliasing and noise. These findings provide practical guidelines for hybrid under-sampling design, emphasizing that sufficient Nyquist sampling coverage of central k-space is crucial for achieving high-quality reconstructions while enabling high acceleration in CS-MRI.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (6) , 4471-4481
Open AccessEvaluating random–Nyquist sampling ratios in combined compressed sensing magnetic resonance imaging
Compressed sensing (CS) has been widely applied in magnetic resonance imaging (MRI) to accelerate the image acquisition without significantly reducing its image quality. In Cartesian MRI, acquisition time can be reduced by skipping phase-encoding steps for faster data acquisition. However, the balance between random under-sampling and Nyquist sampling at the k-space center strongly determines image quality. In this study, we systematically evaluate the impact of different random-to-Nyquist sampling ratios for both single-coil (CS-MRI) and multi-coil (CS-pMRI) reconstructions. Simulation results reveal that dense Nyquist sampling around the k-space center is essential for maintaining image fidelity, whereas reconstruction quality deteriorates sharply when random sampling exceeds approximately 60% of the total under-sampled data. Moreover, CS-pMRI consistently outperforms CS-MRI under equivalent under-sampling factors, benefiting from additional coil sensitivity information that improves resilience against aliasing and noise. These findings provide practical guidelines for hybrid under-sampling design, emphasizing that sufficient Nyquist sampling coverage of central k-space is crucial for achieving high-quality reconstructions while enabling high acceleration in CS-MRI.
- 19 October 2023
- Published by Springer Nature
- p. 857-867
Fabrication of Ferritin Nanoparticle Patterns for Controlling Neuron Adhesion and Neurite Outgrowth
- 19 October 2023
- Published by Springer Nature
- p. 857-867
Fabrication of Ferritin Nanoparticle Patterns for Controlling Neuron Adhesion and Neurite Outgrowth
- Open Access
- 1 January 2020
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 17 (4) , 4048-4063
MRI Simulation-based evaluation of an efficient under-sampling approach
Compressive sampling (CS) has been commonly employed in the field of magnetic resonance imaging (MRI) to accurately reconstruct sparse and compressive signals. In a MR image, a large amount of encoded information focuses on the origin of the k-space. For the 2D Cartesian K-space MRI, under-sampling the frequency-encoding (kx) dimension does not affect to the acquisition time, thus, only the phase-encoding (ky) dimension can be exploited. In the traditional random under-sampling approach, it acquired Gaussian random measurements along the phaseencoding (ky) in the k-space. In this paper, we proposed a hybrid under-sampling approach; the number of measurements in (ky) is divided into two portions: 70% of the measurements are for random under-sampling and 30% are for definite under-sampling near the origin of the k-space. The numerical simulation consequences pointed out that, in the lower region of the under-sampling ratio r, both the average error and the universal image quality index of the appointed scheme are drastically improved up to 55 and 77% respectively as compared to the traditional scheme. For the first time, instead of using highly computational complexity of many advanced reconstruction techniques, a simple and efficient CS method based simulation is proposed for MRI reconstruction improvement. These findings are very useful for designing new MRI data acquisition approaches for reducing the imaging time of current MRI systems.
- 1 January 2020
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 17 (4) , 4048-4063
Open AccessMRI Simulation-based evaluation of an efficient under-sampling approach
Compressive sampling (CS) has been commonly employed in the field of magnetic resonance imaging (MRI) to accurately reconstruct sparse and compressive signals. In a MR image, a large amount of encoded information focuses on the origin of the k-space. For the 2D Cartesian K-space MRI, under-sampling the frequency-encoding (kx) dimension does not affect to the acquisition time, thus, only the phase-encoding (ky) dimension can be exploited. In the traditional random under-sampling approach, it acquired Gaussian random measurements along the phaseencoding (ky) in the k-space. In this paper, we proposed a hybrid under-sampling approach; the number of measurements in (ky) is divided into two portions: 70% of the measurements are for random under-sampling and 30% are for definite under-sampling near the origin of the k-space. The numerical simulation consequences pointed out that, in the lower region of the under-sampling ratio r, both the average error and the universal image quality index of the appointed scheme are drastically improved up to 55 and 77% respectively as compared to the traditional scheme. For the first time, instead of using highly computational complexity of many advanced reconstruction techniques, a simple and efficient CS method based simulation is proposed for MRI reconstruction improvement. These findings are very useful for designing new MRI data acquisition approaches for reducing the imaging time of current MRI systems.
- 7 September 2017
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 13 (37) , 6297-6303
Observation of chemically protected polydimethylsiloxane: towards crack-free PDMS
The current modification of polydimethylsiloxane (PDMS) substrates via oxygen plasma treatment causes surface cracks. Here, we demonstrate a method to prevent crack formation by chemical treatment. Chemical modification renders the surface hydrophilic for several days and is effective in preserving the elasticity of the PDMS surface at the nanoscale level.
- 7 September 2017
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 13 (37) , 6297-6303
Observation of chemically protected polydimethylsiloxane: towards crack-free PDMS
The current modification of polydimethylsiloxane (PDMS) substrates via oxygen plasma treatment causes surface cracks. Here, we demonstrate a method to prevent crack formation by chemical treatment. Chemical modification renders the surface hydrophilic for several days and is effective in preserving the elasticity of the PDMS surface at the nanoscale level.
- 28 March 2017
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 5 (5) , 1051-1060
Surface coupling strength of gold nanoparticles affects cytotoxicity towards neurons
Weakly bound gold nanoparticles reveal awful toxicity towards neurons.
- 28 March 2017
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 5 (5) , 1051-1060
Surface coupling strength of gold nanoparticles affects cytotoxicity towards neurons
Weakly bound gold nanoparticles reveal awful toxicity towards neurons.
- 27 August 2012
- Published by Wiley in Physica Status Solidi (a)
- Vol. 209 (9) , 1804-1810
Analysis of an optical biosensor based on elastic light scattering from diamond‐, glass‐, and sapphire microspheres
- 27 August 2012
- Published by Wiley in Physica Status Solidi (a)
- Vol. 209 (9) , 1804-1810
Analysis of an optical biosensor based on elastic light scattering from diamond‐, glass‐, and sapphire microspheres
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 193-195
The Overview of Tomographic Algorithms Used in Medical Imaging Equipments
- 1 January 2010
- Published by Springer Nature in IFMBE Proceedings
- p. 193-195
The Overview of Tomographic Algorithms Used in Medical Imaging Equipments