Mariska Margaret Pitoi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mariska Margaret Pitoi has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Miranti Ariyani
Research Unit for Clean Technology, Indonesian Institute of Sciences, Bandung, Indonesia
5 shared publications R Yusiasih
5 shared publicationsT A Koesmawati
Research unit for clean technology, Indonesian Institute of Sciences, Jalan Cisitu 21/154 D, Bandung 40135, Indonesia
5 shared publicationsRetno Yusiasih
National Research and Innovation Agency Indonesian - Research Center for Environmental and Clean Technology, KST Samaun Samadikun, Jl. Sangkuriang, Bandung, 40135, Indonesia
4 shared publicationsM Ariyani
Research unit for clean technology, Indonesian Institute of Sciences, Jalan Cisitu 21/154 D, Bandung 40135, Indonesia
3 shared publicationsA.J. Furness
2 shared publications
Latest Publications
- 4 June 2023
- Published by Elsevier in Chemosphere
- Vol. 335, 139067
Pyrethroid residues in Indonesian river Citarum: A simple analytical method applied for an ecological and human health risk assessment
- 4 June 2023
- Published by Elsevier in Chemosphere
- Vol. 335, 139067
Pyrethroid residues in Indonesian river Citarum: A simple analytical method applied for an ecological and human health risk assessment
- 11 January 2023
- Published by Elsevier in Chemosphere
- Vol. 316, 137817
Chlorination disinfection by-products in Southeast Asia: A review on potential precursor, formation, toxicity assessment, and removal technologies
- 11 January 2023
- Published by Elsevier in Chemosphere
- Vol. 316, 137817
Chlorination disinfection by-products in Southeast Asia: A review on potential precursor, formation, toxicity assessment, and removal technologies
- 10 May 2022
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 27 (4) , 181-193
Pesticide residues in fruits and vegetables in Indonesia: findings of five-year proficiency testing
The first proficiency testing of pesticides in fruits and vegetables in Indonesia is reported. This report covers the findings of five-year proficiency testings. Every year, from 2016 to 2020, 18–25 laboratories join the proficiency testings and analyze 5–11 pesticides in tomato, orange, lettuce, brown rice, strawberry respectively. The number of laboratories participating in the proficiency testings tends to increase, although only 38 % of the laboratories are able to report all pesticides. More than 72 % of participants use QuEChERS or its modifications for sample preparation, all participants use gas chromatography or liquid chromatography for separation, at least 20 % of participants still rely on detectors other than mass spectrophotometer for detection, and 20 %–60 % of participants use matrix-matched calibration for quantification. The performance of laboratories is evaluated as z-score with an average of 90.8 % achieves satisfactory results while 3.3 % and 5.9 % achieve questionable and unsatisfactory results correspondingly. Overall, the performance of laboratory participants during proficiency testings is good. However, improvement is still needed, especially for the number of target pesticides for multi-residue pesticide analysis. Moreover, unsatisfactory z-scores are likely to be resulted from laboratories which use conventional solvent extraction, use detectors other than mass spectrometers, and are not accredited.
- 10 May 2022
- Published by Springer Nature in Accreditation and Quality Assurance
- Vol. 27 (4) , 181-193
Pesticide residues in fruits and vegetables in Indonesia: findings of five-year proficiency testing
The first proficiency testing of pesticides in fruits and vegetables in Indonesia is reported. This report covers the findings of five-year proficiency testings. Every year, from 2016 to 2020, 18–25 laboratories join the proficiency testings and analyze 5–11 pesticides in tomato, orange, lettuce, brown rice, strawberry respectively. The number of laboratories participating in the proficiency testings tends to increase, although only 38 % of the laboratories are able to report all pesticides. More than 72 % of participants use QuEChERS or its modifications for sample preparation, all participants use gas chromatography or liquid chromatography for separation, at least 20 % of participants still rely on detectors other than mass spectrophotometer for detection, and 20 %–60 % of participants use matrix-matched calibration for quantification. The performance of laboratories is evaluated as z-score with an average of 90.8 % achieves satisfactory results while 3.3 % and 5.9 % achieve questionable and unsatisfactory results correspondingly. Overall, the performance of laboratory participants during proficiency testings is good. However, improvement is still needed, especially for the number of target pesticides for multi-residue pesticide analysis. Moreover, unsatisfactory z-scores are likely to be resulted from laboratories which use conventional solvent extraction, use detectors other than mass spectrometers, and are not accredited.
- Open Access
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1)
The optimization of pyrethroid simultaneous analysis in tropical soil of Indonesian tea plantation: Preliminary study
The preliminary study for the simultaneous analysis of five synthetic pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) in tropical soil of tea plantation has been performed. The objective of this study is to perform an optimum condition for simple method development, based on green analytical chemistry. The concentrations of 0.1 μg.g-1 for all pyrethroids were evaluated using ultrasonic and microwave-assisted extraction. The quantification was performed using gas chromatography-electron capture detection (GC-ECD). Based on the experiment, the 0.5 mm soils size particles and 30 minutes sonication times were set as optimal condition for ultrasonic-assisted extraction with the best recovery yields of spiked soils were from 80 to 105 % for each pyrethroid and repeatability represent by the relative standard deviation (RSD, %) ranging of 1.1 – 4.8 %. Results were comparable with those found by microwave-assisted extraction. The result shows that the reproducibility, which is represented by recoveries obtained, ranged from 151 – 276 %, and were unacceptable because the value was beyond the specific range that was proposed by the Association of Analytical Communities (AOAC) International. The ultrasonic-assisted extraction was applicable for pyrethroids analysis in the real sample, with concentration found was 0.01 to 0.12 μg.g−1.
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1)
Open AccessThe optimization of pyrethroid simultaneous analysis in tropical soil of Indonesian tea plantation: Preliminary study
The preliminary study for the simultaneous analysis of five synthetic pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) in tropical soil of tea plantation has been performed. The objective of this study is to perform an optimum condition for simple method development, based on green analytical chemistry. The concentrations of 0.1 μg.g-1 for all pyrethroids were evaluated using ultrasonic and microwave-assisted extraction. The quantification was performed using gas chromatography-electron capture detection (GC-ECD). Based on the experiment, the 0.5 mm soils size particles and 30 minutes sonication times were set as optimal condition for ultrasonic-assisted extraction with the best recovery yields of spiked soils were from 80 to 105 % for each pyrethroid and repeatability represent by the relative standard deviation (RSD, %) ranging of 1.1 – 4.8 %. Results were comparable with those found by microwave-assisted extraction. The result shows that the reproducibility, which is represented by recoveries obtained, ranged from 151 – 276 %, and were unacceptable because the value was beyond the specific range that was proposed by the Association of Analytical Communities (AOAC) International. The ultrasonic-assisted extraction was applicable for pyrethroids analysis in the real sample, with concentration found was 0.01 to 0.12 μg.g−1.
- Open Access
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1)
Comparative study of different sorbents for clean-up for pyrethroid analysis in cocoa powder by GC-ECD: A preliminary study
Three types of solvents and 13 combinations of sorbents were tested to extract pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) from cocoa powder and to remove interferences during clean-up step before being quantified by gas chromatography coupled with electron capture detector (GC-ECD). The result was analysed based on recovery study by spiking the cocoa powder with known amount of targeted pyrethroids. Acetonitrile, methanol, and n-hexane were compared as the solvents and the result showed that acetonitrile is relatively better in extracting pyrethroids. Moreover, 13 treatments, singly or combination of primary secondary amine (PSA), graphitized carbon black (GCB), C18, and florosil, were tested for clean-up step. The clean-up study shows that only combination of PSA and GCB; combination of C18 and Florisil; and combination of GCB and florisil comply the recovery guideline suggested by AOAC and EU, thus are suggested for clean-up for pyrethroid analysis in cocoa powder.
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1)
Open AccessComparative study of different sorbents for clean-up for pyrethroid analysis in cocoa powder by GC-ECD: A preliminary study
Three types of solvents and 13 combinations of sorbents were tested to extract pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) from cocoa powder and to remove interferences during clean-up step before being quantified by gas chromatography coupled with electron capture detector (GC-ECD). The result was analysed based on recovery study by spiking the cocoa powder with known amount of targeted pyrethroids. Acetonitrile, methanol, and n-hexane were compared as the solvents and the result showed that acetonitrile is relatively better in extracting pyrethroids. Moreover, 13 treatments, singly or combination of primary secondary amine (PSA), graphitized carbon black (GCB), C18, and florosil, were tested for clean-up step. The clean-up study shows that only combination of PSA and GCB; combination of C18 and Florisil; and combination of GCB and florisil comply the recovery guideline suggested by AOAC and EU, thus are suggested for clean-up for pyrethroid analysis in cocoa powder.
- Open Access
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1) , 012036
Pyrethroid analysis in fresh tea leaves: preliminary study in building the low volume extraction
Low volume extraction using rotary agitator was used in order to develop method analysis for simultaneous determination of five pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) in fresh tea leaves. The application of n-hexane, n-hexane with some modifications, acetonitrile, and ethyl acetate were tested to extract the pyrethroids before being injected to gas chromatography coupled with electron capture detector. The experiment was conducted in spike-experiment where known amount of pyrethroids were fortified into the fresh tea leaves and the results were compared to the no-spike-experiment where no pyrethroids were added. Result showed that n-hexane was able to extract all target pyrethroids from fresh tea leaves but the recovery values were low. Meanwhile, acetonitrile and ethyl acetate were able to extract pyrethroids with higher recovery values compare to n-hexane but only acetonitrile gave recovery values that were in the range suggested by European Union. Therefore acetonitrile is suggested as a solvent for low volume extraction of pyrethroids from fresh tea leaves.
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 483 (1) , 012036
Open AccessPyrethroid analysis in fresh tea leaves: preliminary study in building the low volume extraction
Low volume extraction using rotary agitator was used in order to develop method analysis for simultaneous determination of five pyrethroids (lambda-cyhalothrin, permethrin, cypermethrin, fenvalerate, and deltamethrin) in fresh tea leaves. The application of n-hexane, n-hexane with some modifications, acetonitrile, and ethyl acetate were tested to extract the pyrethroids before being injected to gas chromatography coupled with electron capture detector. The experiment was conducted in spike-experiment where known amount of pyrethroids were fortified into the fresh tea leaves and the results were compared to the no-spike-experiment where no pyrethroids were added. Result showed that n-hexane was able to extract all target pyrethroids from fresh tea leaves but the recovery values were low. Meanwhile, acetonitrile and ethyl acetate were able to extract pyrethroids with higher recovery values compare to n-hexane but only acetonitrile gave recovery values that were in the range suggested by European Union. Therefore acetonitrile is suggested as a solvent for low volume extraction of pyrethroids from fresh tea leaves.
- Open Access
- 4 September 2019
- Published by Springer Nature in Chemical and Biological Technologies in Agriculture
- Vol. 6 (1) , 1-9
Anthraquinone in Indonesian infusion tea: analysis by HPLC–UV and risk assessment
- 4 September 2019
- Published by Springer Nature in Chemical and Biological Technologies in Agriculture
- Vol. 6 (1) , 1-9
Open AccessAnthraquinone in Indonesian infusion tea: analysis by HPLC–UV and risk assessment
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012019
Low volume liquid-liquid extraction for the determination of benzene, toluene, and xylene in water by GC-FID and HPLC-UV
A simple sample preparation method based on green analytical chemistry was proposed to measure benzene, toluene, and xylene (BTX) in water. The method implemented low volume liquid-liquid extraction for extraction of BTX from water using acetonitrile without any solid phase extraction (SPE) clean-up to cut the chemical consumption during the sample preparation. The quantification of BTX was done by GC-FID and HPLC-UV for comparison. The result showed that the method in combination with GC-FID was able to detect toluene and xylene in spiked water samples below the limit regulated by Ministry of Health of Indonesia (MRL toluene=0.7 mg/L; MRL xylene 0.5 mg/L) but not for benzene (MRL benzene=0.01 mg/L).
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012019
Open AccessLow volume liquid-liquid extraction for the determination of benzene, toluene, and xylene in water by GC-FID and HPLC-UV
A simple sample preparation method based on green analytical chemistry was proposed to measure benzene, toluene, and xylene (BTX) in water. The method implemented low volume liquid-liquid extraction for extraction of BTX from water using acetonitrile without any solid phase extraction (SPE) clean-up to cut the chemical consumption during the sample preparation. The quantification of BTX was done by GC-FID and HPLC-UV for comparison. The result showed that the method in combination with GC-FID was able to detect toluene and xylene in spiked water samples below the limit regulated by Ministry of Health of Indonesia (MRL toluene=0.7 mg/L; MRL xylene 0.5 mg/L) but not for benzene (MRL benzene=0.01 mg/L).
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012020
Preliminary study for 9,10-anthraquinone residue analysis in tea-based functional beverage: GC-ECD optimization and method development
9,10-Anthraquinone, a possible carcinogenic compound, is recently detected above the regulated limit in tea samples sourced from Asian countries. Its occurrence is previously neglected. The European Union has set a limit of 0.02 mg/kg for anthraquinone residue in tea. The available analysis methods for anthraquinone are mostly by gas chromatography (GC) coupled with mass spectrophotometer (MS). This study was aimed to analyse anthraquinone in an infusion of tea-based functional beverage based on low volume liquid-liquid extraction followed by a GC-μECD quantification. The experiment included optimisation of GC-μECD for anthraquinone quantification. The result showed that GC-μECD was able to detect anthraquinone at 1 μg/L with good repeatability showed by %RSD of 6.68. The calibration curve at the range of 1 to 10 μg/L showed good linearity (r=0.9973). The low volume liquid-liquid extraction sample preparation was able to extract anthraquinone from the infusion samples as low as 0.67 μg/L.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012020
Open AccessPreliminary study for 9,10-anthraquinone residue analysis in tea-based functional beverage: GC-ECD optimization and method development
9,10-Anthraquinone, a possible carcinogenic compound, is recently detected above the regulated limit in tea samples sourced from Asian countries. Its occurrence is previously neglected. The European Union has set a limit of 0.02 mg/kg for anthraquinone residue in tea. The available analysis methods for anthraquinone are mostly by gas chromatography (GC) coupled with mass spectrophotometer (MS). This study was aimed to analyse anthraquinone in an infusion of tea-based functional beverage based on low volume liquid-liquid extraction followed by a GC-μECD quantification. The experiment included optimisation of GC-μECD for anthraquinone quantification. The result showed that GC-μECD was able to detect anthraquinone at 1 μg/L with good repeatability showed by %RSD of 6.68. The calibration curve at the range of 1 to 10 μg/L showed good linearity (r=0.9973). The low volume liquid-liquid extraction sample preparation was able to extract anthraquinone from the infusion samples as low as 0.67 μg/L.
- Open Access
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012027
Analytical performance for determination of synthetic pyrethroids residue in Indonesian fermented cocoa using GC-ECD
Pyrethroid insecticides are causing problems for the environment because they are toxic at such small concentrations and very difficult to determine. Characteristics of pyrethroids insecticides include high efficiency, wide spectrum, low biodegradability, and low mammalian and avian toxicity. They also demonstrate strong selectivity for insects and invertebrates. This study presents the results of the analysis conducted on four synthetic pyrethroids in fermented cocoa samples from Indonesia. The pesticides were extracted using acetonitrile and the analysis was carried out by Gas Chromatography with Electron Capture Detector (GC-ECD). Column programming temperature was conducted to get a complete separation. The total operation took less than 10 minutes to separate four standards of synthetic pyrethroids. The synthetic pyrethroids were identified by their retention times and quantified using an external calibration method. The linearity test was carried out for four standard synthetic pyrethroids, namely: lambda-cyhalothrin, permethrin, cypermethrin, and fenvalerate, from 1 μg/kg to 10 μg/kg. The coefficient of correlation (r) was found to be 0.9999; 0.9998; 0.9944; and 0.9999 for lambda-cyhalothrin, permethrin, cypermethrin, and fenvalerate, respectively. The detection limit for synthetic pyrethroids residue was found to be below the EU and Japan regulations, and the method can be applied for the determination of synthetic pyrethroids residues in fermented cocoa.
- 1 May 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 277 (1) , 012027
Open AccessAnalytical performance for determination of synthetic pyrethroids residue in Indonesian fermented cocoa using GC-ECD
Pyrethroid insecticides are causing problems for the environment because they are toxic at such small concentrations and very difficult to determine. Characteristics of pyrethroids insecticides include high efficiency, wide spectrum, low biodegradability, and low mammalian and avian toxicity. They also demonstrate strong selectivity for insects and invertebrates. This study presents the results of the analysis conducted on four synthetic pyrethroids in fermented cocoa samples from Indonesia. The pesticides were extracted using acetonitrile and the analysis was carried out by Gas Chromatography with Electron Capture Detector (GC-ECD). Column programming temperature was conducted to get a complete separation. The total operation took less than 10 minutes to separate four standards of synthetic pyrethroids. The synthetic pyrethroids were identified by their retention times and quantified using an external calibration method. The linearity test was carried out for four standard synthetic pyrethroids, namely: lambda-cyhalothrin, permethrin, cypermethrin, and fenvalerate, from 1 μg/kg to 10 μg/kg. The coefficient of correlation (r) was found to be 0.9999; 0.9998; 0.9944; and 0.9999 for lambda-cyhalothrin, permethrin, cypermethrin, and fenvalerate, respectively. The detection limit for synthetic pyrethroids residue was found to be below the EU and Japan regulations, and the method can be applied for the determination of synthetic pyrethroids residues in fermented cocoa.