Raffaele Aaron Giampaolo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Raffaele Aaron Giampaolo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Rolo
INFN
3 shared publications Angelo Rivetti
Istituto Nazionale di Fisica Nucleare--Sezione di Torino, 10125 Turin, Italy
2 shared publications- Lucio Pancheri
Department of Industrial Engineering, University of Trento, Via Sommarive 9, Povo, 38123 Trento, Italy
2 shared publications Piero Giubilato
Dipartimento di Fisica e Astronomia, Università di Padova, 35131 Padua, Italy, and also with the Istituto Nazionale di Fisica Nucleare-Sezione di Padova, 35131 Padua, Italy
2 shared publications- Thomas Corradino
Dipartimento di Ingegneria Industriale, Università degli studi di Trento, 38123 Trento, Italy
2 shared publications Andrea Di Salvo
Politecnico di Torino, INFN Torino,Torino,Italy
1 shared publication
Latest Publications
- Open Access
Preliminary Characterization of an Active CMOS Pad Detector for Tracking and Dosimetry in HDR Brachytherapy
We assessed the accuracy of a prototype radiation detector with a built in CMOS amplifier for use in dosimetry for high dose rate brachytherapy. The detectors were fabricated on two substrates of epitaxial high resistivity silicon. The radiation detection performance of prototypes has been tested by ion beam induced charge (IBIC) microscopy using a 5.5 MeV alpha particle microbeam. We also carried out the HDR Ir-192 radiation source tracking at different depths and angular dose dependence in a water equivalent phantom. The detectors show sensitivities spanning from (5.8 ± 0.021) × 10−8 to (3.6 ± 0.14) × 10−8 nC Gy−1 mCi−1 mm−2. The depth variation of the dose is within 5% with that calculated by TG-43. Higher discrepancies are recorded for 2 mm and 7 mm depths due to the scattering of secondary particles and the perturbation of the radiation field induced in the ceramic/golden package. Dwell positions and dwell time are reconstructed within ±1 mm and 20 ms, respectively. The prototype detectors provide an unprecedented sensitivity thanks to its monolithic amplification stage. Future investigation of this technology will include the optimisation of the packaging technique.
Open AccessPreliminary Characterization of an Active CMOS Pad Detector for Tracking and Dosimetry in HDR Brachytherapy
We assessed the accuracy of a prototype radiation detector with a built in CMOS amplifier for use in dosimetry for high dose rate brachytherapy. The detectors were fabricated on two substrates of epitaxial high resistivity silicon. The radiation detection performance of prototypes has been tested by ion beam induced charge (IBIC) microscopy using a 5.5 MeV alpha particle microbeam. We also carried out the HDR Ir-192 radiation source tracking at different depths and angular dose dependence in a water equivalent phantom. The detectors show sensitivities spanning from (5.8 ± 0.021) × 10−8 to (3.6 ± 0.14) × 10−8 nC Gy−1 mCi−1 mm−2. The depth variation of the dose is within 5% with that calculated by TG-43. Higher discrepancies are recorded for 2 mm and 7 mm depths due to the scattering of secondary particles and the perturbation of the radiation field induced in the ceramic/golden package. Dwell positions and dwell time are reconstructed within ±1 mm and 20 ms, respectively. The prototype detectors provide an unprecedented sensitivity thanks to its monolithic amplification stage. Future investigation of this technology will include the optimisation of the packaging technique.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (6) , 2393-2399
Fully Depleted MAPS in 110-nm CMOS Process With 100–300-μm Active Substrate
This article presents a fully depleted monolithic active pixel sensor technology compatible with a standard deep submicrometer 110-nm CMOS process. Passive test pixels structures, produced in various flavors, have proved the feasibility of 100- and 300-μm-thick active substrates. Active pixel sensors with monolithically integrated analog and digital electronics, consisting of a 24 x 24 array of pixels with 50-μm pitch, have been shown to be fully functional when operating in the full depletion mode. Characterization results obtained with a proton microbeam and a ⁵⁵Fe radiation source are presented and discussed.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 67 (6) , 2393-2399
Fully Depleted MAPS in 110-nm CMOS Process With 100–300-μm Active Substrate
This article presents a fully depleted monolithic active pixel sensor technology compatible with a standard deep submicrometer 110-nm CMOS process. Passive test pixels structures, produced in various flavors, have proved the feasibility of 100- and 300-μm-thick active substrates. Active pixel sensors with monolithically integrated analog and digital electronics, consisting of a 24 x 24 array of pixels with 50-μm pitch, have been shown to be fully functional when operating in the full depletion mode. Characterization results obtained with a proton microbeam and a ⁵⁵Fe radiation source are presented and discussed.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-517
Depleted MAPS on a 110 nm CMOS CIS Technology
A high-voltage monolithic active pixel sensor, designed to be compatible with standard deep sub-micron CMOS production lines, is described. The device can support a reverse bias voltage of −180 V and combines small collection electrodes with full wafer depletion, demonstrated up to a thickness of $300\ \mu \mathrm{m}$ . Test structures consisting of matrices with an area of $2\ \mathrm{mm} \times 2\ \mathrm{mm}$ embedding 576 pixels with $50\ \mu \mathrm{m}$ pitch have been fabricated in a 110 nm CMOS process. The sensor concept is discussed and experimental measurements obtained on first prototypes are presented.- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 514-517
Depleted MAPS on a 110 nm CMOS CIS Technology
A high-voltage monolithic active pixel sensor, designed to be compatible with standard deep sub-micron CMOS production lines, is described. The device can support a reverse bias voltage of −180 V and combines small collection electrodes with full wafer depletion, demonstrated up to a thickness of $300\ \mu \mathrm{m}$ . Test structures consisting of matrices with an area of $2\ \mathrm{mm} \times 2\ \mathrm{mm}$ embedding 576 pixels with $50\ \mu \mathrm{m}$ pitch have been fabricated in a 110 nm CMOS process. The sensor concept is discussed and experimental measurements obtained on first prototypes are presented.