MSMaria Rosa Sanabria

Maria Rosa Sanabria

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maria Rosa Sanabria has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pathophysiology of Age-Related Macular Degeneration: Implications for Treatment

    by Julián Garcia-Garcia, Ricardo Usategui-Martin, Maria Rosa Sanabria, Esther Fernandez-Perez, Juan Jose Telleria, Rosa M. Coco-Martin

    Age-related macular degeneration (AMD) is a complex, multifactorial, progressive retinal disease that affects millions of people worldwide and has become the leading cause of visual impairment in developed countries. The disease etiopathogenesis is not understood fully, although many triggers and processes that lead to dysfunction and degeneration of the retinal pigment epithelium (RPE) have already been identified. Thus, the lack of cellular control of oxidative stress, altered proteostasis, dysfunction of lipid homeostasis, and mitochondrial dysfunction form an internal feedback loop that causes the RPE to fail and allows accumulation of abnormal misfolded proteins and abnormal lipids that will form drusen. An inadequate antioxidant response, deficits in autophagy mechanisms, and dysregulation of the extracellular matrix (ECM) help to increase the deposition of abnormal drusen material over time. The drusen then act as inflammatory centers that trigger chronic inflammation of the subretinal space in which microglia and recruited macrophages are also involved, and where the complement system is a key component. Choriocapillaris degeneration and nutritional influences are also classic elements recognized in the AMD pathophysiology. The genetic component of the disease is embodied in the recognition of the described risk or protective polymorphisms of some complement and ECM related genes (mainly CFH and ARMS2/HTRA1). Thus, carriers of the risk haplotype at ARMS2/HTRA1 have a higher risk of developing late AMD at a younger age. Finally, gut microbiota and epigenetics may play a role in modulating the progression to advanced AMD with the presence of local inflammatory conditions. Because of multiple implicated processes, different complex combinations of treatments will probably be the best option to obtain the best visual results; they in turn will differ depending on the type and spectrum of disease affecting individual patients or the disease stage in each patient at a specific moment. This will undoubtedly lead to personalized medicine for control and hopefully find a future cure. This necessitates the continued unraveling of all the processes involved in the pathogenesis of AMD that must be understood to devise the combinations of treatments for different concurrent or subsequent problems.


  • Silicone microbubbles after anti‐vascular endothelial growth factor injections in patients with wet age‐related macular degeneration: incidence, quantification and secondary optical coherence tomography artfacts

    by Maria R. Sanabria, Ana M. Alonso‐Tarancón, Paola S. Calles‐Monar, Patricia Ibañez, Santiago García de Arriba, Nuria Alvarez, Jesús A. Piñuel, Rosa M. Coco, Itziar FernánDez

    Purpose: To report the incidence and quantity of silicone oil microbubbles and the relationship with the number of intravitreal anti‐vascular endothelial growth factor (VEGF) injections and evaluate if microbubbles induce artefacts on optical coherence tomography (OCT) images.Methods: Observational, descriptive, cross‐sectional study. Patients with wet age‐related macular degeneration were included who had been treated for 1 year minimally with anti‐VEGF injections repackaged in the hospital pharmacy. Detection and quantification of silicone microbubbles by mydriatic biomicroscopic examination were conducted 1 month after the last injection. The numbers of microbubbles were quantified on a scale of 0–3: 0, none; 1 scarce (1–10 microbubbles); 2 moderate (10–30); or 3 numerous (>30). Shadowing on OCT images was classified as 0–3: 0, none; 1 obscuring some retinal layers; 2 obscuring all retinal layers; or 3 obscuring the retinal thickness.Results: The study included 142 eyes of 98 patients (mean age, 82.4 years + 7.3; range, 65–97) treated with 2377 injections. Microbubbles were detected in 127 (89.4%) eyes, 62 (43.6%) with numerous microbubbles and 36 (25.4%) and 29 (20.4%), respectively, with scarce and moderate numbers. A positive correlation was found between the numbers of injections and intravitreal silicone (rho, 0.7). Optical coherence tomography (OCT) artefacts were detected in 11 eyes; the artefacts obscured all retinal layers in three eyes. No significant relationship could be established between the appearance of floaters and the microbubbles.Conclusion: The presence and number of silicone microbubbles were correlated with the number of intravitreal injections. Microbubbles can produce OCT artefacts, which can hinder the treatment decision.


  • Fluorescein Angiography Indications: Changes after Optical Coherence Tomography and Antiangiogenics

    by Sonia C. Labrador‐Velandia, María R. Sanabria

    SIGNIFICANCE: The present study provides quantitative data regarding the change of indications of fluorescein angiography in a tertiary hospital. Exhaustively compiled data over more than 10 years concerning all the angiographic studies including diagnosis, first‐visit/follow‐up, possible relation with antiangiogenics approval, and optic coherence tomography (OCT) are presented. PURPOSE: The aim of this study was to determine the frequency and indications of fluorescein angiography before and after OCT and anti–vascular endothelial growth factor (anti‐VEGF) treatment implantation. METHODS: This was a retrospective and descriptive study of all fluorescein angiographies performed in a tertiary hospital between 2005 and 2016. Demographic data, diagnosis, follow‐up, and type of angiograms were analyzed in relation with the implantation of time domain OCT (2006), spectral domain OCT (SD‐OCT) (2013), and anti‐VEGF (2007). RESULTS: Of 3263 angiograms (2342 patients) analyzed, 72% were baseline angiograms, and 28% were follow‐up angiograms. After anti‐VEGF initiation, the number of angiograms per year increased progressively with peaks that matched with the approval of anti‐VEGF for wet age‐related macular degeneration (2007) (164.2%), macular edema secondary to retinal vein occlusions (2010) (102.2%), and diabetic macular edema (2011) (123.8%). After using SD‐OCT, fluorescein angiographies decreased up to 57%. CONCLUSIONS: Anti‐VEGF introduction led to an increase in the indication of angiograms, which did not vary significantly after time domain OCT. Nevertheless, since SD‐OCT became available, the indication of fluorescein angiography has halved in the hospital of reference.


  • Open Access

    Predictive models of long-term anatomic outcome in age-related macular degeneration treated with as-needed Ranibizumab

    by Lucia Gonzalez-Buendia, Santiago Delgado-Tirado, M. Rosa Sanabria, Itziar Fernandez, Rosa M. Coco

    To analyze predictors and develop predictive models of anatomic outcome in neovascular age-related macular degeneration (AMD) treated with as-needed ranibizumab after 4 years of follow-up. A multicenter consecutive case series non-interventional study was performed. Clinical, funduscopic and OCT characteristics of 194 treatment-naïve patients with AMD treated with as-needed ranibizumab for at least 2 years and up to 4 years were analyzed at baseline, 3 months and each year until the end of the follow-up. Baseline demographic and angiographic characteristics were also evaluated. R Statistical Software was used for statistical analysis. Main outcome measure was final anatomic status. Factors associated with less probability of preserved macula were diagnosis in 2009, older age, worse vision, presence of atrophy/fibrosis, pigment epithelium detachment, and geographic atrophy/fibrotic scar/neovascular AMD in the fellow eye. Factors associated with higher probability of GA were presence of atrophy and greater number of injections, whereas male sex, worse vision, lesser change in central macular thickness and presence of fibrosis were associated with less probability of GA as final macular status. Predictive model of preserved macula vs. GA/fibrotic scar showed sensibility of 77.78% and specificity of 69.09%. Predictive model of GA vs. fibrotic scar showed sensibility of 68.89% and specificity of 72.22%. We identified predictors of final macular status, and developed two predictive models. Predictive models that we propose are based on easily harvested variables, and, if validated, could be a useful tool for individual patient management and clinical research studies.


  • Open Access

    Loss of Visual Acuity after Successful Surgery for Macula-On Rhegmatogenous Retinal Detachment in a Prospective Multicentre Study

    by Salvatore Di Lauro, Melissa Castrejón, Itziar Fernández, Jimena Rojas, Rosa M. Coco, María R. Sanabria, Enrique Rodríguez de la Rua, J. Carlos Pastor

    Purpose. To quantify the frequency of visual loss after successful retinal detachment (RD) surgery in macula-on patients in a multicentric, prospective series of RD.Methods. Clinical variables from consecutive macula-on RD patients were collected in a prospective multicentric study. Visual loss was defined as at least a reduction in one line in best corrected visual acuity (VA) with Snellen chart. The series were divided into 4 subgroups: (1) all macula-on eyes (n=357); (2) macula-on patients with visual loss at the third month of follow-up (n=53) which were further subdivided in (3) phakic eyes (n=39); and (4) pseudophakic eyes (n=14).Results. Fifty-three eyes (14.9%) had visual loss three months after surgery (n=39phakic eyes;n=14pseudophakic eyes). There were no statistically significant differences between them regarding their clinical characteristics. Pars plana vitrectomy (PPV) was used in 67.2% of cases, scleral buckle in 57.7%, and scleral explant in 11.9% (36.1% were combined procedures).Conclusions. Around 15% of macula-on RD eyes lose VA after successful surgery. Development of cataracts may be one cause in phakic eyes, but vision loss in pseudophakic eyes could have other explanations such as the effect of released factors produced by retinal ischemia on the macula area. Further investigations are necessary to elucidate this hypothesis.


  • Open Access

    Funduscopic results after 4-year follow-up treatment with ranibizumab for age-related macular degeneration in a region of Spain

    by Rosa M Coco, M Rosa Sanabria, Melissa Castrejon, M Isabel Lopez-Galvez, Laura Monje-Fernandez, Marta Fernandez-Munoz, Alejandro Anton, Lourdes de Juan-Marcos, Sonia Villaron-Alvarez, Itziar Fernandez

    The study aims to survey longstanding funduscopic and functional outcomes of age-related macular degeneration (AMD) after ranibizumab treatment and verify the accuracy of a new method to compare the retinal thickness measured with different optical coherence tomography (OCT) tools. Case series included 314 eyes with 2–4 years of follow-up. Main Outcome Measures were visual acuity (VA), number of injections, retinal thickness, OCT morphology, and final macular funduscopic status. One hundred twenty-two men and 177 women (mean age, 78.3 years) were included. The mean time to the first injection was 17.3 ± 14.6 days. Initial VA was O.8(20/125) ± 0.5; 0.7(20/100) ± 0.5 at 3 months; 0.8(20/125) ± 0.5 at a year; 1(20/200) ± 0.6 at year 2; 1(20/200) ± 0.6 at year 3 and 1.1(20/250) ± 0.6 at year 4. Number of visits at 3 months was 2.7 ± 0.8; 7.3 ± 2.1 at a year; 5.2 ± 2.7 along the 2nd year; 3.9 ± 2.3 at year 3 and 3.6 ± 2.2 at year 4. Number of injections at 3 months was 2.6 ± 0.5; 3.9 ± 1.5 at a year; 1.1 ± 1.5 along the 2nd year; 1.5 ± 2.4 at year 3 and 1.8 ± 3.1 at year 4. Patients with worse VA outcomes received more injections and were older. The formula to calculate changes in retinal thickness showed a 30% reduction in thickness, which correlated well with the OCT morphology. Patients with polypoidal choroidal vasculopathy (PCV) had a worse final outcome. The final disciform macular status (37%) was related to fewer injections and a greater decrease in thickness. Final well-preserved maculas (12.%) needed more injections and treatment changes; those that were atrophic at the final visit (30.8%) had a worse initial VA and greater decrease in thickness at the 3-month visit. Younger patients had better final outcomes. Our method to compare retinal thickness using different OCT tools worked well. The final visual outcome after a long follow-up was poor, which may be related to advanced age, poor initial VA, and the high incidence of final fibrosis or atrophy.


  • A New Manual Retinal Thickness Measurement Protocol to Evaluate High Myopia Patients

    by José Alberto De-Lázaro-Yagüe, Alberto López-Miguel, María Rosa Sanabria, Itziar Fernández-Martínez, Rosa María Coco-Martín

    Purpose: To validate a manual measurement protocol for quantifying retinal thickness (RT) using an optical coherence tomography (OCT) device in pathologic myopia patients. Methods: The macular Cross Hair protocol of Stratus OCT3 (Carl Zeiss Meditec, Inc., Dublin, Calif., USA) was applied and manual RT gauging was performed using the caliper tool. Foveal and paramacular RT, located at 1 and 2 mm distances from the fovea in both vertical and horizontal scans, were measured. Three consecutive RT measurements were taken to assess measurement reliability. The within-subject coefficient of variation (CVw) and intraclass correlation coefficients (ICC) were calculated to validate the manual method. Results: The mean axial length of the 29 eyes assessed was 28.28 ± 2.72 mm and the mean spherical refraction was -13.61 ± 6.68 diopters. CVw ranged from 0.86 to 8.73% and ICC varied from 0.81 to 0.98. Conclusion: A manual RT measurement protocol could reliably be used in the daily clinic for assessing pathologic myopic patients when OCT software segmentation fails.


  • Open Access

    Autofluorescence Images with Carl Zeiss versus Topcon Eye Fundus Camera: A Comparative Study

    by Juan M. Muñoz, Rosa M. Coco, M. Rosa Sanabria, Ruben Cuadrado, Eduardo Blanco

    Purpose. To compare the autofluorescence images of the Zeiss versus Topcon eye fundus cameras and design an objective way to quantify it.Procedures. The IMAGEJ software was used to determine the gray level corresponding to the darkest veins and the peripapillary ring (thresholds), the level of white of the brightest perifoveal area, their difference (contrast level), and the suprathreshold area for each photograph.Results. Carl Zeiss has higher contrast values than Topcon. The Topcon contrast presented a crest with further decline as the suprathreshold area continued to increase. On the contrary, the Zeiss profile did not decline in contrast.Conclusions and Message. The Carl Zeiss camera showed superior contrast ability over the Topcon when performing autofluorescence imaging. We set objective parameters to compare fundus cameras FAF images. These parameters could be the base to objectively measure and determine changes and realize followup to areas of hyper- or hypofluorescence.