Oscar Saavedra Villanueva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Oscar Saavedra Villanueva has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Luca Costa
CBS (Centre de Biologie Structurale), Univ Montpellier, CNRS, INSERM, Montpellier, France
3 shared publications - Pierre-Emmanuel Milhiet
Centre for Structural Biology, University of Montpellier, INSERM, CNRS, Montpellier, France
2 shared publications - Thales Fernando Damasceno Fernandes
Universidade Federal de Minas Gerais
2 shared publications - Emmanuel Margeat
Centre de Biologie Structurale (CBS), University of Montpellier, CNRS, INSERM, Montpellier 34090, France
1 shared publication - Francisco Melo
Department of Physics, Universidad de Santiago de Chile 1 Avenida Ecuador 3493, Estación Central, 9170124 Santiago
1 shared publication - Gautier Félix
ICGM, Univ. Montpellier, CNRS, ENSCM, Montpellier, France
1 shared publication
Latest Publications
- 4 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Development of novel correlative AFM-Fluorescent methods for the study of biological samples
Développement de nouvelles approches de microscopie correlative AFM-Fluorescence pour l'analyse d'échantillons biologiques: Les membranes biologiques sont des barrières flexibles qui assurent la perméabilité des cellules, délimitant les frontières cellulaires et les compartiments intracellulaires aux organites à l'intérieur de la cellule. Elles sont composées principalement de phospholipides et de protéines. Ces composants sont les principaux responsables du remodelage des membranes. Ce dernier processus est très dynamique et nécessite une observation à haute résolution latérale et temporelle. Ce travail de thèse s'est concentré sur deux défis principaux dans l'étude des membranes : i) Les propriétés mécaniques. Les membranes sont des matériaux très mous et fragiles, et déterminer leur morphologie réelle est très compliqué en raison de leur mollesse. Nous avons étudié la force maximale exercée par une pointe AFM que les bicouches lipidiques supportées peuvent supporter avant la rupture, ainsi que leur module d'Young, tous deux en fonction de la taille de la pointe. ii) Sensibilité chimique lors de l'imagerie des membranes. L'AFM permet d'obtenir la topographie de la membrane. Cependant, cette technique ne peut pas distinguer la molécule située sous la pointe de l'AFM. Afin de surmonter cet obstacle, nous avons travaillé à la mise au point d'une nouvelle technique de fluorescence à super-résolution combinant l'AFM et les microscopies confocales. Tout d'abord, nous avons mis au point un microscope confocal synchrone et corrélé d'imagerie de fluorescence à vie (FLIM)-AFM. Enfin, nous avons mis au point un dispositif de transfert d'énergie induit par les métaux (MIET)-AFM afin de mesurer simultanément la reconnaissance moléculaire, la topographie et les propriétés mécaniques des échantillons biologiques.
- 4 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Development of novel correlative AFM-Fluorescent methods for the study of biological samples
Développement de nouvelles approches de microscopie correlative AFM-Fluorescence pour l'analyse d'échantillons biologiques: Les membranes biologiques sont des barrières flexibles qui assurent la perméabilité des cellules, délimitant les frontières cellulaires et les compartiments intracellulaires aux organites à l'intérieur de la cellule. Elles sont composées principalement de phospholipides et de protéines. Ces composants sont les principaux responsables du remodelage des membranes. Ce dernier processus est très dynamique et nécessite une observation à haute résolution latérale et temporelle. Ce travail de thèse s'est concentré sur deux défis principaux dans l'étude des membranes : i) Les propriétés mécaniques. Les membranes sont des matériaux très mous et fragiles, et déterminer leur morphologie réelle est très compliqué en raison de leur mollesse. Nous avons étudié la force maximale exercée par une pointe AFM que les bicouches lipidiques supportées peuvent supporter avant la rupture, ainsi que leur module d'Young, tous deux en fonction de la taille de la pointe. ii) Sensibilité chimique lors de l'imagerie des membranes. L'AFM permet d'obtenir la topographie de la membrane. Cependant, cette technique ne peut pas distinguer la molécule située sous la pointe de l'AFM. Afin de surmonter cet obstacle, nous avons travaillé à la mise au point d'une nouvelle technique de fluorescence à super-résolution combinant l'AFM et les microscopies confocales. Tout d'abord, nous avons mis au point un microscope confocal synchrone et corrélé d'imagerie de fluorescence à vie (FLIM)-AFM. Enfin, nous avons mis au point un dispositif de transfert d'énergie induit par les métaux (MIET)-AFM afin de mesurer simultanément la reconnaissance moléculaire, la topographie et les propriétés mécaniques des échantillons biologiques.
- 19 May 2020
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 36 (21) , 5709-5716
Compression, Rupture, and Puncture of Model Membranes at the Molecular Scale
Elastic properties of biological membranes are involved in a large number of membrane functionalities and activities. Conventionally characterized in terms of Young’s modulus, bending stiffness and stretching modulus, membrane mechanics can be assessed at high lateral resolution by means of atomic force microscopy (AFM). Here we show that the mechanical response of biomimetic model systems such as supported lipid bilayers (SLBs) is highly affected by the size of the AFM tip employed as a membrane indenter. Our study is focused on phase-separated fluid-gel lipid membranes at room temperature. In a small tip radius regime (≈ 2 nm) and in the case of fluid phase membranes, we show that the tip can penetrate through the membrane minimizing molecular vertical compression and in absence of molecular membrane rupture. In this case, AFM indentation experiments cannot assess the vertical membrane Young’s modulus. In agreement with the data reported in the literature, in the case of larger indenters (>2 nm) SLBs can be compressed leading to an evaluation of Young’s modulus and membrane maximal withstanding force before rupture. We show that such force increases with the indenter in agreement with the existing theoretical frame. Finally, we demonstrate that the latter has no influence on the number of molecules involved in the rupture process that is observed to be constant and rather dependent on the indenter chemical composition.
- 19 May 2020
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 36 (21) , 5709-5716
Compression, Rupture, and Puncture of Model Membranes at the Molecular Scale
Elastic properties of biological membranes are involved in a large number of membrane functionalities and activities. Conventionally characterized in terms of Young’s modulus, bending stiffness and stretching modulus, membrane mechanics can be assessed at high lateral resolution by means of atomic force microscopy (AFM). Here we show that the mechanical response of biomimetic model systems such as supported lipid bilayers (SLBs) is highly affected by the size of the AFM tip employed as a membrane indenter. Our study is focused on phase-separated fluid-gel lipid membranes at room temperature. In a small tip radius regime (≈ 2 nm) and in the case of fluid phase membranes, we show that the tip can penetrate through the membrane minimizing molecular vertical compression and in absence of molecular membrane rupture. In this case, AFM indentation experiments cannot assess the vertical membrane Young’s modulus. In agreement with the data reported in the literature, in the case of larger indenters (>2 nm) SLBs can be compressed leading to an evaluation of Young’s modulus and membrane maximal withstanding force before rupture. We show that such force increases with the indenter in agreement with the existing theoretical frame. Finally, we demonstrate that the latter has no influence on the number of molecules involved in the rupture process that is observed to be constant and rather dependent on the indenter chemical composition.
- Open Access
- 27 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Synchronous, Crosstalk-free Correlative AFM and Confocal Microscopies/Spectroscopies
Microscopies have become pillars of our characterization tools to observe biological systems and assemblies. Correlative and synchronous use of different microscopies relies on the fundamental assumption of non-interference during images acquisitions. In this work, by exploring the correlative use of Atomic Force Microscopy and confocal-Fluorescence-Lifetime Imaging Microscopy (AFM-FLIM), we quantify cross-talk effects occurring during synchronous acquisition. We characterize and minimize optomechanical forces on different AFM cantilevers interfering with normal AFM operation as well as spurious luminescence from the tip and cantilever affecting time-resolved fluorescence detection. By defining non-interfering experimental imaging parameters, we show accurate real-time acquisition and two-dimensional mapping of interaction force, fluorescence lifetime and intensity characterizing morphology (AFM) and local viscosity (FLIM) of gel and fluid phases separation of supported lipid model membranes. Finally, as proof of principle by means of synchronous force and fluorescence spectroscopies, we precisely tune the lifetime of a fluorescent nanodiamond positioned on the AFM tip by controlling its distance from a metallic surface. This opens up a novel pathway of quench sensing to image soft biological samples such as membranes since it does not require tip-sample mechanical contact in contrast with conventional AFM in liquid.
- 27 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessSynchronous, Crosstalk-free Correlative AFM and Confocal Microscopies/Spectroscopies
Microscopies have become pillars of our characterization tools to observe biological systems and assemblies. Correlative and synchronous use of different microscopies relies on the fundamental assumption of non-interference during images acquisitions. In this work, by exploring the correlative use of Atomic Force Microscopy and confocal-Fluorescence-Lifetime Imaging Microscopy (AFM-FLIM), we quantify cross-talk effects occurring during synchronous acquisition. We characterize and minimize optomechanical forces on different AFM cantilevers interfering with normal AFM operation as well as spurious luminescence from the tip and cantilever affecting time-resolved fluorescence detection. By defining non-interfering experimental imaging parameters, we show accurate real-time acquisition and two-dimensional mapping of interaction force, fluorescence lifetime and intensity characterizing morphology (AFM) and local viscosity (FLIM) of gel and fluid phases separation of supported lipid model membranes. Finally, as proof of principle by means of synchronous force and fluorescence spectroscopies, we precisely tune the lifetime of a fluorescent nanodiamond positioned on the AFM tip by controlling its distance from a metallic surface. This opens up a novel pathway of quench sensing to image soft biological samples such as membranes since it does not require tip-sample mechanical contact in contrast with conventional AFM in liquid.
- 25 February 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (9) , 3660-3664
A simple approach for controlled deposition of Prussian blue analogue nanoparticles on a functionalised plasmonic gold surface
Surface plasmon resonance monitoring of Prussian blue analogue nanoparticles anchored on a gold-cysteamine substrate.
- 25 February 2019
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (9) , 3660-3664
A simple approach for controlled deposition of Prussian blue analogue nanoparticles on a functionalised plasmonic gold surface
Surface plasmon resonance monitoring of Prussian blue analogue nanoparticles anchored on a gold-cysteamine substrate.
- 25 April 2018
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 2 (4) , 043603
Progressive friction mobilization and enhanced Janssen's screening in confined granular rafts
Confined two-dimensional assemblies of floating particles, known as granular rafts, are prone to develop a highly nonlinear response under compression. Here we investigate the transition to the friction-dominated jammed state and map the gradual development of the internal stress profile with flexible pressure sensors distributed along the raft surface. Surprisingly, we observe that the surface stress screening builds up much more slowly than previously thought and that the typical screening distance later dramatically decreases. We explain this behavior in terms of progressive friction mobilization, where the full amplitude of the frictional forces is only reached after a macroscopic local displacement. At further stages of compression, rafts of large length-to-width aspect ratio experience much stronger screenings than the full mobilization limit described by the Janssen's model. We solve this paradox using a simple mathematical analysis and show that such enhanced screening can be attributed to a localized compaction front, essentially shielding the far field from compressive stresses.
- 25 April 2018
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 2 (4) , 043603
Progressive friction mobilization and enhanced Janssen's screening in confined granular rafts
Confined two-dimensional assemblies of floating particles, known as granular rafts, are prone to develop a highly nonlinear response under compression. Here we investigate the transition to the friction-dominated jammed state and map the gradual development of the internal stress profile with flexible pressure sensors distributed along the raft surface. Surprisingly, we observe that the surface stress screening builds up much more slowly than previously thought and that the typical screening distance later dramatically decreases. We explain this behavior in terms of progressive friction mobilization, where the full amplitude of the frictional forces is only reached after a macroscopic local displacement. At further stages of compression, rafts of large length-to-width aspect ratio experience much stronger screenings than the full mobilization limit described by the Janssen's model. We solve this paradox using a simple mathematical analysis and show that such enhanced screening can be attributed to a localized compaction front, essentially shielding the far field from compressive stresses.