Chi-Yu Chuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chi-Yu Chuang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Shinhao Yang
Environmental Sustainability Lab, Natural Science, Center for General Education, CTBC Business School, No. 600, Section 3, Taijiang Boulevard, Annan District, Tainan City 709, Taiwan
7 shared publications - Ying-Fang Hsu
Environmental Sustainability Lab, Natural Science, Center for General Education, CTBC Business School, No. 600, Section 3, Taijiang Boulevard, Annan District, Tainan City 709, Taiwan
6 shared publications - Hsiao-Chien Huang
Environmental Sustainability Lab, Natural Science, Center for General Education, CTBC Business School, No. 600, Section 3, Taijiang Boulevard, Annan District, Tainan City 709, Taiwan
5 shared publications - Chiou-Jong Chen
Department of Occupational Safety and Health, Chang Jung Christian University, Tainan 711, Taiwan
2 shared publications - Chun-Yao Wang
Environmental Sustainability Lab, Center for General Education, CTBC Business School, Tainan 709, Taiwan
2 shared publications - Fu-Tsun Wei
Department of Mathematics, National Central University, Taiwan
2 shared publications
Latest Publications
- Open Access
- 29 June 2026
- Published by MDPI AG in Occupational Health
- Vol. 1 (3) , 27
Occupation-Related Musculoskeletal Disorders Among Watermelon Farmers in Taiwan: A Cross-Sectional Study
This study employed a quantitatively driven mixed-methods approach to investigate crop-specific musculoskeletal disorder (MSD) prevalence and ergonomic risks among Taiwanese watermelon farmers, comparing them with pear (canopy-based) and pineapple (static-stooping) cohorts. A total of 218 participants were recruited (60 watermelon, 60 pear, 63 pineapple, and 35 non-farmers). Structured questionnaires quantified MSD prevalence and ergonomic exposures, while qualitative interviews provided a supportive operational context. Watermelon farmers reported a prominent lower-limb dominant discomfort profile, with a hip/thigh disorder prevalence (36.7%) significantly higher than pear (13.1%) and pineapple (11.1%) farmers. Multivariate logistic regression showed that daily working hours (aOR = 1.38) and uncomfortable posture duration (aOR = 1.33) were independent predictors of hip/thigh disorders. This elevated prevalence may be associated with the combined effects of prolonged deep squatting, dynamic heavy lifting, and unstable sandy terrain. Furthermore, low personal protective equipment adoption was primarily related to environmental incompatibility (sand accumulation and thermal stress). Although the cross-sectional design limits causal inferences, these findings highlight the need for targeted, crop-specific ergonomic interventions, such as breathable, sand-resistant joint supports.
- 29 June 2026
- Published by MDPI AG in Occupational Health
- Vol. 1 (3) , 27
Open AccessOccupation-Related Musculoskeletal Disorders Among Watermelon Farmers in Taiwan: A Cross-Sectional Study
This study employed a quantitatively driven mixed-methods approach to investigate crop-specific musculoskeletal disorder (MSD) prevalence and ergonomic risks among Taiwanese watermelon farmers, comparing them with pear (canopy-based) and pineapple (static-stooping) cohorts. A total of 218 participants were recruited (60 watermelon, 60 pear, 63 pineapple, and 35 non-farmers). Structured questionnaires quantified MSD prevalence and ergonomic exposures, while qualitative interviews provided a supportive operational context. Watermelon farmers reported a prominent lower-limb dominant discomfort profile, with a hip/thigh disorder prevalence (36.7%) significantly higher than pear (13.1%) and pineapple (11.1%) farmers. Multivariate logistic regression showed that daily working hours (aOR = 1.38) and uncomfortable posture duration (aOR = 1.33) were independent predictors of hip/thigh disorders. This elevated prevalence may be associated with the combined effects of prolonged deep squatting, dynamic heavy lifting, and unstable sandy terrain. Furthermore, low personal protective equipment adoption was primarily related to environmental incompatibility (sand accumulation and thermal stress). Although the cross-sectional design limits causal inferences, these findings highlight the need for targeted, crop-specific ergonomic interventions, such as breathable, sand-resistant joint supports.
- Open Access
Inactivation of Bacterial and Viral Bioaerosols by Lactoferricin B-Coated Filters Under Various Environmental Conditions
Conventional antimicrobial air filters often conflate physical interception with true biochemical inactivation, posing secondary aerosolization risks during maintenance. This study developed a lactoferricin B-functionalized polypropylene (LfCF) filter to provide a dual-action mechanism: electrostatic capture and robust contact-killing against bioaerosols. To rigorously decouple these mechanisms, a polyallylamine binder-only (PP+PAA) control was incorporated. Dynamic penetration assays at 10 cm/s revealed that the 2.0 mg LfCF achieved significantly lower viable penetration rates for Escherichia coli (41.2%) and λ phage (46.0%) compared to the PP+PAA control (75.1% and 76.3%). This substantial gap demonstrates instantaneous sublethal injury upon aerodynamic impaction, defined here as “dynamic inactivation.” Crucially, time-dependent elution assays confirmed a >2 log reduction in viable counts for both retained E. coli and λ phage on LfCFs within 60 min, definitively validating its genuine contact-killing capability. Furthermore, the amphipathic lactoferricin B peptide maintained exceptional biocidal efficacy even under high-humidity conditions (70% RH), overcoming the electrostatic shielding typical of traditional biopolymers, without increasing aerodynamic pressure drop. Finally, field validation in a dental clinic demonstrated an 83.3% reduction in airborne viable bioaerosols. As a passive, self-sterilizing engineering control, the LfCF offers a highly reliable intervention for mitigating occupational bioaerosol exposures.
Open AccessInactivation of Bacterial and Viral Bioaerosols by Lactoferricin B-Coated Filters Under Various Environmental Conditions
Conventional antimicrobial air filters often conflate physical interception with true biochemical inactivation, posing secondary aerosolization risks during maintenance. This study developed a lactoferricin B-functionalized polypropylene (LfCF) filter to provide a dual-action mechanism: electrostatic capture and robust contact-killing against bioaerosols. To rigorously decouple these mechanisms, a polyallylamine binder-only (PP+PAA) control was incorporated. Dynamic penetration assays at 10 cm/s revealed that the 2.0 mg LfCF achieved significantly lower viable penetration rates for Escherichia coli (41.2%) and λ phage (46.0%) compared to the PP+PAA control (75.1% and 76.3%). This substantial gap demonstrates instantaneous sublethal injury upon aerodynamic impaction, defined here as “dynamic inactivation.” Crucially, time-dependent elution assays confirmed a >2 log reduction in viable counts for both retained E. coli and λ phage on LfCFs within 60 min, definitively validating its genuine contact-killing capability. Furthermore, the amphipathic lactoferricin B peptide maintained exceptional biocidal efficacy even under high-humidity conditions (70% RH), overcoming the electrostatic shielding typical of traditional biopolymers, without increasing aerodynamic pressure drop. Finally, field validation in a dental clinic demonstrated an 83.3% reduction in airborne viable bioaerosols. As a passive, self-sterilizing engineering control, the LfCF offers a highly reliable intervention for mitigating occupational bioaerosol exposures.
- Open Access
- 9 February 2026
- Published by MDPI AG in Preprints.org
Inactivation of Bacterial and Viral Bioaerosols by Lactoferrin-Coated Filters under Various Environmental Conditions
Accumulation of viable bioaerosols on air filters poses significant occupational health risks, particularly regarding secondary aerosolization during maintenance in high-density indoor environments. To address this challenge, this study developed a bovine lactoferrin-functionalized polypropylene (LfCF) filter as an active engineering control intervention. The filtration performance was evaluated against E. coli and phage virus under varying environmental conditions. Results demonstrated broad-spectrum inactivation efficacy, with the 2.0 mg coating achieving optimal performance in a dose-dependent manner. Crucially, the lactoferrin coating exhibited superior environmental stability; unlike traditional biopolymers (e.g., chitosan), its antimicrobial efficiency remained consistent across 30–70% relative humidity (RH), ensuring reliability in damp HVAC systems. To validate realistic use scenarios, a field test was conducted in a dental clinic waiting area, achieving an ~83% reduction in airborne bacteria. This study positions LfCFs as a robust, “Safe-by-Design” solution for mitigating bioaerosol exposure and enhancing occupational safety in healthcare and public facilities.
- 9 February 2026
- Published by MDPI AG in Preprints.org
Open AccessInactivation of Bacterial and Viral Bioaerosols by Lactoferrin-Coated Filters under Various Environmental Conditions
Accumulation of viable bioaerosols on air filters poses significant occupational health risks, particularly regarding secondary aerosolization during maintenance in high-density indoor environments. To address this challenge, this study developed a bovine lactoferrin-functionalized polypropylene (LfCF) filter as an active engineering control intervention. The filtration performance was evaluated against E. coli and phage virus under varying environmental conditions. Results demonstrated broad-spectrum inactivation efficacy, with the 2.0 mg coating achieving optimal performance in a dose-dependent manner. Crucially, the lactoferrin coating exhibited superior environmental stability; unlike traditional biopolymers (e.g., chitosan), its antimicrobial efficiency remained consistent across 30–70% relative humidity (RH), ensuring reliability in damp HVAC systems. To validate realistic use scenarios, a field test was conducted in a dental clinic waiting area, achieving an ~83% reduction in airborne bacteria. This study positions LfCFs as a robust, “Safe-by-Design” solution for mitigating bioaerosol exposure and enhancing occupational safety in healthcare and public facilities.
- Open Access
- 5 July 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (10) , 105528
Contribution of greenhouse gas footprint of broiler product during electrical slaughtering in Taiwan
- 5 July 2025
- Published by Elsevier in Poultry Science
- Vol. 104 (10) , 105528
Open AccessContribution of greenhouse gas footprint of broiler product during electrical slaughtering in Taiwan
- Open Access
- 30 October 2023
- Published by MDPI AG in Aerobiology
- Vol. 1 (2) , 70-81
Inactivation of Avian Influenza Virus Aerosol Using Membrane-Less Electrolyzed Water Spraying
Avian influenza virus (AIV) can have a serious impact on both human and animal health. In this study, we used an environmentally controlled chamber and a hemagglutination assay (HA) to evaluate the ability of membrane-less electrolyzed water (MLEW) spraying to inactivate H6N1 AIV aerosol. MLEW was generated by electrolyzing sodium chloride solution, and then sprayed into the chamber at free available chlorine (FAC) concentrations of 50, 100 and 200 mg/L by means of high-pressure air pumping to inactivate airborne H6N1 AIV aerosols individually. The results showed that MLEW spraying effectively neutralized H6N1 AIV aerosol. In addition, the virucidal ability of MLEW increased as the FAC concentration increased. Five minutes after MLEW spraying at an FAC concentration of 200 mg/L, the H6N1 viral HA titer decreased from 24 to 20. Our work provides important new evidence of the value of spraying with MLEW disinfectant to protect against AIV, which may be further applied for indoor decontamination purposes to promote animal and human health.
- 30 October 2023
- Published by MDPI AG in Aerobiology
- Vol. 1 (2) , 70-81
Open AccessInactivation of Avian Influenza Virus Aerosol Using Membrane-Less Electrolyzed Water Spraying
Avian influenza virus (AIV) can have a serious impact on both human and animal health. In this study, we used an environmentally controlled chamber and a hemagglutination assay (HA) to evaluate the ability of membrane-less electrolyzed water (MLEW) spraying to inactivate H6N1 AIV aerosol. MLEW was generated by electrolyzing sodium chloride solution, and then sprayed into the chamber at free available chlorine (FAC) concentrations of 50, 100 and 200 mg/L by means of high-pressure air pumping to inactivate airborne H6N1 AIV aerosols individually. The results showed that MLEW spraying effectively neutralized H6N1 AIV aerosol. In addition, the virucidal ability of MLEW increased as the FAC concentration increased. Five minutes after MLEW spraying at an FAC concentration of 200 mg/L, the H6N1 viral HA titer decreased from 24 to 20. Our work provides important new evidence of the value of spraying with MLEW disinfectant to protect against AIV, which may be further applied for indoor decontamination purposes to promote animal and human health.
- Open Access
The Impact of Harvesting Height on Farmers’ Musculoskeletal Tissue
This study aimed to examine whether different agricultural work patterns may cause MSDs in different body areas and assess their severity. In previous studies, musculoskeletal disorders (MSDs) have been recognized as an occupational disease in agricultural workers. However, not all MSDs resulting from agriculture occur in the same body areas or have similar severity. This study conducted a questionnaire survey to inquire about the body areas and severity of MSDs among fruit farmers. A total of 212 valid answers were collected. Subsequently, their main harvesting postures were classified into three groups to examine the differences in MSD occurrence and severity among those groups. The results indicate that the harvesting posture did result in different severities of MSDs in certain body areas. Raising hands above the shoulders caused significantly higher MSD severity in the neck, shoulder, upper back, and elbows despite the same standing posture. Additionally, those who squatted, bent, or kneeled had a significantly higher severity of MSDs in the shoulders compared to those who stood but did not raise their hands above their shoulders. This study confirmed that the different harvesting heights of fruits can affect farmers’ posture, leading to differences in the body areas affected by, and severity of, MSDs.
Open AccessThe Impact of Harvesting Height on Farmers’ Musculoskeletal Tissue
This study aimed to examine whether different agricultural work patterns may cause MSDs in different body areas and assess their severity. In previous studies, musculoskeletal disorders (MSDs) have been recognized as an occupational disease in agricultural workers. However, not all MSDs resulting from agriculture occur in the same body areas or have similar severity. This study conducted a questionnaire survey to inquire about the body areas and severity of MSDs among fruit farmers. A total of 212 valid answers were collected. Subsequently, their main harvesting postures were classified into three groups to examine the differences in MSD occurrence and severity among those groups. The results indicate that the harvesting posture did result in different severities of MSDs in certain body areas. Raising hands above the shoulders caused significantly higher MSD severity in the neck, shoulder, upper back, and elbows despite the same standing posture. Additionally, those who squatted, bent, or kneeled had a significantly higher severity of MSDs in the shoulders compared to those who stood but did not raise their hands above their shoulders. This study confirmed that the different harvesting heights of fruits can affect farmers’ posture, leading to differences in the body areas affected by, and severity of, MSDs.
- Open Access
Evaluation of the Inactivating Ability of Carbon-Nanotube Coated Plasma Treatment on Bioaerosols for Indoor Air Cleaning
This work considers the ability of carbon-nanotube (CNT)-coated plasma to inactivate bioaerosols. Escherichia coli (E. coli) and λ virus phage were chosen as the challenge bioaerosols. A test chamber was used to simulate an indoor environment and to control the air exchange rate (ACH). The results demonstrated that CNT-coated plasma had a significant antimicrobial effect on both bacterial and viral bioaerosols. The experimental results revealed that CNT-coated plasma under an operating voltage of 6.0 kV and an ACH of 0.5 h−1 had significantly higher bioaerosol inactivating ability (kCNT, 0.24 and 0.23 min−1 for E. coli and λ virus phage, respectively) compared to the results without using CNT-coated plasma (kn, 0.09 and 0.08 min−1 for E. coli and λ virus phage, respectively). Under the higher ACH condition, the system demonstrated higher bioaerosol removal efficiency due to the mechanical effect of clean air exchange. Increasing flow rate and operating voltage could raise the inactivating ability of the CNT-coated plasma system. A CNT-coated plasma air-cleaning device was tested in a real indoor medical environment and yielded bacterial bioaerosol removal efficiency in the range from 70% to 80% within 6 h of operation (7.5 Lpm and 6.0 kV), which suggests that CNT-coated plasma treatment has the potential for further application in improving indoor air quality.
Open AccessEvaluation of the Inactivating Ability of Carbon-Nanotube Coated Plasma Treatment on Bioaerosols for Indoor Air Cleaning
This work considers the ability of carbon-nanotube (CNT)-coated plasma to inactivate bioaerosols. Escherichia coli (E. coli) and λ virus phage were chosen as the challenge bioaerosols. A test chamber was used to simulate an indoor environment and to control the air exchange rate (ACH). The results demonstrated that CNT-coated plasma had a significant antimicrobial effect on both bacterial and viral bioaerosols. The experimental results revealed that CNT-coated plasma under an operating voltage of 6.0 kV and an ACH of 0.5 h−1 had significantly higher bioaerosol inactivating ability (kCNT, 0.24 and 0.23 min−1 for E. coli and λ virus phage, respectively) compared to the results without using CNT-coated plasma (kn, 0.09 and 0.08 min−1 for E. coli and λ virus phage, respectively). Under the higher ACH condition, the system demonstrated higher bioaerosol removal efficiency due to the mechanical effect of clean air exchange. Increasing flow rate and operating voltage could raise the inactivating ability of the CNT-coated plasma system. A CNT-coated plasma air-cleaning device was tested in a real indoor medical environment and yielded bacterial bioaerosol removal efficiency in the range from 70% to 80% within 6 h of operation (7.5 Lpm and 6.0 kV), which suggests that CNT-coated plasma treatment has the potential for further application in improving indoor air quality.
- Open Access
- 5 July 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (13) , 7183
Evaluation of the Bioaerosol Inactivation Ability of Chitosan-Coated Antimicrobial Filters
This work considers the enhancement of indoor bioaerosol removal efficiency by liquid coating of the antimicrobial agent chitosan onto polypropylene fibrous filters (CCFs). Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis) were chosen as the tested bioaerosols. The results revealed that 2.5% (w/w) of CCFs have significantly higher bioaerosol survival capability (23% and 34% of E. coli and B. subtilis, respectively), compared to an untreated filter (65% and 64% for E. coli and B. subtilis, respectively). Increasing face velocity and relative humidity during operating CCFs could reduce the bioaerosol removal capability. The regression analysis of the experimental findings demonstrated that the higher coating concentration of chitosan had the most positive influence on bioaerosol removal, while the face velocity and relative humidity had a negative influence, but a milder effect was observed (R2 = 0.83 and 0.81 for E. coli and B. subtilis bioaerosols, respectively). A CCF-loaded air-cleaning device was tested in a real indoor environment and resulted in 80.1% bioaerosol removal within 3 h of operating, which suggests that the chitosan-coated filter has the potential for further application in improving indoor air quality in the future.
- 5 July 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (13) , 7183
Open AccessEvaluation of the Bioaerosol Inactivation Ability of Chitosan-Coated Antimicrobial Filters
This work considers the enhancement of indoor bioaerosol removal efficiency by liquid coating of the antimicrobial agent chitosan onto polypropylene fibrous filters (CCFs). Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis) were chosen as the tested bioaerosols. The results revealed that 2.5% (w/w) of CCFs have significantly higher bioaerosol survival capability (23% and 34% of E. coli and B. subtilis, respectively), compared to an untreated filter (65% and 64% for E. coli and B. subtilis, respectively). Increasing face velocity and relative humidity during operating CCFs could reduce the bioaerosol removal capability. The regression analysis of the experimental findings demonstrated that the higher coating concentration of chitosan had the most positive influence on bioaerosol removal, while the face velocity and relative humidity had a negative influence, but a milder effect was observed (R2 = 0.83 and 0.81 for E. coli and B. subtilis bioaerosols, respectively). A CCF-loaded air-cleaning device was tested in a real indoor environment and resulted in 80.1% bioaerosol removal within 3 h of operating, which suggests that the chitosan-coated filter has the potential for further application in improving indoor air quality in the future.
- Open Access
- 25 April 2018
- Published by American Mathematical Society (AMS) in Transactions of the American Mathematical Society
- Vol. 371 (1) , 173-198
Waldspurger formula over function fields
In this paper, we derive a function field version of the Waldspurger formula for the central critical values of the Rankin-Selberg $L$-functions. This formula states that the central critical $L$-values in question can be expressed as the “ratio” of the global toric period integral to the product of the local toric period integrals. Consequently, this result provides a necessary and sufficient criterion for the non-vanishing of these central critical $L$-values, and supports the Gross-Prasad conjecture for $\mathrm {SO}(3)$ over function fields.- 25 April 2018
- Published by American Mathematical Society (AMS) in Transactions of the American Mathematical Society
- Vol. 371 (1) , 173-198
Open AccessWaldspurger formula over function fields
In this paper, we derive a function field version of the Waldspurger formula for the central critical values of the Rankin-Selberg $L$-functions. This formula states that the central critical $L$-values in question can be expressed as the “ratio” of the global toric period integral to the product of the local toric period integrals. Consequently, this result provides a necessary and sufficient criterion for the non-vanishing of these central critical $L$-values, and supports the Gross-Prasad conjecture for $\mathrm {SO}(3)$ over function fields. - 18 January 2017
- Published by Wiley in Proceedings of the London Mathematical Society
- Vol. 114 (2) , 333-373
On central critical values of Rankin-type L-functions over global function fields
- 18 January 2017
- Published by Wiley in Proceedings of the London Mathematical Society
- Vol. 114 (2) , 333-373
On central critical values of Rankin-type L-functions over global function fields