Andrew Meyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrew Meyer has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Martin Roche
Hospital for Special Surgery Florida
1 shared publication - Matthias A. Verstraete
EnMovi Ltd., Unit 1I, Inovo Building, 121 George St., Glasgow G1 1RD, UK
1 shared publication - Michael A. Conditt
OrthoSensor Inc., Dania Beach, FL 33004, USA
1 shared publication - Paul B. Jacob
Oklahoma Joint Reconstruction Institute, Oklahoma City, Oklahoma
1 shared publication - Ricardo Antunes
EnMovi Ltd., Unit 1I, Inovo Building, 121 George St., Glasgow G1 1RD, UK
1 shared publication
Latest Publications
- Open Access
- 5 July 2021
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 6 (3) , 60
Accuracy of Measuring Knee Flexion after TKA through Wearable IMU Sensors
Wearable sensors have the potential to facilitate remote monitoring for patients recovering from knee replacement surgery. Using IMU sensors attached to the patients’ leg, knee flexion can be monitored while the patients are recovering in their home environment. Ideally, these flexion angle measurements will have an accuracy and repeatability at least on par with current clinical standards. To validate the clinical accuracy of a two-sensor IMU system, knee flexion angles were measured in eight subjects post-TKA and compared with other in-clinic angle measurement techniques. These sensors are aligned to the patients’ anatomy by taking a pose resting their operated leg on a box; an initial goniometer measurement defines the patients’ knee flexion while taking that pose. The repeatability and accuracy of the system was subsequently evaluated by comparing knee flexion angles against goniometer readings and markerless optical motion capture data. The alignment pose was repeatable with a mean absolute error of 1.6 degrees. The sensor accuracy through the range of motion had a mean absolute error of 2.6 degrees. In conclusion, the presented sensor system facilitates a repeatable and accurate measurement of the knee flexion, holding the potential for effective remote monitoring of patients recovering from knee replacement surgery.
- 5 July 2021
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 6 (3) , 60
Open AccessAccuracy of Measuring Knee Flexion after TKA through Wearable IMU Sensors
Wearable sensors have the potential to facilitate remote monitoring for patients recovering from knee replacement surgery. Using IMU sensors attached to the patients’ leg, knee flexion can be monitored while the patients are recovering in their home environment. Ideally, these flexion angle measurements will have an accuracy and repeatability at least on par with current clinical standards. To validate the clinical accuracy of a two-sensor IMU system, knee flexion angles were measured in eight subjects post-TKA and compared with other in-clinic angle measurement techniques. These sensors are aligned to the patients’ anatomy by taking a pose resting their operated leg on a box; an initial goniometer measurement defines the patients’ knee flexion while taking that pose. The repeatability and accuracy of the system was subsequently evaluated by comparing knee flexion angles against goniometer readings and markerless optical motion capture data. The alignment pose was repeatable with a mean absolute error of 1.6 degrees. The sensor accuracy through the range of motion had a mean absolute error of 2.6 degrees. In conclusion, the presented sensor system facilitates a repeatable and accurate measurement of the knee flexion, holding the potential for effective remote monitoring of patients recovering from knee replacement surgery.