Martyna Grodzicka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martyna Grodzicka has a total of 208 co-authors. Here are the top co-authors by number of shared publications:
- T. Szczesniak
National Centre for Nuclear Research, 05-400 Otwock, Poland
55 shared publications - Marek Moszynski
National Centre for Nuclear Research (NCBJ), Otwock, 05-400 poland
51 shared publications - Lukasz Swiderski
National Centre for Nuclear Research, 05-400 Otwock, Poland
22 shared publications D. Wolski
15 shared publicationsJ. Baszak
13 shared publicationsM. Szawlowski
National Centre for Nuclear Research, Otwock-Swierk, PL 05-400, Poland
10 shared publications
Latest Publications
- Open Access
Studies of the Modular COsmic Ray Detector (MCORD) Using an Automatic Temperature Control Loop to Maintain Constant Gain Parameters of Semiconductor SiPM Photomultipliers
The Modular Cosmic Ray Detector (MCORD) is a modular scintillator-based system employing silicon photomultipliers (SiPMs) and FPGA-based digital signal processing, designed for applications such as cosmic muon detection, veto systems, and detector calibration support. In this work, we investigate the influence of ambient temperature variations on detector performance, with particular emphasis on SiPM gain stability. Several automatic temperature compensation loops were implemented to stabilize the operating voltage of the sensors. Based on controlled laboratory measurements, we evaluate the effectiveness of different control strategies, including variations in temperature averaging time and threshold response criteria. The performance of each approach is compared in terms of gain stability and response dynamics. We identify the optimal temperature control configuration for planned MCORD measurements and present recent modifications to the detector electronics, including updated software for Analog Front End (AFE) control. Additionally, we describe modifications made to the detector’s electronics since the previous publication, including new software developed to control AFE electronics.
Open AccessStudies of the Modular COsmic Ray Detector (MCORD) Using an Automatic Temperature Control Loop to Maintain Constant Gain Parameters of Semiconductor SiPM Photomultipliers
The Modular Cosmic Ray Detector (MCORD) is a modular scintillator-based system employing silicon photomultipliers (SiPMs) and FPGA-based digital signal processing, designed for applications such as cosmic muon detection, veto systems, and detector calibration support. In this work, we investigate the influence of ambient temperature variations on detector performance, with particular emphasis on SiPM gain stability. Several automatic temperature compensation loops were implemented to stabilize the operating voltage of the sensors. Based on controlled laboratory measurements, we evaluate the effectiveness of different control strategies, including variations in temperature averaging time and threshold response criteria. The performance of each approach is compared in terms of gain stability and response dynamics. We identify the optimal temperature control configuration for planned MCORD measurements and present recent modifications to the detector electronics, including updated software for Analog Front End (AFE) control. Additionally, we describe modifications made to the detector’s electronics since the previous publication, including new software developed to control AFE electronics.
- Open Access
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03049
Characterization of EJ-250, Li-loaded plastic scintillator for simultaneous discrimination of gamma rays, slow and fast neutrons
In this work, the pulse shape discrimination (PSD) capability for gamma rays as well as fast and thermal neutrons of EJ-250 lithium-loaded plastic scintillator is investigated and compared with that of EJ-270 lithium-loaded plastic scintillator and EJ-309B5 boron-doped liquid scintillator. Measurements were performed in a mixed neutron-gamma radiation field generated by an intense PuBe source (∼ 10 6 neutrons·s -1 · 4 π -1). To enhance the detection efficiency for thermal and epithermal neutrons, the neutron source was embedded in an 18 cm diameter paraffin moderator.The study addresses neutron-gamma discrimination performance, photoelectron yield, and detailed analysis of scintillation pulse shapes associated with gamma rays, thermal neutrons, and fast neutrons. Pulse shape analysis was employed to provide deeper insight into the detector response mechanisms to different types of radiation interactions and their impact on signal separation efficiency in a mixed radiation field. The results show that while all investigated scintillators exhibit pulse shape discrimination capability, the EJ-250 scintillator offers the most promising overall performance as a homogeneous detector for simultaneous discrimination of gamma rays, fast neutrons, and thermal neutrons.
- 1 March 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (03) , P03049
Open AccessCharacterization of EJ-250, Li-loaded plastic scintillator for simultaneous discrimination of gamma rays, slow and fast neutrons
In this work, the pulse shape discrimination (PSD) capability for gamma rays as well as fast and thermal neutrons of EJ-250 lithium-loaded plastic scintillator is investigated and compared with that of EJ-270 lithium-loaded plastic scintillator and EJ-309B5 boron-doped liquid scintillator. Measurements were performed in a mixed neutron-gamma radiation field generated by an intense PuBe source (∼ 10 6 neutrons·s -1 · 4 π -1). To enhance the detection efficiency for thermal and epithermal neutrons, the neutron source was embedded in an 18 cm diameter paraffin moderator.The study addresses neutron-gamma discrimination performance, photoelectron yield, and detailed analysis of scintillation pulse shapes associated with gamma rays, thermal neutrons, and fast neutrons. Pulse shape analysis was employed to provide deeper insight into the detector response mechanisms to different types of radiation interactions and their impact on signal separation efficiency in a mixed radiation field. The results show that while all investigated scintillators exhibit pulse shape discrimination capability, the EJ-250 scintillator offers the most promising overall performance as a homogeneous detector for simultaneous discrimination of gamma rays, fast neutrons, and thermal neutrons.
- Open Access
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 661-666
Experiment Details in Time Resolution Measurements of LYSO Scintillator
In this research, we have performed experimental measurements of coincidence time resolution with a custom-built testbench. In the scope of this work, we discussed technical issues and data validation in the CTR experiment on an example of Saint-Gobain 4 x 4 x 4 mm lutetium-yttrium oxyorthosilicate (LYSO) crystals. The primary objective of the presented experimental works is to develop instruments for the experimental validation of newly created scintillation materials, as a step toward way the 10-ps time-of-flight PET challenge.
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 661-666
Open AccessExperiment Details in Time Resolution Measurements of LYSO Scintillator
In this research, we have performed experimental measurements of coincidence time resolution with a custom-built testbench. In the scope of this work, we discussed technical issues and data validation in the CTR experiment on an example of Saint-Gobain 4 x 4 x 4 mm lutetium-yttrium oxyorthosilicate (LYSO) crystals. The primary objective of the presented experimental works is to develop instruments for the experimental validation of newly created scintillation materials, as a step toward way the 10-ps time-of-flight PET challenge.
- 30 September 2021
- Published by Taylor & Francis
- p. 225-256
Silicon Photomultipliers in Scintillation Detectors for Nuclear Medicine
In the first part of this chapter different characteristics of silicon photomultipliers (SiPMs), which affect the use of SiPMs in medical instrumentation, are reviewed. It covers a gain of SiPM, excess noise factor (ENF), photon detection efficiency (PDE), after-pulses, crosstalk, dark noise, and a linearity of the response. In the second part, a summary of timing studies with SiPMs in scintillation detection is presented. It covers results of tests of transit time spread at single photon detection and the best reported time resolution in a fast timing with 511 keV annihilation quanta, on the way to time-of-flight positron emission tomography (PET) scanners. Next, various tests reported for a combination of SiPM arrays of different size coupled to different scintillators used in gamma spectrometry, like NaI(Tl), BGO, LaBr3, and LYSO are reviewed, including tests of 3″ × 3″ LaBr3:Ce and its co-doped version. Besides of the characterization of different SiPMs in scintillation detection some examples of the most modern medical instrumentation are presented including the newest Siemens Biograph Vision PET/CT scanner and the uExplorer whole body PET scanner.
- 30 September 2021
- Published by Taylor & Francis
- p. 225-256
Silicon Photomultipliers in Scintillation Detectors for Nuclear Medicine
In the first part of this chapter different characteristics of silicon photomultipliers (SiPMs), which affect the use of SiPMs in medical instrumentation, are reviewed. It covers a gain of SiPM, excess noise factor (ENF), photon detection efficiency (PDE), after-pulses, crosstalk, dark noise, and a linearity of the response. In the second part, a summary of timing studies with SiPMs in scintillation detection is presented. It covers results of tests of transit time spread at single photon detection and the best reported time resolution in a fast timing with 511 keV annihilation quanta, on the way to time-of-flight positron emission tomography (PET) scanners. Next, various tests reported for a combination of SiPM arrays of different size coupled to different scintillators used in gamma spectrometry, like NaI(Tl), BGO, LaBr3, and LYSO are reviewed, including tests of 3″ × 3″ LaBr3:Ce and its co-doped version. Besides of the characterization of different SiPMs in scintillation detection some examples of the most modern medical instrumentation are presented including the newest Siemens Biograph Vision PET/CT scanner and the uExplorer whole body PET scanner.
- 1 March 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (03) , P03030
Fast neutron and gamma ray pulse shape discrimination in EJ-276 and EJ-276G plastic scintillators
- 1 March 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (03) , P03030
Fast neutron and gamma ray pulse shape discrimination in EJ-276 and EJ-276G plastic scintillators