Kousuke Ooe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kousuke Ooe has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Shunsuke Kobayashi
Nanostructures Research Laboratory Japan Fine Ceramics Center Nagoya Japan
6 shared publications - Daisuke Kan
Kyoto University
5 shared publications - Takehito Seki
Institute of Engineering Innovation School of Engineering The University of Tokyo Tokyo Japan
5 shared publications - Yufan Shen
Institute for Chemical Research, Kyoto University, Uji, Kyoto, Japan
5 shared publications - Yuichi Shimakawa
Kyoto University
5 shared publications - Naoya Shibata
Institute of Engineering Innovation, the University of Tokyo, Tokyo, JAPAN
4 shared publications
Latest Publications
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 10 (5)
Ferromagnetic-like behavior emerging from local CoO 6 honeycomb motifs in Co-doped NaSbO 3 thin films
- 22 May 2026
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 10 (5)
Ferromagnetic-like behavior emerging from local CoO 6 honeycomb motifs in Co-doped NaSbO 3 thin films
- Open Access
- 17 May 2026
- Published by Wiley in Small Methods
- Vol. 10 (11) , e01661
Enhancing Dose Efficiency of Optimum Bright‐Field Scanning Transmission Electron Microscopy Using a Phase‐Shifted Electron Probe
Observing beam‐sensitive materials using scanning transmission electron microscopy (STEM) at low electron dose conditions is challenging due to the low signal‐to‐noise ratio (SNR) of images. In this study, we aimed to improve the SNR of optimum bright‐field (OBF) STEM by introducing phase shifts to the incident electron probe using lens aberrations. Theoretical analysis and multislice simulations revealed that spherical aberration enhances low‐frequency contrast without introducing image artifacts, unlike simple defocus, which causes oscillations in the contrast transfer function. This approach improves the visibility of structural features in low‐dose conditions and may enable more efficient imaging of beam‐sensitive materials such as zeolites.
- 17 May 2026
- Published by Wiley in Small Methods
- Vol. 10 (11) , e01661
Open AccessEnhancing Dose Efficiency of Optimum Bright‐Field Scanning Transmission Electron Microscopy Using a Phase‐Shifted Electron Probe
Observing beam‐sensitive materials using scanning transmission electron microscopy (STEM) at low electron dose conditions is challenging due to the low signal‐to‐noise ratio (SNR) of images. In this study, we aimed to improve the SNR of optimum bright‐field (OBF) STEM by introducing phase shifts to the incident electron probe using lens aberrations. Theoretical analysis and multislice simulations revealed that spherical aberration enhances low‐frequency contrast without introducing image artifacts, unlike simple defocus, which causes oscillations in the contrast transfer function. This approach improves the visibility of structural features in low‐dose conditions and may enable more efficient imaging of beam‐sensitive materials such as zeolites.
- 29 April 2026
- Published by Oxford University Press (OUP) in Microscopy
A strategy for dose-efficient atomic-resolution OBF-STEM imaging of zeolites
Observation of beam-sensitive materials in scanning transmission electron microscopy (STEM) requires not only the development of highly dose-efficient imaging techniques but also the selection of appropriate imaging conditions such as the raster-scan sampling rate and optical parameters to realize a low-dose condition effectively. In this study, the convergence angle, sampling rates and electron dose dependencies of the signal-to-noise ratio in optimum bright-field (OBF) STEM, a recently developed dose-efficient STEM imaging method, are investigated, which guides us in choosing optimal conditions to observe beam-sensitive porous materials such as zeolites. The parameters necessary for real-time OBF imaging are also considered towards practical live imaging at low dose. Experimental atomic-resolution OBF STEM observations of zeolites are then demonstrated using the strategy investigated above.
- 29 April 2026
- Published by Oxford University Press (OUP) in Microscopy
A strategy for dose-efficient atomic-resolution OBF-STEM imaging of zeolites
Observation of beam-sensitive materials in scanning transmission electron microscopy (STEM) requires not only the development of highly dose-efficient imaging techniques but also the selection of appropriate imaging conditions such as the raster-scan sampling rate and optical parameters to realize a low-dose condition effectively. In this study, the convergence angle, sampling rates and electron dose dependencies of the signal-to-noise ratio in optimum bright-field (OBF) STEM, a recently developed dose-efficient STEM imaging method, are investigated, which guides us in choosing optimal conditions to observe beam-sensitive porous materials such as zeolites. The parameters necessary for real-time OBF imaging are also considered towards practical live imaging at low dose. Experimental atomic-resolution OBF STEM observations of zeolites are then demonstrated using the strategy investigated above.
- Open Access
- 30 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Direct observation of cation-dependent polarisation switching dynamics in fluorite ferroelectrics
Fluorite ferroelectrics are exciting candidates for next-generation non-volatile memory devices because their unique ferroelectric mechanism, which arises from unconventional oxygen displacements, permits ferroelectricity with minimal thickness constraints. However, the polarisation switching mechanism remains the subject of intense debate due to a limited understanding of the atomic-scale dynamics which are extremely challenging to detect and measure. Here, we observe directly the polarisation switching pathways by visualising oxygen site dynamics in ZrO2 and Hf0.5Zr0.5O2 freestanding membranes using an advanced atomic-column imaging technique-optimum bright-field scanning transmission electron microscopy. We observe that the 180° and 90° polarisation pathways involve different nonpolar intermediate states with distinct spatial scales. Coupled with density functional theory, we also reveal how different cation species in fluorite oxides impact the accessible polarisation switching pathways. Our atomic-level insights into the polarisation switching dynamics open new avenues for the advanced engineering of fluorite ferroelectric materials and resulting memory devices.
- 30 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessDirect observation of cation-dependent polarisation switching dynamics in fluorite ferroelectrics
Fluorite ferroelectrics are exciting candidates for next-generation non-volatile memory devices because their unique ferroelectric mechanism, which arises from unconventional oxygen displacements, permits ferroelectricity with minimal thickness constraints. However, the polarisation switching mechanism remains the subject of intense debate due to a limited understanding of the atomic-scale dynamics which are extremely challenging to detect and measure. Here, we observe directly the polarisation switching pathways by visualising oxygen site dynamics in ZrO2 and Hf0.5Zr0.5O2 freestanding membranes using an advanced atomic-column imaging technique-optimum bright-field scanning transmission electron microscopy. We observe that the 180° and 90° polarisation pathways involve different nonpolar intermediate states with distinct spatial scales. Coupled with density functional theory, we also reveal how different cation species in fluorite oxides impact the accessible polarisation switching pathways. Our atomic-level insights into the polarisation switching dynamics open new avenues for the advanced engineering of fluorite ferroelectric materials and resulting memory devices.
- Open Access
- 12 November 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (6)
Optimizing Structure Factors From Four-dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix
Quantitative potential retrieval in scanning transmission electron microscopy (STEM) is of much importance for detailed material characterization but is often hindered by substantial multiple scattering effects in thicker samples. Here, we propose a gradient-descent-based optimization algorithm to obtain the quantitative potential from thick samples from a four-dimensional (4D) STEM dataset using the scattering matrix (S-matrix), which is an operator to calculate the exit-surface wavefunction in the presence of multiple scattering. This optimization uses optimum bright-field STEM data as an initial guess of potential and a loss function based on measured and estimated 4D STEM datasets without the regularization terms commonly used in iterative potential retrieval techniques in STEM. We show the capabilities of our approach through systematic simulations across a range of sample thicknesses, doses, and degrees of spatial incoherence and by applying it to experimental data. The extension of our algorithm from pixelated to segmented detectors is also investigated.
- 12 November 2025
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 31 (6)
Open AccessOptimizing Structure Factors From Four-dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix
Quantitative potential retrieval in scanning transmission electron microscopy (STEM) is of much importance for detailed material characterization but is often hindered by substantial multiple scattering effects in thicker samples. Here, we propose a gradient-descent-based optimization algorithm to obtain the quantitative potential from thick samples from a four-dimensional (4D) STEM dataset using the scattering matrix (S-matrix), which is an operator to calculate the exit-surface wavefunction in the presence of multiple scattering. This optimization uses optimum bright-field STEM data as an initial guess of potential and a loss function based on measured and estimated 4D STEM datasets without the regularization terms commonly used in iterative potential retrieval techniques in STEM. We show the capabilities of our approach through systematic simulations across a range of sample thicknesses, doses, and degrees of spatial incoherence and by applying it to experimental data. The extension of our algorithm from pixelated to segmented detectors is also investigated.
- Open Access
Direct observation of cation-dependent polarisation switching dynamics in fluorite ferroelectrics
Fluorite ferroelectrics are exciting candidates for next-generation non-volatile memory devices because their unique ferroelectric mechanism, which arises from unconventional oxygen displacements, permits ferroelectricity with minimal thickness constraints. However, the polarisation switching mechanism remains the subject of intense debate due to a limited understanding of the atomic-scale dynamics which are extremely challenging to detect and measure. Here, we observe directly the polarisation switching pathways by visualising oxygen site dynamics in ZrO2 and Hf0.5Zr0.5O2 freestanding membranes using an advanced atomic-column imaging technique-optimum bright-field scanning transmission electron microscopy. We observe that the 180- and 90-degree polarisation pathways involve different nonpolar intermediate states with distinct spatial scales. Coupled with density functional theory, we also reveal how different cation species in fluorite oxides impact the accessible polarisation switching pathways. Our atomic-level insights into the polarisation switching dynamics open new avenues for the advanced engineering of fluorite ferroelectric materials and resulting memory devices.
Open AccessDirect observation of cation-dependent polarisation switching dynamics in fluorite ferroelectrics
Fluorite ferroelectrics are exciting candidates for next-generation non-volatile memory devices because their unique ferroelectric mechanism, which arises from unconventional oxygen displacements, permits ferroelectricity with minimal thickness constraints. However, the polarisation switching mechanism remains the subject of intense debate due to a limited understanding of the atomic-scale dynamics which are extremely challenging to detect and measure. Here, we observe directly the polarisation switching pathways by visualising oxygen site dynamics in ZrO2 and Hf0.5Zr0.5O2 freestanding membranes using an advanced atomic-column imaging technique-optimum bright-field scanning transmission electron microscopy. We observe that the 180- and 90-degree polarisation pathways involve different nonpolar intermediate states with distinct spatial scales. Coupled with density functional theory, we also reveal how different cation species in fluorite oxides impact the accessible polarisation switching pathways. Our atomic-level insights into the polarisation switching dynamics open new avenues for the advanced engineering of fluorite ferroelectric materials and resulting memory devices.
- 15 September 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (11)
Ferroelectric ZrO2/Hf0.5Zr0.5O2 epitaxial Moiré heterostructures
While oxide heterostructures with emergent properties have garnered a great amount of research interest, heterostructures consisting of oxides with metastable phases have barely been investigated. Here, we fabricated epitaxial bilayer structures based on ZrO2 (ZO) and Hf0.5Zr0.5O2 (HZO) whose single layers, respectively, possess non-polar and polar metastable structures and investigated their structural and ferroelectric properties. We found that the ZO/HZO heterostructures exhibit ferroelectric polarizations comparable to those of HZO films. The bilayer is found to consist of polar orthorhombic lattices with Moiré superlattices, highlighting the key role of the ZO/HZO interfaces in stabilizing the ferroelectricity in the bilayer structures. Furthermore, we found that both the dielectric constant and polarization are increased by reducing the thickness of HZO and ZO layers in the stacked structures and enhancing the interfacial effects.
- 15 September 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 127 (11)
Ferroelectric ZrO2/Hf0.5Zr0.5O2 epitaxial Moiré heterostructures
While oxide heterostructures with emergent properties have garnered a great amount of research interest, heterostructures consisting of oxides with metastable phases have barely been investigated. Here, we fabricated epitaxial bilayer structures based on ZrO2 (ZO) and Hf0.5Zr0.5O2 (HZO) whose single layers, respectively, possess non-polar and polar metastable structures and investigated their structural and ferroelectric properties. We found that the ZO/HZO heterostructures exhibit ferroelectric polarizations comparable to those of HZO films. The bilayer is found to consist of polar orthorhombic lattices with Moiré superlattices, highlighting the key role of the ZO/HZO interfaces in stabilizing the ferroelectricity in the bilayer structures. Furthermore, we found that both the dielectric constant and polarization are increased by reducing the thickness of HZO and ZO layers in the stacked structures and enhancing the interfacial effects.
- Open Access
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
Humidity-driven modulation of ferroelectricity in hafnia–zirconia membranes
Ferroelectric hafnia-based compounds, known for exhibiting strong ferroelectricity in films of sub-5 nm thickness, hold significant potential for being integrated into complementary metal-oxide-semiconductor devices. Due to the polymorphic nature of hafnia, their ferroelectric properties can be modulated through various mechanisms, including defects, strain, and electrochemical states. In this study, we fabricated ultrathin freestanding hafnia membranes, free from substrate and electrode-capping effects, to explore the relationship between their intrinsic ferroelectricity and surface electrochemical state by modulating humidity conditions during scanning probe microscopy measurements. Our results demonstrate enhanced ferroelectricity in hafnia under low-humidity conditions without requiring a wake-up process. This enhancement is attributed to reduced adsorption of water molecules on the membrane surface, which helps preserve oxygen vacancies that stabilize the ferroelectric phase in hafnia under an applied electric field. These findings suggest that beyond electrical control via field-cycling-induced phase transitions, electrochemical modulation through humidity provides an effective approach for tuning the ferroelectric properties of hafnia-based compounds, optimizing their performance in flexible nanoelectronics applications.
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
Open AccessHumidity-driven modulation of ferroelectricity in hafnia–zirconia membranes
Ferroelectric hafnia-based compounds, known for exhibiting strong ferroelectricity in films of sub-5 nm thickness, hold significant potential for being integrated into complementary metal-oxide-semiconductor devices. Due to the polymorphic nature of hafnia, their ferroelectric properties can be modulated through various mechanisms, including defects, strain, and electrochemical states. In this study, we fabricated ultrathin freestanding hafnia membranes, free from substrate and electrode-capping effects, to explore the relationship between their intrinsic ferroelectricity and surface electrochemical state by modulating humidity conditions during scanning probe microscopy measurements. Our results demonstrate enhanced ferroelectricity in hafnia under low-humidity conditions without requiring a wake-up process. This enhancement is attributed to reduced adsorption of water molecules on the membrane surface, which helps preserve oxygen vacancies that stabilize the ferroelectric phase in hafnia under an applied electric field. These findings suggest that beyond electrical control via field-cycling-induced phase transitions, electrochemical modulation through humidity provides an effective approach for tuning the ferroelectric properties of hafnia-based compounds, optimizing their performance in flexible nanoelectronics applications.
- 28 February 2025
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 9 (2)
Ultrathin freestanding membranes of with metastable structures and strain-dependent electrical properties- 28 February 2025
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 9 (2)
Ultrathin freestanding membranes of with metastable structures and strain-dependent electrical properties- Open Access
- 1 January 2025
- Published by ScienceOpen
- p. e034
Low-dose STEM Data Acquisition at Atomic-scale via Optimum Bright-field Imaging
Scanning transmission electron microscopy (STEM) is a powerful technique for analysing materials at atomic scale, enabling the relationship between local atomic structures and materials properties to be clarified. One of the most challenging topics in STEM analysis is the observation of beam-sensitive materials (e.g., porous materials, energy materials, and organic materials, etc.). Under the electron irradiation, these materials are easily damaged, requiring the use of low-dose condition for observation. While low-dose conditions are effective in reducing irradiation damage, this condition also leads to a poor signal-to-noise ratio (SNR) due to substantial shot noise, which hinders detailed structure analysis. Here, we developed an optimum bright-field (OBF) STEM using a segmented-type detector as a low-dose imaging technique [ 1]. Conventionally, STEM images are formed by single annular detectors such as annular dark-field (ADF) or annular bright-field (ABF) detectors. Although these imaging methods offer robust and straightforward interpretations of observed atomic structures, their imaging efficiency is relatively low because they use only a limited fraction of transmitted or scattered electrons on the diffraction plane. To obtain richer information about the diffraction pattern, segmented and pixelated type detectors have recently been used extensively [ 2]. In particular, segmented detector allow read-out speeds as fast as conventional detectors, making them especially useful for actual experimental data acquisition. Figure 1 shows the workflow of OBF STEM reconstruction using the segmented detector. Spatial frequency filters, designed to maximise the SNR of the final reconstructed image, are applied to each channel image in Fourier space. The filtered channel images are summed and then inverse Fourier transformed to obtain the OBF image in real space. Figure 1 Schematic illustration of the OBF STEM reconstruction workflow using a segmented detector [ 3]. For simplicity, the case of four-segmented detector is shown. After acquisition of channel images from the segmented detector, each image is Fourier transformed and multiplied by frequency filters, which is designed to maximise the SNR of OBF image. These images are summed and subsequently inverse Fourier transformed to produce the OBF image.
- 1 January 2025
- Published by ScienceOpen
- p. e034
Open AccessLow-dose STEM Data Acquisition at Atomic-scale via Optimum Bright-field Imaging
Scanning transmission electron microscopy (STEM) is a powerful technique for analysing materials at atomic scale, enabling the relationship between local atomic structures and materials properties to be clarified. One of the most challenging topics in STEM analysis is the observation of beam-sensitive materials (e.g., porous materials, energy materials, and organic materials, etc.). Under the electron irradiation, these materials are easily damaged, requiring the use of low-dose condition for observation. While low-dose conditions are effective in reducing irradiation damage, this condition also leads to a poor signal-to-noise ratio (SNR) due to substantial shot noise, which hinders detailed structure analysis. Here, we developed an optimum bright-field (OBF) STEM using a segmented-type detector as a low-dose imaging technique [ 1]. Conventionally, STEM images are formed by single annular detectors such as annular dark-field (ADF) or annular bright-field (ABF) detectors. Although these imaging methods offer robust and straightforward interpretations of observed atomic structures, their imaging efficiency is relatively low because they use only a limited fraction of transmitted or scattered electrons on the diffraction plane. To obtain richer information about the diffraction pattern, segmented and pixelated type detectors have recently been used extensively [ 2]. In particular, segmented detector allow read-out speeds as fast as conventional detectors, making them especially useful for actual experimental data acquisition. Figure 1 shows the workflow of OBF STEM reconstruction using the segmented detector. Spatial frequency filters, designed to maximise the SNR of the final reconstructed image, are applied to each channel image in Fourier space. The filtered channel images are summed and then inverse Fourier transformed to obtain the OBF image in real space. Figure 1 Schematic illustration of the OBF STEM reconstruction workflow using a segmented detector [ 3]. For simplicity, the case of four-segmented detector is shown. After acquisition of channel images from the segmented detector, each image is Fourier transformed and multiplied by frequency filters, which is designed to maximise the SNR of OBF image. These images are summed and subsequently inverse Fourier transformed to produce the OBF image.