Natalia Lewandowska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Natalia Lewandowska has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Frąckowiak
Faculty of Environmental Engineering and Energy, Institute of Thermal Energy, Poznan University of Technology, 60-965 Poznan, Poland
2 shared publications - Bartosz Ziegler
Institute of Thermal Energy, Faculty of Environmental and Energy Engineering, Poznań University of Technology, Poznan, Poland
2 shared publications M. Micker
Poznan University of Medical Sciences (PUMS)
2 shared publicationsM. Warot
Poznan University of Medical Sciences (PUMS)
2 shared publicationsMichał Ciałkowski
2 shared publicationsP. Chęciński
Poznan University of Technology
2 shared publications
Latest Publications
- Open Access
Performance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
This study investigates the efficiency evaluation of a compressor rotor designed for drive units requiring compressors with a power demand of less than 30 kW. The primary aim of the research presented in this article is to assess the feasibility of utilizing axial compressors to maintain high efficiency across a broad range of rotor speeds. A critical challenge in the considered power range is the occurrence of low Reynolds numbers, specifically those below 250,000. This research seeks to identify the underlying causes of efficiency degradation at low Reynolds numbers and determine the rotor’s geometric parameters which most significantly influence the localized efficiency drop. Compressor efficiency was evaluated through numerical simulations. The numerical model was validated using experimental data and subjected to a grid independence study. Simulations were conducted for nine geometric configurations of the axial compressor rotor, with modifications to parameters such as the blade angle, blade thickness, blade solidity, and hub-to-tip ratio. For each configuration, a series of simulations was performed at rotor speeds ranging from 400 RPM to 2400 RPM. The simulation results indicated that the blade angle solidity was the most influential parameter affecting efficiency. A reduction in the blade angle led to approximately a 20% decrease in efficiency, primarily due to localized flow separation near the blade tip. Additionally, altering the number of blades caused a 20% efficiency reduction attributed to hub corner separation. The findings enabled the identification of optimal parameters, which will serve as a foundation for efficiency testing in the multistage configuration.
Open AccessPerformance Analysis of a Compressor Rotor Dedicated to Low-Power Drive Systems
This study investigates the efficiency evaluation of a compressor rotor designed for drive units requiring compressors with a power demand of less than 30 kW. The primary aim of the research presented in this article is to assess the feasibility of utilizing axial compressors to maintain high efficiency across a broad range of rotor speeds. A critical challenge in the considered power range is the occurrence of low Reynolds numbers, specifically those below 250,000. This research seeks to identify the underlying causes of efficiency degradation at low Reynolds numbers and determine the rotor’s geometric parameters which most significantly influence the localized efficiency drop. Compressor efficiency was evaluated through numerical simulations. The numerical model was validated using experimental data and subjected to a grid independence study. Simulations were conducted for nine geometric configurations of the axial compressor rotor, with modifications to parameters such as the blade angle, blade thickness, blade solidity, and hub-to-tip ratio. For each configuration, a series of simulations was performed at rotor speeds ranging from 400 RPM to 2400 RPM. The simulation results indicated that the blade angle solidity was the most influential parameter affecting efficiency. A reduction in the blade angle led to approximately a 20% decrease in efficiency, primarily due to localized flow separation near the blade tip. Additionally, altering the number of blades caused a 20% efficiency reduction attributed to hub corner separation. The findings enabled the identification of optimal parameters, which will serve as a foundation for efficiency testing in the multistage configuration.
- 31 August 2024
- Published by Springer Nature
- p. 128-137
Influence of Turbulence Modelling Approach on Characteristics of Premixed Jet Flames Doped with Ammonia
- 31 August 2024
- Published by Springer Nature
- p. 128-137
Influence of Turbulence Modelling Approach on Characteristics of Premixed Jet Flames Doped with Ammonia
- 31 August 2024
- Published by Springer Nature
- p. 148-157
Comparative Analysis of Turbulence Models for Turbulent Non-premixed Combustion: A Hybrid Rocket Engine Case Study
- 31 August 2024
- Published by Springer Nature
- p. 148-157
Comparative Analysis of Turbulence Models for Turbulent Non-premixed Combustion: A Hybrid Rocket Engine Case Study
- Open Access
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02003
Meshing strategy for bifurcation arteries in the context of blood flow simulation accuracy
The study presents a mesh dependency study for a carotid artery bifurcation geometry of a real-life specimen. The results of time-averaged velocity profiles at artery control surfaces and wall shear stresses are compared between a set of structured and unstructured meshes, with varying non–dimensional boundary layer first element thickness (y+) parameter. A set of four meshes in total is considered: a full–hexagonal structured mesh, an unstructured tetrahedral mesh with prism inflation layer, both created for y+=1 and y+=30. Apart from numerical results, overall mesh creation work time, overall analysisstability are compared with the mesh quality results: cell non–orthogonality, cell skew and aspect ratio. Numerical results are validated against results of real–life CT examination performed in Poznań Medical University.
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02003
Open AccessMeshing strategy for bifurcation arteries in the context of blood flow simulation accuracy
The study presents a mesh dependency study for a carotid artery bifurcation geometry of a real-life specimen. The results of time-averaged velocity profiles at artery control surfaces and wall shear stresses are compared between a set of structured and unstructured meshes, with varying non–dimensional boundary layer first element thickness (y+) parameter. A set of four meshes in total is considered: a full–hexagonal structured mesh, an unstructured tetrahedral mesh with prism inflation layer, both created for y+=1 and y+=30. Apart from numerical results, overall mesh creation work time, overall analysisstability are compared with the mesh quality results: cell non–orthogonality, cell skew and aspect ratio. Numerical results are validated against results of real–life CT examination performed in Poznań Medical University.
- Open Access
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02005
The impact of the artery geometry with the sewn surgical patch on the blood flow disorders
The research concerns the development of geometric variants of patches sewn into the common carotid artery during surgery of the atherosclerotic plaques removal. Based on analytical methods, thegeometry of the patch described by the polynomial function has been developed. The simulations of blood flow in the arteries with the sewn patch were performed. The study included the influence of the patient’s diameter and the width of the chosen patch on blood flow disorders. The result of the research is the algorithm of selecting the geometry of the arterial patch to the individual geometrical featuresof the patient’s artery. The studies result will comprise the development of software, which, upon introduction of input data related to arterial geometry, patch length and patient’s blood parameters (affecting the fluid density and viscosity), shall generate an accurate contour of the patch of width causing no flow disorders.
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02005
Open AccessThe impact of the artery geometry with the sewn surgical patch on the blood flow disorders
The research concerns the development of geometric variants of patches sewn into the common carotid artery during surgery of the atherosclerotic plaques removal. Based on analytical methods, thegeometry of the patch described by the polynomial function has been developed. The simulations of blood flow in the arteries with the sewn patch were performed. The study included the influence of the patient’s diameter and the width of the chosen patch on blood flow disorders. The result of the research is the algorithm of selecting the geometry of the arterial patch to the individual geometrical featuresof the patient’s artery. The studies result will comprise the development of software, which, upon introduction of input data related to arterial geometry, patch length and patient’s blood parameters (affecting the fluid density and viscosity), shall generate an accurate contour of the patch of width causing no flow disorders.
- Open Access
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02004
A new concept of surgical patch used in vascular surgery
During the surgery of atherosclerotic plaques removal, a longitudinal artery incision is made. Frequently used practice is sewing a patch in the incision area. It reduces the risk of narrowing of the artery but also causes its widening. The channel expansion leads to the enhancing separation of the boundary layer and vortexes creation. The selection of the patch size is based on the surgeon’s experience. The purpose of the studies is to determine a new geometric concept of a patch. The resultingpatch is fully parameterizedand can be influenced by its geometric shape, adapting it to the patient’s diameter. Simulations of blood flow in the artery were performed, with the patch used during the surgery and a patch developed by the authors. The analysis of the flow field in terms of the wall shear stresses (WSS) and velocity distribution has shown, that the patch developed by authors give the most satisfactory results.
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 02004
Open AccessA new concept of surgical patch used in vascular surgery
During the surgery of atherosclerotic plaques removal, a longitudinal artery incision is made. Frequently used practice is sewing a patch in the incision area. It reduces the risk of narrowing of the artery but also causes its widening. The channel expansion leads to the enhancing separation of the boundary layer and vortexes creation. The selection of the patch size is based on the surgeon’s experience. The purpose of the studies is to determine a new geometric concept of a patch. The resultingpatch is fully parameterizedand can be influenced by its geometric shape, adapting it to the patient’s diameter. Simulations of blood flow in the artery were performed, with the patch used during the surgery and a patch developed by the authors. The analysis of the flow field in terms of the wall shear stresses (WSS) and velocity distribution has shown, that the patch developed by authors give the most satisfactory results.
- Open Access
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 06007
Swirled injector modeling for cavitating multiphase flow
The goal of this study is to present a comparison between different approaches to multiphase injection modeling of self-pressurized rocket engine propellant. Swirled, tangential orifice injector of nitrous oxide, for an “N” class hybrid rocket motor is the object of the study. A brief descriptionof the injector purpose and geometry is provided, followed by a description of different approaches for flow modeling. Examined techniques range from 0D, Homogeneous Equilibrium Model (HEM) to 3D multiphase with mass and heat exchange between phases. Results of analyses are provided and compared with experimental data. The discrepancies between results are of significant magnitude but expected nature. Co clusions about most feasible approaches for engineering calculations are drawn.
- 8 November 2019
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 128, 06007
Open AccessSwirled injector modeling for cavitating multiphase flow
The goal of this study is to present a comparison between different approaches to multiphase injection modeling of self-pressurized rocket engine propellant. Swirled, tangential orifice injector of nitrous oxide, for an “N” class hybrid rocket motor is the object of the study. A brief descriptionof the injector purpose and geometry is provided, followed by a description of different approaches for flow modeling. Examined techniques range from 0D, Homogeneous Equilibrium Model (HEM) to 3D multiphase with mass and heat exchange between phases. Results of analyses are provided and compared with experimental data. The discrepancies between results are of significant magnitude but expected nature. Co clusions about most feasible approaches for engineering calculations are drawn.
- 27 July 2019
- Published by Springer Nature
- p. 23-36
Numerical Study of Carotid Bifurcation Angle Effect on Blood Flow Disorders
- 27 July 2019
- Published by Springer Nature
- p. 23-36
Numerical Study of Carotid Bifurcation Angle Effect on Blood Flow Disorders
- 27 July 2019
- Published by Springer Nature
- p. 1-22
The Impact of Patches on Blood Flow Disorders In Carotid Artery
- 27 July 2019
- Published by Springer Nature
- p. 1-22
The Impact of Patches on Blood Flow Disorders In Carotid Artery