ANAna Novo

Ana Novo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ana Novo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Celia M. Manaia

    CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Universidade Católica Portuguesa, Porto, Portugal

    4 shared publications
  • Olga Cristina Nunes

    LEPABE‐Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering University of Porto Porto Portugal

    3 shared publications
  • Ana Rita Lopes

    LEPABE, Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal

    1 shared publication
  • Bruno Coelho

    LEPAE/Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal

    1 shared publication
  • Elionora Hantsis-Zacharov

    Department of Biology and Environment, Faculty of Natural Sciences, University of Haifa, Oranim, Tivon 36006, Israel

    1 shared publication
  • Ivone Vaz-Moreira

    Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Porto, Portugal

    1 shared publication

Latest Publications

  • Top Cited Papers

    Antibiotic resistance, antimicrobial residues and bacterial community composition in urban wastewater

    by Ana Novo, Sandra André, Paula Viana, Olga C. Nunes, Célia M. Manaia


  • Acinetobacter rudis sp. nov., isolated from raw milk and raw wastewater

    by Ivone Vaz-Moreira, Ana Novo, Elionora Hantsis-Zacharov, Ana Rita Lopes, Margarita Gomila, Olga C. Nunes, Célia M. Manaia, Malka Halpern

    Two bacterial strains, G30T and A1PC16, isolated respectively from raw milk and raw wastewater, were characterized using a polyphasic approach. Chemotaxonomic characterization supported the inclusion of these strains in the genus Acinetobacter, with Q-8 and Q-9 as the major respiratory quinones, genomic DNA G+C contents within the range observed for this genus (38–47 mol%) and C16 : 0, C18 : 1ω9c and C16 : 1ω7c/iso-C15 : 0 2-OH as the predominant fatty acids. The observation of 16S rRNA gene sequence similarity lower than 97 % with other Acinetobacter species with validly published names led to the hypothesis that these isolates could represent a novel species. This hypothesis was supported by comparative analysis of partial sequences of the genes rpoB and gyrB, which showed that strains G30T and A1PC16 did not cluster with any species with validly published names, forming a distinct lineage. DNA–DNA hybridizations confirmed that the two strains were members of the same species, which could be distinguished from their congeners by several phenotypic characteristics. On the basis of these arguments, it is proposed that strains G30T and A1PC16 represent a novel species, for which the name Acinetobacter rudis sp. nov. is proposed. The type strain is strain G30T ( = LMG 26107T = CCUG 57889T = DSM 24031T = CECT 7818T).


  • Factors influencing antibiotic resistance burden in municipal wastewater treatment plants

    by Ana Novo, Célia M. Manaia

    Municipal wastewater treatment plants are recognized reservoirs of antibiotic-resistant bacteria. Three municipal wastewater treatment plants differing on the dimensions and bio-treatment processes were compared for the loads of amoxicillin-, tetracycline-, and ciprofloxacin-resistant heterotrophic bacteria, enterobacteria, and enterococci in the raw inflow and in the treated effluents. The sewage received by each plant, in average, corresponded to 85,000 inhabitant equivalents (IE), including pretreated industrial effluents (≤30%) in plant activated sludge, 105,000 IE, including pretreated hospital effluents (≤15%) in plant trickling filter, and 2,000 IE, exclusively of domestic sewage, in plant submerged aerated filter. The presence of pretreated industrial effluents or of pretreated hospital sewage in the raw inflow did not imply significantly higher densities (per milliliter or per IE) of antibiotic-resistant bacteria in the raw wastewater. Longer hydraulic residence periods (24 h) corresponded to higher bacterial removal rates than shorter periods (12 and 9 h), although such efficiency did not imply significant average decreases in the antibiotic resistance prevalence of the treated effluent. The bacterial loads in the treated effluent could be ranked according to the treatment efficiency, suggesting that the characteristics of the raw inflow may have less relevance on the quality of the treated wastewater than other aspects, such as the inflow volume, the type of biological treatment, or the hydraulic residence time.


  • Ciprofloxacin Resistance in Domestic Wastewater Treatment Plants

    by Celia M. Manaia, Ana Novo, Bruno Coelho, Olga C. Nunes