Mohsen Omidvar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohsen Omidvar has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Bahman Ramavandi
Systems Environmental Health and Energy Research Center, The Persian Gulf Biomedical Sciences Research Institute, Bushehr University of Medical Sciences, Bushehr, Iran
6 shared publications Bahman Ramavandi
Department of Environmental Health Engineering, Faculty of Health and Nutrition, Bushehr University of Medical Sciences, Bushehr, Iran
3 shared publicationsRauf Foroutan
Faculty of Chemical and Petroleum Engineering, University of Tabriz, Tabriz, Iran
3 shared publicationsSima Farjadfard
Department of Environmental Health Engineering, Faculty of Health and Nutrition, Bushehr University of Medical Sciences, Bushehr, Iran
3 shared publicationsSina Dobaradaran
Department of Environmental Health Engineering, Faculty of Health and Nutrition, Bushehr University of Medical Sciences, Bushehr, Iran
3 shared publicationsHossein Arfaeinia
Department of Environmental Health Engineering, Faculty of Health and Nutrition, Bushehr University of Medical Sciences, Bushehr, Iran
2 shared publications
Latest Publications
- Open Access
- 19 November 2024
- Published by MDPI AG in Preprints.org
Investigating the Effectiveness of Smoke Control Devices in Fire Emergency Scenario in Hospitals: A CFD Approach
Fire is a major hazard in hospitals, often caused by flammable liquids and medical gases, and can lead to significant losses due to limited patient mobility. This study simulated the effectiveness of portable and ceiling exhaust systems in reducing smoke, heat, and toxic gases in a hospital Neonatal Intensive Care Unit (NICU) using Computational Fluid Dynamics (CFD).The study began by converting a 2D sketch of the NICU into a 3D model using SketchUp, which was then imported into PyroSim software. Properties of objects and fire scenarios were set in PyroSim, and simulation results for temperature, visibility, and toxic gases (CO, CO2, O2) were generated as 3D cross-sectional views and profiles.In the simulation, the ceiling exhaust contained smoke within the fire room, preserving visibility in other areas, while the portable exhaust spread smoke to corridors, reducing visibility to zero. The ceiling exhaust maintained temperatures between 60–70°C, while the portable exhaust exceeded 80°C. CO concentrations peaked at 700 ppm without exhaust, dropped to 400 ppm with portable exhaust, and 300 ppm with ceiling exhaust. Oxygen levels fell to 18% with either exhaust, but remained at 20% with ceiling exhaust. The ceiling exhaust also reduced CO2 in exit rooms from 18,000 ppm to below 12,000 ppm, while portable exhaust reduced it by only 2,000 ppm. These findings can guide hospital designers and firefighting teams in selecting optimal fire control equipment, enhancing building safety and firefighting strategies.
- 19 November 2024
- Published by MDPI AG in Preprints.org
Open AccessInvestigating the Effectiveness of Smoke Control Devices in Fire Emergency Scenario in Hospitals: A CFD Approach
Fire is a major hazard in hospitals, often caused by flammable liquids and medical gases, and can lead to significant losses due to limited patient mobility. This study simulated the effectiveness of portable and ceiling exhaust systems in reducing smoke, heat, and toxic gases in a hospital Neonatal Intensive Care Unit (NICU) using Computational Fluid Dynamics (CFD).The study began by converting a 2D sketch of the NICU into a 3D model using SketchUp, which was then imported into PyroSim software. Properties of objects and fire scenarios were set in PyroSim, and simulation results for temperature, visibility, and toxic gases (CO, CO2, O2) were generated as 3D cross-sectional views and profiles.In the simulation, the ceiling exhaust contained smoke within the fire room, preserving visibility in other areas, while the portable exhaust spread smoke to corridors, reducing visibility to zero. The ceiling exhaust maintained temperatures between 60–70°C, while the portable exhaust exceeded 80°C. CO concentrations peaked at 700 ppm without exhaust, dropped to 400 ppm with portable exhaust, and 300 ppm with ceiling exhaust. Oxygen levels fell to 18% with either exhaust, but remained at 20% with ceiling exhaust. The ceiling exhaust also reduced CO2 in exit rooms from 18,000 ppm to below 12,000 ppm, while portable exhaust reduced it by only 2,000 ppm. These findings can guide hospital designers and firefighting teams in selecting optimal fire control equipment, enhancing building safety and firefighting strategies.
- 23 July 2024
- Published by Springer Nature
- p. 123-149
The Bow-Tie Method: A Hybrid System Safety and Risk Analysis Approach for Safety–Critical Sociotechnical Systems
- 23 July 2024
- Published by Springer Nature
- p. 123-149
The Bow-Tie Method: A Hybrid System Safety and Risk Analysis Approach for Safety–Critical Sociotechnical Systems
- RetractionOpen Access
- 26 March 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (18) , 27496
Retraction Note: Photodegradation of ibuprofen laden-wastewater using sea-mud catalyst/H2O2 system: evaluation of sonication modes and energy consumption
- 26 March 2024
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 31 (18) , 27496
RetractionOpen AccessRetraction Note: Photodegradation of ibuprofen laden-wastewater using sea-mud catalyst/H2O2 system: evaluation of sonication modes and energy consumption
- Retracted
- 3 October 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (6) , 16707-16718
RETRACTED ARTICLE: Photodegradation of ibuprofen laden-wastewater using sea-mud catalyst/H2O2 system: evaluation of sonication modes and energy consumption
The main goal of the current investigation was to decontaminate ibuprofen (IBP) from hospital wastewater using sea mud as an H2O2 activator. Sea sludge was converted into catalysts at different temperatures and residence times in furnaces, and then tested in the removal of IBP, and the most efficient ones were reported for the production of catalysts. The catalyst was optimized at 400 °C and 3 h. SEM-mapping, FTIR, EDX, BET, and BJH experiments were used to characterize the catalyst. Experiments were done at two pulsed and continuous ultrasonication modes in a photoreactor, and their efficiencies were statistically compared. The designed variables included IBP concentration (10–100 mg/L), the catalyst concentration (0–3 g/L), pH (4–9), and time (10–90 min). The oxidation process had the maximum efficiency at pH 4, treatment time of 60 min, catalyst quantity of 5 g/L, and IBP content of 50 mg/L. The catalyst was recycled, and in the fifth stage, the removal efficiency of IBP was reduced to 50%. The amount of energy consumed for treating IBP laden-wastewater using the evaluated catalyst in two modes of continuous and pulsed ultrasonic was calculated as 102 kW h/m3 and 10 kW h/m3, respectively. IBP oxidation process was fitted with the first-order kinetic model. The system can be proposed for purifying hospital and pharmaceutical wastewaters.
- 3 October 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (6) , 16707-16718
RetractedRETRACTED ARTICLE: Photodegradation of ibuprofen laden-wastewater using sea-mud catalyst/H2O2 system: evaluation of sonication modes and energy consumption
The main goal of the current investigation was to decontaminate ibuprofen (IBP) from hospital wastewater using sea mud as an H2O2 activator. Sea sludge was converted into catalysts at different temperatures and residence times in furnaces, and then tested in the removal of IBP, and the most efficient ones were reported for the production of catalysts. The catalyst was optimized at 400 °C and 3 h. SEM-mapping, FTIR, EDX, BET, and BJH experiments were used to characterize the catalyst. Experiments were done at two pulsed and continuous ultrasonication modes in a photoreactor, and their efficiencies were statistically compared. The designed variables included IBP concentration (10–100 mg/L), the catalyst concentration (0–3 g/L), pH (4–9), and time (10–90 min). The oxidation process had the maximum efficiency at pH 4, treatment time of 60 min, catalyst quantity of 5 g/L, and IBP content of 50 mg/L. The catalyst was recycled, and in the fifth stage, the removal efficiency of IBP was reduced to 50%. The amount of energy consumed for treating IBP laden-wastewater using the evaluated catalyst in two modes of continuous and pulsed ultrasonic was calculated as 102 kW h/m3 and 10 kW h/m3, respectively. IBP oxidation process was fitted with the first-order kinetic model. The system can be proposed for purifying hospital and pharmaceutical wastewaters.
- 27 February 2021
- Published by Springer Nature in Stochastic Environmental Research and Risk Assessment
- Vol. 35 (12) , 2425-2438
Risk assessment of hot and humid environments through an integrated fuzzy AHP-VIKOR method
- 27 February 2021
- Published by Springer Nature in Stochastic Environmental Research and Risk Assessment
- Vol. 35 (12) , 2425-2438
Risk assessment of hot and humid environments through an integrated fuzzy AHP-VIKOR method
- 1 January 2021
- Published by Elsevier in Chemosphere
- Vol. 262, 128091
Impact of exposure to ambient air pollutants on the admission rate of hospitals for asthma disease in Shiraz, southern Iran
- 1 January 2021
- Published by Elsevier in Chemosphere
- Vol. 262, 128091
Impact of exposure to ambient air pollutants on the admission rate of hospitals for asthma disease in Shiraz, southern Iran
- 1 October 2020
- Published by Elsevier in Chemosphere
- Vol. 257, 127233
Quantification of mortality and morbidity attributed to the ambient air criteria pollutants in Shiraz city, Iran
- 1 October 2020
- Published by Elsevier in Chemosphere
- Vol. 257, 127233
Quantification of mortality and morbidity attributed to the ambient air criteria pollutants in Shiraz city, Iran
- Open Access
- 1 October 2019
- Published by CMV Verlag in Iranian South Medical Journal
- Vol. 22 (4) , 248-263
Necessity of Academic Education in Health, Safety and Environment (HSE) at Postgraduate Level
Background: Nowadays, with the rapid development of industries and technology, the risk of work- related accidents, occupational diseases and environmental pollution is increasing. Considering the importance of preventing these hazards, some universities in Iran have recently trained students in new interdisciplinary specialties such as health, safety and the environment (HSE). Some organizations ...
- 1 October 2019
- Published by CMV Verlag in Iranian South Medical Journal
- Vol. 22 (4) , 248-263
Open AccessNecessity of Academic Education in Health, Safety and Environment (HSE) at Postgraduate Level
Background: Nowadays, with the rapid development of industries and technology, the risk of work- related accidents, occupational diseases and environmental pollution is increasing. Considering the importance of preventing these hazards, some universities in Iran have recently trained students in new interdisciplinary specialties such as health, safety and the environment (HSE). Some organizations ...