Subrat Kumar Barik
Research Subjects
Subrat Kumar Barik has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Pradipta Kishore Dash
Multidisciplinary Research Cell, Siksha O Anusandhan Deemed To Be University, Bhubaneswar, India
2 shared publications Snehamoy Dhar
2 shared publications- Adithya Ballajhi
REVA University,SoEEE,Bengaluru,India
1 shared publication - Arun Kumar Sahoo
IIIT Bhubaneswar
1 shared publication - Bibhu Prasad Ganthia
Electrical Engineering, Indira Gandhi Institute of Technology, Sarang, Dhenkanal, India
1 shared publication - Bikash Pattanayak
National Institute of Technology 2 , Jamshedpur
1 shared publication
Latest Publications
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
Fault detection, classification, and protection in low-voltage direct current microgrid with multiple energy sources using hybrid bidirectional long short-term memory–decision tree approach
This paper delivers an advanced fault management framework for a mesh-type low-voltage direct current (LVDC) microgrid (MG) integrating photovoltaic, wind, battery energy storage systems, and an auxiliary AC grid source. The MG adopts a mesh interconnection topology to enhance reliability, fault tolerance, and power-sharing flexibility. A hybrid diagnostic scheme combining bidirectional long short-term memory (BiLSTM) networks with a Decision Tree (DT) classifier is proposed for intelligent fault detection, classification, and isolation. The BiLSTM module extracts temporal features from DC-link voltage and current signals, while the DT ensures fast classification of fault type and location. MATLAB/Simulink studies were conducted under pole-to-ground and pole-to-pole scenarios. The result confirms that the hybrid BiLSTM–DT outperforms conventional classifiers such as support vector machine, k-nearest neighbors, artificial neural network, and ensemble, achieving accuracy levels of 99.3%–99.8%, sensitivity and specificity above 99%, and an error rate as low as 0.2%. Fault was detected and classified within 0.2 s, with moderate training time of around 90–95 s, which ensures real-time applicability. Compared to the conventional method, where accuracy ranges between 74% and 95% with a higher error rate (up to 25.7%), the hybrid BiLSTM–DT demonstrates more superior precision (99.8%) and F1 score (99.6%–99.8%) while successfully isolating faulty sections without disturbing healthy nodes. These conclusions highlight the potential of the proposed framework for achieving more resilient, intelligent, and self-healing LVDC MGs in the future distributed energy system.
- 1 May 2026
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 18 (3)
Fault detection, classification, and protection in low-voltage direct current microgrid with multiple energy sources using hybrid bidirectional long short-term memory–decision tree approach
This paper delivers an advanced fault management framework for a mesh-type low-voltage direct current (LVDC) microgrid (MG) integrating photovoltaic, wind, battery energy storage systems, and an auxiliary AC grid source. The MG adopts a mesh interconnection topology to enhance reliability, fault tolerance, and power-sharing flexibility. A hybrid diagnostic scheme combining bidirectional long short-term memory (BiLSTM) networks with a Decision Tree (DT) classifier is proposed for intelligent fault detection, classification, and isolation. The BiLSTM module extracts temporal features from DC-link voltage and current signals, while the DT ensures fast classification of fault type and location. MATLAB/Simulink studies were conducted under pole-to-ground and pole-to-pole scenarios. The result confirms that the hybrid BiLSTM–DT outperforms conventional classifiers such as support vector machine, k-nearest neighbors, artificial neural network, and ensemble, achieving accuracy levels of 99.3%–99.8%, sensitivity and specificity above 99%, and an error rate as low as 0.2%. Fault was detected and classified within 0.2 s, with moderate training time of around 90–95 s, which ensures real-time applicability. Compared to the conventional method, where accuracy ranges between 74% and 95% with a higher error rate (up to 25.7%), the hybrid BiLSTM–DT demonstrates more superior precision (99.8%) and F1 score (99.6%–99.8%) while successfully isolating faulty sections without disturbing healthy nodes. These conclusions highlight the potential of the proposed framework for achieving more resilient, intelligent, and self-healing LVDC MGs in the future distributed energy system.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 67-71
DC-Microgrid Fault Detection & Classification Using ANN Enabled BAT Algorithm
Power electronic best components are most sensitive to variation in voltage and current. therefore these components when connected to a DC microgrid needs more attention and protection against a different type of circuit faults like short circuit and open circuit condition. During short circuit condition the flow of heavy current will damage the electronic devices and thereby in order to achieve the protection these electronic devices may trip themselves. sudden tripping of the devices will have an adverse negative impact on the DC microgrid. This paper presents a new ANN-enabled bat algorithm to detect the DC fault and to isolate the fault from the rest part of the system. Matlab simulink based model has been developed to test the prototype and to compare the ANN enabled bat algorithm with other algorithm for comparing the efficiency of the proposed algorithm.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 67-71
DC-Microgrid Fault Detection & Classification Using ANN Enabled BAT Algorithm
Power electronic best components are most sensitive to variation in voltage and current. therefore these components when connected to a DC microgrid needs more attention and protection against a different type of circuit faults like short circuit and open circuit condition. During short circuit condition the flow of heavy current will damage the electronic devices and thereby in order to achieve the protection these electronic devices may trip themselves. sudden tripping of the devices will have an adverse negative impact on the DC microgrid. This paper presents a new ANN-enabled bat algorithm to detect the DC fault and to isolate the fault from the rest part of the system. Matlab simulink based model has been developed to test the prototype and to compare the ANN enabled bat algorithm with other algorithm for comparing the efficiency of the proposed algorithm.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Solution to Economic Dispatch Problem Incorporating Micro Grid with Integration of Wind Energy Using Emperor Penguin Optimization Algorithm
Depletion of fossil fuel and formation of pollutants introduced the microgrid and implement the renewable energy sources to the conventional power generating units. This paper represents the implementation of emperor penguin optimization algorithm to find the optimum solution to economic dispatch of fossil fuel-based generators with ramp rate limits, prohibited operating zones, effect of steam valve and transmission losses. Also, the applied technique solves the optimum dispatch problem for microgrid considering the wind turbine as the renewable energy system. The emperor penguin optimization algorithm considers the huddling nature of emperor penguin to optimize the generation cost. The efficacy of the technique is verified for different test system with the comparison of other applied technique.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Solution to Economic Dispatch Problem Incorporating Micro Grid with Integration of Wind Energy Using Emperor Penguin Optimization Algorithm
Depletion of fossil fuel and formation of pollutants introduced the microgrid and implement the renewable energy sources to the conventional power generating units. This paper represents the implementation of emperor penguin optimization algorithm to find the optimum solution to economic dispatch of fossil fuel-based generators with ramp rate limits, prohibited operating zones, effect of steam valve and transmission losses. Also, the applied technique solves the optimum dispatch problem for microgrid considering the wind turbine as the renewable energy system. The emperor penguin optimization algorithm considers the huddling nature of emperor penguin to optimize the generation cost. The efficacy of the technique is verified for different test system with the comparison of other applied technique.
- 14 September 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (2) , 415-437
Fault Analysis of PI and Fuzzy-Logic-Controlled DFIG-based Grid-Connected Wind Energy Conversion System
- 14 September 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (2) , 415-437
Fault Analysis of PI and Fuzzy-Logic-Controlled DFIG-based Grid-Connected Wind Energy Conversion System
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 7 (3) , 240
Performance investigation of a Q-V-based Lyapunov finite time VSC control for grid interactive photovoltaic system
A photovoltaic (PV)-based voltage source converter (VSC) system, integrated with local load and utility grid is presented in this paper. The PV-VSC control hence considered on the reactive power (Q
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 7 (3) , 240
Performance investigation of a Q-V-based Lyapunov finite time VSC control for grid interactive photovoltaic system
A photovoltaic (PV)-based voltage source converter (VSC) system, integrated with local load and utility grid is presented in this paper. The PV-VSC control hence considered on the reactive power (Q
- 2 October 2015
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 12 (4) , 301-311
Finite-time sliding mode power control of grid-connected three-phase photovoltaic array
A new direct power control formulation for the voltage source converter (VSC) in a grid-connected photovoltaic (PV) array is discussed in this paper. Instead of controlling the direct- and quadrature-axis currents of the VSC through the use of a phase-locked loop system (PLL), the instantaneous real- and reactive-power components are used as control variables. This approach, therefore, does not take into account the unmodelled dynamics of the PLL resulting in a robust control of the active, reactive powers while maintaining the photovoltaic (PV) array voltage at a constant value. Further, the stability of the grid-connected PV array is enhanced by designing a Lyapunov’s function-based finite-time non-linear reactive power and dc-link voltage controller, which essentially uses the terminal sliding mode approach. To prove the robustness of the proposed approach, several system disturbances like changes in solar insolation and active and reactive power references, islanding conditions, converter parametric changes, and faults on the converter and inverter buses are considered. In all these cases, the new controller is found to enhance overall system stability in comparison to the inferior performance by the proportional-integral controller
- 2 October 2015
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 12 (4) , 301-311
Finite-time sliding mode power control of grid-connected three-phase photovoltaic array
A new direct power control formulation for the voltage source converter (VSC) in a grid-connected photovoltaic (PV) array is discussed in this paper. Instead of controlling the direct- and quadrature-axis currents of the VSC through the use of a phase-locked loop system (PLL), the instantaneous real- and reactive-power components are used as control variables. This approach, therefore, does not take into account the unmodelled dynamics of the PLL resulting in a robust control of the active, reactive powers while maintaining the photovoltaic (PV) array voltage at a constant value. Further, the stability of the grid-connected PV array is enhanced by designing a Lyapunov’s function-based finite-time non-linear reactive power and dc-link voltage controller, which essentially uses the terminal sliding mode approach. To prove the robustness of the proposed approach, several system disturbances like changes in solar insolation and active and reactive power references, islanding conditions, converter parametric changes, and faults on the converter and inverter buses are considered. In all these cases, the new controller is found to enhance overall system stability in comparison to the inferior performance by the proportional-integral controller
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 497-504
Islanding disclosure for grid interactive PV-VSC system using negative sequence voltage
This paper presents a new study on active islanding detection method for grid connected photovoltaic (PV) based voltage source converter (VSC) system. The VSC system is basically controlled by positive sequence P-Q loop, where point of common coupling (PCC) power components are measured parameters. But during grid disconnection an islanding detection loop is further implemented with existing control, based on negative sequence voltage ( neg dq V , ) at PCC. The threshold for the feedback sequence voltage is determined to maintain a negligible non detection zone (NDZ) and to avoid false detection during other power quality issues. Worst case scenario is considered by implementing a PV based VSC system from IEEE UL 1741 standard. Performance of the proposed islanding detection loop is investigated in MATLAB/ Simulink environment. The efficient detection of islanding with less than a cycle Run on time is ensured by the result analysis, where no significant effect in power quality during normal operating condition has been maintained.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 497-504
Islanding disclosure for grid interactive PV-VSC system using negative sequence voltage
This paper presents a new study on active islanding detection method for grid connected photovoltaic (PV) based voltage source converter (VSC) system. The VSC system is basically controlled by positive sequence P-Q loop, where point of common coupling (PCC) power components are measured parameters. But during grid disconnection an islanding detection loop is further implemented with existing control, based on negative sequence voltage ( neg dq V , ) at PCC. The threshold for the feedback sequence voltage is determined to maintain a negligible non detection zone (NDZ) and to avoid false detection during other power quality issues. Worst case scenario is considered by implementing a PV based VSC system from IEEE UL 1741 standard. Performance of the proposed islanding detection loop is investigated in MATLAB/ Simulink environment. The efficient detection of islanding with less than a cycle Run on time is ensured by the result analysis, where no significant effect in power quality during normal operating condition has been maintained.
- 1 July 2014
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 25 (6) , 699-719
Detection and Classification of Islanding and Nonislanding Events in Distributed Generation Based on Fuzzy Decision Tree
- 1 July 2014
- Published by Springer Nature in Journal of Control, Automation and Electrical Systems
- Vol. 25 (6) , 699-719
Detection and Classification of Islanding and Nonislanding Events in Distributed Generation Based on Fuzzy Decision Tree
- 1 March 2012
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 36 (1) , 18-30
Estimation of power quality indices in distributed generation systems during power islanding conditions
- 1 March 2012
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 36 (1) , 18-30
Estimation of power quality indices in distributed generation systems during power islanding conditions