MAMarina Gullo Augusto

Marina Gullo Augusto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marina Gullo Augusto has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adhesive Cementation of Glass-Fiber Posts: A Narrative Review of Materials and Techniques

    by Guilherme Schmitt de Andrade, Cassio Tsutomu Realino Higashibara, Carlos Eduardo Francci, Marina Gullo Augusto, Hagay Shemesh, João Paulo Mendes Tribst

    This review aims to synthesize current evidence-based protocols to guide clinicians toward predictable and durable adhesive cementation of glass-fiber posts in intraradicular dentin. Endodontically treated teeth (ETTs) frequently exhibit significant structural loss, requiring additional retention strategies, such as glass-fiber posts bonded with resin cements. Clinical outcomes depend on multiple factors, including adequate dentin substrate preparation, appropriate adhesive strategies, and precise cementation techniques. The presence of smear layer debris may compromise adhesion; therefore, effective cleaning protocols are essential to ensure a contaminant-free substrate. Surface treatments of glass-fiber posts may enhance chemical bonding by exposing glass fibers and improving silane coupling. The selection of resin cement systems must consider limitations related to light transmission, polymerization depth, and the adhesive strategy employed. Moisture control and proper solvent volatilization are critical to optimizing bond strength, as is the prevention of contamination during cement application. Techniques that minimize porosity improve cement homogeneity and reduce interfacial defects that may act as failure initiation sites. Furthermore, the choice of core build-up material plays an important role in restoration durability. Collectively, these considerations demonstrate the importance of material selection and clinical technique in achieving reliable adhesive cementation of glass-fiber posts.

  • Effect of combining aminomethacrylate and fluoride against erosive and abrasive challenges on enamel and dentin

    by Marina Gullo Augusto, Luis Felipe Oliveira da Silva, Giovanna Lotto, Tamires Maria de Andrade Santos, Idalina Vieira Aoki, Carlos Rocha Gomes Torres, Tais Scaramucci, Alessandra Bühler Borges

    This study evaluated the effect of solutions containing aminomethacrylate copolymer (AA) and sodium fluoride (F; 225 ppm F−) or fluoride plus stannous chloride (FSn; 225 ppm F−, 800 ppm Sn2+) against enamel and dentin erosion/abrasion. Solutions F, FSn, AA, F+AA, FSn+AA, and deionized water as negative control were tested. Bovine enamel and dentin specimens (n = 13/solution/substrate) underwent a set of erosion‐abrasion cycles (0.3% citric acid [5 min, 4×/day], human saliva [1 h, 4×/day], brushing [15 s, 2×/day], and treatments [2 min, 2×/day]) for each of five days. Initial enamel erosion was evaluated using Knoop microhardness after the first and second acid challenge on day 1, and surface loss with profilometry after day 5. KOH‐soluble fluoride was assessed. Data were analyzed with ANOVA/Tukey tests. The combination of fluoride and AA resulted in higher protection against enamel erosion, whereas this was not the case for the combination of AA and FSn. All treatments protected against enamel and dentin loss. The lowest surface loss values were observed with F+AA and FSn+AA. The polymer did not significantly influence the KOH‐soluble fluoride formation on enamel/dentin specimens. The aminomethacrylate copolymer effectively enhanced the efficacy of sodium fluoride against initial erosion and improved the control of enamel and dentin wear of F and FSn solutions.


  • Open Access

    Film-Forming Polymers for Tooth Erosion Prevention

    by Marina Gullo Augusto, Tais Scaramucci, Tiago Moreira Bastos Campos, Idalina Vieira Aoki, Nadine Schlueter, Alessandra Bühler Borges

    Different agents have been proposed to prevent the progression of acid induced dental substance losses, which are called erosive tooth wear (ETW), such as fluorides, calcium, and phosphate-based products; however, there is a need for a further increase in efficacy. Recently, the ability of polymers to interact with the tooth surface, forming acid resistant films, has come into the focus of research; nevertheless, there is still the need for a better understanding of their mode of action. Thus, this article provides an overview of the chemical structure of polymers, their mode of action, as well as the effect of their incorporation into oral care products, acid beverages, and antacid formulations, targeting the prevention of ETW. Recent evidence indicates that this may be a promising approach, however, additional studies are needed to confirm their efficacy under more relevant clinical conditions that consider salivary parameters such as flow rate, composition, and clearance. The standardization of methodological procedures such as acid challenge, treatment duration, and combination with fluorides is necessary to allow further comparisons between studies. In conclusion, film-forming polymers may be a promising cost-effective approach to prevent and control erosive demineralization of the dental hard tissue.


  • Open Access

    Comparison of Polishing Systems on the Surface Roughness of Resin Based Composites Containing Different Monomers

    by Marina Gullo Augusto, Guilherme Schmitt de Andrade, Ingrid Fernandes Mathias-Santamaria, Amanda Maria de Oliveira Dal Piva, João Paulo Mendes Tribst

    Changes in the organic matrix of composite resins have been proposed to improve their surface properties. However, polishing systems may perform differently in different materials. This study compared the effect of polishing systems on the surface roughness of four composite resins containing different resin monomers: Admira Fusion (nanohybrid containing pure ormocer), Aura Bulkfill (nanohybrid containing Bis-GMA, UDMA), Charisma Diamond (nanohybrid containing TCD-DI-HEA) and Vittra APS (nanofilled containing UDMA). Cylinders (N = 120, n = 10) were prepared from each material and the top surface of each specimen was grounded using a diamond finishing bur. Baseline measurements of surface roughness (Ra) were recorded using a contact profilometer and the specimens of each composite were divided into three subgroups according to the polishing system: one-step, two-step, three-step. Ra measurements were recorded also after polishing. Data were analyzed using three-way ANOVA and Tukey’s test (p < 0.05). The baseline roughness of all composites was significantly reduced after polishing (p < 0.001). The two-step polishing system provided the smoothest surface for Admira Fusion (0.0770 ± 0.0171) and Charisma (0.1091 ± 0.0090), whereas for Aura and Vittra no significantly differences were found for the three polishing systems tested. The surface smoothness seems to be more material dependent than step dependent, but all tested systems provided clinically acceptable results.


  • Bond Strength to Eroded Enamel and Dentin Using a Universal Adhesive System.

    by Fabiana Cares Frattes, Marina Gullo Augusto, Carlos Rocha Gomes Torres, Cesar Rogério Pucci, Alessandra Bühler Borges

    To evaluate the influence of previous acid etching on the bond strength of a self-etch universal adhesive system on sound and eroded enamel and dentin. Flat enamel and dentin surfaces were obtained from bovine incisors (n = 44) and divided into two groups according to the exposure to erosive conditions: sound (without erosion) and eroded (after erosive challenge with 0.3% citric acid, pH 2.6, 5 min, 4x/day, 5 days). Each group was then divided into two subgroups (n = 11) according to the application or not of 37% phosphoric acid before applying a universal self-etch adhesive. Single Bond universal adhesive (3M ESPE) was applied and composite blocks were built up using Amelogen Plus (Ultradent). Sticks (1 × 1 mm) were obtained and the microtensile bond strength (µTBS) was assessed using a universal testing machine at a speed of 1 mm/min. Data were analyzed with two-way ANOVA and Tukey's tests (p < 0.05). For enamel groups, significant differences were observed for erosive challenge (p = 0.034) and acid etching (p = 0.047), but not for the interaction between them (p = 0.182). The means ± SD (MPa) for the erosive conditions were: sound, 25.02 ± 5.82a; eroded, 28.45 ± 5.92b; and for acid etching: without, 24.89 ± 5.39a; with, 28.58 ± 6.23b (different superscript letters indicate significant differences). For dentin, both the erosive condition (p = 0.936) and acid pretreatment (p = 0.084), as well as their interaction (p = 0.107), did not affect the bond strength. The erosive challenge and previous acid etching significantly increased the bond strength of the tested universal adhesive to enamel but not to dentin.


  • Comparison of Different Dentin Pretreatment Protocols on the Bond Strength of Glass Fiber Post Using Self-etching Adhesive

    by Frederico C. Martinho, Claudio Antonio Talge Carvalho, Luciane D. Oliveira, Ana Júlia Farias de Lacerda, Ana Cláudia Carvalho Xavier, Marina Gullo Augusto, Rayssa Ferreira Zanatta, Cesar Rogerio Pucci


  • Evaluation of the Influence of the Nd:YAG Laser and Different Irrigants on the Bond Strength of the Adhesion of the Fiber Posts to Root Dentin using a Self-etching Adhesive System

    by Cesar Rogério Pucci, Carlos Rocha Gomes Torres, Cláudio Antonio Talge Carvalho, Ana Julia Farias Lacerda, Marina Gullo, Ana Claudia Carvalho Xavier, Frederico Canato Martinho


  • Open Access

    Influence of ultrasound and irrigant solutions on the bond strength of glass fiber posts to root canal dentine

    by Ana Júlia Farias Lacerda, Marina Augusto Gullo, Ana Claudia Carvalho Xavier, César Rogério Pucci, Cláudio Antonio Talge Carvalho, Maria Filomena Rocha Lima Huhtala

    Objective: Assessment of the influence of theultrasound and irrigant solutions on the bondstrength (BS) of glass fiber posts. Material andMethods: Sixty-six roots of bovine teeth standardizedat 16 mm were used. The roots were submitted to abiomechanical preparation up to size #80 Kerr file,with irrigation of 5ml of saline solution at everyfile change and then filled. The canals underwentpartial desobturation and were divided into 6 groupsaccording to the irrigant solution and the use ofultrasound prior to the post cementation: S – salinesolution; C – 2% chlorhexidine solution; H –2.5%sodium hypochlorite solution; US – saline solution+ ultrasound; UC – 2% chlorhexidine solution +ultrasound; UH – 2.5% sodium hypochlorite solution+ ultrasound. After the cementation of the posts, thespecimens were cut into 3 slices of 2 mm of thickness,perpendicular to its long axis. The samples weresubmitted to push-out test with crosshead speed of1 mm/min and load of 50kgf. The data obtainedwere submitted to ANOVA and Tukey test (level ofsignificance of 5%). Results: Groups C 7.77(±1.8)a,UC 7.82(±1.6)a, S 7.33(±2.2)a, US 6.16(±2.3)a, H5.43(±1.3)b, UH 5.01(±2.3)b values in Mpa. Onlythe irrigant solutions showed statistically significantdifferences (<0.05). Tukey test revealed smallerbond strength for the specimens treated with SodiumHypochlorite (b). Conclusions: The ultrasoundtreatment did not show significant differencecompared with the other groups; therefore, its usecan be indicated prior to the cementation of glassfiber posts without damage to the bond strength. Thesodium hypochlorite solution showed the smallest BSvalues compared with the other groups.