María Fuentes-Rubio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
María Fuentes-Rubio has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- José Joaquín Cerón
Interdisciplinary Laboratory of Clinical Analysis, Interlab-UMU, Regional Campus of International Excellence Campus Mare Nostrum, University of Murcia, 30100 Murcia, Spain
9 shared publications - Ana María Gutiérrez
BioVetMed Research Group, Department of Animal Medicine and Surgery, Veterinary School, Regional Campus of International Excellence (CEIR) Campus Mare Nostrum (CMN), University of Murcia, 30100 Murcia, Spain
6 shared publications - Damián Escribano
Salilab-UMU. Interdisciplinary Laboratory of Clinical Analysis (Interlab), Regional Campus of International Excellence Campus Mare Nostrum, University of Murcia, Murcia 30100, Spain
6 shared publications - Fernando Tecles
Salilab-UMU, Interdisciplinary Laboratory of Clinical Analysis, Veterinary School, Regional Campus of International Excellence ‘Campus Mare Nostrum’, University of Murcia
3 shared publications Julio Otal
Animal Science Department, School of Veterinary Medicine, University of Murcia, Murcia, Spain
3 shared publicationsAlberto Quiles
Animal Science Department, School of Veterinary Medicine, University of Murcia, Murcia, Spain
2 shared publications
Latest Publications
- 1 July 2016
- Vol. 80 (3) , 197-202
Validation of an assay for quantification of alpha-amylase in saliva of sheep.
The objective of this study was to develop a time-resolved immunofluorometric assay (TR-IFMA) for quantification of salivary alpha-amylase in sheep. For that purpose, after the design of the assay, an analytical and a clinical validation were carried out. The analytical validation of the assay showed intra- and inter-assay coefficients of variation (CVs) of 6.1% and 10.57%, respectively and an analytical limit of detection of 0.09 ng/mL. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution. For clinical validation, a model of acute stress testing was conducted to determine whether expected significant changes in alpha-amylase were picked up in the newly developed assay. In that model, 11 sheep were immobilized and confronted with a sheepdog to induce stress. Saliva samples were obtained before stress induction and 15, 30, and 60 min afterwards. Salivary cortisol was measured as a reference of stress level. The results of TR-IFMA showed a significant increase (P < 0.01) in the concentration of alpha-amylase in saliva after stress induction. The assay developed in this study could be used to measure salivary alpha-amylase in the saliva of sheep and this enzyme could be a possible noninvasive biomarker of stress in sheep.
- 1 July 2016
- Vol. 80 (3) , 197-202
Validation of an assay for quantification of alpha-amylase in saliva of sheep.
The objective of this study was to develop a time-resolved immunofluorometric assay (TR-IFMA) for quantification of salivary alpha-amylase in sheep. For that purpose, after the design of the assay, an analytical and a clinical validation were carried out. The analytical validation of the assay showed intra- and inter-assay coefficients of variation (CVs) of 6.1% and 10.57%, respectively and an analytical limit of detection of 0.09 ng/mL. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution. For clinical validation, a model of acute stress testing was conducted to determine whether expected significant changes in alpha-amylase were picked up in the newly developed assay. In that model, 11 sheep were immobilized and confronted with a sheepdog to induce stress. Saliva samples were obtained before stress induction and 15, 30, and 60 min afterwards. Salivary cortisol was measured as a reference of stress level. The results of TR-IFMA showed a significant increase (P < 0.01) in the concentration of alpha-amylase in saliva after stress induction. The assay developed in this study could be used to measure salivary alpha-amylase in the saliva of sheep and this enzyme could be a possible noninvasive biomarker of stress in sheep.
- 1 March 2015
- Published by Elsevier in Journal of Veterinary Behavior
- Vol. 10 (2) , 122-127
Measurements of salivary alpha-amylase in horse: Comparison of 2 different assays
- 1 March 2015
- Published by Elsevier in Journal of Veterinary Behavior
- Vol. 10 (2) , 122-127
Measurements of salivary alpha-amylase in horse: Comparison of 2 different assays
- 1 August 2014
- Published by Elsevier in Research in Veterinary Science
- Vol. 97 (1) , 20-25
Salivary testosterone measurements in growing pigs: validation of an automated chemiluminescent immunoassay and its possible use as an acute stress marker
- 1 August 2014
- Published by Elsevier in Research in Veterinary Science
- Vol. 97 (1) , 20-25
Salivary testosterone measurements in growing pigs: validation of an automated chemiluminescent immunoassay and its possible use as an acute stress marker
- 1 April 2014
- Vol. 78 (2) , 127-32
Porcine salivary analysis by 2-dimensional gel electrophoresis in 3 models of acute stress: a pilot study.
The purpose of this research was to study changes in the salivary proteome of healthy pigs in stressful situations to identify any potential new salivary biomarker of stress. Three groups of animals were subjected to 3 stress models: snaring restraint followed by simulated sampling of vena cava blood; brief transport by road; and restriction of movement in a digestibility cage. Saliva was obtained from each animal before and 15 and 30 min after the induction of stress. The samples from the animals that showed the greatest increase in salivary cortisol concentration were pooled and run on 2-dimensional gels. Coomassie Brilliant Blue R-250 was used for spot detection and mass spectrometry for spot identification. Statistical analyses showed that 2 proteins had significant differences in expression before and after the induction of stress. These proteins were identified as odorant-binding protein and fragments of albumin. Further studies will be necessary to confirm the value of using these proteins as salivary biomarkers of stress in pigs.
- 1 April 2014
- Vol. 78 (2) , 127-32
Porcine salivary analysis by 2-dimensional gel electrophoresis in 3 models of acute stress: a pilot study.
The purpose of this research was to study changes in the salivary proteome of healthy pigs in stressful situations to identify any potential new salivary biomarker of stress. Three groups of animals were subjected to 3 stress models: snaring restraint followed by simulated sampling of vena cava blood; brief transport by road; and restriction of movement in a digestibility cage. Saliva was obtained from each animal before and 15 and 30 min after the induction of stress. The samples from the animals that showed the greatest increase in salivary cortisol concentration were pooled and run on 2-dimensional gels. Coomassie Brilliant Blue R-250 was used for spot detection and mass spectrometry for spot identification. Statistical analyses showed that 2 proteins had significant differences in expression before and after the induction of stress. These proteins were identified as odorant-binding protein and fragments of albumin. Further studies will be necessary to confirm the value of using these proteins as salivary biomarkers of stress in pigs.
- 31 March 2014
- Published by Bentham Science Publishers Ltd. in Current Protein & Peptide Science
- Vol. 15 (1) , 56-63
A Proteomic Approach To Porcine Saliva
This paper reviews recent progress in salivary animal proteomics, with special reference to the porcine proteome. Until fairly recently, most studies on saliva as a diagnostic fluid have focused on humans, primates and rodents, and the development of salivary analysis in monitoring health in farm animals including pigs has received only limited consideration. The porcine salivary proteome has been characterised by 2D-electrophoresis followed by mass spectrometry. Major and minor proteins have been identified. The use of saliva as a non-invasive biological fluid in monitoring health and disease in pigs will be reviewed, together with the potential use of proteomics for the development of biomarkers. In this review, methods of collection and the composition of porcine saliva will be considered, together with saliva handling and analysis. The overall findings indicate that there is considerable potential for the development of salivary analysis as a non-invasive diagnostic fluid in the pig, and that it offers advantages over other body fluids in this animal.
- 31 March 2014
- Published by Bentham Science Publishers Ltd. in Current Protein & Peptide Science
- Vol. 15 (1) , 56-63
A Proteomic Approach To Porcine Saliva
This paper reviews recent progress in salivary animal proteomics, with special reference to the porcine proteome. Until fairly recently, most studies on saliva as a diagnostic fluid have focused on humans, primates and rodents, and the development of salivary analysis in monitoring health in farm animals including pigs has received only limited consideration. The porcine salivary proteome has been characterised by 2D-electrophoresis followed by mass spectrometry. Major and minor proteins have been identified. The use of saliva as a non-invasive biological fluid in monitoring health and disease in pigs will be reviewed, together with the potential use of proteomics for the development of biomarkers. In this review, methods of collection and the composition of porcine saliva will be considered, together with saliva handling and analysis. The overall findings indicate that there is considerable potential for the development of salivary analysis as a non-invasive diagnostic fluid in the pig, and that it offers advantages over other body fluids in this animal.
- 1 March 2014
- Published by Elsevier in The Veterinary Journal
- Vol. 199 (3) , 355-359
Saliva chromogranin A in growing pigs: A study of circadian patterns during daytime and stability under different storage conditions
- 1 March 2014
- Published by Elsevier in The Veterinary Journal
- Vol. 199 (3) , 355-359
Saliva chromogranin A in growing pigs: A study of circadian patterns during daytime and stability under different storage conditions
- 1 March 2014
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 41 (1) , 37-43
Assessment of Stress Associated with an Oral Public Speech in Veterinary Students by Salivary Biomarkers
In this report, salivary cortisol, alpha-amylase activity, and testosterone were measured to assess stress associated with a public oral presentation in Veterinary Clinical Pathology students. Stimulated saliva samples were collected before and directly after a 5-minute oral presentation and at 20 and 35 minutes after the beginning of the presentation. Cortisol peaked 20 minutes after the beginning of the presentation, whereas salivary alpha-amylase (sAA) peaked at 5 minutes, just at the end of the speech. These changes were not related to the level of stress that was indicated by the student in a questionnaire, the student's sex, or the quality of the presentation. No changes were detected in testosterone levels during the study. Saliva biomarkers evaluated in this research could be extended to other stress-producing situations in the university life of veterinary students.
- 1 March 2014
- Published by University of Toronto Press Inc. (UTPress) in Journal of Veterinary Medical Education
- Vol. 41 (1) , 37-43
Assessment of Stress Associated with an Oral Public Speech in Veterinary Students by Salivary Biomarkers
In this report, salivary cortisol, alpha-amylase activity, and testosterone were measured to assess stress associated with a public oral presentation in Veterinary Clinical Pathology students. Stimulated saliva samples were collected before and directly after a 5-minute oral presentation and at 20 and 35 minutes after the beginning of the presentation. Cortisol peaked 20 minutes after the beginning of the presentation, whereas salivary alpha-amylase (sAA) peaked at 5 minutes, just at the end of the speech. These changes were not related to the level of stress that was indicated by the student in a questionnaire, the student's sex, or the quality of the presentation. No changes were detected in testosterone levels during the study. Saliva biomarkers evaluated in this research could be extended to other stress-producing situations in the university life of veterinary students.
- 1 August 2013
- Published by Elsevier in Research in Veterinary Science
- Vol. 95 (1) , 298-302
Response of salivary haptoglobin and serum amyloid A to social isolation and short road transport stress in pigs
- 1 August 2013
- Published by Elsevier in Research in Veterinary Science
- Vol. 95 (1) , 298-302
Response of salivary haptoglobin and serum amyloid A to social isolation and short road transport stress in pigs
- 1 May 2013
- Published by Elsevier in The Veterinary Journal
- Vol. 196 (2) , 167-170
Circadian pattern of acute phase proteins in the saliva of growing pigs
- 1 May 2013
- Published by Elsevier in The Veterinary Journal
- Vol. 196 (2) , 167-170
Circadian pattern of acute phase proteins in the saliva of growing pigs
- 8 August 2012
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 24 (5) , 918-923
Validation of an automated chemiluminescent immunoassay for salivary cortisol measurements in pigs
The aim of the current study was to validate an automated immunoassay for cortisol quantification in the saliva of pigs. The assay had intra- and interassay coefficients of variation lower than 16%, in all cases. The limit of detection was 0.016 µg/dl, and the lower quantification limit was 0.197 µg/dl. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution and recovery tests. In addition, this assay was used to quantify cortisol in 2 models of stress: 1 in which animals were immobilized with a nose-snare and 1 in which pigs were transported for a duration of 30 min. In both cases, a significant increase ( P < 0.01) in salivary cortisol was detected after the stressful situation. Overall, the assay validated in the present study could be used for the evaluation of cortisol changes in stressful situations.
- 8 August 2012
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 24 (5) , 918-923
Validation of an automated chemiluminescent immunoassay for salivary cortisol measurements in pigs
The aim of the current study was to validate an automated immunoassay for cortisol quantification in the saliva of pigs. The assay had intra- and interassay coefficients of variation lower than 16%, in all cases. The limit of detection was 0.016 µg/dl, and the lower quantification limit was 0.197 µg/dl. The assay also demonstrated a high level of accuracy, as determined by linearity under dilution and recovery tests. In addition, this assay was used to quantify cortisol in 2 models of stress: 1 in which animals were immobilized with a nose-snare and 1 in which pigs were transported for a duration of 30 min. In both cases, a significant increase ( P < 0.01) in salivary cortisol was detected after the stressful situation. Overall, the assay validated in the present study could be used for the evaluation of cortisol changes in stressful situations.