YLYu-Hui Lo

Yu-Hui Lo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu-Hui Lo has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Anodal tDCS over right DLPFC does not improve visuospatial working memory in schizophrenia: a single-session, sham-controlled study

    by Shih-Chiang Ke, Philip Tseng, Hsiao-Lun Ku, Yu-Hui Lo, Ying-Ru Chen, Jiunn-Kae Wang

    Cognitive deficits, particularly in working memory (WM), significantly impair functional outcomes in schizophrenia (SCZ). Transcranial direct current stimu

  • Open Access

    Rapid biasing effect of prior auditory contexts on bistable tritone perception

    by Cheng-You Hou, Jyun-Jhe Wang, Yu-Hui Lo, Philip Tseng

    The tritone paradox is a bistable auditory phenomenon where two Shepard tones can be interpreted as either ascending or descending. Previous studies have demonstrated that preceding auditory context can bias the direction of tritone perception. Here, we systematically manipulated both the quantity (anywhere between 1 and 10) and types (higher, lower, same as first target tone, or silent) of context tones before presenting a target tritone pair. We found that the contextual biasing effect can emerge with as few as 1–2 context tones, and plateaus quickly within this small window. Notably, low-frequency context tones produced a more pronounced and immediate bias than high-frequency tones. Together, this study demonstrates a narrow window of the auditory context effect, where minimal contextual cues are sufficient to guide perceptual interpretation of ambiguous auditory stimuli. The findings pave the way for more detailed investigations into the cognitive mechanisms of auditory perception, emphasizing the swift influence of immediate auditory contexts on perceptual outcomes.


  • Theta burst entrainment of human EEG using flickering light stimulation

    by Yu-Hui Lo, Shih-Chiang Ke, Tzung-Te Chen, Hsin-Hui Tsao, Philip Tseng

    Noninvasive sensory stimulation holds great potential for enhancing cognition, as well as treating neurodegenerative and neuropsychiatric diseases/disorders. However, all attempts to date have only used one single frequency. In this study, we used sensory stimulation to deliver theta burst stimulation (TBS), a complex theta-gamma waveform that is known to be effective for modulating neural activities, enhancing cognition, and treating depression. We show that sensory stimulation can deliver TBS accurately, with EEG evidence.


  • Open Access

    Dual-light invisible 40 Hz flicker does not entrain human EEG

    by Yu-Hui Lo, Shih-Chiang Ke, Philip Tseng

    Invisible flicker stimulation (IFS) aim to deliver 40-Hz neural entrainment while eliminating discomfort, offering potential non-pharmacological, noninvasive, and in-home interventions for Alzheimer’s and dementia. However, these cognitive effects have never been validated with EEG. We assessed the M+ BrainCare light's ability to induce 40-Hz EEG entrainment under three conditions: direct IFS-viewing, indirect IFS-viewing, and stroboscopic control. In both IFS conditions, there was no significant 40-Hz EEG oscillations. In contrast, stroboscopic control elicited robust entrainment in all participants, propagating to frontal regions. These results question the neural efficacy of current IFS technologies, emphasizing the need for EEG validation in future studies.

  • The bidirectional effect of attention on gamma sensory stimulation: 40 Hz entrainment is weakened by externally-induced distraction but enhanced by internally-induced distraction

    by Shih-Chiang Ke, Yu-Hui Lo, Philip Tseng

    Background: Forty-hertz gamma sensory entrainment has been shown to influence neural oscillations, reduce amyloid-β plaques and tau phosphorylation, and improve cognitive functioning in Alzheimer's disease. However, the role of the user's attentional states in modulating this entrainment effect remains poorly understood. Objective: Here we manipulated users’ attentional state to investigate the effect of focused vs. distracted attention on 40 Hz entrainment. Methods: During 40 Hz auditory stimulation, participants’ attentional states were manipulated to 3 attentional conditions: (1) attentive (i.e., attention directed towards 40 Hz clicking sound), (2) internally distracted (attention directed towards memory/thought), and (3) externally distracted (i.e., attention directed towards a podcast interview that is overlaid with 40 Hz auditory stimulation). Results: We observed strong 40 Hz oscillation in the attentive condition, and even stronger oscillation in the internal distraction condition, but minimal activation in the external distraction condition. These patterns are possibly driven by internally-generated stochastic resonance in the internal distraction condition, and sensory competition in the external distraction condition. Conclusions: In real-world applications, researchers should exercise caution when introducing features aimed at minimizing user boredom and discomfort, as these may create sensory competition and reduce entrainment. Instead, features that guide users’ internal attention may offer a promising direction for future research and implementation. Large-scale studies that employ larger sample size and more diverse participant pool are warranted to verify the findings reported here for better market implementations of the 40 Hz sensory entrainment.


  • Invisible multi-luminaire 40 Hz flicker does not entrain human electroencephalography

    by Yu-Hui Lo, Shih-Chiang Ke, Philip Tseng

    Background: Multi-luminaire light stimulation is a novel technique based on luminance flicker with low modulation depth created by two spatially adjacent light sources aimed to deliver 40 Hz neural stimulation while reducing discomfort, offering potential non-pharmacological, noninvasive, and in-home interventions for Alzheimer's disease and dementia. However, these cognitive effects have never been validated with electroencephalography (EEG). Objective: In this study we aim to assess the ability of multi-luminaire light stimulation to evoke a 40 Hz EEG response under two conditions: direct viewing and indirect viewing. Methods: The M + BrainCare light by Delta Electronics was used in this study. Participants were stimulated either directly by looking at the light (direct viewing condition), or off of the reflection from a piece of paper to mimic everyday reading (indirect viewing condition). EEG power at 40 Hz from these conditions were compared to a positive control of 40 Hz luminance flicker with 100% modulation depth (stroboscopic flicker). Results: In both multi-luminaire conditions, there was no significant 40 Hz EEG oscillations. In contrast, stroboscopic control elicited robust entrainment in all participants, propagating to frontal regions. Conclusions: Our results question the efficacy of multi-luminaire technology, specifically the Delta M + BrainCare light, for evoking 40 Hz neural responses. Future studies involving multi-luminaire technology should pay special attention to EEG validation prior to making claims about neural oscillation and brain health.


  • Open Access

    Single-session gamma sensory stimulation entrains real-time electroencephalography but does not enhance perception, attention, short-term memory, or long-term memory

    by Cai-Syuan Wu, Ting-Xuan Lin, Yu-Hui Lo, Shih-Chiang Ke, Prangya Parimita Sahu, Philip Tseng

    Background: Studies have shown that gamma (40 Hz) audiovisual stimulation can enhance gamma oscillations and improve cognitive functioning in patients with Alzheimer's disease. However, despite promising long-term results, the efficacy of short-duration or single-session 40 Hz entrainment in humans has been questioned by behavioral studies that fail to find observable cognitive aftereffects, for two possible reasons: 1) lack of validated gamma entrainment, as most studies lacked concurrent electroencephalography (EEG) data to verify that gamma neural entrainment did take place, and 2) lack of diverse cognitive tests, as most studies did not test a wide range of cognitive factors. Objective: This study aimed to increase sensitivity for detecting single-session gamma entrainment. We employed 1) mid- and post-stimulation EEG monitoring to ensure entrainment worked, and 2) a comprehensive cognitive battery that probes perception, attention, working memory, and long-term memory. Methods: Participants received 30 min of synchronized 40 Hz light and sound stimulation, followed by a visual perceptual task, attentional network task, change detection working memory task, and long-term picture memory task, with concurrent EEG. Results: We observed robust 40 Hz EEG entrainment during stimulation but no significant 40 Hz oscillation after stimulation, and no significant cognitive improvements. Conclusions: Despite robust 40 Hz online entrainment, gamma sensory entrainment requires consistent long-term exposure to induce cognitive and neurological changes. Future research should determine the optimal duration and frequency of 40 Hz stimulation to maximize its therapeutic potential.


  • Open Access

    Enhancing visual working memory in schizophrenia: effects of frontoparietal theta tACS in low-performing patients

    by Jiunn-Kae Wang, Prangya Parimita Sahu, Hsiao-Lun Ku, Yu-Hui Lo, Ying-Ru Chen, Che-Yin Lin, Philip Tseng

    Schizophrenia is a complex neuro-psychiatric disorder including positive symptoms, negative symptoms, and cognitive deficits. A key cognitive dysfunction in schizophrenia is a deficit in visual working memory (VWM). VWM involves three distinct stages: encoding, maintenance, and retrieval. The deficit in any one stage would produce the same symptom (i.e., poor VWM), although their causes are not the same. In this study, we used a retro-cue VWM task that provides helpful cues at different stages: early in maintenance (early cue), late in maintenance (late cue), or during retrieval (retrieval cue). This modification would help “tag” or identify the cognitive stage(s) most responsible for impaired VWM performance in schizophrenia. Additionally, we took advantage of this tagging feature and applied 6 Hz transcranial alternating current stimulation (tACS) over the right dorsolateral prefrontal cortex (DLPFC) and right posterior parietal cortex (PPC)—which has previously been shown to enhance VWM in low-performing healthy individuals—to examine whether tACS would improve a specific stage or all stages of VWM processing in schizophrenia. We observed that cues significantly enhanced performance in low-performing patients, who benefited equally from early and late maintenance cues, but not from retrieval cues. These low-performers also responded well to theta tACS in their overall VWM performance as opposed to a specific VWM stage. No improvement effect was observed in high-performing patients for both retro cue and tACS. Together, our data suggest that 1) low-performing patients’ VWM deficits likely stem from poor memory consolidation rather than retrieval, 2) right frontoparietal theta tACS can improve low-performing patients’ VWM performance, and 3) such facilitatory tACS effect is not selective of a specific VWM stage and thus is likely driven by an improvement in overall visual attention.


  • Open Access

    A survey of experimental stimulus presentation code sharing in major areas of psychology

    by Amit Rawal, Vuong Truong, Yu-Hui Lo, Lin-Yuan Tseng, Niall W Duncan

    Computer code plays a vital role in modern science, from the conception and design of experiments through to final data analyses. Open sharing of code has been widely discussed as being advantageous to the scientific process, allowing experiments to be more easily replicated, helping with error detection, and reducing wasted effort and resources. In the case of psychology, the code used to present stimuli is a fundamental component of many experiments. It is not known, however, the degree to which researchers are sharing this type of code.To estimate this, we conducted a survey of 400 psychology papers published between 2016 and 2021, identifying those that openly share stimulus presentation code. For those that did, we established if it would run following download and also appraised the code’s usability in terms of style and documentation.It was found that only 8.4% of papers shared stimulus code, compared to 17.9% sharing analysis code and 31.7% sharing data. Of shared code, 70% ran directly or after minor corrections. For code that did not run, the main error was missing dependencies (66.7%). The usability of the code was moderate, with low levels of code annotation and minimal documentation provided.These results suggest that stimulus presentation code sharing lags behind other forms of code and data sharing, potentially due to less emphasis such code in open-science discussions and in journal policies. They also highlight a need for improved documentation to maximise code utility.

  • Open Access

    Variation of picture angles and its effect on the Concealed Information Test

    by Ann Hsu, Yu-Hui Lo, Shi-Chiang Ke, Lin Lin, Philip Tseng

    Background: The reaction time-based Concealed Information Test (RT-CIT) is a memory paradigm used to detect crime-related knowledge. However, this would also imply that the RT-CIT would be vulnerable to factors that are known to compromise object recognition or memory integrity. From this perspective, one key issue is whether “guilty” memory can be detected if the crime-related images are photographed at different angles from what the perpetrator saw, which is almost always the case in the field. To investigate this, here we manipulated the deviation angles, from 0° to 330° in 11 steps, between the study and test phases to assess how the RT-CIT holds up against angular rotations. Results: We observed a robust RT-CIT effect at all deviation angles for both deep-encoders (Experiment 1) and shallow-encoders (Experiment 2). The RT-CIT was effective within the first 250 or so trials for both encoding groups, with smaller probe-irrelevant differences beyond that. Conclusions: With appropriate encoding and memory strength, RT-CIT images do not necessarily have to match the exact angle of the perpetrator’s perspective at the time of the crime. Unnatural angles such as 90° and 270° or unconventional rotational axes may require caution. Trial number under 250 trials show maximal Probe-Irrelevant difference, but more trials may add power to improve detection accuracy.