Guido Nannini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guido Nannini has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Alberto Redaelli
Department of Electronics Information and Bioengineering, Politecnico di Milano, Milan, Italy
5 shared publicationsSimone Saitta
Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam, The Netherlands; Informatics Institute, University of Amsterdam, Amsterdam, The Netherlands
5 shared publications- Alberto Redaelli
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
3 shared publications - Andrea Baggiano
Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino, IRCCS, 20138 Milan, Italy
3 shared publications - Gianluca Pontone
Centro Cardiologico Monzino, IRCCS, 20138 Milan, Italy
3 shared publications Jonathan W. Weinsaft
Department of Medicine (Cardiology), Weill Cornell College, New York, NY, United States of America
3 shared publications
Latest Publications
- Open Access
- 8 August 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108990
A personalized computational framework for the diagnosis of cardiac perfusion defects
- 8 August 2025
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 271, 108990
Open AccessA personalized computational framework for the diagnosis of cardiac perfusion defects
- Open Access
- 18 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110477
Learning hemodynamic scalar fields on coronary artery meshes: A benchmark of geometric deep learning models
- 18 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110477
Open AccessLearning hemodynamic scalar fields on coronary artery meshes: A benchmark of geometric deep learning models
- Open Access
- 5 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 190, 110084
Deployment of a digital twin using the coupled momentum method for fluid–structure interaction: A case study for aortic aneurysm
- 5 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 190, 110084
Open AccessDeployment of a digital twin using the coupled momentum method for fluid–structure interaction: A case study for aortic aneurysm
- Open Access
Pericoronary adipose tissue attenuation as a predictor of functional severity of coronary stenosis
Objective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid dynamics (CFD) simulations from a prior study. Centerlines of the main epicardial branches were automatically extracted, and lesions identified using Gaussian kernel regression to estimate healthy branch caliber. PCAT features were computed per vessel following guideline recommendations and per lesion within a region extending radially for two vessel radii. Features like fat volume and mean attenuation (FAI) were analyzed for their relationship with CFD-derived hemodynamic biomarkers, such as fractional flow reserve (FFR) and wall shear stress (WSS). These features also informed a machine learning (ML) model for classifying potentially ischemic lesions. Results: PCAT exhibited, on average, higher attenuation in the presence of hemodynamically significant lesions (i.e., FFR < 0.80), although this difference was of limited statistical significance. The ML classifier, trained on PCAT features, successfully distinguished potentially ischemic lesions, yielding average accuracy of 0.84. Conclusion: PCAT attenuation is correlated with the functional status of coronary stenosis and can be used to inform ML models for predicting potential ischemia. Significance: PCAT features, readily available from CCTA, can be used to predict the hemodynamic characteristics of a lesion without the need for an invasive FFR examination.
Open AccessPericoronary adipose tissue attenuation as a predictor of functional severity of coronary stenosis
Objective: This study aims to evaluate the functional significance of coronary stenosis by analyzing low-level radiomic features of the pericoronary adipose tissue (PCAT) surrounding the lesions, which are indicative of its inflammation status. Methods: A dataset of 72 patients who underwent coronary computed tomography angiography (CCTA) was analyzed, with 3D segmentation and computational fluid dynamics (CFD) simulations from a prior study. Centerlines of the main epicardial branches were automatically extracted, and lesions identified using Gaussian kernel regression to estimate healthy branch caliber. PCAT features were computed per vessel following guideline recommendations and per lesion within a region extending radially for two vessel radii. Features like fat volume and mean attenuation (FAI) were analyzed for their relationship with CFD-derived hemodynamic biomarkers, such as fractional flow reserve (FFR) and wall shear stress (WSS). These features also informed a machine learning (ML) model for classifying potentially ischemic lesions. Results: PCAT exhibited, on average, higher attenuation in the presence of hemodynamically significant lesions (i.e., FFR < 0.80), although this difference was of limited statistical significance. The ML classifier, trained on PCAT features, successfully distinguished potentially ischemic lesions, yielding average accuracy of 0.84. Conclusion: PCAT attenuation is correlated with the functional status of coronary stenosis and can be used to inform ML models for predicting potential ischemia. Significance: PCAT features, readily available from CCTA, can be used to predict the hemodynamic characteristics of a lesion without the need for an invasive FFR examination.
- Open Access
Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm
Introduction: Dacron graft replacement is the standard therapy for ascending aorta aneurysm, involving the insertion of a prosthesis with lower compliance than native tissue, which can alter downstream hemodynamics and lead to adverse remodeling. Digital human twins (DHT), based on in-silico models, have the potential to predict biomarkers of adverse outcome and aid in designing optimal treatments tailored to the individual patient. Objective: We propose a pipeline for deploying a digital human twin of the thoracic aorta to explore alternative solutions to traditional Dacron grafting, utilizing more compliant prostheses for reconstructing the ascending aorta. Methods: We propose a DHT based on fluid-structure interaction (FSI) analysis of the thoracic aorta. We create 3 models of the patient, representing: i) the pre-operative baseline, ii) the post-operative with Dacron graft, and iii) a virtual post-operative using a compliant fibrous prosthesis. 3D geometry of the thoracic aorta for a patient with a congenital aneurysm, before and after the surgery, were reconstructed from magnetic resonance imaging (MRI). As inlet boundary condition (BC), we assigned a time-varying 3D velocity profile extrapolated from 4D flow MRI. For the outlet BCs, we coupled 0D Winkler models, tuned to match the flow rate measured in the descending aorta from 4D flow. The aortic wall and the prosthetic graft were modeled as hyperelastic materials using the Holzapfel-Gasser constitutive model and tuned to patients distensibility. FSI analysis was run for two cardiac cycles. Results: Results were validated against 4D flow data. Quantitative comparison of outflows between FSI and 4D flow yielded relative squared errors of 5.28% and 0.33% for models (i) and (ii), respectively. Wall shear stress (WSS) and strain increased in both post-surgical scenarios (ii) and (iii) compared to (i), with a lower increase observed in the virtual scenario (iii) (p¡0.001). However, the difference between scenarios (iii) and (ii) remained moderate on average (e.g., 0.6 Pa for WSS). Conclusions: FSI analysis enables the deployment of reliable thoracic aorta DHTs to predict the impact of prostheses with different distensibility. Results indicate moderate yet promising benefits of more compliant fibrous devices on distal hemodynamics. Graphical Highlights: The coupled momentum method for fluid-structure interaction analysis can be used to deploy a high fidelity digital twin of the aorta Dacron graft induces an altered hemodynamic state in the descending aorta after ascending aorta correction. Electrowriting can be used to fabricate more compliant grafts that mitigate the adverse effect of Dacron in the descending aorta. The stress induced by a 2-folds more compliant (with respect to Dacron) graft is significantly lower Despite the difference being relevant, it is moderate (1 Pa).
Open AccessDeployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm
Introduction: Dacron graft replacement is the standard therapy for ascending aorta aneurysm, involving the insertion of a prosthesis with lower compliance than native tissue, which can alter downstream hemodynamics and lead to adverse remodeling. Digital human twins (DHT), based on in-silico models, have the potential to predict biomarkers of adverse outcome and aid in designing optimal treatments tailored to the individual patient. Objective: We propose a pipeline for deploying a digital human twin of the thoracic aorta to explore alternative solutions to traditional Dacron grafting, utilizing more compliant prostheses for reconstructing the ascending aorta. Methods: We propose a DHT based on fluid-structure interaction (FSI) analysis of the thoracic aorta. We create 3 models of the patient, representing: i) the pre-operative baseline, ii) the post-operative with Dacron graft, and iii) a virtual post-operative using a compliant fibrous prosthesis. 3D geometry of the thoracic aorta for a patient with a congenital aneurysm, before and after the surgery, were reconstructed from magnetic resonance imaging (MRI). As inlet boundary condition (BC), we assigned a time-varying 3D velocity profile extrapolated from 4D flow MRI. For the outlet BCs, we coupled 0D Winkler models, tuned to match the flow rate measured in the descending aorta from 4D flow. The aortic wall and the prosthetic graft were modeled as hyperelastic materials using the Holzapfel-Gasser constitutive model and tuned to patients distensibility. FSI analysis was run for two cardiac cycles. Results: Results were validated against 4D flow data. Quantitative comparison of outflows between FSI and 4D flow yielded relative squared errors of 5.28% and 0.33% for models (i) and (ii), respectively. Wall shear stress (WSS) and strain increased in both post-surgical scenarios (ii) and (iii) compared to (i), with a lower increase observed in the virtual scenario (iii) (p¡0.001). However, the difference between scenarios (iii) and (ii) remained moderate on average (e.g., 0.6 Pa for WSS). Conclusions: FSI analysis enables the deployment of reliable thoracic aorta DHTs to predict the impact of prostheses with different distensibility. Results indicate moderate yet promising benefits of more compliant fibrous devices on distal hemodynamics. Graphical Highlights: The coupled momentum method for fluid-structure interaction analysis can be used to deploy a high fidelity digital twin of the aorta Dacron graft induces an altered hemodynamic state in the descending aorta after ascending aorta correction. Electrowriting can be used to fabricate more compliant grafts that mitigate the adverse effect of Dacron in the descending aorta. The stress induced by a 2-folds more compliant (with respect to Dacron) graft is significantly lower Despite the difference being relevant, it is moderate (1 Pa).
- Open Access
- 6 September 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 257, 108415
An automated and time-efficient framework for simulation of coronary blood flow under steady and pulsatile conditions
- 6 September 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 257, 108415
Open AccessAn automated and time-efficient framework for simulation of coronary blood flow under steady and pulsatile conditions
- Open Access
- 23 January 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (1) , 016103
A fully automated deep learning approach for coronary artery segmentation and comprehensive characterization
Coronary computed tomography angiography (CCTA) allows detailed assessment of early markers associated with coronary artery disease (CAD), such as coronary artery calcium (CAC) and tortuosity (CorT). However, their analysis can be time-demanding and biased. We present a fully automated pipeline that performs (i) coronary artery segmentation and (ii) CAC and CorT objective analysis. Our method exploits supervised learning for the segmentation of the lumen, and then, CAC and CorT are automatically quantified. 281 manually annotated CCTA images were used to train a two-stage U-Net-based architecture. The first stage employed a 2.5D U-Net trained on axial, coronal, and sagittal slices for preliminary segmentation, while the second stage utilized a multichannel 3D U-Net for refinement. Then, a geometric post-processing was implemented: vessel centerlines were extracted, and tortuosity score was quantified as the count of branches with three or more bends with change in direction forming an angle >45°. CAC scoring relied on image attenuation. CAC was detected by setting a patient specific threshold, then a region growing algorithm was applied for refinement. The application of the complete pipeline required <5 min per patient. The model trained for coronary segmentation yielded a Dice score of 0.896 and a mean surface distance of 1.027 mm compared to the reference ground truth. Tracts that presented stenosis were correctly segmented. The vessel tortuosity significantly increased locally, moving from proximal, to distal regions (p < 0.001). Calcium volume score exhibited an opposite trend (p < 0.001), with larger plaques in the proximal regions. Volume score was lower in patients with a higher tortuosity score (p < 0.001). Our results suggest a linked negative correlation between tortuosity and calcific plaque formation. We implemented a fast and objective tool, suitable for population studies, that can help clinician in the quantification of CAC and various coronary morphological parameters, which is helpful for CAD risk assessment.
- 23 January 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (1) , 016103
Open AccessA fully automated deep learning approach for coronary artery segmentation and comprehensive characterization
Coronary computed tomography angiography (CCTA) allows detailed assessment of early markers associated with coronary artery disease (CAD), such as coronary artery calcium (CAC) and tortuosity (CorT). However, their analysis can be time-demanding and biased. We present a fully automated pipeline that performs (i) coronary artery segmentation and (ii) CAC and CorT objective analysis. Our method exploits supervised learning for the segmentation of the lumen, and then, CAC and CorT are automatically quantified. 281 manually annotated CCTA images were used to train a two-stage U-Net-based architecture. The first stage employed a 2.5D U-Net trained on axial, coronal, and sagittal slices for preliminary segmentation, while the second stage utilized a multichannel 3D U-Net for refinement. Then, a geometric post-processing was implemented: vessel centerlines were extracted, and tortuosity score was quantified as the count of branches with three or more bends with change in direction forming an angle >45°. CAC scoring relied on image attenuation. CAC was detected by setting a patient specific threshold, then a region growing algorithm was applied for refinement. The application of the complete pipeline required <5 min per patient. The model trained for coronary segmentation yielded a Dice score of 0.896 and a mean surface distance of 1.027 mm compared to the reference ground truth. Tracts that presented stenosis were correctly segmented. The vessel tortuosity significantly increased locally, moving from proximal, to distal regions (p < 0.001). Calcium volume score exhibited an opposite trend (p < 0.001), with larger plaques in the proximal regions. Volume score was lower in patients with a higher tortuosity score (p < 0.001). Our results suggest a linked negative correlation between tortuosity and calcific plaque formation. We implemented a fast and objective tool, suitable for population studies, that can help clinician in the quantification of CAC and various coronary morphological parameters, which is helpful for CAD risk assessment.
- 1 August 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 135, 104581
Aortic hemodynamics assessment prior and after valve sparing reconstruction: A patient-specific 4D flow-based FSI model
- 1 August 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 135, 104581
Aortic hemodynamics assessment prior and after valve sparing reconstruction: A patient-specific 4D flow-based FSI model