Pascal Mottier
Research Subjects
Pascal Mottier has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Bessaire
A Nestlé Research Center , Institute of Food Safety and Analytical Science , Lausanne , Switzerland
17 shared publications Eric Gremaud
Nestlé Research Centre, Nestec Ltd., Vers-chez-les-Blanc, 1000 Lausanne 26, Switzerland
11 shared publications- Aurélien Desmarchelier
A Nestlé Research Center , Institute of Food Safety and Analytical Science , Lausanne , Switzerland
9 shared publications - Thierry Delatour
Société des Produits Nestlé S.A., Nestlé Research, Vers-chez-les-Blanc, CH-1000 Lausanne 26, Switzerland
8 shared publications Adrienne Tarres
A Nestlé Research , Institute of Food Safety and Analytical Science , Lausanne , Switzerland
7 shared publicationsPhilippe A. Guy
Nestlé Research Center, Nestec Ltd., P.O. Box 44, Vers-Chez-Les-Blanc, 1000 Lausanne 26, Switzerland, MIP Technologies, Scheelevlägen 22, Box 737, 22007 Lund, Sweden, and Laboratoire de Chimie Structurale Organique et Biologique, CNRS UMR 7613, University Pierre & Marie Curie, 4 Place Jussieu, 75252 Paris cedex 05, France
7 shared publications
Latest Publications
- 11 June 2026
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
LC–MS/MS method for per- and polyfluoroalkyl substances (PFAS) analysis in food products, First Action 2025.10
Background: Per- and polyfluoroalkyl substances (PFAS) are synthetic compounds widely used due to their water, grease, and dirt repellent properties. They are persistent and resistant to degradation, therefore they can be found in the environment, the food chain, and in human fluids. The European Union (EU) has established LOQs for four PFAS in produce, seafood, meat, eggs, fish oil, milk, and ready-to-eat food for infants and young children and set maximum levels (MLs) for the same analytes in eggs, fish, and meat products. Objective: The study describes a quantitative LC–MS/MS method for the determination of 57 PFAS in food. The 55 analytes are quantified by isotopic dilution while two of the compounds, namely Capstone A and Capstone B are quantified using two-level standard addition. Seven of the compounds have only one transition, which need another technique for their confirmation in case of a positive result in a sample. The scope comprises analytes included in the AOAC INTERNATIONAL Standard Method Performance Requirements (SMPR®) 2023.003, cited in the EU Recommendation 2022/1431, and analytes surveyed by service laboratories in Europe or mentioned in the literature. Representative samples from several food categories (baby food puree, milk-based infant formula [powder], full-cream milk powder, fish meat and fish oil, whole egg, soluble coffee, pet food and edible offal) were validated. Targeted performance requirements for LOQ, recovery, and precision were as defined per SMPR 2023.003. Methods: The protocol involves an acetonitrile/water extraction. For 55 PFAS analysis in all matrices, a solid-phase extraction (SPE) method is applied. Detection is conducted by LC-MS/MS and isotopic dilution is applied for quantification. Confirmation for single-transition analysis is performed by LC–high-resolution MS (HRMS). For infant formula and baby food, the extract is diverted to two workflows, one for the 55 PFAS and one for Capstone A and Capstone B, where a diluted aliquot is analyzed by LC–MS/MS and quantified by the standard addition procedure. Results: The method was single-laboratory validated in the nine food matrices with results generally in agreement with the criteria of SMPR 2023.003, in terms of LOQs, recovery, and precision. LOQs were generally in the low ng/kg range, and recoveries typically fell within 70–120%, with acceptable repeatability and intermediate precision. The performance of the method was further demonstrated by analyzing 27 additional food matrices. Conclusion: The method described covers a wide range of food matrices and analytes and compares favorably with most of the requirements of SMPR 2023.003. It contains as well a larger scope of analytes compared to SMPR 2023.003, giving an advantage in searching other potential sources of PFAS contamination. Following independent scientific review, the AOAC Expert Review Panel for PFAS in Food Methods determined that the method met the requirements of AOAC SMPR 2023.003 and approved it for First Action status as AOAC Official MethodSM 2025.10. Highlights: This work presents a validated LC–MS/MS method for 57 PFAS across diverse food matrices, meeting or exceeding most of the SMPR 2023.003 performance requirements and demonstrating broad applicability for routine monitoring. The method includes additional PFAS of emerging interest and was approved for First Action status, designated AOAC Official Method 2025.10.
- 11 June 2026
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
LC–MS/MS method for per- and polyfluoroalkyl substances (PFAS) analysis in food products, First Action 2025.10
Background: Per- and polyfluoroalkyl substances (PFAS) are synthetic compounds widely used due to their water, grease, and dirt repellent properties. They are persistent and resistant to degradation, therefore they can be found in the environment, the food chain, and in human fluids. The European Union (EU) has established LOQs for four PFAS in produce, seafood, meat, eggs, fish oil, milk, and ready-to-eat food for infants and young children and set maximum levels (MLs) for the same analytes in eggs, fish, and meat products. Objective: The study describes a quantitative LC–MS/MS method for the determination of 57 PFAS in food. The 55 analytes are quantified by isotopic dilution while two of the compounds, namely Capstone A and Capstone B are quantified using two-level standard addition. Seven of the compounds have only one transition, which need another technique for their confirmation in case of a positive result in a sample. The scope comprises analytes included in the AOAC INTERNATIONAL Standard Method Performance Requirements (SMPR®) 2023.003, cited in the EU Recommendation 2022/1431, and analytes surveyed by service laboratories in Europe or mentioned in the literature. Representative samples from several food categories (baby food puree, milk-based infant formula [powder], full-cream milk powder, fish meat and fish oil, whole egg, soluble coffee, pet food and edible offal) were validated. Targeted performance requirements for LOQ, recovery, and precision were as defined per SMPR 2023.003. Methods: The protocol involves an acetonitrile/water extraction. For 55 PFAS analysis in all matrices, a solid-phase extraction (SPE) method is applied. Detection is conducted by LC-MS/MS and isotopic dilution is applied for quantification. Confirmation for single-transition analysis is performed by LC–high-resolution MS (HRMS). For infant formula and baby food, the extract is diverted to two workflows, one for the 55 PFAS and one for Capstone A and Capstone B, where a diluted aliquot is analyzed by LC–MS/MS and quantified by the standard addition procedure. Results: The method was single-laboratory validated in the nine food matrices with results generally in agreement with the criteria of SMPR 2023.003, in terms of LOQs, recovery, and precision. LOQs were generally in the low ng/kg range, and recoveries typically fell within 70–120%, with acceptable repeatability and intermediate precision. The performance of the method was further demonstrated by analyzing 27 additional food matrices. Conclusion: The method described covers a wide range of food matrices and analytes and compares favorably with most of the requirements of SMPR 2023.003. It contains as well a larger scope of analytes compared to SMPR 2023.003, giving an advantage in searching other potential sources of PFAS contamination. Following independent scientific review, the AOAC Expert Review Panel for PFAS in Food Methods determined that the method met the requirements of AOAC SMPR 2023.003 and approved it for First Action status as AOAC Official MethodSM 2025.10. Highlights: This work presents a validated LC–MS/MS method for 57 PFAS across diverse food matrices, meeting or exceeding most of the SMPR 2023.003 performance requirements and demonstrating broad applicability for routine monitoring. The method includes additional PFAS of emerging interest and was approved for First Action status, designated AOAC Official Method 2025.10.
- 9 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (1) , 99-117
Simultaneous and Quantitative Determination of Pyrrolizidine and Tropane Alkaloids in Food by LC-MS/MS, First Action 2025.02
Background: Pyrrolizidine alkaloids (PAs) are natural toxins produced by >6000 flowering plant species. Some PAs are hepatotoxic and genotoxic carcinogens. Reported cases of direct poisoning in humans have already been documented, but the highest risk of human exposure occurs through the consumption of crops contaminated with PA-producing weeds. The European Commission Regulation EU 2023/915 set maximum levels (MLs) for the sum of 35 PAs in tea, herbal teas, herbs, and spice seeds at levels ranging from 75 to 1000 µg/kg (dry matter basis). Objective: The study describes the performance characteristics of a quantitative liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the determination of the 35 PAs mentioned in AOAC INTERNATIONAL Standard Method Performance Requirement (SMPR®) 2023.002 in tea, herbal infusions, herbs, seed spices, cereals, and honey. The analyte scope also comprised nine additional PAs along with two tropane alkaloids (TAs; namely, atropine and scopolamine) for which MLs are also set in plant-based products in the European Union (EU 2023/915). Method: The protocol involves an extraction of toxins from food using aqueous sulfuric acid followed by solid-phase extraction purification. After elution and evaporation to dryness, the residue is reconstituted in a water–methanol solution before LC-MS/MS analysis. Alkaline mobile phases are used to favor the separation of isomers. Identification of the analytes is conducted according to the confirmation criteria defined in EU 2023/2783 and SANTE 11312/2021v2 documents. Quantification is performed by isotopic dilution using four isotopically labeled PAs and two isotopically labeled TAs as internal standards. Results: Method validation workload was shared by three different laboratories on representative matrixes from the following commodities: dried herbs, dried tea, dried herbal infusions, seed spices, cereals, and honey. The 35 target analytes specifically listed in the AOAC SMPR 2023.002 have been successfully validated (recovery 70–120%, repeatability <20%, intermediate reproducibility <20%), allowing LOQs down to 1 µg/kg. Conclusions: The performances of the method are in agreement with criteria defined in AOAC SMPR 2023.002. Highlights: The Expert Review Panel for Pyrrolizidine Alkaloids approved the present method as AOAC Official First Action 2025.02.
- 9 October 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (1) , 99-117
Simultaneous and Quantitative Determination of Pyrrolizidine and Tropane Alkaloids in Food by LC-MS/MS, First Action 2025.02
Background: Pyrrolizidine alkaloids (PAs) are natural toxins produced by >6000 flowering plant species. Some PAs are hepatotoxic and genotoxic carcinogens. Reported cases of direct poisoning in humans have already been documented, but the highest risk of human exposure occurs through the consumption of crops contaminated with PA-producing weeds. The European Commission Regulation EU 2023/915 set maximum levels (MLs) for the sum of 35 PAs in tea, herbal teas, herbs, and spice seeds at levels ranging from 75 to 1000 µg/kg (dry matter basis). Objective: The study describes the performance characteristics of a quantitative liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the determination of the 35 PAs mentioned in AOAC INTERNATIONAL Standard Method Performance Requirement (SMPR®) 2023.002 in tea, herbal infusions, herbs, seed spices, cereals, and honey. The analyte scope also comprised nine additional PAs along with two tropane alkaloids (TAs; namely, atropine and scopolamine) for which MLs are also set in plant-based products in the European Union (EU 2023/915). Method: The protocol involves an extraction of toxins from food using aqueous sulfuric acid followed by solid-phase extraction purification. After elution and evaporation to dryness, the residue is reconstituted in a water–methanol solution before LC-MS/MS analysis. Alkaline mobile phases are used to favor the separation of isomers. Identification of the analytes is conducted according to the confirmation criteria defined in EU 2023/2783 and SANTE 11312/2021v2 documents. Quantification is performed by isotopic dilution using four isotopically labeled PAs and two isotopically labeled TAs as internal standards. Results: Method validation workload was shared by three different laboratories on representative matrixes from the following commodities: dried herbs, dried tea, dried herbal infusions, seed spices, cereals, and honey. The 35 target analytes specifically listed in the AOAC SMPR 2023.002 have been successfully validated (recovery 70–120%, repeatability <20%, intermediate reproducibility <20%), allowing LOQs down to 1 µg/kg. Conclusions: The performances of the method are in agreement with criteria defined in AOAC SMPR 2023.002. Highlights: The Expert Review Panel for Pyrrolizidine Alkaloids approved the present method as AOAC Official First Action 2025.02.
- 16 April 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (4) , 617-631
Screening of 152 Veterinary Drug Residues in Animal Source Foods by LC–MS/MS, Multilaboratory Validation Study: Final Action 2020.04
The presence of veterinary drug residues in food-producing animals and animal products is regulated through the enforcement of maximum residue limits (MRLs). To answer the need of the food sector to monitor these substances in a wide range of food commodities, stakeholders at AOAC identified the need for a reliable confirmatory screening method. Such qualitative approach is required for compliance checking and to support product release in manufacturing. Data were collected from 5 independent laboratories that applied the AOAC Official First Action Method AOAC 2020.04 to demonstrate adequate performance under reproducibility conditions. Probability of Detection (POD) was calculated in blank test samples and test samples spiked at the Screening Target Concentration (STC) level, with the objective to achieve PODs ≤ 10% and ≥ 90%, respectively. Additionally, the effectiveness of the screening method was assessed through participation to 92 proficiency test samples. Four streams were optimized to screen for 152 veterinary drug residues by LC-MS/MS in a wide variety of food commodities including milk-based ingredients and related products (e.g., milk fractions, infant formula, infant cereals and baby foods), meat- and fish-based ingredients and related products (fresh, powdered, cooked, infant cereals and baby foods) and other ingredients such as eggs, animal fat and animal byproducts. The four streams covered 105 antibiotic residues, anti-inflammatory and antiparasitic agents (Stream A); 23 Beta-lactams (Stream B); 14 Aminoglycosides (Stream C) and 10 Tetracyclines (Stream D). The multi-laboratory validation led to PODs at the STC ≥ 94% and PODs in the blank ≤ 9%. Further application of the multi-laboratory validated method to 92 proficiency tests provided more than 99% satisfactory submitted results (n = 784). The inter-laboratory reproducibility determined for this method met the acceptance criteria defined in AOAC SMPR 2018.010. AOAC has approved the method for Final Action Status.
- 16 April 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (4) , 617-631
Screening of 152 Veterinary Drug Residues in Animal Source Foods by LC–MS/MS, Multilaboratory Validation Study: Final Action 2020.04
The presence of veterinary drug residues in food-producing animals and animal products is regulated through the enforcement of maximum residue limits (MRLs). To answer the need of the food sector to monitor these substances in a wide range of food commodities, stakeholders at AOAC identified the need for a reliable confirmatory screening method. Such qualitative approach is required for compliance checking and to support product release in manufacturing. Data were collected from 5 independent laboratories that applied the AOAC Official First Action Method AOAC 2020.04 to demonstrate adequate performance under reproducibility conditions. Probability of Detection (POD) was calculated in blank test samples and test samples spiked at the Screening Target Concentration (STC) level, with the objective to achieve PODs ≤ 10% and ≥ 90%, respectively. Additionally, the effectiveness of the screening method was assessed through participation to 92 proficiency test samples. Four streams were optimized to screen for 152 veterinary drug residues by LC-MS/MS in a wide variety of food commodities including milk-based ingredients and related products (e.g., milk fractions, infant formula, infant cereals and baby foods), meat- and fish-based ingredients and related products (fresh, powdered, cooked, infant cereals and baby foods) and other ingredients such as eggs, animal fat and animal byproducts. The four streams covered 105 antibiotic residues, anti-inflammatory and antiparasitic agents (Stream A); 23 Beta-lactams (Stream B); 14 Aminoglycosides (Stream C) and 10 Tetracyclines (Stream D). The multi-laboratory validation led to PODs at the STC ≥ 94% and PODs in the blank ≤ 9%. Further application of the multi-laboratory validated method to 92 proficiency tests provided more than 99% satisfactory submitted results (n = 784). The inter-laboratory reproducibility determined for this method met the acceptance criteria defined in AOAC SMPR 2018.010. AOAC has approved the method for Final Action Status.
- 18 July 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (6) , 1505-1524
Quantification of Chlorate and Perchlorate in a Broad Range of Food Commodities, Including Baby Food, Nutritional Formulas, and Ingredients by LC-MS/MS: First Action AOAC 2022.06
Chlorate is an effective herbicide, but also a by-product of chlorinating agents used to disinfect water, one of the reasons why it is regularly found in food. Perchlorate is a ubiquitous contaminant, which is naturally occurring in the environment but also released from anthropogenic sources such as the industrial use of certain natural fertilizers. Chlorate affects the hematological system, and perchlorate the thyroid. Implement and validate a simple and robust analytical method for the accurate determination of chlorate and perchlorate in baby food, infant and adult formulas, and ingredients thereof, which is suited for its application in routine environments where a broad variety of food commodities must be analyzed simultaneously. Typically, analytes are extracted with a mixture of water, acidified methanol and dichloromethane. Optionally, for dairy products and byproducts, extraction can be performed with water, acidified methanol and EDTA, followed by two steps clean-up (freezing-out and dispersive solid phase extraction with C18 in acetonitrile). Quantitative determination is carried out by isotopic dilution liquid chromatography tandem mass spectrometry (LC-MS/MS). The method was single laboratory validated in five Nestlé Quality Assurance Centers (NQACs) in a comprehensive range of representative matrices of different categories such as baby foods, infant/adult formulas and ingredients, with results generally in agreement with the acceptance criteria of the Standard Method Performance Requirements (SMPR) 2021.001 defined by AOAC INTERNATIONAL, in terms of representative matrices validated, LOQs, trueness and precision.
- 18 July 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (6) , 1505-1524
Quantification of Chlorate and Perchlorate in a Broad Range of Food Commodities, Including Baby Food, Nutritional Formulas, and Ingredients by LC-MS/MS: First Action AOAC 2022.06
Chlorate is an effective herbicide, but also a by-product of chlorinating agents used to disinfect water, one of the reasons why it is regularly found in food. Perchlorate is a ubiquitous contaminant, which is naturally occurring in the environment but also released from anthropogenic sources such as the industrial use of certain natural fertilizers. Chlorate affects the hematological system, and perchlorate the thyroid. Implement and validate a simple and robust analytical method for the accurate determination of chlorate and perchlorate in baby food, infant and adult formulas, and ingredients thereof, which is suited for its application in routine environments where a broad variety of food commodities must be analyzed simultaneously. Typically, analytes are extracted with a mixture of water, acidified methanol and dichloromethane. Optionally, for dairy products and byproducts, extraction can be performed with water, acidified methanol and EDTA, followed by two steps clean-up (freezing-out and dispersive solid phase extraction with C18 in acetonitrile). Quantitative determination is carried out by isotopic dilution liquid chromatography tandem mass spectrometry (LC-MS/MS). The method was single laboratory validated in five Nestlé Quality Assurance Centers (NQACs) in a comprehensive range of representative matrices of different categories such as baby foods, infant/adult formulas and ingredients, with results generally in agreement with the acceptance criteria of the Standard Method Performance Requirements (SMPR) 2021.001 defined by AOAC INTERNATIONAL, in terms of representative matrices validated, LOQs, trueness and precision.
- 17 November 2022
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 40 (1) , 81-95
Confirmation of the full conversion of ethylene oxide to 2-chloroethanol in fumigated foodstuffs: possible implications for risk assessment
This study describes the extension of a gas chromatography mass spectrometry (GC-MS) method, initially devoted to the analysis of ethylene oxide (EO) in ice cream, to a larger range of food items including herbs, spices, vegetables, inorganic salts, food supplements, thickeners, etc. Results are reported as EOTotal according to EC 2015/868 definition (expressed as EO equivalents as the sum of native EO and 2-chloroethanol (2-CE) after acidic hydrolysis) with a limit of quantification at 0.01 mg/kg regardless of the food item. Its ruggedness was demonstrated through fortification experiments on hundreds of samples. Re-analysis of 146 positive food samples without hydrolysis demonstrated that not EO but 2-CE is the predominant analyte detected in the different processed ingredients suspected to have been previously treated with EO. A series of eight contaminated dried herbs and spices were also re-analysed by four ISO 17025 accredited commercial laboratories making use of different analytical strategies for EO determination in foods. Each laboratory reported EOTotal levels within the same concentration range, but the resulting reproducibility ranged from 23% to 41% depending on the sample. Additionally, we show that results of free EO from methods based on conversion to 2-iodoethanol may lead to artefactual detection of native EO (false positive). An official method of analysis applicable for different food matrices would be useful to avoid discrepancies of results. Altogether, these data re-enforce the fact that in absence of native EO in food items, risk assessment of EO in foodstuffs should consider the predominance of 2-CE. A toxicological risk assessment using the food additive xanthan gum as a case study is discussed.
- 17 November 2022
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 40 (1) , 81-95
Confirmation of the full conversion of ethylene oxide to 2-chloroethanol in fumigated foodstuffs: possible implications for risk assessment
This study describes the extension of a gas chromatography mass spectrometry (GC-MS) method, initially devoted to the analysis of ethylene oxide (EO) in ice cream, to a larger range of food items including herbs, spices, vegetables, inorganic salts, food supplements, thickeners, etc. Results are reported as EOTotal according to EC 2015/868 definition (expressed as EO equivalents as the sum of native EO and 2-chloroethanol (2-CE) after acidic hydrolysis) with a limit of quantification at 0.01 mg/kg regardless of the food item. Its ruggedness was demonstrated through fortification experiments on hundreds of samples. Re-analysis of 146 positive food samples without hydrolysis demonstrated that not EO but 2-CE is the predominant analyte detected in the different processed ingredients suspected to have been previously treated with EO. A series of eight contaminated dried herbs and spices were also re-analysed by four ISO 17025 accredited commercial laboratories making use of different analytical strategies for EO determination in foods. Each laboratory reported EOTotal levels within the same concentration range, but the resulting reproducibility ranged from 23% to 41% depending on the sample. Additionally, we show that results of free EO from methods based on conversion to 2-iodoethanol may lead to artefactual detection of native EO (false positive). An official method of analysis applicable for different food matrices would be useful to avoid discrepancies of results. Altogether, these data re-enforce the fact that in absence of native EO in food items, risk assessment of EO in foodstuffs should consider the predominance of 2-CE. A toxicological risk assessment using the food additive xanthan gum as a case study is discussed.
- 14 October 2022
- Published by Elsevier in Microchemical Journal
- Vol. 183, 108057
Extended coverage of veterinary drug residues in food by LC-HRMS to ensure food compliance and prevent the spread of antimicrobial resistance
- 14 October 2022
- Published by Elsevier in Microchemical Journal
- Vol. 183, 108057
Extended coverage of veterinary drug residues in food by LC-HRMS to ensure food compliance and prevent the spread of antimicrobial resistance
- 13 September 2022
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 39 (11) , 1785-1796
Rapid and Reliable Data Treatment for the Control of Food Chemical Contaminants by LC-HRMS
Liquid chromatography-high resolution mass spectrometry (LC-HRMS) is considered an unavoidable extension of low-resolution LC-MS/MS that stretches the capabilities of multi-residue analysis of chemical contaminants in food. However, LC-HRMS acquisitions generate a massive amount of information available for data processing with supplier software that still miss critical calculation features and adapted reporting tools. Consequently, routine laboratories are still reluctant to switch from LC-MS/MS to LC-HRMS, the latter is still perceived as a cumbersome and demanding technology. In that context, we propose a four-step LC-HRMS workflow to speed-up data processing in situations of multi-residue multi-matrix analysis with the goal to maximize the time spent on data interpretation rather than on data formatting. The first three steps of the workflow imply specific settings on the Orbitrap HRMS associated software (TraceFinderTM) while the fourth step is the novelty i.e. a newly coded R-script capable to translate a raw export file into a comprehensive .xlsx report file in a few seconds. As recommended by various international guidelines and in some official methods, standard addition-based applications are fully embedded in this reporting tool whilst still being the main bottleneck of supplier’s software. The reporting tool also allows appropriate data formatting, filtering, and color-coding options to provide a clear picture of compounds being detected or not, and those requiring specific attention due to unmet quality control criteria as required by European legislation (European Commission SANTE 11312/2021). It is hoped that additional functionalities compatible with R scripts will be soon fully embedded in the supplier’s software for easier data interpretation and reporting.
- 13 September 2022
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 39 (11) , 1785-1796
Rapid and Reliable Data Treatment for the Control of Food Chemical Contaminants by LC-HRMS
Liquid chromatography-high resolution mass spectrometry (LC-HRMS) is considered an unavoidable extension of low-resolution LC-MS/MS that stretches the capabilities of multi-residue analysis of chemical contaminants in food. However, LC-HRMS acquisitions generate a massive amount of information available for data processing with supplier software that still miss critical calculation features and adapted reporting tools. Consequently, routine laboratories are still reluctant to switch from LC-MS/MS to LC-HRMS, the latter is still perceived as a cumbersome and demanding technology. In that context, we propose a four-step LC-HRMS workflow to speed-up data processing in situations of multi-residue multi-matrix analysis with the goal to maximize the time spent on data interpretation rather than on data formatting. The first three steps of the workflow imply specific settings on the Orbitrap HRMS associated software (TraceFinderTM) while the fourth step is the novelty i.e. a newly coded R-script capable to translate a raw export file into a comprehensive .xlsx report file in a few seconds. As recommended by various international guidelines and in some official methods, standard addition-based applications are fully embedded in this reporting tool whilst still being the main bottleneck of supplier’s software. The reporting tool also allows appropriate data formatting, filtering, and color-coding options to provide a clear picture of compounds being detected or not, and those requiring specific attention due to unmet quality control criteria as required by European legislation (European Commission SANTE 11312/2021). It is hoped that additional functionalities compatible with R scripts will be soon fully embedded in the supplier’s software for easier data interpretation and reporting.
- Open Access
Levels of Alternaria Toxins in Selected Food Commodities Including Green Coffee
Alternaria toxins are emerging mycotoxins, candidates for regulation by European Authorities. Therefore, highly sensitive, confirmatory, and reliable analytical methodologies are required for their monitoring in food. In that context, an isotope dilution LC-MS/MS method was developed for the analysis of five Alternaria toxins (Altenuene, Alternariol, Alternariol monomethylether, Tentoxin, and Tenuazonic Acid) in a broad range of commodities including cereals and cereal-based products, tomato-based products, tree nuts, vegetable oils, dried fruits, cocoa, green coffee, spices, herbs, and tea. Validation data collected in two different laboratories demonstrated the robustness of the method. Underestimation of Tenuazonic Acid level in dry samples such as cereals was reported when inappropriate extraction solvent mixtures were used as currently done in several published methodologies. An investigation survey performed on 216 food items evidenced large variations of Alternaria toxins levels, in line with data reported in the last EFSA safety assessment. The analysis of 78 green coffee samples collected from 21 producing countries demonstrated that coffee is a negligible source of exposure to Alternaria toxins. Its wide scope of application, adequate sample throughput, and high sensitivity make this method fit for purpose for the regular monitoring of Alternaria toxins in foods.
Open AccessLevels of Alternaria Toxins in Selected Food Commodities Including Green Coffee
Alternaria toxins are emerging mycotoxins, candidates for regulation by European Authorities. Therefore, highly sensitive, confirmatory, and reliable analytical methodologies are required for their monitoring in food. In that context, an isotope dilution LC-MS/MS method was developed for the analysis of five Alternaria toxins (Altenuene, Alternariol, Alternariol monomethylether, Tentoxin, and Tenuazonic Acid) in a broad range of commodities including cereals and cereal-based products, tomato-based products, tree nuts, vegetable oils, dried fruits, cocoa, green coffee, spices, herbs, and tea. Validation data collected in two different laboratories demonstrated the robustness of the method. Underestimation of Tenuazonic Acid level in dry samples such as cereals was reported when inappropriate extraction solvent mixtures were used as currently done in several published methodologies. An investigation survey performed on 216 food items evidenced large variations of Alternaria toxins levels, in line with data reported in the last EFSA safety assessment. The analysis of 78 green coffee samples collected from 21 producing countries demonstrated that coffee is a negligible source of exposure to Alternaria toxins. Its wide scope of application, adequate sample throughput, and high sensitivity make this method fit for purpose for the regular monitoring of Alternaria toxins in foods.
- 1 July 2020
- Published by Elsevier in Food Chemistry
- Vol. 318, 126469
Development, validation and application of a LC-MS/MS method for quantification of 15 cannabinoids in food
- 1 July 2020
- Published by Elsevier in Food Chemistry
- Vol. 318, 126469
Development, validation and application of a LC-MS/MS method for quantification of 15 cannabinoids in food
- Open Access
Multiple Mycotoxins Determination in Food by LC-MS/MS: An International Collaborative Study
An intercollaborative study was organized to evaluate the performance characteristics of a liquid chromatography tandem mass spectrometry procedure for the simultaneous determination of 12 mycotoxins in food, which were ochratoxin A, aflatoxins B1, B2, G1, G2, and M1, deoxynivalenol, zearalenone, fumonisins B1 and B2, and T-2 and HT-2 toxins. The method combined the simplicity of the QuEChERS (Quick, Easy, Cheap, Efficient, Rugged and Safe) approach with the efficiency of immunoaffinity column cleanup (the step used to enhance sensitivity and sample cleanup for some matrices only). Twenty-three entities were enrolled and were European reference laboratories for mycotoxin analysis, U.S. and European service laboratories, and Nestlé laboratories. Each participant analyzed 28 incurred and/or spiked blind samples composed of spices, nuts, milk powder, dried fruits, cereals, and baby food using the protocol given. Method performances were assessed according to ISO 5725-2. Relative standard deviations of repeatability and reproducibility and trueness values for each of the 115 mycotoxin/sample combinations ranged from 5% to 23%, 7% to 26%, and 85% to 129%, respectively, in line with requirements defined in EC 401/2006. The overall set of data gathered demonstrated that the method offered a unique platform to ensure compliance with EC 1881/2006 and EC 165/2013 regulations setting maximum limits for mycotoxins in food samples, even at low regulated levels for foods intended for infants and young children. The method was applicable regardless of the food, the regulated mycotoxin, and the concentration level, and thus is an excellent candidate for future standardization.
Open AccessMultiple Mycotoxins Determination in Food by LC-MS/MS: An International Collaborative Study
An intercollaborative study was organized to evaluate the performance characteristics of a liquid chromatography tandem mass spectrometry procedure for the simultaneous determination of 12 mycotoxins in food, which were ochratoxin A, aflatoxins B1, B2, G1, G2, and M1, deoxynivalenol, zearalenone, fumonisins B1 and B2, and T-2 and HT-2 toxins. The method combined the simplicity of the QuEChERS (Quick, Easy, Cheap, Efficient, Rugged and Safe) approach with the efficiency of immunoaffinity column cleanup (the step used to enhance sensitivity and sample cleanup for some matrices only). Twenty-three entities were enrolled and were European reference laboratories for mycotoxin analysis, U.S. and European service laboratories, and Nestlé laboratories. Each participant analyzed 28 incurred and/or spiked blind samples composed of spices, nuts, milk powder, dried fruits, cereals, and baby food using the protocol given. Method performances were assessed according to ISO 5725-2. Relative standard deviations of repeatability and reproducibility and trueness values for each of the 115 mycotoxin/sample combinations ranged from 5% to 23%, 7% to 26%, and 85% to 129%, respectively, in line with requirements defined in EC 401/2006. The overall set of data gathered demonstrated that the method offered a unique platform to ensure compliance with EC 1881/2006 and EC 165/2013 regulations setting maximum limits for mycotoxins in food samples, even at low regulated levels for foods intended for infants and young children. The method was applicable regardless of the food, the regulated mycotoxin, and the concentration level, and thus is an excellent candidate for future standardization.