Martin Uray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Uray has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Huber
Salzburg University of Applied Sciences
5 shared publications - Stefan Wintersteller
Salzburg University of Applied Sciences
2 shared publications - Adam Law
MedPhoton GmbH, Salzburg, AUSTRIA
1 shared publication Anastasiia Parii
MedPhoton GmbH, Salzburg, AUSTRIA
1 shared publication- Angel Pop
Department for Information Technologies and Digitalisation
1 shared publication - Barbara Giunti
University at Albany Albany NY USA
1 shared publication
Latest Publications
- 25 November 2026
- Published by Springer Nature
- p. 85-94
Persistence-Based Line Detection in Hough Space
- 3 August 2026
- Published by Springer Nature
- p. 90-101
Federated Learning for Multivariate Time Series Anomaly Detection in Industrial Automation
- 3 August 2026
- Published by Springer Nature
- p. 90-101
Federated Learning for Multivariate Time Series Anomaly Detection in Industrial Automation
- Open Access
- 27 July 2024
- Published by Elsevier in Journal of Manufacturing Systems
- Vol. 76, 75-91
Topological Data Analysis in smart manufacturing: State of the art and future directions
- 27 July 2024
- Published by Elsevier in Journal of Manufacturing Systems
- Vol. 76, 75-91
Open AccessTopological Data Analysis in smart manufacturing: State of the art and future directions
- 4 January 2024
- Published by Springer Nature
- p. 21-27
CSRX: A Novel Crossover Operator for a Genetic Algorithm Applied to the Traveling Salesperson Problem
- 4 January 2024
- Published by Springer Nature
- p. 21-27
CSRX: A Novel Crossover Operator for a Genetic Algorithm Applied to the Traveling Salesperson Problem
- Open Access
Topological Data Analysis in smart manufacturing processes -- A survey on the state of the art
Topological Data Analysis (TDA) is a mathematical method using techniques from topology for the analysis of complex, multi-dimensional data that has been widely and successfully applied in several fields such as medicine, material science, biology, and others. This survey summarizes the state of the art of TDA in yet another application area: industrial manufacturing and production in the context of Industry 4.0. We perform a rigorous and reproducible literature search of applications of TDA on the setting of industrial production and manufacturing. The resulting works are clustered and analyzed based on their application area within the manufacturing process and their input data type. We highlight the key benefits of TDA and their tools in this area and describe its challenges, as well as future potential. Finally, we discuss which TDA methods are underutilized in (the specific area of) industry and the identified types of application, with the goal of prompting more research in this profitable area of application.
Open AccessTopological Data Analysis in smart manufacturing processes -- A survey on the state of the art
Topological Data Analysis (TDA) is a mathematical method using techniques from topology for the analysis of complex, multi-dimensional data that has been widely and successfully applied in several fields such as medicine, material science, biology, and others. This survey summarizes the state of the art of TDA in yet another application area: industrial manufacturing and production in the context of Industry 4.0. We perform a rigorous and reproducible literature search of applications of TDA on the setting of industrial production and manufacturing. The resulting works are clustered and analyzed based on their application area within the manufacturing process and their input data type. We highlight the key benefits of TDA and their tools in this area and describe its challenges, as well as future potential. Finally, we discuss which TDA methods are underutilized in (the specific area of) industry and the identified types of application, with the goal of prompting more research in this profitable area of application.
- 30 March 2022
- Published by Springer Nature
- p. 75-81
Beyond Desktop Computation: Challenges in Scaling a GPU Infrastructure
- 30 March 2022
- Published by Springer Nature
- p. 75-81
Beyond Desktop Computation: Challenges in Scaling a GPU Infrastructure
- 1 January 2022
- Published by Springer Nature
- p. 611-618
Improvements for mlrose Applied to the Traveling Salesperson Problem
- 1 January 2022
- Published by Springer Nature
- p. 611-618
Improvements for mlrose Applied to the Traveling Salesperson Problem
- 8 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145002
A Monte Carlo based scatter removal method for non-isocentric cone-beam CT acquisitions using a deep convolutional autoencoder
The primary cone-beam computed tomography (CBCT) imaging beam scatters inside the patient and produces a contaminating photon fluence that is registered by the detector. Scattered photons cause artifacts in the image reconstruction, and are partially responsible for the inferior image quality compared to diagnostic fan-beam CT. In this work, a deep convolutional autoencoder (DCAE) and projection-based scatter removal algorithm were constructed for the ImagingRing TM system on rails (IRr), which allows for non-isocentric acquisitions around virtual rotation centers with its independently rotatable source and detector arms. A Monte Carlo model was developed to simulate ( i ) a non-isocentric training dataset of ≈1200 projection pairs (primary + scatter) from 27 digital head-and-neck cancer patients around five different virtual rotation centers (DCAE NONISO ), and ( ii ) an isocentric dataset existing of ≈1200 projection pairs around the physical rotation center (DCAE ISO ). The scatter removal performance of both DCAE networks was investigated in two digital anthropomorphic phantom simulations and due to superior performance only the DCAE NONISO was applied on eight real patient acquisitions. Measures for the quantitative error, the signal-to-noise ratio, and the similarity were evaluated for two simulated digital head-and-neck patients, and the contrast-to-noise ratio (CNR) was investigated between muscle and adipose tissue in the real patient image reconstructions. Image quality metrics were compared between the uncorrected data, the currently implemented heuristic scatter correction data, and the DCAE corrected image reconstruction. The DCAE NONISO corrected image reconstructions of two digital patient simulations showed superior image quality metrics compared to the uncorrected and corrected image reconstructions using a heuristic scatter removal. The proposed DCAE NONISO scatter correction in this study was successfully demonstrated in real non-isocentric patient CBCT acquisitions and achieved statistically significant higher CNRs compared to the uncorrected or the heuristic corrected image data. This paper presents for the first time a projection-based scatter removal algorithm for isocentric and non-isocentric CBCT imaging using a deep convolutional autoencoder trained on Monte Carlo composed datasets. The algorithm was successfully applied to real patient data.
- 8 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (14) , 145002
A Monte Carlo based scatter removal method for non-isocentric cone-beam CT acquisitions using a deep convolutional autoencoder
The primary cone-beam computed tomography (CBCT) imaging beam scatters inside the patient and produces a contaminating photon fluence that is registered by the detector. Scattered photons cause artifacts in the image reconstruction, and are partially responsible for the inferior image quality compared to diagnostic fan-beam CT. In this work, a deep convolutional autoencoder (DCAE) and projection-based scatter removal algorithm were constructed for the ImagingRing TM system on rails (IRr), which allows for non-isocentric acquisitions around virtual rotation centers with its independently rotatable source and detector arms. A Monte Carlo model was developed to simulate ( i ) a non-isocentric training dataset of ≈1200 projection pairs (primary + scatter) from 27 digital head-and-neck cancer patients around five different virtual rotation centers (DCAE NONISO ), and ( ii ) an isocentric dataset existing of ≈1200 projection pairs around the physical rotation center (DCAE ISO ). The scatter removal performance of both DCAE networks was investigated in two digital anthropomorphic phantom simulations and due to superior performance only the DCAE NONISO was applied on eight real patient acquisitions. Measures for the quantitative error, the signal-to-noise ratio, and the similarity were evaluated for two simulated digital head-and-neck patients, and the contrast-to-noise ratio (CNR) was investigated between muscle and adipose tissue in the real patient image reconstructions. Image quality metrics were compared between the uncorrected data, the currently implemented heuristic scatter correction data, and the DCAE corrected image reconstruction. The DCAE NONISO corrected image reconstructions of two digital patient simulations showed superior image quality metrics compared to the uncorrected and corrected image reconstructions using a heuristic scatter removal. The proposed DCAE NONISO scatter correction in this study was successfully demonstrated in real non-isocentric patient CBCT acquisitions and achieved statistically significant higher CNRs compared to the uncorrected or the heuristic corrected image data. This paper presents for the first time a projection-based scatter removal algorithm for isocentric and non-isocentric CBCT imaging using a deep convolutional autoencoder trained on Monte Carlo composed datasets. The algorithm was successfully applied to real patient data.